Sei sulla pagina 1di 45

MVC-CD500

Ver 1.2 2003. 07 SECTION 6 ADJ


Revision History ADJUSTMENTS

Link
Before starting adjustment SERVICE MODE
Adjusting items when replacing main parts and boards APPLICATION FOR ADJUSTMENT (SEUS)

SERVICE MODE
ADJUSTMENT
PREPARATIONS BEFORE ADJUSTMENT

INITIALIZATION OF 0E, 2F, 4F, 5F 6F PAGE DATA

VIDEO SYSTEM ADJUSTMENTS

CAMERA SYSTEM ADJUSTMENTS

LCD SYSTEM ADJUSTMENT

SYSTEM CONTROL SYSTEM ADJUSTMENT

Contents of LEVEL 2 and LEVEL 3 Service Manual


CONTENTS LEVEL 2 LEVEL 3
1. SERVICE NOTE a ✕
2. DISASSEMBLY a a
(DDX-G3000 COMPLETE ASSEMBLY)
3. BLOCK DIAGRAMS OVERALL, POWER ✕
4. PRINTED WIRING BOARDS AND PK-068, CK-133, FU-164 BOARD, CD-439, SY-086 BOARD
SCHEMATIC DIAGRAMS FLASH UNIT,
CONTROL SWITCH BLOCK
(RS-340),
FP-651 FLEXIBLE
5. REPAIR PARTS LIST EXPLODED VIEWS a
(DDX-G3000 COMPLETE ASSEMBLY)
ELECTRICAL PARTS a (CD-439, SY-086 BOARD)
6. ADJUSTMENTS ✕ a
(DDX-G3000 COMPLETE ASSEMBLY)

2003G1600-1
©2003.7
9-876-216-51 Sony EMCS Co. Published by DI CS Strategy Div.
MVC-CD500

TABLE OF CONTENTS
6. ADJUSTMENT 6-2. SERVICE MODE ·························································· 6-38
1. Before starting adjustment ··············································· 6-1 2-1. APPLICATION FOR ADJUSTMENT (SEUS) ············ 6-38
1-1. Adjusting items when replacing main parts and boards. ··· 6-2 2-1-1. Using Method of SEUS ················································· 6-38
6-1. ADJUSTMENT ······························································· 6-3 1. Connection ····································································· 6-38
1-1. PREPARATIONS BEFORE ADJUSTMENT ················· 6-3 2. Operation ······································································· 6-38
1-1-1. List of Service Tools ························································ 6-3 2-1-2. Precaution on Use of SEUS ··········································· 6-38
1-1-2. Preparations ····································································· 6-4 2-2. SERVICE MODE ·························································· 6-39
1-1-3. Discharging of the flashlight power supply ····················· 6-4 1. Setting the Test Mode ···················································· 6-39
1-1-4. Precaution ········································································ 6-6 2. Bit value discrimination ················································ 6-39
1. Setting the Switch ···························································· 6-6 3. Switch check (1) ···························································· 6-40
2. Order of Adjustments ······················································ 6-6 4. Switch check (2) ···························································· 6-40
3. Subjects ··········································································· 6-6 5. Switch check (3) ···························································· 6-40
4. Preparing the Flash Adjustment Box ······························· 6-7 6. Switch check (3) ···························································· 6-41
1-2. INITIALIZATION OF 0E, 2F, 4F, 5F, 6F PAGE 7. LED check ····································································· 6-41
DATA ··············································································· 6-8 8. Record of Use check ······················································ 6-41
1-2-1. INITIALIZATION OF 2F PAGE DATA ························· 6-8 9. Self Diagnostics Log check ··········································· 6-41
1. Initializing the 2F Page Data ··········································· 6-8
2. 2F Page Table ·································································· 6-8 * Color reproduction frame and AF illumination frame are
1-2-2. Initializing the 4F Page Data ··········································· 6-9 shown on page 6-42.
1. Initializing the 4F Page Data ··········································· 6-9
2. 4F Page Table ·································································· 6-9
1-2-3. Initializing the 6F Page Data ········································· 6-10 Adjustments of DDX-G3000 COMPLETE ASSEMBLY
1. Initializing the 6F Page Data ········································· 6-10 are not shown. Pages from 6-45 to 6-75 are not shown.
2. 6F Page Table ································································ 6-10
1-2-4. INITIALIZATION OF 0E PAGE DATA ······················· 6-13
1. Initializing the 0E Page Data ········································· 6-13
2. 0E Page Table ································································ 6-13
1-2-5. INITIALIZATION OF 5F PAGE DATA ······················· 6-13
1. Initializing the 5F Page Data ········································· 6-13
2. 5F Page Table ································································ 6-13
1-3. VIDEO SYSTEM ADJUSTMENTS ····························· 6-14
1. Video Output Level Adjustment (SY-086 board) ·········· 6-14
1-4. CAMERA SYSTEM ADJUSTMENTS ························ 6-15
1. Data Setting during Camera System Adjustments ········ 6-15
2. Flange Back Adjustment (Using Minipattern Box) ······· 6-16
3. Flange Back Check ························································ 6-17
4. Picture Frame Setting ···················································· 6-18
5. F No. Standard Data Input ············································· 6-19
6. Mechanical Shutter Adjustment ···································· 6-19
7. Light Value Adjustment ················································· 6-20
8. Auto White Balance 3200K Standard Data Input ········· 6-21
9. Auto White Balance 5800K Standard Data Input ········· 6-21
10. Auto White Balance 5800K Check ······························· 6-22
11. Auto White Balance 3200K Check ······························· 6-22
12. Color Reproduction Adjustment ···································· 6-23
13. Color Reproduction Check ············································ 6-24
14. CCD White Defect Compensation Check ····················· 6-25
15. CCD Black Defect Compensation Check ····················· 6-26
16. Strobe Adjustment ························································· 6-27
17. AF Laser Output Adjustment ········································ 6-28
18. AF Laser Axis Check ···················································· 6-29
1-5. LCD SYSTEM ADJUSTMENTS ································· 6-30
1. LCD Type Check ··························································· 6-30
2. LCD Initial Data Input (1) ············································· 6-31
3. LCD Initial Data Input (2) ············································· 6-31
4. Back Light Adjustment (PK-068 board) ······················· 6-32
5. VCO Adjustment (PK-068 board) ································· 6-32
6. D Range Adjustment (PK-068 board) ··························· 6-33
7. Contrast Adjustment (PK-068 board) ···························· 6-33
8. V COM Level Adjustment (PK-068 board) ·················· 6-34
9. V COM Adjustment (PK-068 board) ···························· 6-34
10. White Balance Adjustment (PK-068 board) ·················· 6-35
1-6. SYSTEM CONTROL SYSTEM ADJUSTMENT ········ 6-36
1. Battery End Adjustment (SY-086 board) ······················· 6-36
2. Serial No. Input ····························································· 6-37

—2—
MVC-CD500

COVER SECTION 6
ADJUSTMENTS

1. Before starting adjustment

EVR Data Re-writing Procedure When Replacing Board


The data that is stored in the repair board, is not necessarily correct.
Perform either procedure 1 or procedure 2 or procedure 3 when replacing board.

Procedure 1
Save the EVR data of the machine in which a board is going to be replaced. Download the saved data after a board
is replaced.
(Machine before starting repair) (Machine after a board is replaced)
PC PC

Save the EVR data Download the saved


to a personal computer. data to a machine.

Procedure 2
Remove the EEPROM from the board of the machine that is going to be repaired. Install the removed EEPROM
to the replaced board.
Remove the EEPROM and install it.

(Former board) (New board)

Procedure 3
When the data cannot be saved due to defective EEPROM, or when the EEPROM cannot be removed or
installed, save the data from the same model of the same destination, and download it.

(Machine to be repaired) PC (Machine to be repaired)

Download the data.

Save the data.

(The same model of the same destination)

After the EVR data is saved and downloaded, check the


respective items of the EVR data.
(Refer to page 6-2 for the items to be checked.)

6-1
MVC-CD500

COVER

1-1. Adjusting items when replacing main parts and boards.


• Adjusting items when replacing main parts
When replacing main parts, adjust the items indicated by z in the following table.
Note1: When replacing the base unit, reset the data of page: 4F, address: AC to AF to “00”. (Refer to “Record of Use check” of “6-2. SERVICE MODE”)
Note2: Refer to “ADJUSTMENT (DDX-G3000 COMPLETE ASSEMBLY” of LEVEL3.

Replaced parts Board EEPROM


Block replacement Mounted parts replacement replacement replacement

PK-068 board IC302 (Timing generator) (LCD)


PK-068 board IC301 (RGB drive) (LCD)
SY-086 board IC301 (CAMERA DSP)
CD-439 board IC502 (S/H, AGC,A/D)
CD-439 board IC401 (CCD imager)

SY-086 board IC201 (Video amp.)

SY-086 board IC504 (EEPROM)


LCD block LCD unit (LCD901)

CD-439 board (COMPLETE)


PK-068 board (COMPLETE)
SY-086 board (COMPLETE)
Adjustment Section Adjustment

LCD block Back light unit


Base unit Note1
AF laser unit
Lens device
Flash unit

Initialization of 0E, 2F, 3E, Initialization of 0E, 2F, 3E, 3F, 4F,
3F, 4F, 5F, 6F page data 5F, 6F page data z z
Video Video output level adj. z z z z
Flange back adj. z z z z z
F No. standard data Input z z z z z
Mechanical shutter adj. z z z z z
Light value adj. z z z z z z
AWB 3200K standard data input z z z z z z
Camera AWB 5800K standard data input z z z z z z
Color reproduction adj. z z z z z z
CCD white defect compensation check z z z z z z
CCD black defect compensation check z z z z z z
Strobe adj. z z z z z z z
AF laser output adj. z z z
LCD initial data input z z z
Back light Adj. z z z z
VCO adj. z z z z z
D range adj. z z z z
LCD
Contrast adj. z z z z z
V COM Level adj. z z z z
V COM adj. z z z z z
White balance adj. z z z z z z
Battery end adj. z z
System control
Serial No. Input z z
Base unit. Note2 z z z
Table. 6-1-1.

6-2
MVC-CD500
Ver 1.1 2003. 05
COVER

6-1. ADJUSTMENT
1-1. PREPARATIONS BEFORE ADJUSTMENT

1-1-1. List of Service Tools


• Oscilloscope • Color monitor • Vectorscope • AC power adapter
• Regulated power supply • Digital voltmeter • Frequency counter
• Calculator which can hexadecimal calculation.

