Sei sulla pagina 1di 161

BILL QUANTITIES

FOR

MIXED USE BUILDING


FOR

NATIONAL OIL ETHIOPIA


at
ADDIS ABABA

PRICED
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

SUMMARY OF BILL OF QUANTITIES

FOR
MIXED USE BUILDING

A-SUB STRUCTURE

1 Excavation and earth work......................................................Birr 1,735,616.29


2 Concrete work.......................................................................... Birr 56,666,402.30

TOTAL A........... Birr 58,402,018.59

B. SUPER STRUCTURE

1 Concrete work........................................................................... Birr 70,310,653.07


2 Walling...................................................................................... Birr 2,773,938.71
3 Roofing..................................................................................... Birr 0.00
4 Carpentry and Joinery...............................................................Birr 0.00
5 Metal work............................................................................... Birr 52,000,000.00
6 Plastering and Pointing.............................................................. Birr 0.00
7 Finishing................................................................................... Birr 0.00
9 Painting.................................................................................... Birr 0.00
10 Sanitary Installation..................................................................Birr 13,396,295.00
11 Electrical Installation................................................................Birr 70,291,321.31
11 Mechanical Installation.............................................................. Birr 73,411,966.00

TOTAL B........... Birr 282,184,174.09

TOTAL A + B........... Birr 340,586,192.68

10% Contigency........... Birr 34,058,619.27

Total........... Birr 374,644,811.94

Page 2 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

Item
Description Unit QTY Rate Amount
no

Page 3 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

A-SUB STRUCTURE

1. EXCAVATION & EARTH WORK

1.01 Clear and remove top soil to an average depth of


200mm. M2 1482.43 38.48 57,043.71

1.02 Bulk excavation in ordinary soil to reduce level to the


specified depth on the drawing. M3 2523.63 75.03 189,347.68

1.06 Fill around foundation and building in non expansive


material from the site well rolled and compacted in
layers not exceeding 200 mm thick. M3 12222.00 100.00 1,222,200.00

1.08 Load and cart away surplus excavated material to an


appropriate tip. 2523.63 105.81 267,024.89
M3

TOTAL CARRIED TO SUMMARY ................................................... 1,735,616.29

Page 4 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

2. CONCRETE WORK
2.01 100 mm lean concrete quality C-5, with minimum
cement content of 150 kg /m3, of concrete;
a) Under Mat Slab M2 1539.93 449.54 692,257.88

2.02 Reinforced concrete quality C-30,400 kg of cement/m3


filled in to form work and vibrated around rod
reinforcement.(Formwork and reinforcement measured
separately)
a) In 1400mm thick Mat Slab M3 2447.77 4,604.69 11,271,199.94
b) In Basment Column M3 183.15 4,604.69 843,365.55
c) In 350mm thick suspended flat slab ( Basment & Gro M2 3783.52 1,611.64 6,097,673.12
e) In Lift shaft Shear Wall M3 123.02 4,604.69 566,486.46
e) In Shear Wall central core shearwall M3 164.37 4,604.69 756,853.91
e) In 350mm thick RC retaining Wall M3 1048.08 4,604.69 4,826,063.21
f) In Staircase & landing M3 45.70 4,604.69 210,439.63
g) In 350mm thick Ramp M2 285.30 1,611.64 459,800.89

2.03
Provide, cut and fix in position sawn structural wood
or steel formwork which ever is appropriate;

a) To solid mat foundation M2 61.53 684.72 42,129.45


b) To Basment Column M2 780.47 684.72 534,404.79
c) To First Basment floor slab M2 1185.15 684.72 811,494.98
d) To Second basement Floor slab M2 1185.15 684.72 811,494.98
e) To Ground floor slab M 2
1362.26 684.72 932,769.95
f) To lift Shaft Shear wall M2 1732.71 684.72 1,186,419.88
g) To ShearWall M2 211.30 684.72 144,678.87
h) To RC retaining Wall M2 2899.35 684.72 1,985,241.22
i) To Staircase & landing M2 209.39 684.72 143,371.81
j) To Ramp M2 331.70 684.72 227,118.20

2.05 Mild steel reinforcement according to structural


drawings. Price includes cutting, bending, placing in
position,tying wire and concrete spacers.

a) Dia 8 mm deformed bar Kg 7733.37 48.52 375,223.27


b) Dia 10mm deformed bar Kg 741.08 48.52 35,957.14
c) Dia 12 mm deformed bar Kg 43945.61 48.52 2,132,240.92
d) Dia 14 mm deformed bar Kg 62370.17 48.52 3,026,200.51
e) Dia 16 mm deformed bar Kg 130991.55 48.52 6,355,709.92
f) Dia 20 mm deformed bar Kg 73187.46 48.52 3,551,055.62
g) Dia 24 mm deformed bar Kg 167865.47 51.51 8,646,750.20

TOTAL CARRIED TO SUMMARY ................................................... 56,666,402.30

Page 5 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

B-SUPER STRUCTURE
1. CONCRETE WORK
1.01 Reinforced concrete quality C-30,400 kg of cement/m3
filled in to form work and vibrated around rod
reinforcement.(Formwork and reinforcement measured
separately)
a) In Elevation columns M3 857.15 4,300.00 3,685,731.24
e) In 150mm thick floor Slab M2 17671.14 645.00 11,397,882.72
f) In 150mm thick Roof Slab M2 783.28 645.00 505,215.60
g) In Staircase and landing M 3
174.57 4,300.00 750,632.73
h) In lift Shaft Shear Wall M3 1382.04 4,300.00 5,942,755.24
h) In Shear Wall M3 397.60 4,300.00 1,709,666.37

1.03
Provide, cut and fix in position sawn structural wood
or steel formwork which ever is appropriate;

a) To Elevation columns M2 3756.22 320.00 1,201,991.68


d) To Floor slab M2 18058.27 320.00 5,778,646.27
e) To Roof slab M2 783.28 320.00 250,649.60
f) To Staircase and landing M2 675.12 320.00 216,037.92
g) To lift shaft Shear Wall M2 8537.10 400.00 3,414,840.30
h) To Shear Wall M2 2485.48 400.00 994,191.84

1.04 Mild steel reinforcement according to structural


drawing. Price includes cutting, bending, placing in
position , tying wire, concrete spacers and
reinforcement bar chairs.
a) Dia 6 mm plain bar Kg 40.00 0.00
b) Dia 8 mm deformed bar Kg 14733.64 38.00 559,878.40
c) Dia 10 mm deformed bar Kg 1097.46 38.00 41,703.40
d) Dia 12 mm deformed bar Kg 94605.50 36.00 3,405,798.08
e) Dia 14 mm deformed bar Kg 70159.28 36.00 2,525,734.12
f) Dia 16 mm deformed bar Kg 296550.03 36.00 10,675,801.24
g) Dia 20 mm deformed bar Kg 248866.06 36.00 8,959,178.27
h) Dia 24 mm deformed bar Kg 230397.72 36.00 8,294,318.05

Page 6 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

TOTAL CARRIED TO SUMMARY ................................................... 70,310,653.07

2. BLOCK WORK
2.01 Class B, 200mm thick HCB wall with the designed
compressive strength , bedded in cement mortar
(1:3).Price shall include mortar bed. M2 4076.82 579.90 2,364,147.92
2.03 Ditto as Item 2.01 but 150mm thick M2 891.00 434.93 387,522.63
2.04 Ditto as Item 2.01 but 100mm thick M2 76.80 289.95 22,268.16

TOTAL CARRIED TO SUMMARY ................................................... 2,773,938.71

3. ROOFING

3.01 Brush and blow out dirt, dust, latency, scrapings and
all other loose material until the reinforced concrete
slab is fully cleared. Cast average depth of 60mm thick
light weight concrete to provide slope as indicated on
drawing for concrete roofing(including steaped roof).

M2 906.24 0.00

3.02 30mm thick smooth finished cement sand screed laid


on top of light weight concrete and gutter in mortar
mix (1:3) with proper slope towards down pipe.
M2 906.24 0.00

3.03 EPDM synthetic rubber membrane (1.2mm) roof water


proofing, Hertalan or equivalent, bonded using
appropriate adhesive hertlan Ks143, Ks37, Ks87; as
appropriate, or equivalent.

M2 906.24 0.00

3.0 TOTAL CARRIED TO SUMMARY ................................................... 0.00

4. CARPENTRY AND JOINERY


4.01 Supply and fix 40mm thick high quality hollow core
flush wooden door with hard wood frame and both
sides covered with best quality 4mm thick ply wood,
wall nut or OAK veneered type including best quality
cylinder lock ,hinges and door stopper. Price includes
three coats of varnish paint.

a) Type D1 = size:1300x2200mm Pcs 15.00 0.00


b) Type D2 = size:900x2200mm Pcs 3.00 0.00
c) Type D3= size:950x2200mm Pcs 5.00 0.00
d) Type D3'= size:1600x2200mm Pcs 24.00 0.00
e) Type D4 = size:850x2200mm Pcs 5.00 0.00
f) Type D5 = size:800x2200mm Pcs 5.00 0.00
g) Type D6 = size:900x2200mm Pcs 57.00 0.00
h) Type D7 = size:800x2200mm Pcs 2.00 0.00

4.02 PARTITION WITH DOORS

Page 7 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

13mm thick water, scratch, impact and abrassion


resistant high density solid compact laminated panel
with melamine finish on both sides; framed with black
anodized alumunium, with matching balck nylon
(polyamide) accessories. Panels fixed on floor on
adjustable leg anchored to the floor, to wall by
aluminum U channel or bracket, with a heavy duty
aluminum channel on top of front panel. Doors made
of phenolic resin boards, equiped with 2 hinges, door
knob, indicator rosette and coat hook.

Partition walls (all ceiling height) m2 765.00 0.00


4.2.1 Supply and install Frameless Operable Glass
partition(s) and suspension system Section includes,
but is not limited to, furnishing, delivering and
erecting the following work: Single-glazed with
aluminum, top and bottom channels, LCD privacy
glazing, Doors and door hardware and Accessories
required for a complete working installation.
M2 3183.48
Dittp 4.2.1 but framed glass M2 1142.40
4.2.2 Acoustically sound insulated wall M2 2096.64
4.2.2 Wooden wall M 2
177.66

4.2.2 Doors type D5 (540x2200mm) pcs 0.00

TOTAL CARRIED TO SUMMARY ................................................... 0.00

Page 8 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

5. ALUMINUM WORK
Supply and fix anodized aluminum profiles of the
following specifications: AA 6063, Norm EN 573-3/
EN 755-2/ EN 755 & EN 12020; tensile strength 215
N/mm2 ; thickness of anodizing layer 10-15micron.
Accessories: handles, door closer, arms, locks; Italian
GIESSE & German Dorma or equivalent. Glazing
tinted glass 5mm, with appropriate structural silcon.
Section of profile and thickness should be determined
based on structural requirement of each type of façade
items, but minimum thickness of profile shall not be
5.01 less than 1.5mm.
ALUMINUM FRAMED WINDOWS

a) Type W1 = size: 3660x800mm Pcs 4.00 0.00


a) Type W1 = size: 5500x800mm Pcs 4.00 0.00
b) Type W1' = size: 2300x1200mm Pcs 34.00 0.00
c) Type W3 '= size: 5500x2940mm Pcs 0.00

5.02 Doors
a) Type D1 = size: 700x2500mm Pcs 2.00 0.00
b) Type D1 = size: 800x2500mm Pcs 28.00 0.00
c) Type D3= size: 900x2500mm Pcs 33.00 0.00
d) Type D4= size: 1100x2200mm Pcs 1.00 0.00
e) Type D5 = size: 1200x2500mm Pcs 58.00 0.00
f) Type D6 = size: 1600x2500mm Pcs 31.00 0.00
g) Type D7= size: 2000x2500mm Pcs 1.00 0.00
g) Type D8= size: 2150x2500mm Pcs 1.00 0.00

5.03 PVC/Alumnium Door


a) Type D1 = size: 700x2200mm Pcs 76.00 0.00
b) Type D1' = size: 900x2200mm Pcs 36.00 0.00
c) Type D2= size: 1020x2200mm Pcs 2.00 0.00

5.03 Window and Doors

a) Type WD1 = size: 5800x6740mm Pcs 2.00 0.00


b) Type WD2 = size: 6100x6700mm Pcs 1.00 0.00
b) Type WD2 = size: 6600x6700mm Pcs 1.00 0.00

CURTAIN WALL
5.04 Curtain wall made of Aluminum semi-structural
frames of appropriate section to safely bear the
expected load , covered with single glass sheet glazing
6mm thick tinted with performance of noise level 35-
40db,coeffecient of thermal transmission 1.9W/m
M2 487.12 0.00

5.05 Supply and structural curtain wall made of glazed


continuous horizontal panel or glass bearing units.
The units are composed of a frame with horizontal
perimetral profiles able to mechanically restrain the
glass panel by inserting an external glass beading
profile and vertical profiles that enable the glass to
cover the profiles. The materials to be used are high
quality, anodized aluminum profile frames with 6mm
thick UV protected curved,tempered,insulated,double
glass openable window and sealant, as per the
engineers approval. Price shall include glass,
anchorage, sealant and all the necessary accessories
needed to finish the work.

