Cable Information
Type ELTB
Conductor Size 4
Length 4627.56 ft
KV 4 kV
Temperature Rating 400 OF
Protector
Thrust Bearing Type 400 Maximus HL Oil Type REDA OIL#5
Number of Seals 3
Configuration BPBSL
Number of Chambers 3
Components SINGLE
Sensor
Device Information Phoenix xt150 Type 1
Protector
Thrust Bearing Type 540HL Oil Type REDA OIL#5
Number of Seals 3
Configuration BPBSL
Number of Chambers 3
Components SINGLE
Sensor
Device Information Phoenix xt150 Type 1
Conditions at Operating Frequency
Operating Frequency 50 Hz Volts @Junction Box 1852 Volts
Motor Amp 35.6 Amps KVA @Junction Box 114.03
Total Motor Load 103.4 hp Motor Volts 1806.7 Volts
Seal Selection:
Seal angle (set depth)= 16.89 Deg fm vert. Oil temperature at thrust chamber = 332°F
No sand present Chamber Cap Used (Top to Bot)=
Pump uses Floater&Floater type stages 19% 16% 15%
Motor/Seal Oil type = CL6 Thrust bearing load =4 %
Seal Selected: GSB3 DB [ 513 Series] Shaft load = 5 %
Options: HL
513 GSB3DBHL
Motor Selection:
Terminal Voltage =351 V Fluid Speed =1.526ft/s
Motor Current =34.9 A Eff/PF =88.17% I 82.04%
Load ace to N.P. =57.7 % Internal Temp =326.1°F
Shaft Load =2.5% Motor Selected: MSP1-250
42HP 475V 53A [562Series]
562 MSP1
*NOTE: Motor ratings at 60Hz
Cable Selection-
Surface Length 50.0ft Wellhead Voltage 400.7V
Tubing Length 4681ft Wellhead kVA 24.3kVA
MLE length 30.0ft Voltage Drop 4g.6V
Surface Temp 150°F Cond Temp (main) 273.5°F
Temp Rating 500.0°F
Surface Cable Main Cable MLE Cable
#1 CELFS.OkV SO.Oft #1 CELF5.0kV 4681ft #4 MLE-KLHT5.0kV 30.0ft
power: #1 5 kV MLE: #4 5 kV
Controller Selection·
Surface KW 20.4kW Voltage Input 480.0V
Input kVA 30.5kVA Max Well Head Volts 400.7V
System kW 20.gkW Target Frequency 50.0Hz (9.59V/Hz)
Max Ctrl Current 38.4A Start Frequency 19.1Hz
Power CosUkWH 0.05$/kWH Step-up Trafo 1.1 ratio
Total Power Cost = $750.8/month Selected: VSD 2150-VT 163kVA/ 480V/ 196A
163 kVA microdrive
Page 4 of 5