PASSED AS/NZS 4858:2004

Vulkem Non-Exposed WET AREA MEMBRANES


CSIRO REPORT NO #3200
PRODUCT
DATA
SHEET

Membrane

Vulkem Non-Exposed Membrane


ONE PART POLYURETHANE TECHNICAL INFORMATION
WATERPROOFING MEMBRANE
TYPICAL PHYSICAL PROPERTIES
Property Test Method Result
KEY BENEFITS SUMMARY Tensile ASTM D-412 2MPa
Elongation ASTM D-412 600%
Hardness (Shore A) ASTM C-661 20
 Permanently flexible 600% Peel Strength ASTM C-794 133N
 Meets requirements of AS3740-2004 Permeability E-96 0.12metric perms

 Fast curing
UL 790 CLASS A FIRE RATING
 Compatible with Metz and RLA tile adhesives CAN/ULC – S102.2 – M88 CLASS A RATING
 High strength and puncture resistant
Wet Material Properties
 Vertical and horizontal applications
VOC 205g/L
 Easy to apply Viscosity, cps Brookfield HBT 8-10,000
 Resistant to range of chemicals and pollutants Cure Time ASTM D-1640 48 hours max
@25°C-50% RH
Flash point Setaflash 45°C

PRODUCT INFORMATION NOTE: Typical Properties should not be used as


Specifications.
DESCRIPTION
Vulkem Non-Exposed is a single pack elastomeric, moisture USAGE GUIDELINES
curing, high tensile strength and tough curing polyurethane One part urethane, Vulkem Non-Exposed
membrane. It cures to form a flexible rubber membrane. Membrane bonds firmly to clean, dry concrete
and well anchored wood substrates. It retains its
Vulkem Non-Exposed Membrane may be used to apply a integrity even if the substrate movement causes
seamless, monolithic waterproof membrane to concrete hairline cracks up to 1.5mm. It cut or damaged,
substrates, compressed sheeting plywood which is well Vulkem Non-Exposed Membrane will prevent
anchored and primed. Simple and easy to apply by either water migration between its substrate. Vulkem
notched trowel, roller or brush. Non-Exposed Membrane can be finished after a
48 – 72 hour cure at temperatures over 15.6°C.
USAGE/PURPOSE
SUBSTRATE PREPARATION
 Wet Areas  Concrete should be cured for 28 days
 Laundries, showers  Remove all dirt, dust, plaster, cement
 Roof terraces droppings, protrusions, oils and other
 Kitchens contaminants. Fill screw holes.
 Decks  To the wall/floor junctions and the floor/hob,
 Balconies hob/wall joints within the shower tray, apply
 Concrete Substrate Plazas fillet bead of Dymonic NT Polyurethane
 Sandwich membrane Sealant as a bond breaker. Apply sealant
around floor penetrations, tap and shower
COLOUR rose and other discontinuities Floor wastes in
Grey concrete shall be cut level with the floor. For
sheet flooring, leak control flanges shall be
PACK SIZE PRODUCT CODE fitted and fully sealed.
19 Litre Pail 215110  Cracks: non movement and hairline cracks
600ml sausages 215111 may be filled with a brush coat of Vulkem
Non-Exposed Membrane. Movement cracks
to be routed out, cleaned and filled with
Dymonic NT
Vulkem Non-Exposed
Membrane
PRIMING HEALTH & SAFETY PRECAUTIONS
 All wood surfaces are to be primed using Vulkem When applying in confined spaces ensure good
Primer 171 ventilation, forced ventilation may be required.
 All metal surfaces are to be primed using by The Material Safety Data Sheet (MSDS) must be
TREMprime Non-Porous Primer (Vulkem Primer 181) read and understood prior to use.
 Existing polyurethane membrane surfaces are to be
primed using Vulkem Primer 191

TECHNICAL SERVICE
METHOD OF APPLICATION
TREMCO has a team of qualified Technical Sales
 Mix the Vulkem Non-Exposed Membrane to ensure no
Representatives who provide assistance in the
settlement of the material is in the bottom of the pail
selection and specification of products. For more
and the colour of the material is consistent with no
detailed information or service and advice, call
streaks or striations
Customer Service on (02) 9638 2755 or fax (02) 9638
 All internal wet areas should be waterproofed to meet
2955.
AS 3740-2004 requirements
 Apply one coat of Vulkem Non-exposed Membrane at
specified coverage rates using either brush, roller or
squeegee GUARANTEE/WARRANTY
 Ensure the membrane is turned down into the floor TREMCO products are manufactured to rigid
waste or well sealed around the leak control flange and standards of quality. Any product which has been
other penetrations. Ensure flashing angles are properly applied (a) in accordance with TREMCO written
sealed across doorways. Check for pin holes in the instructions and (b) in any application recommended
membrane when dry and rectify. by TREMCO, but which is proved to be defective,
 A light broadcast of sand into the Vulkem Non-Exposed will be replaced free of charge.
Membrane, while still wet will ensure good bond with tile
adhesive
Any information provided by TREMCO in this
document in relation to TREMCO’s goods or their
COVERAGE use is given in good faith and is believed by
 Approximately 1.2L/m2 at a dry film thickness of 1mm TREMCO to be appropriate and reliable. However,
(approximately 16m2 per 18.9L pail to achieve the the information is provided as a guide only, as the
waterproof requirements as stated in AS 3740-2004. actual use and application will vary with application
 Approximately 0.6L/m2 at a dry film thickness of 0.5mm conditions which are beyond our control. TREMCO
(approximately 32m2 per 18.9L pail) to achieve water makes no representation, guarantee or warranty
resistant requirements as stated in AS 3740-2004 relating to the accuracy or reliability of the
(vertical applications) information and assumes no obligation or liability in
connection with the information. To the extent
permitted by law, all warranties, expressed or
CLEAN UP
implied are excluded.
Thoroughly clean tools with Tremco IPA Cleaner before
handling. Clean hands with Tremco Tub O’ Towels or
soapy water.

TREMCO PTY LTD ABN 25 000 024 064


Unit 1, 2 Park Rd, RYDALMERE NSW 2116 Australia
Tel (02) 9638 2755 Fax (02) 9638 2955
An Company Tremco@Tremco.com.au

Potrebbero piacerti anche