Page 9 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

NB: The Structural curtain wall shall be supplied and


erected under the direct supervision of an approved
specialist organization , thoroughly experienced in work
of a similar nature and with facilities appropriate to the
quantities involved. The works contractor is not to give
rate for this items.

Provide all the necessry assisatane for the installation


of the above curtain wall to the nominated sub-
contractor. The main contractor shall be responsible to
eventually administer and comission the nominated
sub-contractor to be selected through a bid conducted
by the client all payments shall be conducted through
the main contractor.
ps 52,000,000.00

Page 10 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

GLASS BLOCK AROUND BUILDING


5.06 Supply and Fix glass blocks with around the building
for lighting with size of 550x300 mm with all nessary
accesories pcs 8.00 0.00

High quality stainless steel  glass balustrade railing


for balcony, stair
5.07 Supply and fix best quality stainless steel hand rail
with 12mm thick glass balustrad and with Supporting
Stainless steel post of Dia 50mm and 900mm high for
Staircase anchored in to concrete , Diameter 50mm
horizontal Stainless steel hand rail screwed to vertical
post.(All according to AR. detail drawing.) price
includes all necessary accessories needed to finish the
works. Ml 340.80 0.00

5.07 Ditto as item 5.07 but 900mm height Guard rail Ml 114.70 0.00

5.08 Supply and fix 80 x 30mm shaped best quality Stainless


steel wall mounted hand rail screwed to diameter
30mm and stainless steel rod balustrade screwed to
Stainless steel spacer. All according to AR. Drawing.
Ml 216.92 0.00
TOTAL CARRIED TO SUMMARY ................................................... 52,000,000.00

6.PLASTERING AND POINTING


Note that during application of plastering cost includes
preparing the concrete areas with bonding plaster
chemical .Contractor should avoid chiseling of areas.

6.01 Apply two coats of plastering in cement mortar (1:3).


Price shall include pre-cleaning and preparation of the
surface.

a) To all internal wall surface M2 1543.61 0.00


b) To exposed Column and beam M2 4224.00 0.00
c) Stair soffit M2 911.20 0.00

Page 11 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

6.02 Apply approved gypsum plaster with a minimum


thickness of 3mm over the 2nd coat plastered surface
to internal wall.Work and cost includes:- preparing the
surfaces , preparing every working materials
etc.Application shall be done after well cured the
plasterd surface and as per the instruction of engineers.

a) To all internal wall surface M2 1543.61 0.00


b) To exposed Beam, columns M2 4224.00 0.00
c) Stair Soffit M2 911.20 0.00

6.03 Apply three coats of plastering in cement mortar (1:3)


and. Price shall include pre-cleaning and preparation
of the surface

a) To all External wall surface M2 0.00


b) To all Internal wall surface M 2
2113.34 0.00
c) To exposed Column and beam M2 0.00
d) To RC slab and Stir soffit M2 1090.00 0.00
6.02 Supply and fix best quality gypsum board surface to
internal wall and apply approved gypsum plaster with
a minimum thickness of 3mm over .Work and cost
includes:- preparing the surfaces , preparing every
working materials etc.Application shall be done after
well cured the plasterd surface and as per the
instruction of engineers.

a) internal wall surface M2 210.00 0.00


b) exposed Beam, columns M2 120.00 0.00
TOTAL CARRIED TO SUMMARY ................................................... 0.00

7. FINISHING
CEMENT SCREED
7.01 48mm thick cement sand screed smoothly finished
flooring in mortar mix (1:3).
a) To epoxy floor tile M2 3723.54 0.00

7.02 40mm thick cement sand screed smoothly finished


flooring in mortar mix (1:3).
a) To receive ceramic and granite floor tile. M2 6256.00 0.00
b) To receive Porcline floor tile M2 15310.17 0.00

CERAMIC FLOOR AND SKRTING TILES


7.03 Supply and fix best quality (european standard) 8mm
thick 200mmx400mm, Non-Skid mat Ceramic stuck
down with approved type adhesive on cement sand
screed floor finish and joints grouted in approprate
color setting coat mortar. Quality, Color and pattern of
tile shall be approved by the Engineers.
M2 891.7 0.00

7.04 100mm high Ceramic skirting stuck to wall with


approved type of adhesive. Quality, Color and pattern
of tile shall be approved by the Engineers. Ml 0.00

PORCELAINED FLOOR AND SKRTING TILES


7.05 Supply and fix high quality fine porcelain stoneware,
homogeneous throughout the body with 10mm thick
600mmx600mm, PORCELAINED GRES stoneware tile
RAK GP-9UP or equivalent. Quality, Color and pattern
of tile shall be approved by the Engineers.
M2 15310.17 0.00

Page 12 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

7.06 (20x100mm) porcelained skirting stuck to wall with


cement mortar backing mix (1:2) ,price includes cement
mortar backing. Quality, Color and pattern of tile shall
be approved by the Engineers.
Ml 3091.50 0.00

GRANITE
7.07 Supply and fix best quality 20mm thick GRANITE
polish finish for lobby area bedded on and including
30mm thick cement sand (1:3) mortar and joints
grouted with appropriate color filler material.Color to
be approved by the architect.Size 600x600mm. Quality,
Color and pattern of tile shall be approved by the
Engineers. M2 3843.85 0.00

7.08 (20x100mm) high best quality granite skirting stuck to


wall with cement mortar (1:2). Price includes cement
mortar backing. Quality, Color and pattern of tile shall
be approved by the Engineers.
Ml 1275.68 0.00

PVC TILE AND SKIRTING


7.09 Supply and fix 2mm thick best quality pvc floor finish
CENIT 410-30 or equivalent with appropriate
adhesive .Quality, Color and pattern of tile shall be
approved by the Engineers. M2 0.00

Page 13 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

7.10 80mm high best quality PVC skirting to wall with


approved type of adhesive.Quality, Color and pattern
of tile shall be approved by the Engineers. Ml 0.00

GRANITE STAIR ELEMENTS


7.11 Supply and fix best quality granite tile well polished
and chamfered to staircase and landing bedded on and
including 20mm thick cement sand (1:3) mortar.
Quality, Color and pattern of tile shall be approved by
the Engineers.

a) 30 x350 mm stair threads Ml 1040.00 0.00


b) 20 x150 mm thick stair risers Ml 1040.00 0.00
c) 20 mm thick 100mm high stair way skirting Ml 717.60 0.00
d) 30mm thick to stair case landing. M2 320.00 0.00

7.12 270x30mm Marble window sill cut to appropriate size,


weathered and mounted on and including 30mm thick
cement mortar (1:3) bedding. Price includes making
water drip and edge chamfering as shown on the Ml 114.84 0.00
Architectural detail drawing.Quality, Color and
pattern of tile shall be approved by the Engineers.
7.13
20mm thick marble threshold bedded on & including
30mm thick cement mortar.Quality, Color and pattern
of tile shall be approved by the Engineers.

a) Width 400mm Ml 186.20 0.00


b) Width 200mm Ml 306.20 0.00
C) Width 150mm Ml 0.00

7.14 Supply and fix best quality 300X600X 20mm thick


composite GRANITE wall tile cladding on aluminum
framing for lift shaft.Price includes Aluminum frames
and stiffnesrs,structural silicon,angle brackets,clips and
wall runners and all necessary works.Quality, Color
and pattern of tile shall be approved by the Engineers.
M2 5143.04 0.00

7.15 High Quality Italy or equivalent glazed ceramic wall


tile bedded to walls on & including cement mortar (1:3)
backing & joints grouted in appropriate color . Type,
color, size and pattern of tile shall comply with
technical specification requirement,Architects
preference and approval. M2 548.42 0.00
7.16 ROADCOAT CETRO’ or equivalent epoxy and
polyurethane system surface application to ramps to
BSEN 1504-2 standard.Price includes shall include
broom finsh and all the necessary materials and works
needed to complte the works.
M2 916.01 0.00

7.16 ROADCOAT CETRO’ or equivalent epoxy and


polyurethane system surface application to basement
parking to BSEN 1504-2 standard. Price includes
‘CENTRO Hi Mark’ or equivalent marking of traffic
floor signs, arrows etc Quality, Color and pattern of tile
shall be approved by the Engineers.
M2 2843.54 0.00
7.17 Ditto 7.16. but rough epoxy application to ramp
basement parking M2 479.81 0.00

7.18 Supply and fix Best quality Rubber on Column guards


dimension width 100mmX100mm, Length 1200mm
and thikness 10mm PC 294.00

Page 14 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

7.19 Carpent floor finshing M2 924.90


7.20 Wood floor finshing M 2
360.70
7.21 Rubber mat floor finshing M2 44.50
7.22 Composite stainless steel for column clading M2 216.00

CEILING
7.23 Supply and fix best quality sound proof suspended
venly profile ceiling with galvanized metal support
hinged from concrete slab. All according to detail AR.
drawing & engineers approval. (for toilet ) price shall
include all the necessary materials and works needed
to finish the works.Quality, Color and pattern of tile
shall be approved by the Engineers.
M2 891.70 0.00
7.24 Perforated metal best quality Armstrong ceiling
complete with fixing accessories, hanged from
concrete slab prepared for recessed light
fittings.Quality, Color and pattern of tile shall be
approved by the Engineers. M2 15,475.76 0.00

Page 15 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

7.25 Gypaum Board M2 9,734.97 0.00


TOTAL CARRIED TO SUMMARY ................................................... 0.00

8. PAINTING
8.01 Supply and apply full bodied, semi-glossy best quality
emulsion paint

a) To all internal wall surface. M2 1,543.61 0.00


b) To all External Wall Surface M2 2113.34 0.00
c) To RC ceiling M2 1090.00 0.00
TOTAL CARRIED TO SUMMARY ................................................... 0.00

9-SANITERY INSTALLATION
9.1 SANITARY EQUIPMENT (FIXTURES)

All fixtures which differs from that specified below


issubject to the owner's approval, based on
samples,catalogues and brochures presented by the
Contractor.Unit Price shall include all the necessary
fixing brackets or hooks and all the necessary
assistance civil works such as chiseling of walls,floors,
beams and etc…

ALL FIXTURES ARE APPROVED EUROPEAN BRAND

9.1.1 Supply and fix R.A.K. or Equivalent, under counter


vanity type hand wash basins made of white glazed
vitreious china ceramic with mirror polished 2cm thick
granite topping, Front and side apron, skirting and all
fixing acceeseries as per the detail drawing. The price
includes GROHE or Equivalent Single-lever basin mixer
water faucet,
complete with mixing battery plug, chrome plated chain
holder, P-smell trap with connection pipe, fittings, all
other necessary etc. complete in all respects. Flexible
hose to be GROHE or Equivalent and should be
capable of resisting pressure of 4 bar. P-smell trap
should be GROHE or Equivalent brass chrome plated
with 50mm height of water seal and trap. Color of
Granite topping to be Mirror Polished Black

Faucet
Brand: GROHE or Equivalent
Maximum flow rate: 6 l/min

Vanity
White Vitreous china ceramic
Type: Under Counter
Brand: ROSA UNDER COUNTER

Size of Granite topping:


800x600x20 mm (Single Bowel) Set 2.00 0.00

Size of Granite topping:


1600x600x20 mm (Double Bowel) Set 58.00 0.00

9.1.2 Supply and fix R.A.K. or Equivalent, hand wash basins


made of white glazed vitreous china with GROHE or
Equivalent chrome plated cold water tap, pedestal
stand ,complete with mixing battery plug, chrome
plated chain holder, P-smell trap with connection pipe,
fittings, all other necessary etc. complete in all
respects. Flexible hose to be GROHE or Equivalent to
be Vinyl coated and should be capable of resisting
pressure of 4 bar. P-smell trap should be brass chrome

Page 16 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

plated with 50mm height of water seal and trap.


