Several versions of LabVIEW have furthered the ability to develop distributed applications: TCP/IP, Internet Toolkit, VI
Server, Front Panel Web Publishing, Remote Data Acquisition (RDA), DataSocket, and so on. In addition, several third
party toolkits have enabled internet-based VI control: LabVNC and AppletVIEW. Then, of course, there has always
been PC Anywhere and other similar applications that provide general remote control of a PC.

With enough effort, you can create distributed applications using these tools. However, each one presents unique
challenges, often requiring advanced programming techniques and development of custom data handling
mechanisms.

This brings us to LabVIEW remote panels. One of the first things you learn when you begin programming in LabVIEW
is that VIs consist of front panels, diagrams, and behind the scenes, compiled executable code. Furthermore, these
components are always bound together for a VI that is executing. Granted, you can remove diagrams, but the front
panel and compiled code have both been required for operating a front panel.

With LabVIEW, you can operate your front panel on a machine that is separate from where the VI resides and
executes. Furthermore, you can embed the front panel into a web page and operate it within that page. All that is
required on the client machine for executing in a web page is a browser and the LabVIEW run-time engine and
browser plug-in.

You will be amazed at how easy remote panels are to configure and use. There are two steps:

1. Enable the LabVIEW Web Server on the server machine.

2. Connect and execute remote panels on the client machine.

zone.ni.com/devzone/cda/tut/p/id/4791 1/15
12/19/2010 Remote Panels in LabVIEW -- Distribut…
The following sections describe these steps for operating remote panels in both the LabVIEW environment and web
pages.

Figure 1: Distributed Application

For both remote panel scenarios (within the LabVIEW environment or embedded in a web page), the web server must
be configured and enabled on the server machine. It is important to note that server in this context simply means a
networked computer that is running the LabVIEW Web Server.

Three areas of configuration are required:

File directories and network settings


Permitted clients
Visible VIs

You can configure directories and network settings by selecting Tools>>Options>>Web Server: Configuration(see
Figure 2). Enable the web server by clicking the appropriate checkbox. The default port number for the web server is
80. In general, port numbers 49152 through 65535 are dynamic/private ports recommended for custom TCP/IP
applications. Other options that you can set include the root directory for the server HTML files, the timeout for reading
by the web server, and log file enabling to record information pertaining to client connections.

zone.ni.com/devzone/cda/tut/p/id/4791 2/15
12/19/2010 Remote Panels in LabVIEW -- Distribut…

zone.ni.com/devzone/cda/tut/p/id/4791 3/15
12/19/2010 Remote Panels in LabVIEW -- Distribut…

Figure 2: Web Server: Configuration Dialog Box for LabVIEW 6.1-7.1, 8.0, 2009 and 2010.

The next step is to specify a list of client IP addresses that are allowed to access the Web Server. Each IP address
may be granted controlling privileges, viewing only privileges, or denied access. You can find this dialog box by
selecting Tools>>Options>>Web Server: Browser Access(see Figure 3). An asterisk (*) as shown is the wildcard that
grants access to any IP address.

zone.ni.com/devzone/cda/tut/p/id/4791 4/15
12/19/2010 Remote Panels in LabVIEW -- Distribut…

zone.ni.com/devzone/cda/tut/p/id/4791 5/15
12/19/2010 Remote Panels in LabVIEW -- Distribut…

Figure 3: Web Server: Browser Access Dialog Box for LabVIEW 6.1-7.1, 8.0, 2009 and 2010.

The final step is to specify a list of VIs that can be accessed remotely. You can find this dialog box by selecting
Tools>> Options>>Visib le VIs(see Figure 4). You can set control time limits for each VI in the list. This control time
limit is very useful if your VI will be accessed by multiple users. If there is no control time limit, a single user could
monopolize control of the application, preventing other users from assuming control.

zone.ni.com/devzone/cda/tut/p/id/4791 6/15
12/19/2010 Remote Panels in LabVIEW -- Distribut…

zone.ni.com/devzone/cda/tut/p/id/4791 7/15
12/19/2010 Remote Panels in LabVIEW -- Distribut…

Figure 4: Web Server: Visible VIs Dialog Box for LabVIEW 6.1-7.1, 8.0, 2009, and 2010.

