Pre-Installation Checklist TFX 48

Pre-Installation Checklist TFX 48

1 General
Dimensions (W x L x H): 2.65 m x 1.45 m x 1.35 m
Floor space required: 4.65 m x 4.80 m
Machine weight: 1800 kg

Revision 1 Rev. Date 13-10-14 Printing date 13-10-14


Page 1 of 4 Pre-installation - TFX48 - ENG -R1.docx
Pre-Installation Checklist TFX 48

Footprint of leveling feet:

Customer .......................................................................................................................
Exact shipping address: .......................................................................................................................
.......................................................................................................................
.......................................................................................................................

Responsible for installation: ......................................................................................................................

Name & Phone number: .......................................................................................................................

2 Environment:
Door width (required for delivery) (min 150cm): ......................................................................................
Room size in sqm: ......................................................................................
Floor space of 2.30 m x 3.00 m available: Yes No
Floor conditions
• Wooden floor or raised computer floors are forbidden.
• The floor covering should be one that not attract dust, is easy to clean and doesn’t produce static
electricity (e.g. carpets should be avoided).
• No vinyl, carpet or similar covering should be used underneath the engine. The engine should
always be installed directly on a solid, concrete floor.
• The floor may have a slope of maximum 10mm/m2.
Floor conditions OK? Yes No

Revision 1 Rev. Date 13-10-14 Printing date 13-10-14


Page 2 of 4 Pre-installation - TFX48 - ENG -R1.docx
Pre-Installation Checklist TFX 48

3 Air conditioning
max. 26 °C, humidity ≤ 70 %, non-condensing
(fluctuations 2 degrees Celsius) Yes No
Exhaust connection available: 40 mm, 80 l/min Yes No

4 Ventilation
The ventilation of the room should have sufficient capacity for the following reasons:
• To avoid sudden change in operating conditions due to the system’s heat dissipation.
• To avoid O3 buildup in the room above a level of 0,05 ppm.
The air refreshment flow rating has to be at least 1500m³/h
Ventilation OK? Yes No

5 Electrical connection:
3x400V/N/PE +/-10%, 10A Yes No
50 Hz 60 Hz
Earth Leakage Circuit Breaker >300mA: Yes No
Earth Connection: There must be a separated earth connection with a resistance less than 2 ohm.
Lightning Protection: It’s best to install a Lightning protector before the power supply of the engine. This will
secure the engine from suffering severe damage when the lightning strikes.
High Leakage Current: The machine has a high leakage current.
Over Current Protection: Branch circuit protection is not provided. Therefore an over-current protection
needs to be installed in the power supply line.

6 Compressed air:
The press air quality should answer the ISA class 8573-1 norm.
1. fix particles: Class 3 = 5 µm
2. humidity: Class 4 = dew point 3°C but dew point should always be 15°C below the coldest possible
environment and/or press air temperature.
3. Oil: (compress oil!) Class 2 = 0.1mg/m³. (This is oil free air)
Minimum pressure: 6 bar Yes No
Press air nominal consumption: 50l/min Yes No
Press air peak consumption 100l/min Yes No
Connection: 0.5” Yes No

7 Network Connection:
A direct connection between the machine and the multiplate is advised (2nd network card).
1 GB Base T available: Yes No
2 available IP addresses*: ........................................ / .........................................................................
*In case a direct connection is used 1 IP address is sufficient.
2 ethernet cables are needed for installation

PC for Multiplate software,


Provided by customer: Windows XP Windows 7
(windows 7 is advised)
Connected to internet for remote service?
(Teamviewer) : Yes No

Revision 1 Rev. Date 13-10-14 Printing date 13-10-14


Page 3 of 4 Pre-installation - TFX48 - ENG -R1.docx
Pre-Installation Checklist TFX 48

To enable fast and smooth service support, our service personnel must be granted access to multiplate host
PC or any other PC. Through that PC, we should be able to connect with the machine. This requires some
setup at the client side. First of all the Teamviewer software should be installed on that PC and must be
accessible from the internet. Firewall settings or modifications or safety settings in the corporate network are
not necessary. Off course this connection must only be activated when remote service is needed and will be
tested at installation.

8 Comments and Signature:


...................................................................................................................
...................................................................................................................
...................................................................................................................
...................................................................................................................
...................................................................................................................
...................................................................................................................
...................................................................................................................
...................................................................................................................
...................................................................................................................
Signature: ............................................................................................

Phone number: .................................................................................................

Please return to your Xeikon representative by e-mail. servicethermoflexx@xeikon.com Thank you.

Revision 1 Rev. Date 13-10-14 Printing date 13-10-14


Page 4 of 4 Pre-installation - TFX48 - ENG -R1.docx