Ref. No. Name Parts Code Usage


Auto white balance adjustment/check
J-1 Filter for color temperature correction (C14) J-6080-058-A
White balance adjustment/check
J-2 Pattern box PTB-450 J-6082-200-A
J-3 Color chart for pattern box J-6020-250-A
J-4 Siemens star chart J-6080-875-A For checking the flange back
J-5 Clear chart for pattern box J-6080-621-A
J-6 Mini pattern box J-6082-353-B For adjusting the flange back
J-7 Camera table J-6082-384-A For adjusting the flange back
Personal computer with Windows98/ME/XP
J-8 installed and with two USB ports
J-9 USB cable 1-823-932-11 For connecting the personal computer
Application for adjustment (SEUS) Contact our service headquarter of each area how to get
J-10
and HASP key the application for adjustment (SEUS) and HASP key
J-11 Background paper J-2501-130-A For adjusting the strobe
J-14 Alignment disc J-6082-512-A For Base unit inspection

J-1 J-2 J-3 J-4 J-5

J-6 J-7 J-8 J-9 J-10

J-11 J-14

Fig. 6-1-1.

6-3
MVC-CD500

1-1-2. Preparations
Pattern box
1) Connect the equipment for adjustments according to Fig. 6-1-4.
2) Start up the application for adjustment (SEUS).

Note1: Setting the “Forced Power ON Mode (Forced STILL Mode)”


1) Select page: 00, address: 01, and set data: 01.
2) Select page: 2F, address: 21, and write data: 07. 30 cm
The above procedure will enable the power (STILL mode) to
be turned on with POWER switch (SY-086 board CN720)
disconnected. After completing adjustments, be sure to exit the
“Forced Power ON Mode”.
Note2: Setting the “Forced Power ON Mode (Forced PLAY Mode)”
1) Select page: 00, address: 01, and set data: 01.
2) Select page: 2F, address: 21, and write data: 08.
The above procedure will enable the power (PALY mode) to be
Front of the lens
turned on with POWER switch (SY-086 board CN720)
disconnected. After completing adjustments, be sure to exit the
“Forced Power ON Mode”.

Note3: Exiting the “Forced Power ON Mode”


1) Select page: 00, address: 01, and set data: 01.
2) Select page: 2F, address: 21, and write data: 00. Fig. 6-1-2.
3) Select page: 00, address: 01, and set data: 00.

1-1-3. Discharging of the flashlight power supply


The capacitor which is used as power supply of flashlight is charged
with 200V to 300V voltage. Discharge this voltage before starting
adjustments in order to protect service engineers from electric shock
during adjustment.

Discharge procedure
1. Remove the power supply (AC power adaptor or battery).
2. Fabricate the discharging jig as shown in Fig. 6-1-3. locally by 9
-43
yourself. Connect the discharging jig to the positive (+) and CD
negative (–) terminal of the flash voltage charge capacitor. Allow Tapping screw
ten seconds to discharge the voltage. (M1.7 × 5)
Short jig

Capacitor
Fig. 6-1-3.

6-4
MVC-CD500

[CONNECTION OF THE EQUIPMENT]


AC power AC IN
DC IN adaptor

Monitor TV

AV OUT

USB2 HASP key

USB1

Personal computer
(with two USB ports)

Fig. 6-1-4.

6-5
MVC-CD500

1-1-4. Precaution
1. Setting the Switch
Unless otherwise specified, set the switches as follows and perform adjustments.

Switch settings
1. Mode dial ............................................. STILL (P AUTO) (P) 5. EV .................................................................................... OFF
2. ZOOM .................................................................... WIDE end MENU settings
3. MACRO ( ) .................................................................. ON WHITE BAL ........................................................... AUTO
4. FOCUS ......................................................................... AUTO

2. Order of Adjustments
Basically carry out adjustments in the order given.

Color bar chart (Standard picture frame)


H
Yellow

Magenta
White
Cyan
Green

C C=D D
Red
Blue

Magenta
Yellow

Green
White
Cyan

Blue
Red
Picture frame

V
A B A Fig. b LCD screen or under scan
A= B Enlargement monitor TV picture
2
Fig. a
Video terminal
output waveform Difference in level

Adjust the camera position and direction to


obtain the output waveform shown in Fig. a
A and the LCD screen or the monitor TV
display shown in Fig. b.

Fig.6-1-5.

3. Subjects
1) Color bar chart (Standard picture frame)
When performing adjustments using the color bar chart, adjust
the picture frame as shown in Fig. 6-1-5. (Standard picture
frame)
2) Clear chart (Color reproduction adjustment frame)
Remove the color bar chart from the pattern box and insert a
clear chart in its place. (Do not perform zoom operations during
this time.)

6-6
MVC-CD500

4. Preparing the Flash Adjustment Box


A dark room is required to provide an accurate strobe adjustment.
If it is not available, prepare the flash adjustment box as given below;

1) Provide woody board A, B and C of 15 mm thickness.

woody board A (2 sheets) woody board B (2 sheets) woody board C (1 sheet)

400 mm 370 mm 700 mm

513 mm 513 mm 700 mm

730 mm 700 mm

Fig. 6-1-6.

2) Apply black mat paint to one side of woody board A and B.


3) Attach background paper (J-2501-130-A) to woody board C.
4) Assemble so that the black sides and the background paper side
of woody board A, B and C are internal. (Fig. 6-1-7.)

woody board A

woody board B

woody board A

woody board B

woody board C

Fig. 6-1-7.

6-7
MVC-CD500

COVER

1-2. INITIALIZATION OF 0E, 2F, 4F, 5F, 6F PAGE 2. 2F Page Table


DATA Note: Fixed data-1: Initialized data. (Refer to “1. Initializing the 2F Page
Data”.)
Fixed data-2: Modified data. (Refer to “1. Initializing the 2F Page
1-2-1. INITIALIZATION OF 2F PAGE DATA Data”).

1. Initializing the 2F Page Data


Address Remark
Initial value
Adjusting page 2F 00 to 20
Adjusting Address 00 to 7F 21 00 Test mode
22 to 49 Fixed data-1
Initializing Method: 4A 80 Battery end adj.
1) Select page: 00, address: 01, and set data: 01. 4B 85
2) Click [Page Edit] on the SEUS screen to display the SEUS
4C A1
PAGE EDIT screen.
3) Click [Page] to display the INPUT PAGE screen, and input 4D B6
“2F”. 4E C1
4) Click [Preset Data Read] on the SEUS PAGE EDIT screen to 4F to 7F Fixed data-1
display the INPUT SETID screen.
5) Input “0A” and click [OK] to read the preset data. Table. 6-1-2.
6) On the SEUS PAGE EDIT screen, change the data of the “Fixed
data-2” address shown in the following table by manual input.
Note: New data for changing are not shown in the table because they
are different in destination. When changing the data, copy the
data built in the same model. If copy the data built in the different
model, the camera may not operate.
7) Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
8) Click [Write] to write the initializing data to the EEPROM of
the camera.
9) Click [Close] to close the SEUS PAGE EDIT screen.

Processing after Completing Initializing of 2F Page data


Order Page Address Data Procedure
1 20 00 29 Write the data.
2 20 01 29 Write the data.
3 Check “Receive Paket Error” is
displayed on the SEUS screen.
4 Wait for 15 sec.
5 Click [Connect] on the SEUS
screen.

6-8
MVC-CD500

1-2-2. Initializing the 4F Page Data 2. 4F Page Table


Note1: Fixed data-1: Initialized data. (Refer to “1. Initializing the 4F Page
1. Initializing the 4F Page Data Data”.)
Note: If the 4F page data has been initialized, the following adjustments Fixed data-2: Modified data. (Refer to “1. Initializing the 4F Page
need to be performed again. Data”).
1) Video system adjustments Note2: LCD TYPE S/ LCD TYPE C (Refer to “1-5. LCD SYSTEM
2) LCD system adjustments ADJUSTMENT”.)
Note3: Refer to page 6-41 “8. Record of Use check” of 6-2. SERVICE
MODE.
Adjusting page 4F
Adjusting Address 00 to FF
Address Remark
Initial value
Initializing Method: 00 to 7E Fixed data-1
1) Select page: 00, address: 01, and set data: 01. 80 60 Back light adj. (LCD)
2) Click [Page Edit] on the SEUS screen to display the SEUS
81 A8
PAGE EDIT screen.
3) Click [Page] to display the INPUT PAGE screen, and input 82 68/36 VCO adj. (LCD) (Note2)
“4F”. 83 7B/45
4) Click [Preset Data Read] on the SEUS PAGE EDIT screen to 84 80/8F V COM adj. (LCD) (Note2)
display the INPUT SETID screen. 85 60 D range adj. (LCD)
5) Input “0A” and click [OK] to read the preset data. 86 08 Fixed data (LCD)
6) On the SEUS PAGE EDIT screen, change the data of the “Fixed
87 A0/7F V COM level adj. (LCD) (Note2)
data-2” address shown in the following table by manual input.
Note: New data for changing are not shown in the table because they 88 9A/7C White balance adj. (Note2)
are different in destination. When changing the data, copy the 89 54/6F
data built in the same model. If copy the data built in the different 8A 4C/40 Contrast adj. (LCD)
model, the camera may not operate.
7) Check that the data of adjustment addresses is the initial value. 8B 00 Fixed data (LCD)
If not, change the data to the initial value. 8C to 91 Fixed data-1
8) Click [Write] to write the initializing data to the EEPROM of 92 30 Fixed data (LCD) (Note2)
the camera. 93 11/10
9) Click [Close] to close the SEUS PAGE EDIT screen. 94 9F
95 1F
Processing after Completing Initializing of 4F Page data
66 04/01
Order Page Address Data Procedure
97 to 9F Fixed data-1
1 20 00 29 Write the data.
A0 80 Video output level adj.
2 20 01 29 Write the data.
A1 to A2 Fixed data-1
3 Check “Receive Paket Error” is A3 23 Fixed data (LCD)
displayed on the SEUS screen.
A4 3E
4 Wait for 15 sec.
A5 to A7 Fixed data-1
5 Click [Connect] on the SEUS A8 Fixed data-2
screen.
A9
AA to AB Fixed data-1
AC 00 Recording counter (Hexadecimal)
AD 00 (Note3)
AE 00
AF 00
B0 to FF Fixed data-1
Table. 6-1-3.