All of these configuration values are also available through VI Server and can be controlled programmatically. To
provide web browser access, one additional step is required in setting up the server machine: you must publish a
web page to be accessible through the web server using the Tools>>Web Pub lishing Tool menu selection. This tool
allows user input of the VI name to embed, a title, and text information on the provided template. It then automatically
creates an HTML file that you must save to the root directory specified during the first step of Web Server configuration.
The Web Publishing Tool is a convenient method for creating the page, but you also can create your own HTML page
manually. See the LabVIEW online help for information on how to create your own.

You only need to create a web page for top-level VIs. All subVI front panels set to open during execution will pop up on
the remote machine in separate windows from the browser window (see the "Special Considerations" section for
more details).

Now you are ready to run a remote panel from the LabVIEW environment. If you have LabVIEW, copy GSystems

zone.ni.com/devzone/cda/tut/p/id/4791 8/15
12/19/2010 Remote Panels in LabVIEW -- Distribut…
Remote Panel Demo.vi from the LTR Resource CD to your LabVIEW Web Server machine. Configure the Web Server
options as previously described. (If you want to bypass the Web Server configuration for now and just operate a
remote panel, you can connect to a demo VI on a G Systems server.)

Even if you do not currently have the LabVIEW development system, you can still operate a demo remote panel. We
have included a simple LabVIEW application, Launch Demo From Lab VIEW, on the LTR Resource CD that provides
the standard LabVIEW Operate menu. Installing this demo application also installs the LabVIEW run-time engine.

On your client machine, from either the LabVIEW development system menu or the Launch Demo From LabVIEW
application menu, select Operate>>Connect to Remote Panel to display the Connect to Remote Panel dialog box
from LabVIEW (see Figure 5).

zone.ni.com/devzone/cda/tut/p/id/4791 9/15
12/19/2010 Remote Panels in LabVIEW -- Distribut…

Figure 5: Connect to Remote Panel Dialog Box for LabVIEW 6.1-7.1, 8.0, 2009, and 2010.

Complete the following steps for this dialog box:


1. In the Server IP Address field, enter the IP address, domain name, or computer name to which you will connect.
For the G Systems demo server, enter demo.gsystems.com.
2. In the VI Name field, enter the name of the top-level VI you want to operate remotely. For the G Systems demo, enter
GSystems Remote Panel Demo.vi.
3. In the Port field, enter the HTTP Port that was enabled during the Web Server configuration. The G Systems demo
value is 50000.
4. If you want to immediately request control of the front panel, place a checkmark in the Request Control checkbox.
(You can request control later by right-clicking on the remote front panel window when it appears.)
5. Click the Connect button. The remote panel will appear on your computer. If access is denied, an error message
appears in the Connection Status section of the Connect to Remote Panel dialog box. The number of licenses for the
G Systems demo is limited. If you are not granted control, please try again later.

By default, the number of remote panel connections LabVIEW allows is limited to one. You can purchase additional
licenses from NI to allow multiple simultaneous connections managed by the NI License Manager. In this regard, an
important tool for monitoring and controlling remote connections is located at Tools>>Remote Panels Connection
Manager. This utility displays connection information and provides server control of current connections (see Figure
6).

zone.ni.com/devzone/cda/tut/p/id/4791 10/15
12/19/2010 Remote Panels in LabVIEW -- Distribut…

zone.ni.com/devzone/cda/tut/p/id/4791 11/15
12/19/2010 Remote Panels in LabVIEW -- Distribut…

Figure 6: Remote Panel Connection Manager for LabVIEW 6.1-7.1, 8.0, 2009, and 2010.

The most exciting feature of remote panels is the ability to control LabVIEW remote VIs from a web browser. To
operate remote panels from a browser, you must first have the LabVIEW run-time engine and browser plug-in
installed on the client machine. (If you do not have LabVIEW yet, install the LabVIEW 6.1 run-time engine from the LTR
Resource CD.) Next, you simply browse to the URL that comprises the server IP, network name, or domain name
plus the HTML file name containing the embedded VI you want to operate. Within a LAN environment, the URL might
appear as http://PcName: Port/ViName.htm. If you are operating the VI from an internet connection, the URL might
appear as http://lpAddr:Port/ViName.htm.

zone.ni.com/devzone/cda/tut/p/id/4791 12/15
12/19/2010 Remote Panels in LabVIEW -- Distribut…
When the remote panel appears in the browser, right-click on the panel to display a pop-up menu. Use this menu to
request remote control of the demo VI as shown in Figure 7. You can set up your own web page using the VI on the
LTR Resource CD or one of your own. Also, you can try the demo page at http://demo.gsystems.com/GSystems
Remote Panel Demo.htm.