MODEL: COMPACT
Size :- 500 x 400mm No 10.00 0.00

9.1.3 Supply and fix LAUFEN or Equivalent, white glazed


vitreous china wall mounting type (European style) P/S
trap water closet with solid white plastic soft closing
seat snap catch for easily removal and lid, chrome
plated brass hinges and rubber buffers including
required fittings, accessories etc. complete in all
respects. Flexible hose to be GROHE or Equivalent and
should be capable of resisting pressure of 4 bar.

Product: Wall hung WC pan


Brand: LAUFEN
Range: HI Jet 0.00
Model: 8.2066.1.000.000.1
Including Laufen easy fit 8.9282.7
Color: white
Size: 530x367x350mm

ABLUTION SPRAY
Ablution spray with double interlock hose and fixed
bracket having a quarter turn angle valve
Brand: BOSSINI or Equivalent
Model: SHEILA B00421

CISTERN FOR WALL HUNG WATER CLOSET


MOUNTING ELEMENT FOR WALL HUNG WATER
CLOSET
Brand: GEBRIET or EQUIVALENT
Model: 110.350.00.5
Kombi fix element with UP320, front actuation
Scope of delivery:
- Water supply connection R 1/2" with integrated
angle stop valve
- Geberit AquaClean conduit pipe
- Flush bend
- Protection plug
- Protection cover for service opening, can be out to
length
- WC outlet bend, HDPE, dia. 110 mm
- WC connection set, dia. 90 mm
- 2 threaded rods M12 for ceramics fastening
- Fastening materials

ACTUATOR FOR WALL HUNG WATER CLOSET

Geberit Actuator plate


- For dual flush
Scope of delivery:
- 2 actuator rods
- 2 distance bolts
- Mounting frame
Article no.
115.770.FR.1
Color = Star White Set 114.00 0.00

9.1.4 Supply and fix R.A.K. or Equivalent, white glazed


vitreous china floor mounting type (European style) S
trap water closet with solid white plastic seat and lid,
chrome plated brass hinges and rubber buffers with
white vitreous china 3/6 dual flush coupled cistern
including required fittings, ablution wash fittings and
accessories etc. complete in all respects. Flexible
hose to be GROHE or Equivalent and should be
capable of resisting pressure of 4 bar.

Page 17 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

Brand: R.A.K.
Model: STAR SYPHONIC No 2.00 0.00

9.1.5 Supply and fix LAUFEN or Equivalent, white glazed


vitreous china (European style) flat back urinal including
infrared/ultra violet battery operated concealed auto
flush senser 15mm diameter Complete including
making connection with chrome plated brass pipe to
chrome plated spreader, 32mm domical waste with
32mm brass bottle trap and pipe to wall, wall flanges. All
required cutting and making good the walls and floors
and assistant civil work.

Brand: LAUFEN
Product: Urinal TAMARO-VS white
Range: Tamaro
Colour: white
Size: 390x365x825mm No 24.00 0.00

9.1.6 Supply and fix LAUFEN or Equivalent white vitreous


china standard urinal partition with chrome plated
brass
screws and washers fixed to walls including all
assistant
civil works to make the system complete.

Brand: LAUFEN
Product: CINTO urinal division, white, incl. fixing device
Model: 8.9960.1
Colour: white
Size: 460x90x720mm No 24.00 0.00

9.1.7 Supply and fix GEESA or Equivalent white glazed

vitreous china wall mounting type toilet paper holder


with chrome plated fastening screws and other
accessories. No 138.00 0.00

9.1.8
Supply and fix GEESA or Equivalent Chrome plated

Sanitary Bag Dispenser with chrome plated fastening


screws and other accessories to make the system
complete.
Brand: GEESA or Equivalent
Range: Standard hotel collection 0.00
Model: 122
Including Laufen easyfit 8.9282.7
Size: 134H x 85W x 26D mm No 138.00 0.00

9.1.9
Supply and fix GEESA or Equivalent Chrome plated
Litter Bin of 3 Liter capacity.
Brand: GEESA or Equivalent
Range: Standard hotel collection 0.00
Model: 625-C
Size: 245H x 170W mm No 138.00 0.00

9.1.10
Supply and fix LEEDS-C4 or Equivalent 6mm thick

facial crystal glass mirror with integrated lighting for


hand wash basins with copper back protection,
including chrome plated brass mirror clips with
chrome
plated screws and etc... for hand wash basins.
Brand: Leds-C4

Page 18 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

Reference: SW-1014-PRO-130762
- Led strip, Warm White, 35W
- Defogster: Ref. SW1014a RPR-131524 (optional)

Size :- 1140 x 800 mm (HxW) No 152.00 0.00

9.1.11 Supply and fix GEESA or Equivalent wall mounting


type

double tubular chrome plated swing pattern towel rail


with chrome plated fastening brass screws and
accessories complete in all respects.
Brand:GEESA or Equivalent
Collection: Nemox Collection
Article Number: 6556-02
- Defogster: Ref. SW1014a RPR-131524 (optional)

Size :- 648x126 x 48H mm No 2.00 0.00

9.1.12 Supply and fix GEESA or Equivalent chrome plated


wall
mounting type soap holder with chrome plated
fastening
screws and other accessories.
Brand:GEESA or Equivalent
Wall mounted soap tray
Collection: Basket Collection
Article Number: 624-C No 152.00 0.00

9.1.13
Supply and fix floor drains made of uPVC circular box
of approved quality for grey water with 4- side
openings, complete with P-smell trap, treaded

drain/clean bottom outlet, approved standard GRADE


SS-304 stainless Steel cover and all other necessary
fittings and accessories
Size:- Dia. 50/50/75/110 mm No 89.00 1,673.00 148,897.00

9.1.14 Supply and fix Kitchen Sink made of 1.54mm thick


Stainless
steel Grade SS 304 having bowl with drain outlet,
GROHE or Equivalent chrome plated brass of
diameter 40mm P-smell trap, drain cover, Overflow
outlet
and all other accessories. The price include
GROHE or Equivalent chrome plated cold and
hot water wall mounted mixer tap (chrome plated
faucet),
Flexible hose to be GROHE or Equivalent and
should be capable of resisting pressure of 4 bar.
Size: 1000 x 500 mm No 2.00 9,870.00 19,740.00
Size: 1500 x 500 mm No 2.00 13,200.00 26,400.00

9.1.12 Supply, fix, test and commission ACO or Equivalent


Factory

made underground type oil/water separator made of

premium-grade fiberglass reinforced plastic (FRP) The


separator should be manufactured as per BS EN
858-1:2002 and BS EN 858-2:2003; Reference 5; shown
in
the layout.
Product holding capacity = 325 Liter
Flow rate = 64 Liter/minute No 1.00 211,200.00 211,200.00

Page 19 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

9.1.13 Supply and fix approved standard set shower box


made of

Acrylic reinforced Fiber tray of minimum 5mm thick,

braced and supported by galvanized metal structure.


Accessories and Fittings include:

- GROHE or Equivalent Chrome plated brass shower


cold and hot water mixer tap

- GROHE or Equivalent Chrome plated brass shower


head, Diameter 150mm
- Chrome plated brass cold and hot water mixing
faucet valve connected to PPR lines

- GROHE or Equivalent Chrome plated brass shower


arm of length = 300mm, with ball joint

- Polypropylene (PP) P-smell trap with 50mm water


seal
- Approved standard overflow pipe
- Approved standard drain pipe

- Approved standard 8mm mm thick tempered glass


Including all the necessary accessories and fittings to
make the system complete and functional. The price
includes all chiseling, plastering and assistant civil
works
Size:- 800mm X 800mm x 13 mm No 1.00 12,100.00 12,100.00

9.1.14 Supply and fix approved quality floor clean outs as


where shown on the drawing. Price shall include all the
necessary connecting pieces.
Dia. 160 mm No 8.00 1,880.00 15,040.00
Dia. 100 mm No 38.00 1,320.00 50,160.00
Dia. 80 mm No 28.00 977.00 27,356.00

9.1.15 Supply and fix PHELEXICARE or Equivalent


Vanity type hand wash basin unit designed to
assist disabled people and those with limited
reach. The vanity top is to be designed with the
bowl area as close as possible to the user.

Vanity Top
The Vaity top is to be made from water-resistant
granite topping. The front apron to have a depth of
only 100mm to allow for free access for knees.
Vanity Top size :535 x 700mm

Basin
hand wash basin to be white vitreous china with
apron front of 100mmand can be fitted to the right
side of the vanity.
Basin size :510 x 455mm

Fixing Brackets
Fitted to the underside of the basin with toggle
bolts and screwed to the undeside of the work top

Accessories
Tap has to be provided separetly for cold and hot
water model should be GROHE/JAQUAR or
Equivalent chrome plated cold and hot water tap,
Complete with mixing battery plug, chrome plated
chain holder, P-smell trap with connection pipe
and with all other necessary accessories. Flexible

Page 20 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

hose to be GROHE/JAQUAR or Equivalent,


Length 60cm to be Vinyle coated and should be
capable of resisting pressure of 4 bar. P-smell trap
should be brass chrome plated with 50mm height
of water seal and trap. Colour of the Granite
topping to be decided by the Architect. No 24.00 31,200.00 748,800.00

9.1.16 Supply and fix PENTLAND or equivalent


Close-coupled white vitreaous china water closet unit
designed to assist disabled people and those with
limited reach. The unit has to be integrated with
close-coupled low-flush 7.5litre capacity cistern. The
unit should be suitable for transfer from a wheel chair.
Flexible hose to be GROHE or Equivalent,
Length 60cm to be Vinyle coated and should be
capable of resisting pressure of 4 bar. P-smell trap
should be brass chrome plated with 50mm height of
water seal and trap. No 24.00 26,400.00 633,600.00

9.1.17 Supply, fix, test and commission VORTICE or


Equivalent hand drier with thermal - protected
indication motor having overheat safety provision
including thermo fuse. The system should be capable
of drying hand in 20 to 30 seconds time and delivery
capacity of 41.7 litres per second. The product should
fully comply with CEI EN 60335-2-23/1997 Standards.
Price include all fixing to walls and assistance civil
works with all accessories to make the system
complete. No 31.00 16,420.00 509,020.00

9.1.18 Supply, fix, test and commission VORTICE or


Equivalent soap dispenser with anti-drip pump for
reliable soap dispensing. The fixture should be
capable to load any type of liquid hand soap. The
covered soap container should be air tight and
capable to avoid evaporation. Also the system should
indicate with light low level soap in the container, and
soap capacity to be 2.6 litre. The system should
comply with the CEI EN 60335-1/1995+A1+A12
Standards. . Price include all fixing to walls and
assistance civil works with all accessories to make
the system complete. No 62.00 18,200.00 1,128,400.00

9.2 WATER SUPPLY PIPES AND FITTINGS

Cold and hot water pipes shall be Polypropylene


Random Co-polymer resins (PP Type 3 raw material)
PPR pipes for cold and hot water , and be fixed to
slabs, walls, beams or etc…with metal straps or similar
material. Unit price shall include all assistance civil
works and necessary fittings such as T, bends etc.
according to where shown on the drawing. All water
pipes shall be tested with pressure of 10kg/cm2
(10bar) at the expense of the contractor.
Unit price shall include, flushing, cleaning and
disinfection of the pipes with liquid Chlorine and all the
necessary assistance to the installation works. Flushing
has to be done to clean the pipeline from debris and
silts. Disinfecting has to be done with liquid chlorin
8-10ppm. All water pipes shall be tested with pressure
of 10kg/cm (10bar). Unit price shall include, installing
insulation to hot water pipes and fittings