6-9
MVC-CD500

1-2-3. Initializing the 6F Page Data 2. 6F Page Table


Note: Fixed data-1: Initialized data. (Refer to “1. Initializing the 6F Page
1. Initializing the 6F Page Data Data”.)
Note: If the 6F page data has been initialized, the following adjustments Fixed data-2: Modified data. (Refer to “1. Initializing the 6F Page
need to be performed again. Data”).
1) Camera system adjustments
Address Remark
Initial value
Adjusting page 6F 00 to 0F Fixed data-1
Adjusting Address 00 to FF 10 58 AF laser output adj.
11 FF
Initializing Method:
12 FF
1) Select page: 00, address: 01, and set data: 01.
2) Click [Page Edit] on the SEUS screen to display the SEUS 13 FF
PAGE EDIT screen. 14 00
3) Click [Page] to display the INPUT PAGE screen, and input 15 90
“6F”. 16 FF
4) Click [Preset Data Read] on the SEUS PAGE EDIT screen to 17 Fixed data-1
display the INPUT SETID screen.
18 33 Flange back Adj.
5) Input “0A” and click [OK] to read the preset data.
6) On the SEUS PAGE EDIT screen, change the data of the “Fixed 19 48
data-2” address shown in the following table by manual input. 1A DA
Note: New data for changing are not shown in the table because they 1B DF
are different in destination. When changing the data, copy the
1C 13
data built in the same model. If copy the data built in the different
model, the camera may not operate. 1D C0
7) Check that the data of adjustment addresses is the initial value. 1E 00
If not, change the data to the initial value. 1F 00
8) Click [Write] to write the initializing data to the EEPROM of 20 00
the camera.
21 00
9) Click [Close] to close the SEUS PAGE EDIT screen.
22 00
Processing after Completing Initializing of 6F Page data 23 00
Order Page Address Data Procedure 24 20
1 20 00 29 Write the data. 25 20
2 20 01 29 Write the data. 26 BA
27 46
3 Check “Receive Paket Error” is
displayed on the SEUS screen. 28 0A
4 Wait for 15 sec. 29 00
2A 00
5 Click [Connect] on the SEUS
screen. 2B 00
2C 00
2D 00
2E 00
2F 00
30 00
31 00
32 00
33 00
34 00
35 00
36 00
37 00
38 00
39 00
3A 00
3B 00
3C 00
3D 00
3E FF

6-10
MVC-CD500

6F Page

Address Remark Address Remark


Initial value Initial value
3F Fixed data-1 82 00 AWB 3200K standard data input
40 00 Flange back Adj. 83 00
41 00 84 00
42 00 85 00
43 00 86 00
44 00 87 00
45 00 88 19 AWB 5200K standard data input
46 00 89 66
47 00 8A 30
48 00 8B 6E
49 00 8C 19
4A 00 8D A7
4B 00 8E 32
4C 00 8F FB
4D 00 90 00
4E 00 91 00
4F 00 92 00
50 00 93 00
51 00 94 00
52 00 95 00
53 00 96 00
54 to 5F Fixed data-1 97 00
60 00 F No. standard data input 98 00
61 00 99 00
62 00 9A 00
63 00 9B 00
64 00 9C 00
65 30 Light value adj. 9D 00
66 FE 9E 00
67 6D 9F 00
68 to 6A Fixed data-1 A0 2A
6B FF F No. standard data input/ A1 80
6C 00 Mechanical shutter adj. A2 5E
6D 00 A3 C0
6E to 6F Fixed data-1 A4 03 Color reproduction adj.
70 29 AWB 3200K standard data input A5 E9
71 83 A6 63
72 1F A7 83
73 DF A8 D5
74 29 A9 FE
75 0C AA 73
76 22 AB 45
77 6D AC 63
78 00 AD 83
79 00 AE 03
7A 00 AF E9
7B 00 B0 00 AWB 3200K standard data input
7C 00 B1 00 AWB 5800K standard data input
7D 00 B2 00 AWB 3200K standard data input
7E 00 B3 00 AWB 5800K standard data input
7F 00 B4 00 AWB 3200K standard data input
80 00 B5 Fixed data-1
81 00 B6 28 Strobe adj.
B7 6E

6-11
MVC-CD500

6F Page

Address Remark Address Remark


Initial value Initial value
B8 10 Mechanical shutter adj. EE 00 Strobe adj.
B9 09 EF 00
BA 09 F0 to FF Fixed data-1
BB D4 Table. 6-1-4.
BC 08
BD 47
BE 08
BF 47
C0 08
C1 47
C2 00
C3 00
C4 00
C5 00
C6 00
C7 34
C8 46
C9 3E
CA 3E
CB 3E
CC 80
CD 88
CE 98
CF 90
D0 88
D1 00
D2 00
D3 00
D4 00
D5 00
D6 00
D7 14
D8 FF Strobe adj.
D9 FF
DA FF
DB 00
DC 00
DD 00
DE 00
DF 00
E0 00
E1 00
E2 00
E3 00
E4 00
E5 00
E6 00
E7 00
E8 00
E9 00
EA 00
EB 00
EC 00
ED 00

6-12
MVC-CD500

1-2-4. INITIALIZATION OF 0E PAGE DATA 1-2-5. INITIALIZATION OF 5F PAGE DATA

1. Initializing the 0E Page Data 1. Initializing the 5F Page Data

Adjusting page 0E Adjusting page 5F


Adjusting Address 00 to FF Adjusting Address 3A to 3F , 46 to 4B

Initializing Method: Initializing Method:


1) Select page: 00, address: 01, and set data: 01. 1) Select page: 00, address: 01, and set data: 01.
2) Click [Page Edit] on the SEUS screen to display the SEUS 2) Check that the addresses of the LCD fixed data are the initial
PAGE EDIT screen. value. If not, write the initial value.
3) Click [Page] to display the INPUT PAGE screen, and input 3) Write the serial number to the address 46 to 4B. (Refer to “2.
“0E”. Serial No. Input” of “1-6. SYSTEM CONTROL SYSTEM
4) Click [Preset Data Read] on the SEUS PAGE EDIT screen to ADJUSTMENT”.)
display the INPUT SETID screen. 4) Select page: 00, address: 01, and set data: 00.
5) Input “00” and click [OK] to read the preset data.
6) Click [Write] to write the initializing data to the EEPROM of 2. 5F Page Table
the camera. Note1: Fixed data-1: Initialized data.
7) Click [Close] to close the SEUS PAGE EDIT screen. Note2: Refer to “2. Serial No. Input” of “1-6. SYSTEM CONTROL
SYSTEM ADJUSTMENT”.)
Processing after Completing Initializing of 0E Page data
Address Remark
Order Page Address Data Procedure Initial value
1 20 00 29 Write the data. 00 to 39 Fixed data-1
2 20 01 29 Write the data. 3A 58 Fixed data (LCD)
3B FF
3 Check “Receive Paket Error” is
displayed on the SEUS screen. 3C 00
4 Wait for 15 sec. 3D 5A
5 Click [Connect] on the SEUS 3E 01
screen. 3F 00
40 to 45 Fixed data-1
2. 0E Page Table 46 00 Serial No. (Note2)
Note: Fixed data-1: Initialized data. (Refer to “1. Initializing the 0E Page 47 00
Data”.)
48 00
Address Remark 49 00
4A 00
00 to FF Fixed data-1
4B 00
Table. 6-1-5. 40 to FF Fixed data-1
Table. 6-1-6.

6-13
MVC-CD500

COVER

1-3. VIDEO SYSTEM ADJUSTMENTS

1. Video Output Level Adjustment (SY-086 board)


Adjust the sync level of the composite video signal output.
Mode PLAY ( )
Subject Arbitrary
Measurement Point Video terminal of AV OUT jack
(75Ω terminated)
Measuring Instrument Oscilloscope
Adjustment Page 4F
Adjustment Address A0
Specified Value Sync level:
A=286 ± 5mV (NTSC mode)
A=300 ± 5mV (PAL mode)
Burst level:
B=286 ± 30mV (NTSC mode)
B=300 ± 30mV (PAL mode)

SETUP setting:
VIDEO OUT (SETUP 2)
.............................................................. NTSC (NTSC mode)
.................................................................... PAL (PAL mode)

Adjusting method:
Order Page Address Data Procedure
1 00 01 01 Set the data.
2 60 C1 Read the data, and check it is
“01”.
3 4F 02 03 Write the data.
4 40 F1 04 Set the data.
5 4F A0 Change the data and set the sync
level (A) to the specified value.
6 4F A0 Write the data.
7 Check that the burst level (B)
satisfies the specified value.
8 4F 02 00 Write the data.
B
9 40 F1 00 Set the data.
A
10 00 01 00 Set the data.

Fig.6-1-8.

6-14
MVC-CD500

COVER

1-4. CAMERA SYSTEM ADJUSTMENTS

Note: Perform the camera system adjustments by using the application


for adjustment (SEUS).

1. Data Setting during Camera System Adjustments


Perform the following data setting before the camera system
adjustments.
Note1: When the power is turned off, some data settings will be released.
So perform this data setting again when the power is turned off.

Order Page Address Data Procedure


1 00 01 01 Set the data.
2 4F 0F 03 Write the data.
3 2F 21 07 Write the data.
4 60 C1 Read the data, and check it is
“02”.
5 4F 02 02 Write the data.
6 60 6C 01 Write the data.
7 60 2C 01 Write the data.
8 4F 01 20 Write the data.
9 7F 68 00 Write the data.
10 7F E9 3F Write the data.
11 7F EB 44 Write the data.
12 7D D0 0D Write the data.
13 73 1A 00 Write the data.
14 73 1B 00 Write the data.
15 73 1C 00 Write the data.

After completing the camera system adjustments, release the data


setting.
Order Page Address Data Procedure
1 00 01 01 Set the data.
2 4F 0F 02 Write the data.
3 4F 02 00 Write the data.
4 4F 01 00 Write the data.
5 2F 21 00 Write the data.
6 7F 68 40 Write the data.
7 00 01 00 Set the data.
8 Initialize the OE page data.
(Note2)

Note2: Refer to “1-2-4. INITIALIZATION OF 0E PAGE DATA”.

