Parameter Symbol Value Unit Note

Pipe
Part - Collector Connections - -
Material - SS 1.4571 SS 1.4571 - -
0.2% offset yield strength at 20°C K 210 210 N/mm 2 -
Safety factor S 1,8 1,8 - 1.8 for elongation at break equal to 15%, 1.75 for elongation at break equal to 20% and 1.7 for elongation at break greater than 25%
2
Maximum permissible static load σzul 117 117 N/mm -
Operating pressure p 70 70 bar -
Nominal diameter - 50 20 mm -
Outer diameter da 60,3 22,0 mm -
Weld seam quality νN 1,0 1,0 - 1 for seamless pipes
Calculated wall thickness sv 1,81 0,66 mm -
Calculated internal diameter di 56,7 20,7 mm -
Permissible wall thickness reduction c'1 12,5% 12,5% - -
Wall thickness increase for corrosion or wear c2 0,00 0,00 mm 0 for austenitic steel
Minimum required wall thickness s 2,07 0,75 -
Design wall thickness se 4,5 2,0 mm -
Tee connection
Supporting length ai 10,3 4,7 mm -
Attenuation factor for vertical connections νA 0,54 1,00 - -
Calculated wall thickness sv 3,38 0,66 mm -
Minimum required wall thickness s 3,86 0,75 mm -
Check if design wall thickness is adequate - Ok Ok - -
Subsequent tee connections
Distance between connections is enough mm 120,0 mm From axis to axis
Check if distance between connections is sufficient - Ok - -
Attenuation factor for vertical connections νL 0,82 1,00 - -
Calculated wall thickness sv 2,21 0,66 mm -
Minimum required wall thickness s 2,53 0,75 mm -
Check if design wall thickness is adequate - Ok Ok - -
Bends
Type - Standard elbow - -
Curvature radius r 50,0 20,0 mm 1 x DN in standard elbows, 1.5 x DN in long radius elbows
Inner side calculated wall thickness sv,i 3,13 1,04 mm -
Minimum required inner side wall thickness si 3,57 1,19 mm -
Outer side calculated wall thickness sv,a 1,42 0,53 mm -
Minimum required outer side wall thickness sa 1,63 0,60 mm -
Check if design wall thickness is adequate - Ok Ok - -
Dished ends
Type - Decimal head - -
Curvature radius R 60,3 22,0 mm 1 x da in decimal heads, 0.8 x da in semi-ellipsoidal heads
Dome calculated wall thickness sv 1,84 0,67 mm -
Minimum required dome wall thickness s 2,11 0,77 mm -
β factor β 2,27 2,27 - -
Brim calculated wall thickness sv 2,06 0,75 mm -
Minimum required brim wall thickness s 2,35 0,86 mm -
Check if design wall thickness is adequate - Ok Ok - -
Concentric reducer
Reduction angle ϕ1 According to DIN 2616 Part 2 (see at end)

c'1* 12,5% 12,5% - -


Design wall thickness reduction
c 1* 0,56 0,25 mm -
Design minimum wall thickness sv * 3,9 1,8 mm -
Design internal diameter di* 52,4 18,5 mm -