9.2.1 Supply and install Polypropylene Random Co-polymer


resins (PP Type 3 raw material) PPR PN-20 to internal
cold and hot water distribution system as shown on the
drawing. Complete with all the necessary fittings and

Page 21 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

accessories. All diameters specified here are external


diameters.
Dia. 20 mm ml 1329.00 172.00 228,588.00
Dia. 25 mm ml 512.00 212.00 108,544.00
Dia. 32 mm ml 194.00 259.00 50,246.00
Dia. 40 mm ml 94.00 328.00 30,832.00
Dia. 50 mm ml 158.00 549.00 86,742.00
Dia. 65 mm ml 127.00 723.00 91,821.00
Dia. 75 mm ml 89.00 995.00 88,555.00

9.2.2 Supply and fix GROHE or Equivalent 15mm dia


chrome plated brass quarter turn angle valves with
chrome plated copper connecting pipe, union nut and
chrome plated brass wall flanges, and accessories

complete in all respects. The Angle valve should be


capable resisting of PN-10 before hand wash basins,
water closets and other fixtures. No 315.00 438.00 137,970.00

9.2.3 Supply and fix PPR service valves of approved


standard, capable of resisting PN-10 on internal branch
and pipe inlet to toilet, kitchen, bath room, etc; of the
following size and as where shown on the drawing.
Dia. 20 mm No 5.00 566.00 2,830.00
Dia. 25 mm No 32.00 894.00 28,608.00
Dia. 32 mm No 17.00 1,422.00 24,174.00
Dia. 50 mm No 2.00 2,120.00 4,240.00

9.2.4 Supply, install, test & commission MALGORANI or


Approved Equivalent Pressure Reducing valve as
indicated in the detail drawing inclusive of all
accessories such as unions, sockets, adptors etc.
Dia. 32mm Set 12.00 6,840.00 82,080.00
Dia. 25mm Set 8.00 4,320.00 34,560.00

9.3 WASTE, VENT AND RAIN WATER PIPES AND


ACCESSORIES

All domestic waste, vent and storm water pipe lines


shall be comply to BS 459, BS 4660, BS 5481 as
appropriate, using double ring seals and gaskets
complying with BS 2394 uPVC, PN-6 pipes and shall
be provided with a minimum slope as stated in the
drawing. Pipes and necessary fittings shall be standard
quality and be free from damage during storage,
construction and etc. Unit price shall include all the
necessary assistance civil works, such as excavation
cartaway, fixing or hanging to walls, beams or slabs.
etc., necessary fittings such as bends, Y, etc. Storm
water uPVC, PN-6 pipes shall resist the external
temperature and the quality shall meet the purpose.
Flushing and testing of waste water system.

Flushing has to be done to clean the pipe line from

debris and silts. All waste water Pipe shall be tested

by water pressure of 1.5 meters head for minimum of


Four Hours.

9.3.1 Providing, laying and jointing of internal uPVC PN-6


waste pipes with all uPVC pipe fittings including
jointing with solvent cement joints and testing of joints
etc. according to where shown on the drawings.
Complete with all the necessary fittings. Provide
cleaning detail for all waste water riser pipes as per the
detail drawing.

Page 22 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

Dia. 50 mm, Outer diameter ml 672.00 286.00 192,192.00


Dia. 75 mm, Outer diameter ml 397.00 321.00 127,437.00
Dia. 110 mm, Outer diameter ml 412.00 579.00 238,548.00
Dia. 160 mm, Outer diameter ml 118.00 829.00 97,822.00

9.3.2 Supply, fix, test and commission Vent caps made of


uPVC, PN-6 complete with all accessories.
Dia. 160 mm No. 1.00 3,240.00 3,240.00
Dia. 110 mm No. 2.00 2,320.00 4,640.00
Dia. 75 mm No. 1.00 1,280.00 1,280.00

9.3.4 Providing, laying and jointing of uPVC PN-6 storm


water down pipes with all uPVC pipe fittings including
jointing with solvent cement joints and testing of joints
etc. according to where shown on the drawings.
Complete with all the necessary fittings.
Dia. 110 mm, Outer diameter ml 126.00 579.00 72,954.00
Dia. 160 mm, Outer diameter ml 386.00 829.00 319,994.00

9.3.5 Supply, Fix and test flat strainers made of GRADE


SS-304 Stainless steel on the roof terminal of storm
water drainage pipes as where shown on the drawing.
Price shall include all the necessary connecting pieces
including gaskets and all water tight connections as
required.
Dia. 110 mm No 3.00 11,200.00 33,600.00
Dia. 160 mm No 6.00 17,280.00 103,680.00

9.3.6 Supply and fix approved quality floor gulley made of


RADEL or Approved equivalent cast iron as where
shown on the drawing with bottom outlet of diameter
110mm. Price shall include all the necessary
connecting pieces. (for parking floor wash drainage)
Size: 300 x 300 mm No 32.00 16,300.00 521,600.00

9.4 WATER PROFFING WORK

SPECIAL CHARACTERSTICS

Surface Preparation: Concrete surface must be clean


and free of dirt, films, coatings or other foreign matter.
All surface imperfections and protrusions are to be
removed and repaired. Structurally unsound and
friable concrete must be removed and repaired.
Responsibility: the contractor should provide the
approved product on site; store it properly in original
unopened packing in dry condition and away from
sunlight and scorching heat. In addition the
application should be made with professionals trained
in the preparation, mixing and application.

Testing: Pond testing for atleast 24 hours should be


done after the contructor has acomplished the water
proffing work. The surface should be re-treated if
leakage observed; and the test should be done on the
repaired surface.

Page 23 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

9.4.1

Supply and coat XYPEX or Equivalent water proffing


as per manufacturers instruction for all wet
areas,toilets, kichen, etc as per Engineer's instruction.
Thecontractor must consider the work as complete set
andprovide appropriate measures for the connection
b/npipes and concrete slab. The application should
alsoconsider application of water proofig 30cm above
theFloor finish level to the walls within the wash room.
After the completion of the work the contractor should
do ponding test using water at level of 20cm from floor
finish level for atleast 24 hours. m2 814.00 533.00 433,862.00

9.4.2
Supply and install TESTUDO or Equivalent, 4mm
thickbitumen plastometric water proofing,
manufactured from a rich mixture of bitumen and
selected polymer blended together to obtain excellent
heat and UV resistant membrane type water proofing
as per manufacturers instruction for all suspended
exposed slabs, terraces, etc as per Engineer's
instruction. The price include thermal insulation on top
of the detail and protection layer above the thermal
insulation. m2 778.00 1,283.00 998,174.00

9.4.3 Supply and install MASTERSEAL 501, SIKA 1 or


Approved Equivalent, integral water proofingto be used
in light weight screed as per manufacturere's
instruction to make slope for all the exposed roofs and
terraces as per Engineer's instruction. The price
include all the assistant civil works. m2 778.00 312.00 242,736.00

9.4.4 Supply and install TESTUDO or Equivalent 4mm thick


membrane type water proffing as per manufacturers
instruction under basement floor slab on 75mm screed
as shown on the drawing. m2 1426.00 585.00 834,210.00

9.4.5 Supply and install MASTERFLEX 610 or Equivalent


Swelling type water bar as per manufacturers
instruction for all basement shear wall construction
joints under under natural ground level as per the
Engineers instruction and detail drawing.
ml 162.00 622.00 100,764.00

9.5 SITE WORK


SITE WATER SUPPLY PIPES
Cold water pipes shall be High Density
Polyethylene( HDPE), PN-10 pipes, and be laid in
trench as
9.5.1 Supply andshown inhigh
install the sanitary
density site drawing. Provide
polyethylene
100mm thickpipes,
pipe,HDPE sand PN-10
beddingto and 150mm
site cold thick
water approved
distribution
materialastoshown
system cover thematerial rammed
on the drawing. and tamped
Complete with all
pipenecessary
the all as perfittings
the typical
and trench section and detail.Unit
accessories.
price shall include all assistance civil works and
necessary
Dia. 20 fittings
mm such as T, bends etc. according to ml 52.00 174.00 9,048.00
where shown on the drawing. All water pipes shall be
Dia. 25 mm ml 48.00 228.00 10,944.00
tested two times the working pressure or 160 meters
Dia.which
head, 32 mm ever is greater at the expense of the ml 59.00 396.00 23,364.00
Dia. 40 mm
contractor. ml 27.00 512.00 13,824.00

Page 24 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

Dia. 50 mm ml 47.00 779.00 36,613.00

9.5.2 Construct slab covered ditch as per the detail drawing.


Price shall include excavation, cart away and all civil
assistance
Supply andworks.
fix GROHE or Equivalent approved ml 177.00 1,230.00 217,710.00
quality garden taps ,complete with gate valve and all
9.5.3 other accessories and connecting pieces.
Dia. 20 mm No 3.00 940.00 2,820.00

9.5.6
Construct manholes on waste water drainage systems
as where shown on the drawing on 150mm thick
reinforced concrete bottom slab in dia.10c.c150mm
both ways and 120mm thick reinforced cover slab in
dia.10c.c150 mm both ways. Price shall include all
assistance civil works and handle.
a) External size: 130x100 cm, with Double brick wall,
25cm average depth = 850 mm No 2.00 14,200.00 28,400.00

b) Internal size: 200x150 cm, with Double brick


wall, 25cm average depth = 1200 mm No 1.00 17,400.00 17,400.00
9.5.7 Ditto, but on storm water line.

a) External size: 130x100 cm, with Double brick wall,


25cm average depth = 850 mm No 7.00 14,200.00 99,400.00

b) Internal size: 200x150 cm, with Double brick


wall, 25cm average depth = 1200 mm No 2.00 17,400.00 34,800.00

9.5.8 Supply and fix diameter 110mm "P" smell trap made of
Upvc, PN-6 on grey water line as indicated in the
drawing with all fittings and accesseries and
connecting pieces. The price includes all assistant civil
works No 2.00 1,208.00 2,416.00

9.5.9 Supply and fix diameter 160mm back flow preventor


made of uPVC, PN-6 on waste water sewer line
connection to municipal system as indicated in the
drawing with all fittings and accesseries and No 1.00 12,300.00 12,300.00
connecting pieces. The price includes all assistant civil
works
GROUND LEVEL WATER TANK

9.5.10 Domestic water storage tank

Supply, install, test and commission Glass Reinfoced


Plastic (GRP) or Equivalent water tanks on the
basement floor as where shown on the drawing.
Accessories
- Dia. 100 mm strainers with foot valve
- Dia. 100 mm HDPE drain and over flow pipe
nearest storm drain manhole (P.Q.)
- Bronze Gate valve on drain pipe, dia. 50mm
- Dia. 100 mm vent pipe with cap
- Dia. 100 mm float valve
- Dia. 100 mm Bronze gate valve on inlet pipe
- Automatic level switch to be connected to domestic
pumps to avoidHDPE
- Dia. 100mm (protect) dry running.
connection pipe with Bronze
gate valve.