6-15
MVC-CD500

2. Flange Back Adjustment


(Using Minipattern Box)
The inner focus lens flange back adjustment is carried out
automatically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
Mode STILL(P AUTO) (P)
Subject Siemens star chart with ND filter for
the minipattern box (Note1)
Measurement Point Data of page: 6F, address: 24, 3E
Measuring Instrument
Adjustment Page 6F
Adjustment Address 18 to 3E, 40 to 53
Specified value1 00
Specified value2 0A to 40

Note1: Dark siemens star chart.


Note2: If the data of page: 60, address: 02 is “01”, select page: 60, address:
01, and write data: 00.

Preparations: Adjusting method:


1) The minipattern box is installed as shown in the following Order Page Address Data Procedure
figure. 1 Check that “1. Data Setting during
Note: The attachment lenses are not used.
Camera System Adjustments” is
2) Install the minipattern box so that the distance between it and
performed.
the front of the lens of the camera is less than 3cm.
3) Make the height of the minipattern box and the camcorder equal. 2 00 01 01 Set the data.
4) Check that the output voltage of the regulated power supply is 3 60 01 13 Write the data.
the specified voltage. 4 60 01 27 Write the data.
5) Check that at both the zoom lens TELE end and WIDE end,
5 Wait until the movement of the
the center of the siemens star chart and center of the exposure
lens stops.
screen coincide.
6 60 02 Read the data, and check it is
Specified voltage: The specified voltage varies according to the “01”. (Note3)
minipattern box, so adjust the power supply 7 6F 3E Read the data, and check it
output voltage to the specified voltage written satisfies the specified value 1.
on the sheet which is supplied with the 8 6F 24 Read the data, and check it
minipattern box. satisfies the specified value 2.

Note3: The adjustment data will be automatically input to page: 6F,


Below 3 cm
address: 18 to 3E, 40 to 53.
Minipattern box
Processing after Completing Adjustments:
Camera Order Page Address Data Procedure
1 60 01 00 Write the data.
Camera 2 Turn off the power and turn on
table
again.
Regulated power supply 3 Perform “Flange Back Check”.
Output voltage : Specified voltage ±0.01Vdc
Output current : more than 3.5A 4 If finish the camera system
adjustments, release the data
setting.
(See “1. Data Setting during
Red (+)
Camera System Adjustments”.)
Black (–)

Yellow (SENS +)

White (SENS –) Need not connected


Black (GND)

Fig.6-1-9.

6-16
MVC-CD500

3. Flange Back Check

Mode STILL(P AUTO) (P)


Subject Siemens star
(1.0m from the front of the lens)
(Luminance : approx. 300 lux)
Measurement Point Check operation on TV monitor
Measuring Instrument
Specified Value The lens is focused.

Checking method:
Order Page Address Data Procedure
1 Place the siemens star 1.0 m
from the front of the lens.
2 60 2C 00 Set the data.
3 60 8C 30 Check that the lens is focused.
4 5F 3D 50 Set the data.
5 Shoot the Siemens star with the
zoom TELE end.
6 Adjust the direction of the camera
so that the Siemens star is located
in the center of the screen.
7 Check that the lens is focused.
8 60 2C 01 Set the data.
9 Shoot the Siemens star with the
zoom WIDE end.
10 Check that the lens is focused.

Processing after Completing Adjustments:


Order Page Address Data Procedure
1 5F 3D 5A Check the data. (Note)
2 60 8C 00 Set the data.

Note: Operation to release the data setting.

6-17
MVC-CD500

4. Picture Frame Setting

Mode STILL(P AUTO) (P)


Subject Color bar chart and clear chart
(Standard picture frame)
About 30cm from the front of the lens
Measurement Point Video terminal of A/V OUT jack Check on an oscilloscope
Measuring Instrument Oscilloscope and TV monitor
1. Horizontal period
Specified Value A=C=B/2, E=F
B
Switch setting: A=C=
2
ZOOM .................................................................... WIDE end A C
B
Setting method:
Order Page Address Data Procedure
1 Check that “1. Data Setting during
Camera System Adjustments” is
performed.
2 Shoot the color bar chart with
the zoom WIDE end.
3 Adjust the direction and distance
between the pattern box and
camera, and set the picture frame
to the specified position.
4 Remove the color bar chart and
set the clear chart.
5 Check that the whole of the screen
is white. If not, adjust the direction
and distance slightly.
6 10 44 Read the data, and this data Fig. 6-1-10.
named YH.
2. Vertical period
7 10 45 Read the data, and this data
named YL. E E=F F
8 60 2C 01 Write the data.
9 Perform the following adjustments.

How to reset the zoom and focus when they deviated:


If the zoom and focus deviated due to some reason reset them in the V
following method.
Order Page Address Data Procedure Fig. 6-1-11.
1 60 90 00 Write the data.
Check on the monitor TV (Underscanned mode)
2 60 91 00 Write the data.
3 60 92 YL Write the data. (Note) A B C
4 60 93 YH Write the data. (Note)
5 60 01 79 Write the data.
6 Wait until the movement of the
lens stops.
7 60 07 Read the data, and check it is
“01”.
8 60 01 00 Write the data.

Note: YH and YL are the data read in the “Setting method”.

Color bar chart picture frame Effective picture frame

Fig. 6-1-12.

6-18
MVC-CD500

5. F No. Standard Data Input 6. Mechanical Shutter Adjustment


Adjusted the dispersion of the iris to every to every F number, and Adjust the dispersion of the opening/closing time and the closing
compensate the exposure. loss rate of the mechanical shutter. and compensate the exposure.
Mode STILL(P AUTO) (P) Mode STILL(P AUTO) (P)
Subject Clear chart (Standard picture frame) Subject Clear chart (Standard picture frame)
Measurement Point Data of page: 6F, address: 6B Measurement Point Data of page: 6F, address: 6B
Measuring Instrument Measuring Instrument
Adjustment Page 6F Adjustment Page 6F
Adjustment Address 60 to 64, 6B to 6D Adjustment Address 6B to 6D, B8 to D7
Specified value 00 Specified value 00

Note1: If the data of page: 60, address: 02 is “01”, select page: 60, address: Note1: If the data of page: 60, address: 02 is “01”, select page: 60, address:
01, and write data: 00. 01, and write data: 00.

Switch setting: Switch setting:


ZOOM .................................................................... WIDE end ZOOM .................................................................... WIDE end

Adjusting method: Adjusting method:


Order Page Address Data Procedure Order Page Address Data Procedure
1 Check that “1. Data Setting during 1 Check that “1. Data Setting during
Camera System Adjustments” is Camera System Adjustments” is
performed. performed.
2 Check the picture frame. If 2 Check the picture frame. If
deviated, perform “4. Picture deviated, perform “4. Picture
Frame Setting”. Frame Setting”.
3 00 01 01 Set the data. 3 00 01 01 Set the data.
4 60 01 BB Write the data. 4 60 01 AD Write the data.
5 Wait for 10 sec. 5 Wait until the movement of the
6 60 02 Read the data, and check it is shutter stops.
“01”. (Note2) 6 60 02 Read the data, and check it is
7 6F 6B Read the data, and check it “01”. (Note2)
satisfies the specified value. 7 6F 6B Read the data, and check it
satisfies the specified value.
Note2: The adjustment data will be automatically input to page: 6F,
address: 60 to 64, 6B to 6D. Note2: The adjustment data will be automatically input to page: 6F,
address: 6B to 6D, B8 to D7.
Processing after Completing Adjustments:
Processing after Completing Adjustments:
Order Page Address Data Procedure
Order Page Address Data Procedure
1 60 01 00 Write the data.
1 60 01 00 Write the data.
2 If finish the camera system
adjustments, release the data 2 If finish the camera system
setting. adjustments, release the data
(See “1. Data Setting during setting.
Camera System Adjustments”.) (See “1. Data Setting during
Camera System Adjustments”.)

6-19
MVC-CD500

7. Light Value Adjustment


Adjust the standard LV value.
Mode STILL(P AUTO) (P)
Subject Clear chart (Standard picture frame)
Measurement Point Data of page: 10, address: 0C, 0D
Measuring Instrument Data of page: 6F, address: 65
Data of page: 6F, address: 6B
Adjustment Page 6F
Adjustment Address 65 to 67
Specified value1 0FE0 to 1020
Specified value2 38 to 4E

Note1: If the data of page: 60, address: 02 is “01”, select page: 60, address:
01, and write data: 00.

Switch setting:
ZOOM .................................................................... WIDE end

Adjusting method:
Order Page Address Data Procedure
1 Check that “1. Data Setting during
Camera System Adjustments” is
performed.
2 Check the picture frame. If
deviated, perform “4. Picture
Frame Setting”.
3 00 01 01 Set the data.
4 60 12 9C Write the data.
5 60 01 0D Write the data.
6 Wait for 3 sec.
7 60 02 Read the data, and check it is “01”.
(Note2)
8 10 0C Read the data, and this data is
named D0C.
9 10 0D Read the data, and this data is
named D0D.
10 Calculate DLV using the
following equation
(Hexadecimal calculation)
DLV = D0C ×100 + D0D
11 Check that DLV satisfies the
specified value1.
12 6F 65 Read the data, and check it
satisfies the specified value2.
13 6P 6B Read the data, and check it
satisfies the specified value.
14 60 12 00 Write the data.

Note2: The adjustment data will be automatically input to page: 6F,


address: 65 to 67.

Processing after Completing Adjustments:


Order Page Address Data Procedure
1 60 01 00 Write the data.
2 If finish the camera system
adjustments, release the data
setting.
(See “1. Data Setting during
Camera System Adjustments”.)

