CALCULATION OF MAXIMUM PERMISSIBLE HYDROTEST PRESSURE 

FOR RADIAL NOZZLE ON ELLIPTICAL HEAD
NOZZLE MARK N1
Design Input
Description Code CL. Equ. No. Detail Units
Corrosion Allowance 0.1260
Di = inside diameter of a shell or head. 168.0000
Di = inside diameter of a shell or head (Corroded) 168.2520
tn2 = Nozzle Neck thickness 2.5984
tn2 = Nozzle Neck thickness (Corroded) 2.4724
h = height of the ellipsoidal head measured to the inside surface. 42.1260
tn = nominal thickness of the nozzle wall. 2.9528
tn = nominal thickness of the nozzle wall (Corroded) 2.8268
Dn=Nozzle Inside Diameter 22.4409
Rn = nozzle inside radius (Corroded) 11.3465
t = nominal thickness of the vessel wall (Lip Thickness) 1.1024
t = nominal thickness of the vessel wall (Lip Thickness-Corroded) 0.9764
R = vessel inside radius (Corroded) 84.1260
DR = distance from the head center line to the nozzle center line. 32.0079
te = thickness of the reinforcing pad. 0.0000
Lpr1 = nozzle projection from the outside of the vessel wall. 7.3096
Lpr3 = Heavy Barrel Length 3.7008
Lpr4 = nozzle projection from the outside of the vessel wall for variable thickness nozzles to nozzle thickness t n2 4.0552
L41 = weld leg length of the outside nozzle fillet weld. 0.7480
S = allowable stress from Annex 3-A for the vessel at the design temperature. 36100.0000 psi
Sn = allowable stress from Annex 3-A for the nozzle at the design temperature. 36100.0000 psi
hydrotest pressure 297.4300 psi

Detailed Calculations
4.5.11 Vessel Effective Radius
2
Reff = 0.9*Di / 6 *(2 + (Di / (2*h)) ) (4.5.87) 151.1251 inch
Rxn = tn / ln[1 + tn / Rn] (4.5.139) 12.7075 inch

4.5.11 Radius of Nozzle Opening Along the Long Chord


Rnc = Rn / cos[] (4.5.151) 11.5847 inch

4.5.11 Limit of Reinforcement Along the Vessel Wall


LR = min[ (Reff*t)0.5, 2*Rn] (4.5.89) 12.1474 inch
User specified limit governs = 3.2457" 3.2457 inch

4.5.11 Nozzle Attachment Factor


 = arctan[ (h / R)*(DR / ((R2 - DR2)0.5)) ] (4.5.109) 11.6410 inch
Xo = min[ DR + (Rn + tn)*cos[] , Di / 2 ] (4.5.107) 45.8896 inch
Cn = min[ ((t + te) / tn)0.35 , 1] (4.5.111) 0.6893
Fp = Cn (4.5.106) 0.6893

4.5.11 Limit of Reinforcement Along the Nozzle Wall Projecting Outside the Vessel Surface
LH = min[ t + te + Fp*(Rn*tn)0.5, Lpr1 + t] (4.5.102) 4.8803 inch
Corroded
0.5
LH = min[ 0.9764 + 0 + 0.6893*(11.3465*2.8268) , 7.3096 + 0.9764] = 4.8802"

4.5.11 Available Area Near the Nozzle Opening


2
A1 = t*LR (4.5.114) 3.1691 in
Lx3 = Lpr3 + t (4.5.121) 4.6772 inch
Lx4 = Lpr4 + t (4.5.123) 5.0316 inch
tnx = [ 1 + (tn - tn2) / tn2*(Lx4 - LH) / (Lpr4 - Lpr3)]*tn2 (4.5.37) 2.6237 inch
 Where Lx3 < LH ≤ Lx4 ; OK
A2a = tn*Lx3 (4.5.118) 13.2215 in2
A2b = (tn + tnx) / 2*min[ 0.78*(Rn*(tn + tnx) / 2)0.5 , LH - Lx3 ] (4.5.119) 0.5534 in2
A2 = A2a + A2b (4.5.116) 13.7749 in2
A41 = 0.5*L412 (4.5.127) 0.2798 in2
A5 0.0000 in2
frp 0.0000 in2

4.5.11 Design Rules for Openings in Shells and Heads


Chamber MAWP
Total available area near the nozzle opening
frn = min[ Sn / S , 1 ] (4.5.21) 1.0000 inch
teff = t + (A5*frp / LR) (4.5.141) 0.9764 inch
Rxs = teff / ln[1 + teff / Reff] (4.5.140) 151.6128 inch
AT = A1 + frn*A2 + A41 (4.5.113) 17.2237 in2
Forces at nozzle to vessel intersection
fN = P*Rxn*LH (4.5.134) 18445.3688 lbf
fS = P*Rxs*(LR + tn) / 2 (4.5.136) 136917.2084 lbf
fY = P*Rxs*Rnc / 2 (4.5.138) 261202.1144 lbf
Average local primary membrane stress
avg = (fN + fS + fY) / AT (4.5.143) 24185.4820 psi
General primary membrane stress
circ = P*Rxs / (2*teff) (4.5.144) 23092.0634 psi
Maximum local primary membrane stress at the nozzle intersection
PL = max[ {2*avg - circ} , circ] (4.5.145) 25278.9005 psi
Allowable stress
Sallow = 1.5*S*E (4.5.57) 54150.0000 psi
PL ≤ Sallow ; 25279 ≤ 54150; Since Maximum Induced Stresses are less than Allowable Stress , nozzle construction is
(4.5.146) psi
SAFE
Calculating Maximum Permissible Hydrotest Pressure of Nozzle
Ap = (fN + fS + fY) / P (4.5.150) 1400.5470 in2
Pmax1 = Sallow / (2*Ap / AT - Rxs / (2*teff)) (4.5.147) 637.1256 psi
Pmax2 = 2*S*(t / Rxs) (4.5.148) 464.9746 psi
Pmax = min[ Pmax1, Pmax2] (4.5.149) 464.9746 psi

Maximum Allowable Pressure is more than actual hydrotest Pressure , nozzle construction is SAFE