Sei sulla pagina 1di 4

www.klinkmann.

com

programmable time switches


with digital display

037 05 047 61 047 70 047 64

Dimensions (p. 183)

For switching an electric circuit (lighting, heating) ON or OFF at selected times during a pre-programmed time period
Temporary (automatic return) or permanent (forced switching ON or OFF) override on output

Pack Cat.Nos Standard - daily or weekly programme with Pack Cat.Nos Multiple functions annual program
6 years clock working reserve Annual progam Number
of modules
Compatible with alternative renewable energy 1 047 70 Power supply 120/230 V± - 50/60 Hz 6
systems such us photovoltaic panels 4 outputs
Automatic summer/winter changeover High precision clock: ± 0.2 sec per day
Clock precision: ± 1 sec per day For programming periods throughout
Minimum programme setting: 1 min the year
28 programmes 84 programmes per channel possible:
Number of - 28 weekly / astronomical programmes
Power supply 120/230 V± - 50/60 Hz modules - 28 yearly programmes
1 037 05 1 output 16 A - 250 V± 1 - 28 exceptional programmes
µ cos ϕ = 1 per 1 inverter contact Manual override (switch on and off) for
Low consumption: 0.1 W every channel on the front of the switch
Programmed directly on keypad, or using
programme transfer key Cat.No 047 81
Multiple functions - daily or weekly Programming transfer key
programme with 6 years clock working 1 047 81 Can be used to store program settings made:
reserve - Directly on Cat.No 047 70 (loading on device)
- with the programming software installed on a PC
Programme settings: on daily or weekly basis running Windows (loading on data loader)
6 languages (GB, F, E, I, D, NL)
A programme consists of a on and off time and their Battery
assignement to certain days 1 047 82 Working reserve 5 years for Cat.No 047 70
Option to suspend the programme for a specific
period to set-up with start and date
Minimum programme setting: 1 min Programming software
High precision clock: ± 0.2 sec per day
Particularly suited to irregular cycles: Can be used to create, save and transfer
- security installations (access point, alarms, etc.), program settings for multifunction and
- industrial installations (pump stations, etc.) multi-program time switches,
Programmed directly on keypad, or using program Cat.Nos 047 61/63/64/67/70/71
transfer key Cat.No 047 72 Data is transferred to the program transfer key
Additional functions including impulse, random Cat.No 047 72, using the data loader connected to
(irregular cycles), hour counters Number of
the USB port of the PC
Power supply 230 V± - 50/60 Hz modules 1 047 73 Kit comprising software on CD-ROM, data loader
and transfer key
1 047 61(1) 1 output 16 A - 250 V± 2 Windows Vista compatible
56 programmes
µ cos ϕ = 1 per 1 inverter contact
84 impulses max. For outdoor illuminations
1 047 71 2 outputs 16 A - 250 V± 2
2 x 28 programmes Astronomical
µ cos ϕ = 1 per 2 inverter contacts For autonomous control of outdoor illuminations
Automatic programming: simply initialise the
Power supply 120 V± - 50/60 Hz products for the location with no need to install a
1 6047 60(1) 1 output 16 A - 250 V± 2 photoelectric cell
56 programmes Programmed directly on keypad, or using programme
µ cos ϕ = 1 per 1 inverter contact transfer key Cat.No 047 72
84 impulses max. High precision clock: ± 0.2 sec per day Number of
Power supply 24 V± - 50/60 Hz Power supply 230 V± - 50/60 Hz modules

1 047 63(1) 1 output 16 A - 24 V± 2 1 047 64 1 output 16 A - 250 V± 2


56 programmes 28 programmes
µ cos ϕ = 1 per 1 inverter contact 1 047 67 2 outputs 16 A - 250 V± 2
84 impulses max. 2 x 14 programmes
Programming transfer key
10 047 72 Can be used to store programme settings made:
- Directly on a multifunction and multi-programme
time switch Cat. No. 047 61/71/63 (loading on
device)
- with the programming software installed on a PC
running Windows (loading on data loader)
These products are part of protection
(1) Adjustable impulse duration from 1 sec to 59 min and distribution systems > See p. 142-143
Red catalogue numbers : New products