6-20
MVC-CD500

8. Auto White Balance 3200K Standard Data Input 9. Auto White Balance 5800K Standard Data Input
Adjust the white balance standard data at 3200K. Adjust the white balance standard data at 5800K.
Mode STILL(P AUTO) (P) Mode STILL(P AUTO) (P)
Subject Clear chart (Standard picture frame) Subject Clear chart (Standard picture frame)
Measurement Point Data of page: 6F, address: B5 Filter Filter C14 for color temperature
Measuring Instrument correction
Adjustment Page 6F Measurement Point Data of page: 6F, address: B5
Adjustment Address 70 to 87, B0, B2, B4 Measuring Instrument
Specified value 00 Adjustment Page 6F
Adjustment Address 88 to A3, B1, B3
Note1: If the data of page: 60, address: 02 is “01”, select page: 60, address: Specified value 00
01, and write data: 00.
Note1: Before perform this adjustment, perform “Auto White Balance
Switch setting: 3200K Standard Data Input”.
ZOOM .................................................................... WIDE end Note2: If the data of page: 60, address: 02 is “01”, select page: 60, address:
01, and write data: 00.
Adjusting method:
Order Page Address Data Procedure Switch setting:
ZOOM .................................................................... WIDE end
1 Install the clear chart.
2 Check that “1. Data Setting during Adjusting method:
Camera System Adjustments” is Order Page Address Data Procedure
performed.
1 Place the C14 filter for color
3 Check the picture frame. If
temperature correction on the lens.
deviated, perform “4. Picture
Frame Setting”. 2 Check that “1. Data Setting during
Camera System Adjustments” is
4 00 01 01 Set the data. performed.
5 6F B5 FF Write the data.
3 Check the picture frame. If
6 60 01 0B Write the data. deviated, perform “4. Picture
7 Wait for 20 sec. Frame Setting”.
8 60 02 Read the data, and check it is “01”. 4 00 01 01 Set the data.
(Note2) 5 6F A0 2A Write the data.
9 6F B5 Read the data, and check it 6 6F A1 C0 Write the data.
satisfies the specified value.
7 6F A2 5E Write the data.
Note2: The adjustment data will be automatically input to page: 6F, 8 6F A3 60 Write the data.
address: 70 to 87, B0, B2, B4. 5800K standard data input
9 6F B5 FF Write the data.
Processing after Completing Adjustments:
10 60 01 A5 Write the data.
Order Page Address Data Procedure
11 Wait for 20 sec.
1 60 01 00 Write the data.
12 60 02 Read the data, and check it is “01”.
2 Perform next “Auto White
(Note2)
Balance 5800K Standard Data
Input”. 13 6F B5 Read the data, and check it
If finish the camera system satisfies the specified value.
adjustments, release the data
Note3: The adjustment data will be automatically input to page: 6F,
setting.
address: 88 to A3, B1, B3.
(See “1. Data Setting during
Camera System Adjustments”.) Processing after Completing Adjustments:
Order Page Address Data Procedure
1 60 01 00 Write the data.
2 Perform next “Auto White
Balance 5800K Check”.
If finish the camera system
adjustments, release the data
setting.
(See “1. Data Setting during
Camera System Adjustments”.)

6-21
MVC-CD500

10. Auto White Balance 5800K Check 11. Auto White Balance 3200K Check
Check that the white balance standard data at 5800K are inputted Check that the white balance standard data at 3200K are inputted
properly. properly.
Mode STILL(P AUTO) (P) Mode STILL(P AUTO) (P)
Subject Clear chart (Standard picture frame) Subject Clear chart (Standard picture frame)
Filter Filter C14 for color temperature Measurement Point Data of page: 6F, address: B5
correction Measuring Instrument
Measurement Point Data of page: 6F, address: B5 Specified value 00
Measuring Instrument
Note: If the data of page: 60, address: 02 is “01”, select page: 60, address:
Specified value 00
01, and write data: 00.

Note1: Before perform this adjustment, perform “Auto White Balance Switch setting:
5800K Standard Data Input”. ZOOM .................................................................... WIDE end
Note2: If the data of page: 60, address: 02 is “01”, select page: 60, address:
01, and write data: 00.
Adjusting method:
Switch setting: Order Page Address Data Procedure
ZOOM .................................................................... WIDE end 1 Check that “1. Data Setting during
Camera System Adjustments” is
Adjusting method: performed.
Order Page Address Data Procedure 2 Check the picture frame. If
1 Place the C14 filter for color deviated, perform “4. Picture
temperature correction on the lens. Frame Setting”.
2 Check that “1. Data Setting during 3 00 01 01 Set the data.
Camera System Adjustments” is 5800K standard data Check
performed. 4 6F B5 FF Write the data.
3 Check the picture frame. If 5 60 01 0F Write the data.
deviated, perform “4. Picture
Frame Setting”. 6 Wait for 30 sec.
4 00 01 01 Set the data. 7 60 02 Read the data, and check it is “01”.
5800K standard data Check 8 6F B5 Read the data, and check it
satisfies the specified value.
5 6F B5 FF Write the data.
6 60 01 3F Write the data. Processing after Completing Adjustments:
7 Wait for 30 sec. Order Page Address Data Procedure
8 60 02 Read the data, and check it is “01”. 1 60 01 00 Write the data.
9 6F B5 Read the data, and check it 2 Perform next adjustments.
satisfies the specified value. If finish the camera system
adjustments, release the data
Processing after Completing Adjustments: setting.
Order Page Address Data Procedure (See “1. Data Setting during
1 60 01 00 Write the data. Camera System Adjustments”.)
2 Remove the C14 filter.
3 Perform next adjustments.
If finish the camera system
adjustments, release the data
setting.
(See “1. Data Setting during
Camera System Adjustments”.)

6-22
MVC-CD500

12. Color Reproduction Adjustment


Adjust the color Separation matrix coefficient so that proper color
reproduction is produced.
Mode STILL(P AUTO) (P)
Subject Color bar chart
(Standard picture frame)
Measurement Point Data of page: 6F, address: B5
Measuring Instrument
Adjustment Page 6F
Adjustment Address A4 to AF
Specified value 00

Note1: If the data of page: 60, address: 02 is “01”, select page: 60, address:
01, and write data: 00.

Switch setting:
ZOOM .................................................................... WIDE end
VIDEO OUT (SET UP setting) .................................... NTSC

Adjusting method: Processing after Completing Adjustments:


Order Page Address Data Procedure Order Page Address Data Procedure
1 Install the color bar chart. 1 60 01 00 Write the data.
2 Check that “1. Data Setting during 2 7F 68 40 Check the data. (Note3)
Camera System Adjustments” is 3 Perform next adjustments.
performed. If finish the camera system
3 Check the picture frame. If adjustments, release the data
deviated, perform “4. Picture setting.
Frame Setting”. (See “1. Data Setting during
4 00 01 01 Set the data. Camera System Adjustments”.)
5 7F 68 00 Set the data.
Note3: Operation to release the data setting.
6 6F B5 FF Write the data.
7 60 01 AB Write the data.
8 60 12 80 Write the data.
9 Wait for 1 sec.
10 60 12 00 Write the data.
11 Wait for 2 sec.
12 60 01 A9 Write the data.
13 Wait until the color of the screen
stops changing.
14 60 02 Read the data, and check it is “01”.
(Note2)
15 6F B5 Read the data, and check it
satisfies the specified value.

Note2: The adjustment data will be automatically input to page: 6F,


address: A4 to AF.

6-23
MVC-CD500

13. Color Reproduction Check


Check that the color reproduction adjustment is done properly.
Mode STILL(P AUTO) (P)
Subject Color bar chart
(Standard picture frame)
Measurement Point Video terminal of A/V OUT jack
Measuring Instrument NTSC vectorscope
Specified Value Each center of all color luminance
points should settle within each color
reproduction frame.

Note1: If the data of page: 60, address: 02 is “01”, select page: 60, address:
01, and write data: 00.

Switch setting:
ZOOM .................................................................... WIDE end
VIDEO OUT (SET UP setting) .................................... NTSC

Checking method:
Order Page Address Data Procedure
1 Check that “1. Data Setting during
Camera System Adjustments” is
performed.
2 Check the picture frame. If
deviated, perform “4. Picture White
Frame Setting”.
3 00 01 01 Set the data.
4 7F 68 00 Set the data.
5 60 01 AB Write the data.
6 60 12 80 Write the data.
7 Wait for 1 sec.
8 60 12 00 Write the data.
9 Wait for 2 sec.
10 Adjust the GAIN and PHASE of
the vectorscope so that the burst
luminance point is set at the
specified position. Burst position
11 Check that each center of all color
luminance points is set in each
Fig. 6-1-13.
color reproduction frame.

Processing after Completing Adjustments:


Order Page Address Data Procedure
1 60 01 00 Write the data.
2 7F 68 40 Check the data. (Note2)
3 Perform next adjustments.
If finish the camera system
adjustments, release the data
setting.
(See “1. Data Setting during
Camera System Adjustments”.)

Note2: Operation to release the data setting.

6-24
MVC-CD500

14. CCD White Defect Compensation Check


The positions of the white defective pixel are detected, and check
that the pixels can be corrected.
Mode STILL(P AUTO) (P)
Subject Clear chart (Standard picture frame)
Measurement Point Data of page: 60, address: 55
Measuring Instrument
Specified value 1 00 to 7F
Specified value 2 00

Note1: If the data of page: 60, address: 02 is “01”, select page: 60, address:
01, and write data: 00.

Switch setting:
ZOOM .................................................................... WIDE end

Adjusting method:
Order Page Address Data Procedure
1 Install the clear chart.
2 Check that “1. Data Setting during
Camera System Adjustments” is
performed.
3 Check the picture frame. If
deviated, perform “4. Picture
Frame Setting”.
4 00 01 01 Set the data.
5 7D 64 1E Set the data.
6 7D 69 16 Set the data.
7 60 01 8B Write the data.
8 Wait for 5 sec.
9 60 02 Read the data, and check it is “01”.
10 60 55 Read the data, and check it
satisfies the specified value 1.
11 60 01 00 Write the data.
12 7D 64 0F Set the data.
13 7D 69 60 Set the data.
14 60 01 87 Write the data.
15 Wait for 5 sec.
16 60 02 Read the data, and check it is “01”.
17 60 55 Read the data, and check it
satisfies the specified value 2.

Processing after Completing Adjustments:


Order Page Address Data Procedure
1 60 01 00 Write the data.
2 7D 64 0F Check the data. (Note2)
3 7D 69 0B Check the data. (Note2)
4 Perform next adjustments.
If finish the camera system
adjustments, release the data
setting.
(See “1. Data Setting during
Camera System Adjustments”.)

Note2: Operation to release the data setting.

6-25
MVC-CD500

15. CCD Black Defect Compensation Check


The positions of the black defective pixel are detected, and check
that the pixels can be corrected. And confirms that there is no trash
in the surface of the CCD imager, the optical filter and the inside of
the lens.
Mode STILL(P AUTO) (P)
Subject Clear chart (Standard picture frame)
Measurement Point Data of page: 60, address: 55
Measuring Instrumen
Specified value 1 00 to 14
Specified value 2 00

Note1: Check that there are no dust, no dirt and no reflection on the clear
chart.
Note2: If the data of page: 60, address: 02 is “01”, select page: 60, address:
01, and write data: 00.