Figure 7: Requesting Remote Control of the Demo VI

One interesting thing to try: From the Operate menu on a browser-displayed remote panel, you can select Connect to
Remote Paneland connect to a remote panel using the dialog box you would normally see from the LabVIEW
environment!

To execute remotely, the VI you want to execute must be loaded in memory (not necessarily running) on the server.
From the server, you can regain control of the application at any time.
User interface manipulation, such as window position and size, does not work as intended on the remote panel.
Size and complexity of the front panel impacts control latency.
Sound and other system access calls do not operate on the client machine, but on the server machine only.
ActiveX controls are not functional on remote panels.

zone.ni.com/devzone/cda/tut/p/id/4791 13/15
12/19/2010 Remote Panels in LabVIEW -- Distribut…
SubVI front panels do not open when viewed in a browser on a Mac. They are disabled due to technical limitations of
Mac browser plug-ins.
If your VI is designed to open other VIs front panels by using the FP .Open VI Server property (as opposed to a subVI
call where the subVI is configured to open its panel when called), the front panel will not open.
On all platforms, VI properties that manipulate a VI front panel do not take effect on the remote client side.
Duplicate IP addresses and visible VIs are allowed in the Web Server configuration the last entry overrides any
previous entry.
The File Dialog function (File I/O>>Advanced>>File Dialog) in LabVIEW returns TRUE for the cancelled output
terminal and does not show a file dialog when the VI is remotely controlled. This is for security considerations to
prevent remote clients from viewing the server’s file system.
If you build an executable application for remote control, you must also include the NI License Manager utility in your
installer by clicking the Advanced button in the Settings tab and placing a checkmark in the Remote Panel License
Support checkbox. Without the Remote Panel Support, an executable will allow one connection. If an executable is to
be installed on another machine, a separate license will need to be purchased for that machine.
For web page remote panels, the size of the remote panel is the same as the size of the panel used to create the
HTML file. To change the size of the remote panel, you must resize the server VI window and resave the HTML file.

Table 1 compares some differences between remote panels in a Web Browser and remote panels in the LabVIEW
environment.

Table 1: Remote Panels in a Web Browser vs. LabVIEW

With LabVIEW, remote front panels not only can be viewed, but can also be controlled from either the LabVIEW
environment or a web browser. This powerful tool will enable many programmers to create distributed applications
easily. Just think - you can sit at home relaxing on the weekend while you monitor and control your LabVIEW
application at the office, lab, or production line from your laptop! 'Most importantly, you can call up your friends and say,
"Hop on the web and try out this cool LabVIEW application I just wrote!"

Many thanks to Naresh Shenkeshi, Mike Fortenberry, Yumiko Kawachi, and Carlos Yapura, who made major
contributions to this article.

LabVIEW Technical Resource (LTR) is the leading independent source of LabVIEW-specific information. Each LTR
issue presents powerful tips and techniques and includes a Resource CD packed with VIs, Utilities, Source Code,
and Documentation.

Related Links:
LabVIEW Information

zone.ni.com/devzone/cda/tut/p/id/4791 14/15
12/19/2010 Remote Panels in LabVIEW -- Distribut…
Reader Comments | Submit a comment »

Remote Panel License Support


To build an executable application for remote control with the current version of LabVIEW, how does one include the
NI License Manager utility in the installer? Neither build specifications for application nor installer contain described
Settings tab, Advanced button, Remote Panel License Support checkbox.
- Jul 28, 2009

Out of date page


Hey, This page desparately needs to be updated with the relative ease in creating remote web panels with LV 7.x.
Remote panels in LabVIEW is easier than this document lets on....
- Oct 1, 2004

Legal
This tutorial (this "tutorial") was developed by National Instruments ("NI"). Although technical support of this tutorial
may be made available by National Instruments, the content in this tutorial may not be completely tested and verified,
and NI does not guarantee its quality in any way or that NI will continue to support this content with each new revision
of related products and drivers. THIS TUTORIAL IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND AND
SUBJECT TO CERTAIN RESTRICTIONS AS MORE SPECIFICALLY SET FORTH IN NI.COM'S TERMS OF USE
(http://ni.com/legal/termsofuse/unitedstates/us/).

My Profile | RSS | Privacy | Legal | Contact NI © 2010 National Instruments Corporation. All rights reserved. | E-Mail this Page

zone.ni.com/devzone/cda/tut/p/id/4791 15/15

Potrebbero piacerti anche