175
www.klinkmann.com

programmable time switches programmable time switches


with analogue dial with analogue and digital dial

n Diagrams
Cat.Nos 037 30/40/44 Cat.Nos 037 52/53/55
N L N L

16 A

037 40 037 53 037 55 U1 U2 1 4 2

Dimensions (p. 183)


Output

Programmed via captive segment Cat.No 047 70


1-module device: min. 1 segment
3-module device: min. 2 segments
Power supply: 230 V± - 50/60 Hz
3-position override switch "ON-AUTO-OFF" on front panel
Manual changeover to summer/winter time
1 outlet 16 A - 250 V± - µ cos ϕ = 1 120V/23
047 70 0Hz
0V 50/6
16A 230V
xxx=1
16A 230V
xxx=1

-20T
R6a 2
ON
1
ON AUTO
AUTO OFF
OFF
4

Pack Cat.Nos Daily programme


ON
3 O
ON AUT
O OFF
AUT
OFF

1 segment = 15 minutes L
N
S

Accuracy: ± 5 minutes
L
Vertical dial N
Minimum switching time: 15 mn Number
N/O contact of modules Cat.Nos 047 61/63, 6047 60
1 037 30 Without working reserve 1 N L

1 037 40 With 100 h working reserve 1


Horizontal dial
Minimum switching time: 45 minutes
Changeover switch
1 037 52 Without working reserve 3

1 037 53 With 100 h working reserve 3 Cat.No 047 64 Cat.No 047 67

4
1
3 2

Weekly programme
1 segment = 2 hours 4

Accuracy: ± 30 minutes
1
2

Vertical dial L L
Minimum switching time: 2 h Number N N
N/O contact of modules
1 037 44 With 100 h working reserve 1
Output closing and breaking times are calculated based on the date,
Horizontal dial the actual time when the device was switched and on geographical
Minimum switching time: 4 h coordinates of the actual location
Changeover switch
1 037 55 With 100 h working reserve 3
n Technical characteristics
Nb Nb
Min. Summer/ Outputs
Cat.Nos of of
Totalising hour counter on door (p. 104)
Prog. programme
time setting
Working
reserve
winter 16 A
time prog. mod.

037 05 7 d 1 mn 6 years auto 1 28 1


047 61 multi 1 mn 6 years auto 1 56 2
047 71 multi 1 mn 6 years auto 2 2 x 28 2
047 63 multi 1 mn 6 years auto 1 56 2
6047 60 multi 1 mn 6 years auto 1 56 2

Min. 16 A output Nb
Cat.Nos switching Working via contact
Programme Segment time reserve N/O Chang. S. of modules
037 30 24 h 15 mn 15 mn without 1 - 1
037 40 24 h 15 mn 15 mn 100 h 1 - 1
037 52 24 h 15 mn 30 mn without - 1 3
037 53 24 h 15 mn 30 mn 100 h - 1 3
037 44 7 d 2 h 2 h 100 h 1 - 1
These products are part of protection 037 55 7 d 2 h 4 h 100 h - 1 3
and distribution systems > See p. 142-143

176
www.klinkmann.com

analogue time switches analogue time switches

n Dimensions

Cat.No 6499 14
100.6 51 70

144.5
171.2

150.6

120
6499 14 6499 64 499 26

119.5 49
Power supply 230 V±
Override switching "ON" or "OF" in front face
Working reserve: 500 h with quartz controlled motor
(except Cat.No 499 26)
1 output via changeover contact Cat.Nos 6499 64/65/66/67
(2 changeover contacts for Cat.No 499 26) 72 52

Pack Cat.Nos Daily programme


20 A - 250 V± - µ cos ø = 1
1 6499 14 Shortest switching time: 30 minutes

112.2
109.4

(1 segment = 10 minutes)
Switching accuracy: + 5 minutes POWER

30 A - 230 V± - µ cos ø = 1 L
POWER
N N
LOAD
L

Shortest switching time: 20 minutes


(1 segment: 10 minutes)
Switching accuracy: + 30 minutes
IP 20
1 6499 64 230 V - 50/60Hz
Cat.No 497 56
72
1 6499 65 120 V - 50/60Hz
72
110

