Sei sulla pagina 1di 3
PowerPact H-, J-, and L-Frame Circuit Breakers Motor Circuit Protection 2 Electronic Motor Circuit Protectors (AC Only) PowerPact H- and J-trame Electronic Motor Circuit Protectors (MCP) are instantaneous-tip circuit breakers. They are designed to offer shor circuit protection and are National Electrical Code (NEC®) compliant when installed as part of a combination controller having motor overload protection. MCP circuit breakers accept the same accessories and terminals as the equivalent thermal-magnetic circuit breakers. (See Section 3 for Accessories.) “The unique design of the PowerPact MCPs includes two rotary switches to allow quick setting adjustments based on the characteristics of the motor. “The first rotary switch allows for Full Load Ampores (FLA) adjustment across the range ofthe frame size. ‘The second rotary switch selects the type of motor protection based on Automatic 1 for Standard Efficieney or Automatic 2 for High Energy Erficient. When using the automatic settings the MCP microprocessor automatically adjusts the trp settings for both current and time to align with the star-up characteristic for the motor type, whether itis a standard or energy-efficient motor. Ths includes a dampening means to accommodate a transient moter in-rush current without nuisance tripping of the circult breaker. Rotary switch 2 also allows for traditional motor protection from 8 to 13 times the selected FLA. ‘The MCP rotary switches are detented and allow the device to be set to specific tip values within a typical accuracy range of +/-5%. (A) Full Load Amp Setting (FLA). (B) Instantaneous Trip Point Settings (Ip). pre tae || seep MEE asa Full Load Amp Settings 1. Determine the motors ful-load current by referring to the nameplate on the motor. 2. Sot the trip range by turning the FLA rotary switch tothe setting closest to the motor's fll load current. Automatic Protection Settings “The MCP microprocessor automaticaly adjust the trip settings for both current an time to align with the start-up characteristics for the motor type selected. This includes a dampening means to accommodate a transient motor in-rush current without nuisance tripping ofthe circuit breaker. 022016 EEE] "©2011-2016 Senneider Electric ‘All Rights Reserved Dy Sehnelder Cecerie PowerPact H-, J-, and L-Frame Circuit Breakers Motor Circuit Protection Figure 4: Automatie Protection Settings B A Imxra_/ \ ‘Auto Seting ie t Axe Oanoerinater i Nosorinen > Manual Protection Settings ‘The manual settings may be adjusted to multiples of current based on the rotary switch setting for motor Full Load Amps (FLA) msg point | = (FLA) x (Im) For example, if FLA rotary switch is set to 20 and jy, rotary switch is set to 8x, then the instantaneous. trip point will be 180 A A B A. FullLoad Ap Seting (FLA) 1. instrtanaovs Trp Pont Seng ‘See Tables 55 thru 57 for more information Table 50: _H- and J-Frame Electronic Motor Circuit Protectors (MCP) eame | current | sinatd | hlvstable | yue| (See SCOR Table Below) [See SCOR Table Below) Range ‘Telp Range Cat. No, |Cat. No, Cat, No. ras 100.4 30-808 180-1040 A (M73 | HuLas100M73 |HLL36100M73. HRL36100M73 + High Short Circuit Current Ratings (SCCR) ‘The PowerPact MCP helps achieve the high ULSOBA Short Circuit Current Rating (SCCR) needed to meet NEC Article 409 requirements for industrial control panels. They deliver up to 100 KA at 480 Vac SCOR when used in combination with approved Square D™ NEMA or Schneider Electrio™ IEC motor stares. Table 51: _ Short Circult Current Ratings (SCCR) contactors interrupting interrupting R Interrupting [200-240 Vac] 480 Vac | 00Vac [200-240 Vac| 480 Vac | 600 Vac [200-260 Vac| 480 Vac | 600 Vac Tay Dine and Fave] tax | esr] ema] 100% soem | aoa | —a00Ka | 00K NEMA Type § rwowa | o64a_| asia] 100m soxa | _z00%a | zoosa_| 10048 53 0272016 Szorrto10 saver bee Ai Rte Ravens | SQUARE E] By Sehnelder Feccrc PowerPact H-, J-, and L-Frame Circuit Breakers Motor Circuit Protection Table 5 McP Selection by HP Ratings of Induction-Type Squirrel-Cage and Wound-Rotor Motors Horsepower Rating of nduction-Type Squirre+-Cage and Wound-Rotor Motors 30.60 Hz] NEC FullLead| _ PowerPact Frame and ‘StarterSe | 200vae_ | 730 Vae a0 Vac S75 Vac Amperes | _-Frame Electronic MCP 1 1a a4 a we z 12 aa. 2 aan Huseosomr Tea on 15 we aL Hutasosonre 30 soe © sta aseroowra 3 » «0 so ek Huseroours on 16.50%~ x A nd » an usersoure « rr so-100 150 tu and 80 1508 suua62sours 5 " z 1928 (ir Shaded woe bral covered by are elector meio eeu poe 54 022016 {© 2011-2016 Schnelaer Elesie ‘All Rights Reserved

Potrebbero piacerti anche