Sei sulla pagina 1di 2

‫آموزشگاه مجازی ایران پایپینگ‬

CALCULATIONS AND SKETCHES


www.IranPiping.ir JOB NO. 07Z68310

BY N.R.D DATE
Central Region Houston, Texas CHKD. BALA DATE
PAGE 1 OF 1 REV.
CLIENT AND LOCATION
UNIT RCC
ITEM 8"-BW-09111-B4A2S-INS

Variables General Information

P= 400 Design Pressure Material = A 106 B


D= 8.625 Actual Outside Diameter of Pipe Sc = 20,000
S= 20,000 Maximum allowable stress in material at design temp. (Sh) Sh = 20,000
see appendix "A" in ANSI B31.3 Design
Y= 0.4 A coefficient having values as given in the temp = 400
ANSI Code Table 304.1.1, A; normally 0.4 Spec. = B4A2S
A= 0.125 Allowance for corrosion, erosion, etc., in.
E= 1 Quality Factor Table A1-A or A-1B from 31.3

Selected Wall thickness SCH. = XS Wall = 0.5

T= Nominal thickness of actual purchased pipe minus mill tolerance -------------- 0.438

** Caution! tm should never exceed T

t= (P) (D) t= 3450 t= 0.086 tm = t+A = 0.211 **


2 (SE + PY) 40320

MAWP = SET = 6250 = MAWP= 1493 (Max allowable working pressure


(D/2 - T)+0.6 T 4.1875

Mt= 0.063 Mill tolerance of 12.5%

tm = 0.211 Minimum required thickness, including mechanical,


corrosion and erosion allowances

For Hydro Testing See Below

PT = 600 psig PT = Hydrotest Pressure based on design conditions (not MAWP of flanges)

Table 304.1.1 Values of coefficient y for t < d/6


Temperature, deg. F (C)
900 950 1,000 1,050 1,100 1,150
Materials (482)
& Lower (510) (538) (566) (593) & up
Ferritic 0.4 0.5 0.7 0.7 0.7 0.7
Austenitic 0.4 0.4 0.4 0.4 0.5 0.7
Steels
Other 0.4 0.4 0.4 0.4 0.4 0.4
ductile
Steels
Cast Iron 0

464057000.xls Page 1 of 2
12/27/2002

General Information

(Max allowable working pressure)

464057000.xls Page 2 of 2