Switch setting:
ZOOM .................................................................... WIDE end

Adjusting method: Processing after Completing Adjustments:


Order Page Address Data Procedure Order Page Address Data Procedure
1 Check that “1. Data Setting during 1 60 01 00 Set the data.
Camera System Adjustments” is 2 60 30 00 Set the data.
performed.
3 60 91 00 Set the data.
2 Check the picture frame. If
4 7D 65 4C Check the data. (Note3)
deviated, perform “4. Picture
Frame Setting”. 5 Perform next adjustments.
If finish the camera system
3 00 01 01 Set the data.
adjustments, release the data
4 7D 65 4C Set the data. setting.
5 60 90 00 Set the data. (See “1. Data Setting during
6 60 91 03 Set the data. Camera System Adjustments”.)
7 60 92 00 Set the data.
Note3: Operation to release the data setting.
8 60 93 00 Set the data.
9 60 01 79 Write the data.
10 60 30 08 Set the data.
11 60 07 Read the data, and check it is “01”.
12 Check that the whole of the screen
is white.
13 60 01 8D Write the data.
14 Wait for 30 sec.
15 60 02 Read the data, and check it is “01”.
16 60 55 Read the data, and check it
satisfies the specified value 1.
If the data is “00”, proceed to
“Processing after Completing
Adjustments”
17 60 01 00 Write the data.
18 7D 65 5A Write the data.
19 60 01 89 Write the data.
20 Wait for about 30 sec.
21 60 02 Read the data, and check it is “01”.
22 60 55 Read the data, and check it
satisfies the specified value 2.

6-26
MVC-CD500

16. Strobe Adjustment Order Page Address Data Procedure


Adjust the light level and white balance when the strobe light flashes.
28 Check the flashing.
Mode STILL(P AUTO) (P)
29 60 02 Read the data, and check it is “01”.
Subject Background paper (J-250-130-A) (Note5)
(50cm from the front of the lens)
30 6F D8 Read the data, and check it is “00”.
Measurement Point Data of page: 60, address: D8, EA,
31 60 01 00 Write the data.
Measuring Instrumen EC, EE, B5
32 Wait for 5 sec.
Adjustment Page 6F
33 60 ED Read the data, and check it is “02”.
Adjustment Address B6, B7, D8 to EF
34 60 01 67 Write the data.
Specified Value1 03 to 0A
35 Check the flashing.
Specified Value2 00
36 60 02 Read the data, and check it is “01”.
Note1: Perform this adjustment in the dark room or use the flash (Note5)
adjustment box. 37 6F D8 Read the data, and check it is “00”.
Note2: Any light other than the strobe light should not light up the plate.
38 60 01 00 Write the data.
Note3: After the power is turned on, this adjustment can be done only
once. 39 Wait for 5 sec.
Note4: If the data of page: 60, address: 02 is “01”, select page: 60, address: 40 60 ED Read the data, and check it is “02”.
01, and write data: 00.
41 6F B5 FF Write the data.
Switch setting: 42 60 01 B9 Write the data.
FLASH .............................................................................. ON 43 Check the flashing.
44 60 02 Read the data, and check it is “01”.
Adjusting method:
(Note5)
Order Page Address Data Procedure
45 6F D8 Read the data, and check it is “00”.
1 Check that “1. Data Setting during
46 60 01 00 Write the data.
Camera System Adjustments” is
performed. 47 Wait for 5 sec.
2 00 01 01 Set the data. 48 60 ED Read the data, and check it is “02”.
3 60 2C 01 Set the data. 49 60 01 E7 Write the data.
4 60 90 00 Set the data. 50 Check the flashing.
5 60 91 00 Set the data. 51 60 02 Read the data, and check it is “01”.
(Note5)
6 60 92 FF Set the data.
52 6F D8 Read the data, and check it is “00”.
7 60 93 FF Set the data.
53 6F EA Read the data, and check it
8 60 6C 01 Set the data.
satisfies the specified value1.
9 60 01 79 Write the data.
54 6F EC Read the data, and check it
10 Wait until the movement of the satisfies the specified value1.
lens stops.
55 6F EE Read the data, and check it
11 60 07 Read the data, and check it is “01”. satisfies the specified value1.
12 60 01 67 Write the data. 56 6F B5 Read the data, and check it
13 Check the flashing. satisfies the specified value2.
14 60 02 Read the data, and check it is “01”.
(Note5) Note5: The adjustment data will be automatically input to page: 6F,
address: B6, B7, D8 to EF.
15 6F D8 Read the data, and check it is “00”.
16 6F E8 Read the data, and check it Processing after Completing Adjustments:
satisfies the specified value1. Order Page Address Data Procedure
17 60 01 00 Write the data. 1 60 01 00 Write the data.
18 Wait for 5 sec. 2 60 2C 00 Set the data.
19 60 ED Read the data, and check it is “02”. 3 60 6C 00 Set the data.
20 60 01 67 Write the data. 4 60 90 00 Set the data.
21 Check the flashing. 5 60 91 00 Set the data.
22 60 02 Read the data, and check it is “01”. 6 60 92 00 Set the data.
(Note5)
7 60 93 00 Set the data.
23 6F D8 Read the data, and check it is “00”.
8 If finish the camera system
24 60 01 00 Write the data. adjustments, release the data
25 Waite for 5 sec. setting.
26 60 ED Read the data, and check it is “02”. (See “1. Data Setting during
Camera System Adjustments”.)
27 60 01 67 Write the data.

6-27
MVC-CD500

17. AF Laser Output Adjustment


Adjust the AF laser outpute power.
Mode STILL(P AUTO) (P)
Subject Background paper (J-250-130-A).
(50cm from the front of the lens)
Measurement Point Data of page 6F, address: 13
Measuring Instrument
Adjustment Page 6F
Adjustment Address 10 to 16
Specified Value 00

Note1: Perform this adjustment in the dark room or use the flash
adjustment box.
Note2: Any light other than the strobe light should not light up the plate.

Adjusting method: Processing after Completing Adjustments:


Order Page Address Data Procedure Order Page Address Data Procedure
1 Check that “1. Data Setting during 1 7B 62 06 Check the data. (Note4)
Camera System Adjustments” is 2 7B 83 50 Check the data. (Note4)
performed.
3 60 01 00 Write the data.
2 00 01 01 Set the data.
4 If finish the camera system
3 6F 15 90 Set the data. adjustments, release the data
4 7B 62 06 Set the data. setting.
5 7B 83 50 Set the data. (See “1. Data Setting during
Camera System Adjustments”.)
6 60 01 AF Write the data.
7 Check that the AF Laser is lit. Note4: Operation to release the data setting.
8 60 02 Read the data, and check it is “01”.
(Note3)
9 6F 13 Read the data. and check it
satisfies the specified value1.

Note3: The adjustment data will be automatically input to page: 6F,


address: 10 to 16.

6-28
MVC-CD500

18. AF Laser Axis Check


Check the AF laser optical axix.
Mode STILL(P AUTO) (P)
Subject Background paper (J-2501-130-A).
(1m from the front of the lens)
Measurement Point LCD screen or monitor TV (under scan)
Measuring Instrument
Specified Value All hologram patterns are within the
inspection frame.

Note1: Perform this adjustment in the dark room.

Switch setting:
FOCUS ......................................................................... AUTO
Preparations:
1) Take a copy of the AF Laser axis frame with a clear sheet.
(Reduce or enlarge the frame in same size as the effective picture
frame of the LCD screen or the monitor TV.)

Adjusting method:
Order Page Address Data Procedure Fig. 6-1-14.
1 Check that “1. Data Setting during
Camera System Adjustments” is
performed.
2 00 01 01 Set the data.
3 5F 3D 50 Set the data. Processing after Completing Adjustments:
4 60 30 06 Set the data. Order Page Address Data Procedure
5 60 2C 01 Set the data. 1 5F 3D 5A Check the data. (Note2)
6 60 90 00 Set the data. 2 60 22 00 Set the data.
7 60 91 00 Set the data. 3 60 23 00 Set the data.
8 60 92 00 Set the data. 4 If finish the camera system
9 60 93 50 Set the data. adjustments, release the data
10 60 01 79 Set the data. setting.
(See “1. Data Setting during
11 Wait until the movement of the
Camera System Adjustments”.)
lens stops.
12 60 07 Read the data, and check it is “01”. Note2: Operation to release the data setting.
13 60 01 00 Write the data.
14 60 22 05 Set the data.
15 60 23 0A Set the data.
16 Check that all hologram patterns
are within the inspection frame.
(Fig. 6-1-14.)
17 60 90 00 Set the data.
18 60 91 00 Set the data.
19 60 92 00 Set the data.
20 60 93 50 Set the data.
21 60 01 79 Write the data.
22 Wait until the movement of the
lens stops.
23 60 07 Read the data, and check it is “01”.
24 60 14 8A Set the data.
25 60 01 00 Write the data.
26 5F 3D FF Set the data.
27 Check that all hologram patterns
are not unfocused.

6-29
MVC-CD500

COVER

1-5. LCD SYSTEM ADJUSTMENTS 1. LCD Type Check


By the following method, the type of LCD can be discriminated.
Note1: The back light (fluorescent tube) is driven by a high voltage AC Mode PLAY ( )
power supply. Therefore, do not touch the back light holder to
avoid electrical shock. Signal Arbitrary
Note2: When replacing the LCD unit, be careful to prevent damages Measuring Instrument Oscilloscope (DC range)
caused by static electricity.
Checking method:
Order Page Address Data Procedure
1 40 10 5D Set the data.
2 40 11 01 Set the data.
3 Check HSY signal.
“H”: LCD type S
“H sync pulse”: LCD type C
4 40 11 02 Set the data.
5 Check HSY signal.
“H”: LCD type C
“H sync pulse”: LCD type S
6 40 11 00 Set the data.
7 40 10 00 Set the data.