Weekly programme
16 A - 250 V± - µ cos ø = 1
69
1 497 56 Shortest switching time: 3 hours
(1 segment = 1 hour)
Switching accuracy: + 20 minutes
1 044 09 Adaptor for fixing time switch on rail EN 50022 4 n Technical Characteristics
30 A - 230 V± - µ cos ø = 1 Analogue time switches 30A
Shortest switching time: 2 hours
(1 segment: 1 hour) Conform to EN 50022, EN 55014-1, EN 55014-2, IEC 60730-1,
Switching accuracy: + 30 minutes IEC 60730-2-7, VDE 0631-1 and VDE 0631-2-7
IP 20
1 6499 66 230 V - 50/60Hz For special applications with heavy loads like controlling:
- the lighting of commercial boards / sign boards
- water heaters
1 6499 67 120 V - 50/60Hz
- air conditioners
- hydrochlorinators
- heating / ventilation systems
Defrosting time switch - street lighting
Time switch for short periods for control of defrosting, - blowers
regularly repeated switching of pumps, feed
conveyors, sprinkler systems, periodic lubrication of - pool heaters
machines - electric fences
16 A - 250 V± µ cos ø = 1 - filters, pumps and conveyers
IP 30
Daily programme
The timer can repeat one or two settable short
programmes within 24 hours
Shortest switching sequence 2.5 hours - up to 9 times
1 switching step = 1 segment = 30 min.
50 Hz
1 499 26 Defrosting time from 1 to 60 minutes per contact

177
www.klinkmann.com

light sensitive switches light sensitive switches

n Standard light sensitive switch (Cat.No 037 23)


Switch "ON" and "OFF" defined by a light level threshold
230 V
N L
Photoelectric cell
(supplied)
250V~

50 m max.

037 23 037 21

n Preprogrammed light sensitive switch (Cat.No 037 25)


4 possible programmes
Dimensions (p. 183)
1 - Switches "ON" at sunset and "OFF" at sunrise (e.g. in car parks,
green areas, etc.)
2 - Switches "OFF" when natural light level is low and comes on when
Can be used to switch a lighting circuit "ON" and "OFF" based on light natural light level is high (e.g. to imitate daily cycle in battery
conditions (nightfall, daybreak) farming conditions)
Supplied with photoelectric cell housed in Plexo weatherproof box 3 - Automatically switches "ON" at sunset following deliberate switching
Power supply: 230 V± - 50/60 Hz "OFF" by means of a push-button or timer (e.g. shop windows and
illuminated signs, etc.)
Pack Cat.Nos Standard 4 - Automatically switches "OFF" at dawn following deliberate
Number
of modules switching "ON" by means of a push-button or timer at night
1 037 23 Output 5 A - 250 V± - µ cos ϕ = 1 2 (e.g. offices, workshops)
1200 W incandescent Example of connection of 3rd program:
800 VA fluo serie compensated 230 V
300 VA fluo parallel compensated 45 µF N L
Timer response of approx. 45 sec
Adjustable from 0.5 to 200 lux

Preprogrammed Number
of modules
1 037 25 4 possible programmes 5 EM
50 m max.
Output 10 A - 250 V± - µ cos ϕ = 1
2000 W incandescent Photoelectric cell
2000 VA fluo serie compensated AM (supplied)
300 VA fluo parallel compensated 45 µF
Timer response of approx. 5 sec
Adjustable from 0.5 to 200 lux
n Programmable light sensitive switch (Cat.No 037 21)
Controls lighting according to the time and light level
Programmable with weekly time switch Minimum switching interval: 1 minute
Number Working reserve: 100 hrs
of modules
Manual switch: override/programme/stop
1 037 21 Output 10 A - 250 V± - µ cos ϕ = 1 2 Automatic changeover to summer/winter time
1000 W incandescent Temporary override with automatic return to programme
2000 VA fluo serie compensated
Timer response: 60 sec 230 V
Adjustable from 2 to 60000 lux N L
8 possible programmes (off periods
during the night)
50 m
max.
Replacement photoelectric cell Photoelectric cell
(Cat.No 695 18) for light sensitive switches (supplied)
Cat.No 037 21/23/25 (p. 744)

These products are part of protection


and distribution systems > See p. 142-143

178

Potrebbero piacerti anche