Size:- 40 m3 capacity Set 2.00 212,100.00 424,200.00

Page 25 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

9.5.11 Supply and uPVC, PN-6 pipe for waste water drainage
from the manhole to the septic tank with minimum
slope as shown on the drawing or natural ground
slope which ever is greater on a firm bed of sand 150
mm thick below and 200 mm thick above the crown of
pipe in open ground.
Dia. 110 mm, Outer diameter ml 106.00 612.00 64,872.00
Dia. 160 mm, Outer diameter ml 115.00 1,284.00 147,660.00
Dia. 200 mm, Outer diameter ml 8.00 1,643.00 13,144.00

9.5.12
Supply, lay and test uPVC, PN-6 pipe for storm water
drainage from the manhole to the storm water
drainage system with minimum slope as shown on the
drawing or natural ground slope which ever is greater
on a firm bed of sand 100 mm thick below and 200 mm
thick above the crown of pipe in open ground.
Dia. 160 mm, Outer diameter ml 22.00 1,284.00 28,248.00
Dia. 200 mm, Outer diameter ml 36.00 1,984.00 71,424.00
Dia. 250 mm, Outer diameter ml 28.00 1,984.00 55,552.00

Page 26 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

Dia. 160 mm, Outer diameter No 1.00 19,700.00 19,700.00

ELEVATED WATER TANK

9.5.13 Supply and install approved quality FIBERGLASS or


Equivalent elevated water tank on concrete support as
shown on the Sanitary drawing and site plan. Exact
location to be determined on site. Piping should be
made as per the detail drawing
Price shall include all the necessary pipes, fittings and
connections.
- Dia. 75 mm strainers with foot valve
- Dia. 75 mm HDPE drain and over flow pipe
nearest storm drain manhole (P.Q.)
- Bronze Gate valve on drain pipe, dia. 75mm
- Dia. 100 mm vent pipe with cap
- Dia. 75 mm float valve
- Dia. 75 mm Bronze gate valve on inlet pipe
- Automatic level switch to be connected to domestic
pumps to avoid (protect) dry running.
- Dia. 75 mm HDPE connection pipe with Bronze
gate valve.

10m3 capacity Set 2.00 55,770.00 111,540.00

PUMPS AND ACCESSORIES

9.5.14 Domestic water Pump


Supply, fix ,test and commission GRUNDFOSE or
Equivalent approved quality Electric driven centrifugal
domestic transfer water pump with Cast iron impeller,
as per the manufacturer's instruction, technical
specification and drawing shown. Price shall
include:Supply and installation of an efficient and safe
means Domestic water control using pressure vessel
and should be supplied with complete package
incorporating the following components:

- Pressure Vessel (Expansion tank) of 64lt capacity,

PN-6; to BS 5500 made of mild steel, two coats of red


enameled paint over primer outside and two coats of
Epoxy coating inside, and test pressure of 10 Bar.
Capacity : Discharge = 6.7 liters/second
Total head = 95 meters
Estimated power = 6.8 Kw
Efficiency >70%
NPSH >1.5m
- TWO PUMPS: Duty and Stand-by
- Pressure Switches
- Safety valve
- Level Gauge
- Control Panel (IP 55) to IEE Regulations
incorporating the following:
Indicators for - Power on, Pump tripped, High
pressure, Low pressure, Low water Hand (off), Auto
selector switch for each pump And including all the
necessary accessories.
The Price includes:

- 20 cm thick double reinforced with dia. 12/100 mm


reinforced concrete seat
- Bronze gate valve on suction pipe, Diam. 80mm

- Dual plate WAFER type cast iron non - return valve

Page 27 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

Diam. 50mm of Approved standard rated to PN-10,


with bolts, nuts, 3mm thick gasket and matching
flanges.

- Water level indicator for low and high water level in


the water storage for pumps including float type

probes, wiring cable, conduit and making connection


to pump panel complete in all respects and making
system functional, cutting and making good.

- Dry running protection with cable, conduit and fixing


arrangement
- Sensor with panel manual and automatic
change-over and sequancer suitable for the two
pumps.
- supply, fix, test and commission dial type pressure

gauage with isolation cork and chrome plated copper


pipe. Calibration to be 0 - 10 Bar. Set 1.00 283,400.00 283,400.00

9.5.15 Supply and install water meter of approved quality


price shall include gate valves after and before water
meter.
Dia. 32 mm. No 1.00 3,460.00 3,460.00

9.6 SUB SOIL DRAINAGE SYSTEM

9.6.1 Supply and lay purpose made uPVC, PN-6 Factory


slotted plastic pipe to BS 1194:1969 for sub soil
drainage system around the building according to
where shown on the basement floor plan and detail
drawing .
Unit price shall include:
- filling and spreading of coarse gravel, fine gravel,
sand and selected backfill to an average depth of
12meters and average width of 1.2 meter.
- covering of geosynthetics around the gravel pack
(200g)

- TESTIDO or equivalent membrene water proofing,


4mm thick coating in accordance with the drawing.
- Up right position of single brick wall to protect the
membrane water proofing, including all civil assistance
works and screed work in accordance with the detail
drawing.
- well compacted clay soil on the top
- All other necessary connecting pieces and civil
assistance works.
Dia. 160 mm ml 160.00 14,200.00 2,272,000.00

9.6.2 Supply and lay purpose made uPVC, PN-6 Factory


slotted plastic pipe to BS 1194:1969 for sub soil
drainage system into the internal part of the building
according to where shown on the basement floor plan
and detail drawing .
Unit price shall include:

- filling and spreading of coarse gravel, fine gravel,


sand and selected backfill to an average depth of
1.2meters and average width of 0.6 meter.
- covering of geosynthetics around the gravel pack
(200g)
Dia. 160 mm ml 92.00 2,130.00 195,960.00

Page 28 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

9.6.3 Supply and lay rodding or cleaning eye of uPVC, PN-4


on the sub soil drainage system as where shown on
the drawings. Provide plug or screw tube plastic cap
on top to external ground level.
Dia. 160 mm No 4.00 6,340.00 25,360.00

9.6.4 Construct catch pit sump as per the detail drawing.


The reinforced catch pit should be externally protected
with 4mm thick TESTUDO or Equivalent water
proofing membrane and the internal part should be
water proofed using semi elastic cementitious water
proofing; all as per manufacturers instruction and
recommendation. No 1.00 142,300.00 142,300.00

9.6.5 Dewatering pump


Supply,fix,test and commission approved quality
GRUNDFOSE or Equivalent submerrsible dewatering
water pumps as per the manufacturer's instruction,
technical specification and drawing shown. Price shall
include all the necessary valves(one-way and stop
valves) level switch to protect dry-running. (one stand-
by)
Capacity : Discharge = 3 liters/second
Total head = 18 meters
Estimated power = 1.2Kw
Efficiency > 70%

THREE PUMPS: TWO DUTY AND ONE STAND-BY


- Control Panel (IP 55) to IEE Regulations
incorporating the following:
Indicators for - Power on, Pump tripped, High
pressure, Low pressure, Low water Hand (off), Lack of
water and Auto selector switch for each pump
including all the necessary accessories. Set 1.00 171,200.00 171,200.00

TOTAL CARRIED TO SUMMARY ................................................... 13,396,295.00

Page 29 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

10.ELECTRICAL INSTALLATION
Supply and install :-
10. Low Voltage System Earth
10.1.1 Manhole in bricks and with concrete base internally of
600x600x700mm including reinforced concrete cover
with lifting handle. No. 2.00 2,500.00 5,000.00
10.1.2 20x2400mm copper clad earth rod. No 2.00 877.50 1,755.00
10.1.3
2(1x240) sq mm copper earth conductor from MDB,
earthing terminals to Equi potential earth bar No 3.00 2,106.00 6,318.00
10.1.4 1x120 sq mm copper earth conductor from MDB-UPS
earthing terminals to Equi potential earth bar No 12.00 486.00 5,832.00
1.5
1x185 sq sq
2(1x240) mm copper
mm earth
copper conductor
earth from
conductor MDB-MEC
from
earthing terminals to Equi potential
GENERATOR,ATS,COMPCT earth bar earthing
SUBSTATION Ml 8.00 827.55 6,620.40
1.6 terminals to Equi potential earth bar and from EQPEB
to eathing rode. Ml 20.00 2,106.00 42,120.00
1.7 1x240 sq mm bare copper earth conductor from
from EQPEB to eathing rode. Ml 15.00 1,053.00 15,795.00
1.5 Equipotential copper earth bar of 6 terminals withall
necessary acessories. No 2.00 600.00 1,200.00

2. Distribution Boards
2.1 Factory assembled and tested floor standing Central
main distribution Board,MDB in IP 54 sheet steel
enclosure with lockable door and including bus bars
of 2500Amp/3Phase, all necessary fixing and
connecting accessories, the price should include the
concrete mounting pad complete and consisting:-

1 pc Main Air circuit Breaker of 2000A/3P, Icu=32kA

1pc MCCB of 800A/3P, Icu=25kA


1pc MCCB of 500A/3P, Icu=25kA
1pc MCCB of 125A/3P, Icu=16kA
2pc MCCB of 100A/3P, Icu=16kA
1pc MCB of 63A/3P, Icu=10kA
1pc MCB of 32A/3P, Icu=10kA
24pc MCB of 25A/3P, Icu=10kA
3pc MCB of 20A/3P, Icu=10kA
2 pcs MCB of 25A/ 3P,Icu=10KA (SPARE)
1pc surge arrestor of 40KA
3pcs of Ameter 0-2000A
3pcs of current meter 2000A
1pc of voltmeter with selector switch (0-500V)
25% reserve pitch. No 1.00 820,279.50 820,279.50

2.2 Factory assembled and tested Floor standing main


distribution Board, MDB-UPS in IP 54 sheet steel
enclosure with lockable door including bus bars of
630Amp/3Phase, all necessary fixing and connecting
accessories,and consisting:-
1 pc Main MCCB of 500A/3P, Icu=25kA
2pc MCB of 50A/3P, Icu=10kA
17pc MCB of 32A/3P, Icu=10kA
3pcs MCB of 25A/3P, Icu=10kA
2pcs MCB of 25A/1P, Icu=6kA
2 pcs MCB of 32A/ 3P,Icu=10KA (SPARE)
1Pc surge arrestor of 40KA
3pcs of Ameter 0-630A
3pcs of current meter 630A
1pc of voltmeter with selector switch (0-500V)
25% reserve pitch. No 1.00 114,972.00 114,972.00

Page 30 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

2.3 Factory assembled and tested Floor standing main


distribution Board, MDB-MECH in IP 54 sheet steel
enclosure with lockable door including bus bars of
1000Amp/3Phase, all necessary fixing and connecting
accessories,and consisting:-
1 pc Main MCCB of 800A/3P, Icu=25kA
1 pc MCCB of 630A/3P, Icu=16kA
3 pc MCCB of 25A/3P, Icu=10kA
25 pcs MCB of 25A/ 1P,Icu=6KA
2 pcs MCB of 25A/ 1P,Icu=6KA (SPARE)
1Pc surge arrestor of 40KA
3pcs of Ameter 0-400A
3pcs of current meter 400A
1pc of voltmeter with selector switch (0-500V)
25% reserve pitch. No 1.00 183,936.00 183,936.00

2.4 Ditto but for SDB-ROOF/MC with bus bar of


800A/3ph and consisting of:-
1 pc Main MCCB of 630A/3P, Icu=25kA
1pc MCCB of 400A/3P, Icu=16kA
2pc MCCB of 160A/3P, Icu=16kA
1pc MCB of 63A/3P, Icu=10kA
2pcs MCB of 32A/3P, Icu=10kA
4pcs MCB of 16A/3P, Icu=10kA
9pcs MCB of 10A/1P, Icu=6kA
2 pcs MCB of 16A/ 3P,Icu=10KA (SPARE)
1Pc surge arrestor of 40KA
3pcs of Ameter 0-630A
3pcs of current meter 630A
1pc of voltmeter with selector switch (0-500V)
25% reserve pitch. No 1.00 137,989.50 137,989.50

2.5 Factory assembled and tested surface mounted sub


distribution Board,SDB-13F in IP 54 sheet steel
enclosure with lockable door including bus bars of
160Amp/3Phase, all necessary fixing and connecting
accessories,and consisting:-
1 pc Main MCCB of 125A/3P, Icu=25kA
2pc MCB of 63A/3P, Icu=16kA
1pcs MCB of 25A1P, Icu=6kA
5 pcs MCB of 16A/ 1P,Icu=6KA
7 pcs MCB of 10A/ 1P,Icu=6KA
2 pcs MCB of 16A/ 1P,Icu=6KA (SPARE)
3pcs of Ameter 0-400A
3pcs of current meter 400A
1pc of voltmeter with selector switch (0-500V)
25% reserve pitch. No 1.00 33,615.00 33,615.00