6-30
MVC-CD500

2. LCD Initial Data Input (1) 3. LCD Initial Data Input (2)
Mode PLAY ( ) Mode PLAY ( )
Signal Arbitrary Signal Arbitrary
Adjustment Page 4F Adjustment Page 5F
Adjustment Address 80 to 8B, 92 to 96, A3, A4 Adjustment Address 3A to 3F

Note: Refer to “1. LCD type check” for the discrimination of the LCD Adjusting method:
type. 1) Select page: 00, address: 01, and set data: 01.
2) Select page: 5F, and write the data in the following table.
Adjusting method: 3) Select page: 00, address: 01, and set data: 00.
1) Select page: 00, address: 01, and set data: 01.
2) Select page: 4F, and write the data in the following table. Address Data Remark
3) Select page: 00, address: 01, and set data: 00. 3A 58 Fixed data
3B FF Fixed data
Data
Address Remark 3C 00 Fixed data
LCD TYPE S LCD TYPE C
3D 5A Fixed data
80 60 60 Back light adj.
3E 01 Fixed data
81 A8 A8 Back light adj.
3F 00 Fixed data
82 68 36 VCO adj.
83 7B 45 VCO adj.
84 80 8F V COM adj.
85 60 60 D range adj.
86 08 08 Fixed data
87 A0 7F V COM level adj.
88 9A 7C White balance adj.
89 54 6F White balance adj.
8A 4C 40 Contrast adj.
8B 00 00 Fixed data
92 30 30 Fixed data
93 11 10 Fixed data
94 9F 9F Fixed data
95 1F 1F Fixed data
96 04 01 Fixed data
A3 23 23 Fixed data
A4 3E 3E Fixed data

6-31
MVC-CD500

4. Back Light Adjustment (PK-068 board) 5. VCO Adjustment (PK-068 board)


Set the back light control voltage. Set the VCO free-run frequency. If deviated, the LCD screen will
Mode PLAY ( ) be blurred.
Signal Arbitrary Mode PLAY ( )
Measuring Instrument Digital voltmeter Signal Arbitrary
Adjustment Page 4F Measuring Instrument Frequency counter
Adjustment Address 80 (Bright normal) Adjustment Page 4F
81 (Bright) Adjustment Address 82 (NTSC)
Specified Value Bright normal: A = 4.00 ± 0.05 Vdc 83 (PAL)
Bright: A = 5.40 ± 0.05 Vdc Specified Value 1 f = 15734 ± 100Hz
Specified Value 2 f = 15625 ± 100Hz
Adjusting method: Setup setting:
Order Page Address Data Procedure VIDEO OUT ................................................................. NTSC
1 00 01 01 Set the data. (This adjustment must be performed in NTSC mode, so don’t
set the setup setting to “PAL”.)
2 40 F1 30 Set the data.
3 4F 80 Change the data and set the DC Adjusting method:
voltage (A) to the specified value
Order Page Address Data Procedure
of the bright normal mode.
1 00 01 01 Set the data.
4 4F 80 Write the data.
2 40 F1 13 Set the data.
5 40 F1 20 Set the data.
3 4F 02 03 Write the data.
6 4F 81 Change the data and set the DC
voltage (A) to the specified value 4 4F 82 Change the data and set the VCO
of the bright mode. frequency (f) to the specified
value 1.
7 4F 81 Write the data.
5 4F 82 Write the data.
8 40 F1 00 Set the data.
6 40 1D 82 Set the data.
9 00 01 00 Set the data.
7 4F 83 Change the data and set the VCO
frequency (f) to the specified
value 2.
8 4F 83 Write the data.
9 4F 02 00 Write the data.
10 40 1D 80 Set the data.
11 40 F1 00 Set the data.
12 00 01 00 Set the data.

6-32
MVC-CD500

6. D Range Adjustment (PK-068 board) 7. Contrast Adjustment (PK-068 board)


Set the D range of the LCD driver to the specified value. If deviated, Set the level of the VIDEO signal for driving the LCD to the specified
the LCD screen will become blackish or saturated (whitish). value. If deviated, the screen image will be blackish or saturated
Mode PLAY ( ) (whitish).
Signal Arbitrary Mode PLAY ( )
Measuring Instrument Oscilloscope Signal Arbitrary
Adjustment Page 4F Measuring Instrument Oscilloscope
Adjustment Address 85 Adjustment Page 4F
Specified Value LCD TYPE S: A = 3.33 ± 0.05V Adjustment Address 8A
LCD TYPE C: A = 3.40 ± 0.05V Specified Value LCD TYPE S: A = 3.04 ± 0.07V
LCD TYPE C: A = 2.77 ± 0.07V
Note: Refer to “1. LCD type check” for the discrimination of the LCD
type. Note: Refer to “1. LCD type check” for the discrimination of the LCD
type.
Adjusting method:
Order Page Address Data Procedure Adjusting method:
1 00 01 01 Set the data. Order Page Address Data Procedure
2 40 F1 03 Set the data. 1 00 01 01 Set the data.
3 4F 02 03 Write the data. 2 40 F1 03 Set the data.
4 4F 85 Change the data and set the 3 4F 02 03 Write the data.
voltage (A) between the reversed 4 4F 8A Change the data and set the
waveform pedestal and non- voltage (A) between the pedestal
reversed waveform pedestal to the and 10 steps peak to the specified
specified value. value.
5 4F 85 Write the data. 5 4F 8A Write the data.
6 4F 02 00 Write the data. 6 4F 02 00 Write the data.
7 40 F1 00 Set the data. 7 40 F1 00 Set the data.
8 00 01 00 Set the data. 8 00 01 00 Set the data.

Pedestal
10 steps peak

A A

Pedestal
Pedestal
2H
2H
Fig. 6-1-17.
Fig. 6-1-16.

6-33
MVC-CD500

8. V COM Level Adjustment (PK-068 board) 9. V COM Adjustment (PK-068 board)


Set the common electrode drive signal level of LCD to the specified Set the DC bias of the common electrode drive signal of LCD to the
value. specified value.
Mode PLAY ( ) If deviated, the LCD display will move, producing flicker and
conspicuous vertical lines.
Signal Arbitrary
Mode PLAY ( )
Measuring Instrument Oscilloscope
Signal Arbitrary
Adjustment Page 4F
Measuring Instrument Check on LCD display
Adjustment Address 87
Adjustment Page 4F
Specified Value LCD TYPE S: A = 6.40 ± 0.05V
LCD TYPE C: A = 5.42 ± 0.05V Adjustment Address 84
Specified Value The brightness difference between the
Note: Refer to “1. LCD type check” for the discrimination of the LCD section A and section B is minimum.
type.
Note: Perform “D Range Adjustment” and “Contrast Adjustment” before
Adjusting method: this adjustment.
Order Page Address Data Procedure
Adjusting method:
1 00 01 01 Set the data.
Order Page Address Data Procedure
2 40 F1 03 Set the data.
1 00 01 01 Set the data.
3 4F 02 03 Write the data.
2 40 F1 82 Set the data.
4 4F 87 Change the data and set the
PANEL COM signal level (A) to 3 4F 02 03 Write the data.
the specified value. 4 4F 84 Change the data so that the
5 4F 87 Write the data. brightness of the section A and
that of the section B is equal.
6 4F 02 00 Write the data.
5 4F 84 Write the data.
7 40 F1 00 Set the data.
6 4F 02 00 Write the data.
8 00 01 00 Set the data.
7 40 F1 00 Set the data.
8 00 01 00 Set the data.

B A

A B

A
B A

A B

Fig. 6-1-19.

2H

Fig. 6-1-18.

6-34
MVC-CD500

10. White Balance Adjustment (PK-068 board)


Correct the white balance.
If deviated, the LCD screen color cannot be reproduced.
Mode PLAY ( )
Signal Arbitrary
Measuring Instrument Check on LCD display
Adjustment Page 4F
Adjustment Address 88, 89
Specified Value The LCD screen should not be colored.

Note: Check the white balance only when replacing the following parts. If
necessary, adjust them.
1. LCD panel
2. Light induction plate
3. IC301

Adjusting method:
Order Page Address Data Procedure
1 00 01 01 Set the data.
2 40 F1 02 Set the data.
3 4F 02 03 Write the data.
4 4F 88 Set the following data, and press
PAUSE button.
9A (LCD TYPE S)
7C (LCD TYPE C)
5 4F 89 Set the following data, and press
PAUSE button.
54 (LCD TYPE S)
6F (LCD TYPE C)
6 4F 89 Check that the LCD screen is not
colored. If not colored, proceed to
step 12.
7 4F 88 Change the data so that the LCD
screen is not colored.
8 4F 88 Write the data.
9 4F 89 Change the data so that the LCD
screen is not colored.
10 4F 89 Write the data.
11 4F 89 If the LCD screen is colored,
repeat steps 7 to 11.
12 4F 02 00 Write the data.
13 40 F1 00 Set the data.
14 00 01 00 Set the data.

6-35
MVC-CD500

COVER

1-6. SYSTEM CONTROL SYSTEM ADJUSTMENT Adjusting method:


Order Page Address Data Procedure
1. Battery End Adjustment (SY-086 board) 1 00 01 01 Set the data.
Check the battery end voltage.
2 Insert a disc.
Mode STILL(P AUTO) (P)
3 Decrease the output voltage of the
Subject Arbitrary regulated power supply so that the
Measuring Instrument Data of page: 20, address: 9B digital voltmeter display is 5.50 ±
Adjustment Page 2F 0.01Vdc.
Adjustment Address 4A to 4E 4 20 9B Read the data, and this data is
named Dref.
Switch setting: 5 2F 4A Dref Set the data and press PAUSE
FOCUS .................................................................. MANUAL button.
6 Calculate D4B, D4C, D4D and D4E
Connection: using following equations.
1) Connect the regulated power supply and the digital voltmeter (Hexadecimal calculation)
to the battery terminal as shown in Fig. 6-1-20. D4B = Dref + 05
D4C = Dref + 17
Preparations: D4D = Dref + 2C
1) Adjust the output voltage of the regulated power supply so that D4E = Dref + 37
the digital voltmeter display is 6.1 ± 0.1Vdc.
7 2F 4B D4B Set the data and press PAUSE
button.
8 2F 4C D4C Set the data and press PAUSE
button.
9 2F 4D D4D Set the data and press PAUSE
button.
10 2F 4E D4E Set the data and press PAUSE
button.
11 00 01 00 Set the data.

Digital voltmeter

Connecting point

Regulated power supply

Use thick cables.


Shorten as much as possible.
(Bellow 20cm)

Fig. 6-1-20.

