Sei sulla pagina 1di 3

SITE ID SITE NAME TOWER HT.

DATE
V.A.S DESIGN & INFRA CONSULTANTS PVT. LTD
PU/BA/AT/18736 TARKSHEEL CHOWK 12M SPIRE 11.02.2018

DESIGN OF BASE PLATE AND ANCHOR BOLT


TOWER HT. DETAIL OF = 12M SPIRE M
MAX. COMPRESSIVE FORCE = 170 KN
MAX. TENSIL FORCE = 160 KN
MAX SIDE THRUST = 13 KN
SITE ID SITE NAME TOWER HT. DATE
V.A.S DESIGN & INFRA CONSULTANTS PVT. LTD
PU/BA/AT/18736 TARKSHEEL CHOWK 12M SPIRE 11.02.2018

MAX FOUNDATION FORCES ACTING ON BUILDING COLUMN:


Down Thrust = 270.08 KN
Side Thrust = 191.58 KN

Uplift = 118.68 KN
Side Thrust = 191.58 KN

FOS = 1.5
LENGTH WIDTH
Existing Column size in mm = 230 x 230

Grade of concrete = 20 N/mm^2


Grade of Steel = 415 N/mm^2
Area Of Steel Provided (Existing) = 803.8 mm^2
Area Of Steel Provided (Existing) = 0.0 mm^2
Area Of Steel Provided (Proposed) = 803.8 mm^2
Total area of steel = 1607.7 mm^2
Existing Dia of Reinformcement 4 Nos 16 Dia
Existing Dia of Reinformcement 0 Nos 0 Dia
Proposed hilty Re-bar 4 Nos 16 Dia
Compression
Capacity in compression = 646.71
Pu=0.4xFckxAcx+0.67xFyxAsc > 270.08
Safe

Tention
Capacity in tension = 223.51
Tention=0.67xFyxArea of Steel > 118.68
Safe
DESIGN OF HILITY REBARING

Determination of Basic Anchorage Length :

Lb (reqd.) = (Ds/4)x( st/fbd)

Where As
Ds = Diameter of Rebar
st = Calculated Design Stress of Rebar
fbd = Design Value of ond strength

Assume Diameter of Rebar = 16 mm


Calculated Design Stress of Rebar = 147.57 N/mm^2
270.084x1000/(4x0.7854x16^2
Design value of bond strength = 1.9 N/mm^2 For 40mm Cover
As Per Hilty Manual

Lb (reqd.) = 310.67 mm

Lbd = 1 x 2 x 3 x 42 x 5x Lbd(Reqd)
SITE ID SITE NAME TOWER HT. DATE
V.A.S DESIGN & INFRA CONSULTANTS PVT. LTD
E-126 PNB ROAD SHASTRI NAGAR DELHI-110052 PU/BA/AT/18736 TARKSHEEL CHOWK 12M SPIRE 11.02.2018

Where
1 = Effect of Form of the forms of Bars
2 = Effect of minimum Concrete cover
3 = Effect of Confinment of Transeverse Reinforcement

4 = Effect of infulence of one of more wleded Bars


along with Design Annchorage Length,
5 = Effect of Pressure Transverse to the Plane of
Splitting along with Design Anchorage Length

For compression = 1x 2x 3x 4 = 1

lbd (min) (10xDs) = 160

310

Provide 310 mm depth for the Hilti Rebar with RE500 Compound

DESIGN OF WELD LENGTH PROPOSED COLUMN

Force in the Exisitng Column = 270.084 KN


LENGTH WIDTH
Size of Existing Column in mm 230 X 230

Diameter of Existing Bar = 16 mm


Nos. of Bar in Existing Column = 4 Nos.

Size of weld Proposed = 6 mm


Capacity of 6mm thick filet Weld = 528 N/mm
6x110x0.8

Force in existing column bar = 67.52 KN


270.084x4

Length of weld required = 127.88 mm

Length of weld proposed = 200 mm

Potrebbero piacerti anche