2.6 Ditto but for SDB-12F2 with bus bar of 125a/3ph and
consisting of :-
1 pc Main MCCB of 100A/3P, Icu=25kA
2pc MCB of 63A/3P, Icu=16kA
1pcs MCB of 20A1P, Icu=6kA
5 pcs MCB of 16A/ 1P,Icu=6KA
8 pcs MCB of 10A/ 1P,Icu=6KA
2 pcs MCB of 16A/ 1P,Icu=6KA (SPARE)
3pcs of Ameter 0-400A
3pcs of current meter 400A
1pc of voltmeter with selector switch (0-500V)
25% reserve pitch. No 1.00 32,665.95 32,665.95

2.7 Ditto but for SDB-KIT located at 6th floor and consists
of :
1 pc Main MCCB of 100A/3P, Icu=25kA
1pcs MCB of 32A/ 3P,Icu=10KA
2pcs MCB of 25A/ 3P,Icu=10KA
5pcs MCB of 25A/1P, Icu=6kA

Page 31 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

6pcs MCB of 16A/1P, Icu=6kA


1pcs MCB of 10A/1P, Icu=6kA
2 pcs MCB of 25A/ 3P,Icu=6KA (SPARE)
25% reserve pitch. No 1.00 16,672.50 16,672.50

2.90 Factory assembled and tested flush mounted sub


distribution Board, SDB-BS1 in IP 54 sheet steel
enclosure with lockable door including bus bars of
63Amp/3Phase, all necessary fixing and connecting
accessories,and consisting:-
1 pc Main MCB of 20A/3P, Icu=16kA
4pcs MCB of 16A/ 1P,Icu=6KA
8pcs MCB of 10A/ 1P,Icu=6KA
2 pcs MCB of 16A/ 1P,Icu=6KA (SPARE)
25% reserve pitch. No 1.00 6,068.25 6,068.25

2.10 Ditto but for SDB-BS2 and consists of :


1 pc Main MCB of 20A/3P, Icu=16kA
3pcs MCB of 16A/ 1P,Icu=6KA
7pcs MCB of 10A/ 1P,Icu=6KA
2 pcs MCB of 16A/ 1P,Icu=6KA (SPARE)
25% reserve pitch. No 1.00 5,787.45 5,787.45

2.11 Ditto but for SDB-BS3 and consists of :


1 pc Main MCB of 20A/3P, Icu=16kA
1pcs MCB of 20A/ 1P,Icu=6KA
2pcs MCB of 16A/ 1P,Icu=6KA
9pcs MCB of 10A/ 1P,Icu=6KA
2Pc Automatic stair case time lag switch controlled by
illuminated push buttone with Electronic delay
adjustment of 0.5 to 10min coupled with Contactor of
10A/1ph.
2 pcs MCB of 16A/ 1P,Icu=6KA (SPARE)
25% reserve pitch. No 1.00 11,187.45 11,187.45

2.12 Ditto but for SDB-GF and consists of :


1 pc Main MCB of 25A/3P, Icu=16kA
8pcs MCB of 16A/ 1P,Icu=6KA
10pcs MCB of 10A/1P, Icu=6kA
2 pcs MCB of 16A/ 1P,Icu=6KA (SPARE)
25% reserve pitch. No 1.00 6,910.65 6,910.65

2.13 Ditto but for SDB-MZ and consists of :


1 pc Main MCB of 32A/3P, Icu=16kA
5pcs MCB of 16A/ 1P,Icu=6KA
16pcs MCB of 10A/1P, Icu=6kA
2 pcs MCB of 16A/ 1P,Icu=6KA (SPARE)
25% reserve pitch. No 1.00 7,331.85 7,331.85

2.14 Ditto but for SDB-


1F1=2F1=3F1=4F1=5F1=7F1=8F1=9F1=10F1 and
consists of :
1 pc Main MCB of 25A/3P, Icu=16kA
5pcs MCB of 16A/ 1P,Icu=6KA
9pcs MCB of 10A/1P, Icu=6kA
2 pcs MCB of 16A/ 1P,Icu=6KA (SPARE)
25% reserve pitch. No 9.00 5,883.30 52,949.70

2.15 Ditto but for SDB-


1F2=2F2=3F2=4F2=5F2=7F2=8F2=9F2=10F2 and
consists of :
1 pc Main MCB of 25A/3P, Icu=16kA
1pcs MCB of 20A/ 1P,Icu=6KA
5pcs MCB of 16A/ 1P,Icu=6KA
9pcs MCB of 10A/1P, Icu=6kA
2 pcs MCB of 16A/ 1P,Icu=6KA (SPARE)
25% reserve pitch. No 9.00 6,164.10 55,476.90

Page 32 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

2.16 Ditto but for SDB-6F1 and consists of :


1 pc Main MCB of 25A/3P, Icu=16kA
4pcs MCB of 16A/ 1P,Icu=6KA
8pcs MCB of 10A/1P, Icu=6kA
2 pcs MCB of 16A/ 1P,Icu=6KA (SPARE)
25% reserve pitch. No 1.00 5,742.90 5,742.90

2.17 Ditto but for SDB-6F2 and consists of :


1 pc Main MCB of 25A/3P, Icu=16kA
1pcs MCB of 20A/ 1P,Icu=6KA
7pcs MCB of 16A/ 1P,Icu=6KA
11pcs MCB of 10A/1P, Icu=6kA
2 pcs MCB of 16A/ 1P,Icu=6KA (SPARE)
25% reserve pitch. No 1.00 6,910.65 6,910.65

2.18 Ditto but for SDB-11F1 and consists of :


1 pc Main MCB of 25A/3P, Icu=16kA
5pcs MCB of 16A/ 1P,Icu=6KA
8pcs MCB of 10A/1P, Icu=6kA
2 pcs MCB of 16A/ 1P,Icu=6KA (SPARE)
25% reserve pitch. No 1.00 6,208.65 6,208.65

2.19 Ditto but for SDB-11F2 and consists of :


1 pc Main MCB of 25A/3P, Icu=16kA
1pcs MCB of 20A/ 1P,Icu=6KA
5pcs MCB of 16A/ 1P,Icu=6KA
8pcs MCB of 10A/1P, Icu=6kA
2 pcs MCB of 16A/ 1P,Icu=6KA (SPARE)
25% reserve pitch. No 1.00 6,349.05 6,349.05

2.20 Ditto but for SDB-12F1 and consists of :


1 pc Main MCB of 25A/3P, Icu=16kA
7pcs MCB of 16A/ 1P,Icu=6KA
9pcs MCB of 10A/1P, Icu=6kA
2 pcs MCB of 16A/ 1P,Icu=6KA (SPARE)
25% reserve pitch. No 1.00 6,208.65 6,208.65

2.21 Factory assembled and tested flush mounted sub


distribution Boards from ups , UPS-GF in IP 54 sheet
steel enclosure with lockable door including bus bars
of 63Amp/3Phase, all necessary fixing and connecting
accessories,and consisting:-

1 pc Main MCB of 50A/3P, Icu=10kA


19pcs MCB of 16A/ 1P,Icu=6KA
2 pcs MCB of 16A/ 1P,Icu=6KA (SPARE)
25% reserve pitch. No 1.00 7,049.70 7,049.70

2.22 Ditto but for UPS-MZ and consists of :


1 pc Main MCB of 50A/3P, Icu=10kA
14pcs MCB of 16A/ 1P,Icu=6KA
2 pcs MCB of 16A/ 1P,Icu=6KA (SPARE)
25% reserve pitch. No 1.00 6,347.70 6,347.70

2.23 Ditto but for USB-1F1=2F1=3F1=4F1=5F1 and consists


of :
1 pc Main MCB of 32A/3P, Icu=10kA
14pcs MCB of 16A/ 1P,Icu=6KA
2 pcs MCB of 16A/ 1P,Icu=6KA (SPARE)
25% reserve pitch. No 5.00 6,023.70 30,118.50

2.24 Ditto but for USB-1F2=2F2=3F2=4F2=5F2 and consists


of :
1 pc Main MCB of 32A/3P, Icu=10kA
12pcs MCB of 16A/ 1P,Icu=6KA

Page 33 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

2 pcs MCB of 16A/ 1P,Icu=6KA (SPARE)


25% reserve pitch. No 5.00 5,742.90 28,714.50

2.25 Ditto but for USB-1F2=2F2=3F2=4F2=5F2 and consists


of :
1 pc Main MCB of 32A/3P, Icu=10kA
12pcs MCB of 16A/ 1P,Icu=6KA
2 pcs MCB of 16A/ 1P,Icu=6KA (SPARE)
25% reserve pitch. No 5.00 5,742.90 28,714.50

2.26 Ditto but for UPS-6F and consists of :


1 pc Main MCB of 25A/1P, Icu=10kA
2pcs MCB of 16A/ 1P,Icu=6KA
2 pcs MCB of 16A/ 1P,Icu=6KA (SPARE)
25% reserve pitch. No 1.00 1,902.15 1,902.15

2.27 Ditto but for USB-7F1=8F1=9F1=10F1 and consists of :

1 pc Main MCB of 32A/3P, Icu=10kA


15pcs MCB of 16A/ 1P,Icu=6KA
2 pcs MCB of 16A/ 1P,Icu=6KA (SPARE)
25% reserve pitch. No 4.00 6,164.10 24,656.40

2.28 Ditto but for USB-7F2=10F2 and consists of :


1 pc Main MCB of 32A/3P, Icu=10kA
11pcs MCB of 16A/ 1P,Icu=6KA
2 pcs MCB of 16A/ 1P,Icu=6KA (SPARE)
25% reserve pitch. No 2.00 5,602.50 11,205.00

2.29 Ditto but for USB-8F2=9F2 and consists of :


1 pc Main MCB of 32A/3P, Icu=10kA
13pcs MCB of 16A/ 1P,Icu=6KA
2 pcs MCB of 16A/ 1P,Icu=6KA (SPARE)
25% reserve pitch. No 2.00 5,883.30 11,766.60

2.30 Ditto but for USB-11F1 =12F2 and consists of :


1 pc Main MCB of 25A/3P, Icu=10kA
8pcs MCB of 16A/ 1P,Icu=6KA
2 pcs MCB of 16A/ 1P,Icu=6KA (SPARE)
25% reserve pitch. No 2.00 5,181.30 10,362.60

2.31 Ditto but for USB-11F2 and consists of :


1 pc Main MCB of 25A/3P, Icu=10kA
10pcs MCB of 16A/ 1P,Icu=6KA
2 pcs MCB of 16A/ 1P,Icu=6KA (SPARE)
25% reserve pitch. No 1.00 5,462.10 5,462.10

2.32 Ditto but for USB-12F1 and consists of :


1 pc Main MCB of 25A/1P, Icu=10kA
4pcs MCB of 16A/ 1P,Icu=6KA
2 pcs MCB of 16A/ 1P,Icu=6KA (SPARE)
25% reserve pitch. No 1.00 2,042.55 2,042.55

2.33 Ditto but for SDB- GF/MC=MF/MC


1F/MC1=2F/MC1=3F/MC1=4F/MC1=5F/MC1=7F/
MC1=8F/MC1=9F/MC1=10F/MC1 and consists of :

1 pc Main MCB of 25A/1P, Icu=10kA


15pcs MCB of 10A/ 1P,Icu=6KA
2 pcs MCB of 10A/ 1P,Icu=6KA (SPARE)
25% reserve pitch. No 11.00 4,941.00 54,351.00

2.34 Ditto but for SDB-


1F/MC2=2F/MC2=3F/MC2=4F/MC2=5F/MC2=7F/
MC2=8F/MC2=9F/MC2=10F/MC2 and consists of :

1 pc Main MCB of 25A/1P, Icu=10kA

Page 34 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

14pcs MCB of 16A/ 1P,Icu=6KA


2 pcs MCB of 16A/ 1P,Icu=6KA (SPARE)
25% reserve pitch. No 9.00 4,800.60 43,205.40

2.35 Ditto but for SDB-6F/MC and consists of :


1 pc Main MCB of 25A/1P, Icu=10kA
4pcs MCB of 16A/ 1P,Icu=6KA
2 pcs MCB of 16A/ 1P,Icu=6KA (SPARE)
25% reserve pitch. No 1.00 2,182.95 2,182.95

