Sei sulla pagina 1di 11

HYDRODYNAMIC FORCE CALCULATION FOR PIER

рw a H H/a Ce coefficients C1,C2,C3,C4


10 6.3 7.8 1 0.39
2 0.575 S.NO. C1
Ce 0.451167 3 0.675 1 0
H/a 1.238095 4 0.73 2 0.1
Ah 0.06 3 0.2
4 0.3
5 0.4
we=рw*Π*a2*H 9720.8748 6 0.5
7 0.6
F=Ce*Ah*we 263.1440808 8 0.8
Pb=1.2*F/H 40.48370474 9 1

total hydrodynamic force 263.144081


hydrodynamic moment 878.480199

Hydrostatic force

height of pier 9 m
ht of water level at u/s (max) 7.8 m
Specific weight of water 10
pressure due to water 39 kn/m2
γw*h 78
resulatant force acting h/3 from bot 304.2
790.92 kn-m
ts C1,C2,C3,C4

C2 C3 C4 C1H C2Pb C3F C4H


0 0 0 0 0 0 0
0.41 0.026 0.934 0.78 16.59832 6.841746 7.2852
0.673 0.094 0.871 1.56 27.24553 24.73554 6.7938
0.832 0.184 0.81 2.34 33.68244 48.41851 6.318
0.922 0.289 0.751 3.12 37.32598 76.04864 5.8578
0.97 0.403 0.694 3.9 39.26919 106.0471 5.4132
0.99 0.521 0.639 4.68 40.07887 137.0981 4.9842
0.999 0.76 0.532 6.24 40.44322 199.9895 4.1496
1 1 0.428 7.8 40.4837 263.1441 3.3384

hydodynamic
0 5 10 15 20 25 30 35 40 45
0

3
hydodynamic
4

Height of water γw*h


0 0
1 10
2 20
3 30
4 40
5 50
6 60
7 70
8 80
9 90
Hydrostatic force

height of abutment 9
ht. of soil 9
depth of water 6
density of soil 16
Ф ∆ α β
30 20 0 0
0.523599 0.349066 0 0

coefficient of active earth pressure ka 0.368459

active earth pressure

force due to soil


0.75
1
1
these values are only for
0.766044 calculation of coefficient of
0.5 active earth pressuere
1
0.939693
SPECIFIC WT OF CONCRETE 24 KN/M3
Axial Loads

load from super structure


dead load of bridge girder No. 2 size 1.1 0.75
dead load of deck slab size 0.2 3.5
dead load of footpath No. 2 size 0.2 0.45
dead load of railing No. 2 size 0.3 1
vehicular laod (max) For B class 400 KN
Breaking force taking as 20% of total axial force 80
dead load of static gantry crane with gate 500 KN
dead load of girder under moving gantry No. 2 size 1.25
Weight of gate 200 KN
load of moving gantry 300 KN
load of moving gantry with gate 500 KN
load of moving gantry taken as 25% 125

transverse forces

HYDROSTATIC FORCE DUE TO WATER IN U/S


Level of top of pier 296 m
Emergency water level 294.8 m
Height of freeboard 1.2 m
Maximum water level 293 m
level of bottom of pier 287 m
Total Height Of Pier 9 m
Maximum Height of water u/s of pier 7.8 m
Dimensions of pier 2.7 12.6 9

Force on pier due to water when reservoir is full upto EWL 304.2 KN
Resultant force will act h/3 from base of the pier
momemt from base of pier at resultant force 790.92 KN-M

HYDRODYNAMIC FORCE DUE DUE TO WATER IN U/S 263.14408 KN


momemt from base of pier at resultant force 878.4802 KN-M
Axial strength of pier 16200
Factored load with factor
1.5
12.6 498.96 KN 748.44 KN
12.6 211.68 KN 317.52 KN
12.6 54.432 KN 81.648 KN
12.6 181.44 KN 272.16 KN
600 KN
120
750 KN
0.5 12.6 378 KN 567 KN

750 KN
125 KN
Total axial forces on Pier 3977.96 KN

0.8784802
0.0025704
2570.4375 246364.4
122.13147 190.58732011 11086398
1000
stability check (d/s empty)

self wt of pier 7076.16 kn


Total axial load

Max transverse force due to water in u/s 304.2 kn

Potrebbero piacerti anche