6-36
MVC-CD500

2. Serial No. Input


Write the serial No. in the EEPROM (nonvolatile memory). Convert
the serial No. on the name plate from decimal to ASCII code, and
write in the EEPROM.
Page 5F
Address 46 to 4B

Input method:
1) Select page: 00, address: 01, and set data: 01.
2) Read the 6-digit serial No. on the name plate, and convert each
digit to ASCII code, and obtain D46, D47, D48, D49, D4A, and
D4B. (See below.)
6-digit serial No.

Convert to ASCII code. (Refer to Table. 6-1-8.)

D 46 (Data of address: 46)


D 47 (Data of address: 47)
D 48 (Data of address: 48)
D 49 (Data of address: 49)
D 4A (Data of address: 4A)
D 4B (Data of address: 4B)

Example: If the serial No. is 123456.


D46 = 31
D47 = 32
D48 = 33
D49 = 34
D4A = 35
D4B = 36

3) Write D46, D47, D48, D49, D4A, and D4B to each address of page:
5F.
Note3: When writing a data using the adjustment remote commander,
set the data and then press the PAUSE button to write the
data.
4) Select page: 00, address: 01, and set data: 00.

Digit 0 1 2 3 4 5 6 7 8 9
ASCII Code 30 31 32 33 34 35 36 37 38 39
Table 6-1-8.

6-37
MVC-CD500

COVER

6-2. SERVICE MODE 2. Operation

2-1. APPLICATION FOR ADJUSTMENT (SEUS) • Page change


To change the page, click [Page] on the SEUS screen and enter
The application for adjustment (SEUS) is used for changing the
the page to be changed. The page is displayed in hexadecimal
calculation coefficient in signal processing, EVR data, etc. The SEUS
notation.
performs bi-directional communication between the personal
computer (PC) and the unit using the USB signal. The resultant
• Address change
data of this bi-directional communication is written in the non-
To change the address, click [Address] on the SEUS screen and
volatile memory.
enter the address to be changed. Or click [B] to increase the
address, click [b] to decrease the address. The address is displayed
2-1-1. Using Method of SEUS
in hexadecimal notation.
1. Connection
• Data change
1) Connect the HASP key to the USB port of the PC.
To change the data, click [Set] on the SEUS screen and enter the
2) Connect the camera to another USB port of the PC.
data. Or click [v] to increase the data, click [V] to decrease the
3) Confirm that the camera starts in the USB mode.
data. The data is displayed in hexadecimal notation.
4) Start the SEUS on the PC.
This operation does not write the data to the nonvolatile memory.
5) Click [Connect] on the SEUS screen. If the connection is
If you want to write the changed data, click [Store] to write it.
normal, the SEUS screen will be as shown in Fig. 6-2-1,
indicating the “connected” state.
Note: The SEUS will go in “disconnect” state, if the camera is turned • Data writing
off (for instance, by resetting the unit). In such a case, click To write the data to the nonvolatile memory, click [Write] on the
[Connect] on the SEUS screen to restore the “connected” state. SEUS screen and enter the data to be written.

• Data reading
The data displayed on the SEUS screen are the data values at the
time when the pages and addresses were set, and they are not
updated automatically. To check the data change, click [Read] on
the SEUS screen and update the displayed data.

2-1-2. Precaution on Use of SEUS


Mishandling of the SEUS may erase the correct adjustment data at
times. To prevent this, it is recommended that all adjustment data
be saved before beginning adjustments.

1) Click [Page Edit] on the SEUS screen.


2) Click [Page], and enter the page number to be saved.
3) Click [Read] to read the data to be saved from the camera.
4) Click [File] and save the data.

Fig. 6-2-1.

6-38
MVC-CD500

COVER

2-2. SERVICE MODE 2. Bit value discrimination


Bit values must be discriminated using the hexadecimal data for
1. Setting the Test Mode following items. Use the table below to discriminate if the bit value
Page 2F Address 21 is “1” or “0”.

Data Function Hexadecimal data


00 Normal
05 Forced MOVIE mode power ON
07 Forced STILL mode power ON
08 Forced PLAY mode power ON

• Before setting the data, select page: 00, address: 01, and set data:
bit3 to bit0 discrimination
01.
• For page 2F, the data set is recorded in the non-volatile memory bit7 to bit4 discrimination
by clicking [Write] button. In this case, take note that the test
mode will not be exited even when the main power is turned off.
• After completing adjustments/repairs, be sure to return the data Display on the Bit values
of this address to “00”, and press [Write] button. adjustment bit3 bit2 bit1 bit0
Select page: 00, address: 01, and set data: 00. remote or or or or
commander bit7 bit6 bit5 bit4
0 0 0 0 0
1 0 0 0 1
2 0 0 1 0
3 0 0 1 1
4 0 1 0 0
5 0 1 0 1
6 0 1 1 0
7 0 1 1 1
A 8 1 0 0 0
9 1 0 0 1
A (A) 1 0 1 0
B (b) 1 0 1 1
C (c) 1 1 0 0
D (d) 1 1 0 1
B E (E) 1 1 1 0
F (F) 1 1 1 1

Examples: If the hexadecimal data is “8E”, the bit values for bit7 to bit4
are shown in the A column, and the bit values for bit3 to bit0
are shown in the B column.

6-39
MVC-CD500

3. Switch check (1)


Page 20 Address 20

Bit Function When bit value=1 When bit value=0


2 LENS CAP switch (LS-064 board S801) OFF (Removed) ON (Attached)
5 LID OPEN switch (PK-068 board S307,308) Close Open

Using method:
1) Select page: 20, address: 20.
2) Read the data. By discriminating the bit value of the data, the state of the switches can be discriminated.

4. Switch check (2)


Page 20 Address 80

Bit Function When bit value=1 When bit value=0


0 POWER switch (XPWER ON) (Control switch block) OFF ON
1 Mode dial (PLAY) (Control switch block) OFF ON
3 Shutter button (XSHTR ON SW) (Control switch block) OFF ON
4 Shutter button (XAELOCK SW) (Control switch block) OFF ON
Using method:
1) Select page: 20, address: 80.
2) Read the data. By discriminating the bit value of the data, the state of the switches can be discriminated.

5. Switch check (3)


Page 20 Address 90 to 96
Using method:
1) Select page: 20, address: 90 to 96.
2) Read the data. By discriminating the data, the pressed key can be discriminated.

Data
Address
00 to 0D 0E to 27 28 to 4A 4B to 77 78 to AB E5 to FF
90 Mode dial Mode dial Mode dial Mode dial Mode dial
(MODE DIAL) STILL STILL STILL STILL Mode dial STILL
(IC402 tf) (AE-S) (AE-A) (MANUAL) (SCENE) MOVIE (P AUT0)
Control button
Control button
91 DOWN UP MENU
(KEY AD0) (SELF TIMER) (FLASH) (S002) No key input
(IC402 tg ) (S001) (S001) (FS-068 board)
(FS-068 board)
(FS-068 board)
Control button
92 Control button LEFT Control button
(KEY AD1) RIGHT (EDIT SEARCH) SET No key input
(IC402 th ) (MACRO)(S001) (S001) (S001)
(FS-068 board) (FS-068 board) (FS-068 board)
DISPLAY/LCD IMAGE SIZE/
93 BACK LIGHT DELETE EV FOCUS AE LOCK
(KEY AD2) ON/OFF (S301) (S302) (S305) (S306) (S303) No key input
(IC402 tj ) (PK-068 board) (PK-068 board) (PK-068 board) (PK-068 board) (PK-068 board)
94
(KEY AD3) ZOOM WIDE ZOOM TELE Jog dial No key input
(IC402 tk ) EXECUTE
96
(MODE DIAL2) Mode dial No key input
(IC402 y; ) STILL (AUTO)

6-40
MVC-CD500

6. Switch check (3)


Page 20 Address 81
Using method:
1) Select page: 20, address: 81.
2) By discriminating the bit value of the data, the state of the switches can be discriminated.

Jog dial Upper digit of the data


When rotated upward. ··· 1 t 5 t D t 9 t 1 t ···
When rotated downward. ··· 1 t 9 t D t 5 t 1 t ···

7. LED check
Page 20 Address 04

Using method:
1) Select page: 20, address: 04, set data: 02.
2) Check that all LED (FLASH, CHARGE, ACCESS, SELF TIMER, POWER) are lit.
3) Select page: 20, address: 04, set data: 00
8. Record of Use check
Page 4F Address AD to AF

Address Function Remarks


AC Recording counter 1000000-digit and 1000000-digit
AD (Hexadecimal) 1000000-digit and 10000-digit
AE 1000-digit and 100-digit
AF 10-digit and 1-digit
Using method:
1) The recording counter data is displayed at page: 4F, addresses: AC to AF. These data are
named DAC, DAD, DAE and DAF respectively.
2) Calculate the recording counter (N) using following equation. (Hexadecimal calculation)
N = DAF + DAE × 100 + DAD × 10000 + DAC × 1000000
9. Self Diagnostics Log check
Page 20 Address B0 to B8

Address Initial value Self-diagnosis code


B0 00 “Repaired by” code (Occurred 1st time) *1
B1 00 “Block function” code (Occurred 1st time)
B2 00 “Detailed” code (Occurred 1st time)
B3 00 “Repaired by” code (Occurred 2nd time) *1
B4 00 “Block function” code (Occurred 2nd time)
B5 00 “Detailed” code (Occurred 2nd time)
B6 00 “Repaired by” code (Occurred 3rd time) *1
B7 00 “Block function” code (Occurred 3rd time)
B8 00 “Detailed” code (Occurred 3rd time)
*1: “C” t “01”, “E” t “03”
Using method:
1) The self diagnostics log is displayed at page: 20, addresses: B0 to B8.
Note: These data will be erased when the lithium battery (FP-651 flexible) is removed.

Adjustments of DDX-G3000 COMPLETE


ASSEMBLY are not shown.
Pages from 6-45 to 6-75 are not shown.

6-41
MVC-CD500
〈FOR CAMERA COLOR REPRODUCTION ADJUSTMENT〉

Take a copy of CAMERA COLOR


REPRODUCTION FRAME with
a clear sheet for use.

〈AF ILLUMINATION FRAME〉



6-42E
Reverse 987621653.pdf

Revision History

S.M. Rev.
Ver. Date History Contents
issued
1.0 2003.04 Official Release — —
1.1 2003.05 Correction-1 Correction of adjustment contents Yes
S.M. correction: Page 6-3
1.2 2003.07 Correction-2 Correction of adjustment contents Yes

Potrebbero piacerti anche