2.36 Ditto but for SDB-11F/MC1 and consists of :


1 pc Main MCB of 25A/1P, Icu=10kA
12pcs MCB of 16A/ 1P,Icu=6KA
2 pcs MCB of 16A/ 1P,Icu=6KA (SPARE)
25% reserve pitch. No 1.00 3,306.15 3,306.15

2.37 Ditto but for SDB-11F/MC2 and consists of :


1 pc Main MCB of 25A/1P, Icu=10kA
12pcs MCB of 12A/ 1P,Icu=6KA
2 pcs MCB of 16A/ 1P,Icu=6KA (SPARE)
25% reserve pitch. No 1.00 3,306.15 3,306.15

2.38 Ditto but for SDB-12F/MC1 and consists of :


1 pc Main MCB of 25A/1P, Icu=10kA
10pcs MCB of 16A/ 1P,Icu=6KA
2 pcs MCB of 16A/ 1P,Icu=6KA (SPARE)
25% reserve pitch. No 1.00 3,025.35 3,025.35

2.39 Ditto but for SDB-12F/MC2 and consists of :


1 pc Main MCB of 25A/1P, Icu=10kA
11pcs MCB of 16A/ 1P,Icu=6KA
2 pcs MCB of 16A/ 1P,Icu=6KA (SPARE)
25% reserve pitch. No 1.00 3,165.75 3,165.75

2.40 Surface mounted metal enclosures sub distribution


board SDB-P with lockable door, earthing lead, cable
terminal,labeling ,connectors and all the necessary
accessories consisting of:-
1Pc main MCB of 63A, 3-ph Icu=10KA
3Pcs MCB of 25A, 3ph Icu=10KA
2Pcs MCB of 6A, 1ph Icu=6KA
2pcs of contactors of 25A/3ph ,contact of 220/240
,coupled with thermial overload relay setting for
12KW motor.
4Pcs mercury float switch for each pump for min &
max level control inside elevated tank ,for min level
control, inside a reservoir . Manual control with
selector switch of 25A/3ph for two pumps junction
boxes with complete accessories for controlling water
pump system all complete.
4pcs pilot lump
3pcs of Ameter 0-80A
3pcs of current meter 80A
1pc of voltmeter with selector switch (0-500V)
complet with star delta starter
with busbar 80A and 25% reserve space. No 1.00 40,000.00 40,000.00

3.Feeder Cables and PVC pipes


PVC Sheathed PVC Insulated power cable type NYY
0.6/1KV or equivalent to be drawn inside riser shaft or
PVC conduit (measured elsewhere) and of :-
3.1 3x240/120+120sq.mm from MDB-to MDB-UPS ml 10.00 4,037.85 40,378.50
3.2 2(3x185/95)sq.mm from MDB-to MDB-MEC ml 5.00 5,526.90 27,634.50
3.3 2(3X150/70)+150sq.mm from MDB-MEC to SDB-
ROOF/MC ml 70.00 4,912.65 343,885.50

Page 35 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

3.4 3x50/25+1x25sq.mm MDB-to -SDB-13F ml 100.00 842.40 84,240.00


3.5 3x35/16+1x16sq.mm from MDB-to SDB-12F2,SDB-KIT
ml 131.76 603.45 79,507.86
3.6 5x10sq.mm ml 87.89 253.80 22,305.85
3.7 5x16sq.mm ml 20.00 371.25 7,425.00
3.8 5x6sq.mm ml 2380.50 141.75 337,435.88
3.9 5x4sq.mm ml 30.00 74.93 2,247.75
3.10 3x6 sq.mm ml 132.00 86.40 11,404.80
3.11 3x6 sq.mm ml 2513.00 86.40 217,123.20
0.00
4.Light Points 0.00
4.1 Flush mounted light points fed through PVC insulated
cables of 2x2.5mm2 inside PVC conduits of 16mm
diameter, including junction boxes with covers and
insulating screw cap connectors, complete
No 3046.00 310.00 944,260.00

5. Extra Over Light Points for Flush Mounted


Switches(Type Legrand ARTIOR or Equivalent)
5.1 Flush mounting single switch, No 76.00 81.00 6,156.00
5.2 Flush mounting 2 gang single switch, No 120.00 166.05 19,926.00
5.3 Flush mounting two way switch, No 50.00 158.00 7,900.00

Isolator switch
5.4 7pcs,1ph,16A isolator switch in box with lockable 2.00
doors No 2,430.00 4,860.00
5.5 8pcs,1ph,16A isolator switch in box with lockable 1.00 2,700.00
doors No 2,700.00
5.6 9pcs,1ph,16A isolator switch in box with lockable 1.00 2,700.00
doors No 2,700.00

Occupancy sensors
5.7 Occupancy and/or motion sensors ,legrand 488 22
dual (passive infrared & ultrasonic technology)
Ceiling mounting SCS lighting management sensor
360deg. infra red and ultrasonic detection ,occupancy
mode (automatic on/automatic off factory
setting,check presence and light level continuosly.) +
room controller legrand 488 50, 2 out puts 16A . the
dual technology sensor and the room controller control
2 zones.+commisioning tools 882 30 to modify factory
seting if needed , With all necessariy accesories to
make the system complet. No 75.00 12,000.00 900,000.00
5.8 Occupancy and/or motion sensors ,legrand 488 06
dual (passive infrared & ultrasonic technology)
Ceiling mounting lighting management sensor
360deg. infra red and ultrasonic detection ,occupancy
mode (automatic on/automatic off factory
setting,check presence and light level continuosly.)
+commisioning tools 882 30 to modify factory seting if
needed , With all necessariy accesories to make the
system complet. No 63.00 6,000.00 378,000.00

5.9 Occupancy and/or motion sensors ,legrand 488 30 PIR


(passive infrared technology) corner mounting SCS
lighting management sensor 270deg. infra red
,occupancy mode (automatic on/automatic off factory
setting,check presence and light level continuosly.) +
room controller legrand 488 50, 2 out puts 16A
+commisioning tools 882 30 AND 35 to modify
factory seting if needed , With all necessariy accesories
to make the system complet. No 5.00 6,000.00 30,000.00

6 Flush Mounted Socket Outlet Points

Page 36 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

6.1 16A/1P socket outlet points fed through PVC insulated


conductors of 3x2.5mm2 inside PVC conduit of 16mm
diameter including junction boxes with covers and
insulating screw cap connectors. No 1249.00 310.00 387,190.00
6.2 20A/1P socket outlet points fed through PVC shethed
Cable of 3x4mm2 inside PVC conduit of 20mm
diameter including junction boxes with covers and
insulating screw cap connectors. No 12.00 583.20 6,998.40
6.3 25A/1P socket outlet points fed through PVC shethed
Cable of 3x6mm2 inside PVC conduit of 20mm
diameter including junction boxes with covers and
insulating screw cap connectors. No 6.00 788.40 4,730.40
6.4 32A/3P socket outlet points for oven fed through PVC
shethed Cable of 5x6mm2 inside PVC conduit of
25mm diameter including junction boxes with covers
and insulating screw cap connectors. No 7.00 1,263.60 8,845.20
7 Power Outlets 0.00
0.00
7.1 25A/1p Power outlet point for coffee machine and fed
through PVC sheathed cable of 3x6 sqmm in PVC
conduits of 25mm diameter including junction boxes
with covers and insulating screw cap connectors. ml 2.00 1,478.25 2,956.50
7.2 25A/3p Power outlet point for cold room and fed
through PVC sheathed cable of 5x6 sqmm in PVC
conduits of 25mm diameter including junction boxes
with covers and insulating screw cap connectors. ml 2.00 1,263.60 2,527.20

7.3 63A/3p Power outlet point for Lift machine fed


through PVC sheathed cable of 5x10 sqmm in PVC
conduits of 50mm diameter including junction boxes
with covers and insulating screw cap connectors.
(Average length 10m) ml 4.00 5,973.75 23,895.00

7.4.Power Outlets for mechanical system

7.4.1 16A/1P power outlet points for fan coil units fed
through PVC shethed Cable of 3x2.5mm2 inside PVC
conduit of 16mm diameter including junction boxes
with covers and insulating screw cap connectors. No 336.00 400.00 134,400.00
0.00
7.4.2 16A/1P power outlet points for kitchen hood and jut
fans fed through PVC shethed Cable of 3x2.5mm2
inside PVC conduit of 25mm diameter including
junction boxes with covers and insulating screw cap
connectors. No 22.00 400.00 8,800.00
0.00
7.4.3 16A/3P power outlet points fed through PVC shethed
Cable of 5x2.5mm2 inside PVC conduit of 25mm
diameter including junction boxes with covers and
insulating screw cap connectors. No 5.00 693.90 3,469.50
0.00
7.4.4 32A/3P power outlet points for Confrence AHU
Chiller fed through PVC shethed Cable of 5x6mm2
inside PVC conduit of 29mm diameter including
junction boxes with covers and insulating screw cap
connectors.(Average length =15m) No 2.00 1,263.60 2,527.20

Page 37 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

7.4.5 63A/3p Power outlet point for air handling unit fed
through PVC sheathed cable of 5x16 sqmm in PVC
conduits of 50mm diameter including junction boxes
with covers and insulating screw cap connectors.
(Average length 15m) ml 1.00 5,973.75 5,973.75

7.4.6 160A/3p Power outlet point for AIR COOLED


CHILLER r fed through PVC sheathed cable of
3x75/35+35 sqmm in PVC conduits of 110mm
diameter including junction boxes with covers and
insulating screw cap connectors.(Average length 15m) ml 2.00 18,483.80 36,967.59
0.00
7.4.7 400A/3p Power outlet point for Confrence Room
chiller fed through PVC sheathed cable of
3x185/95+95 sqmm in PVC conduits of 110mm
diameter including junction boxes with covers and
insulating screw cap connectors.(Average length 15m) ml 1.00 48,539.25 48,539.25

8. Flush Mounted Socket Outlets with Earth Contact


(Type Legrand ARTIOR or Equivalent)
8.1 Flush mounting socket outlet of 10-16A/1P No 597.00 100.00 59,700.00
8.2 Flush mounting socket outlet of 16A/1P with switch
for water heater No 3.00 249.75 749.25
8.3 Flush mounting Red twin socket outlet from UPS No 207.00 526.50 108,985.50
8.4 Flush mounting socket outlet 16A/1P suitable for
hand dryer AC plug. No 30.00 249.00 7,470.00
8.5 Flush mounting socket outlet 20A/1P with switch
sutable for stove No 12.00 506.25 6,075.00
8.6 Surface mounted 32A/3ph socket with switch for oven No 1.00 1,323.00 1,323.00

Pop up Type Floor Box.


-Floor box shall be fixed neatly in contact with the
horizontal surface of the Floor with the necessary fixers
or connectors with IP 54 enclousures and maximum
depth of 5cm
-Floor box ,data,socket and telephone out lets shall be
the product of the same manfacture.

8.7 Floor box with coressponding metal under floor box


consisting of 3pcs 8 contact RJ45 data socket outlet(for
data and tele), and 4pcs red socket out let for UPS . 12
MODUEL ,2PC OF 6 (2X3)MODUEL ,4S,2D,1T
,LEGRAND ‐ 0 540 12
COLOR= Matt aluminium finish No 393.00 4,146.91 1,629,736.42
8.8 Ditto but for 3pcs 8 contact RJ45 for data & tele socket
outlet,4pcs red socket out let for UPS and 1pc Tv
socket outlet and 1pc VGI outlet . 4S,2D,VGI, No 1.00 4,146.91 4,146.91
8.9 Ditto but for 4pcs 8 contact RJ45 for data socket
outlet,4pcs red socket out let for UPS . 4S,4D No 12.00 4,146.91 49,762.94
8.10 Floor box with coressponding plastic under floor box
consisting of 2pcs 8 contact RJ45 for data and tele
socket outlet,2pcs red socket out let for UPS socket
6 MODUEL ,1PC OF 6 (2X3)MODUEL ,2S,1D,1T
LEGRAND ‐ 0 540 12
COLOR= Matt aluminium finish No 14.00 2,073.46 29,028.37
0.00
Automatic Hand Dryer 0.00
8.11 Supply and install 220V/50HZ automatic hand dryer
with heating temperature of 40-60 degree Celsius with
dynamical balanced centrifugal fan of multiple metalic
vanes, fire retardant, high gloss finish plastic cover
and mounting base, infrared sensors complete with all
the accessories . No 30.00 5,500.00 165,000.00

Page 38 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

0.00
9.Data /Tele system 0.00
Horizontal cabling 0.00
9.1 RJ 45, 8 contact data socket out let points to for flush
mounting in thermoplastic conduit of 20mm with
appropriate type junction box fed by standard (CAT 6
UTP data cable) for 10/100 base internet with RJ 45
connector plug to be fixed on patch pannel data
transfer rate of min.100Mbs and the necessary
accessories to make the system complete. No 22.00 1,296.00 28,512.00
9.2 RJ 45, 8 contact data/tele socket out let points to for
flush mounting in thermoplastic conduit of 20mm
with appropriate type junction box fed by standard (2X
CAT 6 UTP data /Tele cable) for 10/100 base internet
with RJ 45 connector plug to be fixed on patch pannel
data transfer rate of min.100Mbs and the necessary
accessories to make the system complete. No 197.00 2,268.00 446,796.00
9.3 Ditto but for floor box partly in cable tray and partly
in termoplastic condiut of 29mm fed by (4 x CAT6 UTP
data /tele cable ). No 24.00 3,726.00 89,424.00
9.4 Ditto but for floor box partly in cable tray and partly
in termoplastic condiut of 29mm fed by (3 x CAT6 UTP
data/tele cable ). No 395.00 2,997.00 1,183,815.00

Extra over Data socket out lets with detachable


frames & corresponding box (Type Legrand Suno or
Approved equivalent)

9.5 2xRJ 45 8contact cat 6 Data /tele socket out lets No 172.00 1,113.75 191,565.00
9.6 RJ 45 8contact cat 6 Data /tele socket out lets No 15.00 664.20 9,963.00
9.7 RJ 45 8contact cat 6 I P TV outlet No 4.00 664.20 2,656.80

Wifi access points


Manageable Wi-Fi access points 802.11a & b/g
9.8 Dual-band and dual-radio
Conform with standards 802.11a and 802.11b/g
Gross speed: 54 Mbps max. on each frequency
(802.11a and 802.11g) simultaneously
Can be integrated into all compatible supports with
minimum 40 mm depth Equipped with an RJ 45 socket
on the
front panel
Tool-free network connection via RJ 45 connector
PoE power supply (Power over Ethernet - standard
802.3 af)
The management function allows the network
administrator to manage Wi-Fi access points remotely
via a web interface
Security via WPA2 encryption (802.11i) and 802.1x
authentication
Guest access: allows visitors free access to the Internet
(access independent of the main Wi-Fi network)
No 3.00 7,500.00 22,500.00

Data Cables patch pannel

Page 39 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

9.9 Supply, install, leble, test and commission free


standing 47U, 19" steel enclosure at server room
PP/MAIN with transparent and lockable door ,knock-
out holes for cable entrance and conduit connection,
ventilation fan,screen lable holder and including
reserve space for hubs and switches,complete
connection and all the necessary accessories
consisting:-

6pc cat 6 , 24port patch panel, RJ 45 8 contacts for


horizontal cabling (Both Data and telephone)(144port) .
(6U)
3pc voice patch panel, 24port contacts for 70pair
vertical telephone cable (3U)
9pc cable organizer, (9U)
1pc PDU with 8 shuko socket outlets (1U)
7 pcs 2in 2 out PoE injector for 13 CCTV points.(3U)
8U reserve space with 4shelves for Switces.
Fiber to copper convertor,fiber optic drawer and fiber
optic unit to accommodate 22 multimode fiber back
bone cables. Standard (2m) patch cords ,And all
necessary accessories to make the system complete. No 1.00 87,680.00 87,680.00

9.1 Supply, install, leble, test and commission free


standing 24U, 19" steel enclosure at server room
PP/MF with transparent and lockable door ,knock-out
holes for cable entrance and conduit connection,
ventilation fan,screen lable holder and including
reserve space for hubs and switches,complete
connection and all the necessary accessories
consisting:-

4pc cat 6 , 24port patch panel, RJ 45 8 contacts for


horizontal cabling (Both Data and telephone)(96port) .
(4U)
2pc voice patch panel, 24port contacts for 30pair
vertical telephone cable (2U)
6pc cable organizer, (6U)
1pc PDU with 8 shuko socket outlets (1U)
2 pcs 2in 2 out PoE injector for 4 CCTV points.(1U)
6U reserve space with 3shelves for Switces.
Fiber to copper convertor,fiber optic drawer and fiber
optic unit to accommodate 1 multimode fiber back
bone cables. Standard (2m) patch cords ,And all
necessary accessories to make the system complete. Nº 1.00 61,880.00 61,880.00
9.11 Supply, install, leble, test and commission 21U,
standard pivoting cabinate
PP/1F-1=2F1=3F1=4F1=7F1=8F1=9F1=10F1 19"
steel enclosure with transparent and lockable door
,knock-out holes for cable entrance and conduit
connection, ventilation fan,screen lable holder
standard pivoting cabinet with rack for wall mounting
and including reserve space for hubs and
switches,complete connection and all the necessary
accessories consisting:-

3pc cat 6 , 24port patch panel, RJ 45 8 contacts for


horizontal cabling (Both Data and telephone)(72port) .
(3U)
1pc voice patch panel, 24port contacts for 30pair
vertical telephone cable (1U)
4pc cable organizer, (4U)
1pc PDU with 8 shuko socket outlets (1U)
2 pcs 2in 2 out PoE injector for 4 CCTV points.(1U)
4U reserve space with 2shelves for Switces.

Page 40 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

Fiber to copper convertor,fiber optic drawer and fiber


optic unit to accommodate 1 multimode fiber back
bone cables. Standard (2m) patch cords ,And all
necessary accessories to make the system complete. No 8.00 52,530.00 420,240.00

9.12 Supply, install, leble, test and commission 16U,


standard pivoting cabinate, PP/1F-
2=2F2=3F2=4F2=5F2=7F2= 8F2=9F2=10F2 ,19" steel
enclosure with transparent and lockable door ,knock-
out holes for cable entrance and conduit connection,
ventilation fan,screen lable holder standard pivoting
cabinet with rack for wall mounting and including
reserve space for hubs and switches,complete
connection and all the necessary accessories
consisting:-

3pc cat 6 , 24port patch panel, RJ 45 8 contacts for


horizontal cabling (Both Data and telephone)(72port) .
(3U)
1pc voice patch panel, 24port contacts for 30pair
vertical telephone cable (1U)
4pc cable organizer, (4U)
1pc PDU with 8 shuko socket outlets (1U)
4U reserve space with 2shelves for Switces.
Fiber to copper convertor,fiber optic drawer and fiber
optic unit to accommodate 1 multimode fiber back
bone cables. Standard (2m) patch cords ,And all
necessary accessories to make the system complete. No 9.00 47,430.00 426,870.00

9.13 Supply, install, leble, test and commission 21U,


standard pivoting cabinate, PP/5F-1 ,19" steel
enclosure with transparent and lockable door ,knock-
out holes for cable entrance and conduit connection,
ventilation fan,screen lable holder standard pivoting
cabinet with rack for wall mounting and including
reserve space for hubs and switches,complete
connection and all the necessary accessories
consisting:-

4pc cat 6 , 24port patch panel, RJ 45 8 contacts for


horizontal cabling (Both Data and telephone)(96port) .
(4U)
2pc voice patch panel, 24port contacts for 30pair
vertical telephone cable (2U)
6pc cable organizer, (4U)
1pc PDU with 8 shuko socket outlets (1U)
4 pcs 2in 2 out PoE injector for 4 CCTV points.(2U)
6U reserve space with 3shelves for Switces.
Fiber to copper convertor,fiber optic drawer and fiber
optic unit to accommodate 1 multimode fiber back
bone cables. Standard (2m) patch cords ,And all
necessary accessories to make the system complete. Nº 1.00 77,180.00 77,180.00

9.14 Supply, install, leble, test and commission 16U,


standard pivoting cabinate, PP/11F1,19" steel
enclosure with transparent and lockable door ,knock-
out holes for cable entrance and conduit connection,
ventilation fan,screen lable holder standard pivoting
cabinet with rack for wall mounting and including
reserve space for hubs and switches,complete
connection and all the necessary accessories
consisting:-

2pc cat 6 , 24port patch panel, RJ 45 8 contacts for


horizontal cabling (Both Data and telephone)(48port) .
(2U)

Page 41 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

1pc voice patch panel, 24port contacts for 30pair


vertical telephone cable (1U)
3pc cable organizer, (4U)
1pc PDU with 8 shuko socket outlets (1U)
2 pcs 2in 2 out PoE injector for 3 CCTV points.(2U)
4U reserve space with 2shelves for Switces.
Fiber to copper convertor,fiber optic drawer and fiber
optic unit to accommodate 1 multimode fiber back
bone cables. Standard (2m) patch cords ,And all
necessary accessories to make the system complete. No 1.00 38,860.00 38,860.00

9.15 Ditto but for PP/11F2 and consisting of :


2pc cat 6 , 24port patch panel, RJ 45 8 contacts for
horizontal cabling (Both Data and telephone)(48port) .
(2U)
1pc voice patch panel, 24port contacts for 30pair
vertical telephone cable (1U)
3pc cable organizer, (4U)
1pc PDU with 8 shuko socket outlets (1U)
4U reserve space with 2shelves for Switces.
Fiber to copper convertor,fiber optic drawer and fiber
optic unit to accommodate 1 multimode fiber back
bone cables. Standard (2m) patch cords ,And all
necessary accessories to make the system complete. No 1.00 26,860.00 26,860.00
9.16 Ditto but for PP/12F and consisting of :
3pc cat 6 , 24port patch panel, RJ 45 8 contacts for
horizontal cabling (Both Data and telephone)(72port) .
(3U)
1pc voice patch panel, 24port contacts for 30pair
vertical telephone cable (1U)
3pc cable organizer, (4U)
1pc PDU with 8 shuko socket outlets (1U)
2 pcs 2in 2 out PoE injector for 4 CCTV points.(2U)
4U reserve space with 2shelves for Switces.
Fiber to copper convertor,fiber optic drawer and fiber
optic unit to accommodate 1 multimode fiber back
bone cables. Standard (2m) patch cords ,And all
necessary accessories to make the system complete. No 1.00 47,260.00 47,260.00

Back bone cabling


9.17 Back bone cabling for flush mounting in
thermoplastic conduit of 16mm with approporate type
junction box fed by standard standard multi mode
Fiber optics data cable for 10/100 base entarnet with
standard connector plug to be fixed on patch pannel
/switch/ hub data transfer rate of 1Gbs and the
necessary accessories to make the system complete. No 22.00 33,680.00 740,960.00

Telephone Distrubution Frame


9.18 750 pair Main telephone distribution frame MDF in
matal sheet inclosure with locable door and all
necessary acesseries to make the system complete.As
per ETC standard No 1.00 24,000.00 24,000.00

Telephone Distrubution cables

9.19 30 pairs telephone cable in PVC dia.50mm or


equivalent pair as ETC standard ml 550.00 91.80 50,490.00

9.20 10 pairs telephone cable in PVC dia.50mm or


equivalent pair as ETC standard ml 20.00 75.00 1,500.00

10.UPS

Page 42 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

10.1
Approved type 3in, 3 out parallel operating 2x150KVA
UPS with maintenance free sealed lead acid battery
life time of minimum 5years, LED status display with
battery bar graph for on line, replace battery and over
load indicator static electronics manual by pass switch
for 10min operation with surge protector .utility for
parallel connection including paralleling moduel ,
power factor of grater or equal 0.9and all the necessary
accessories. With 2 years guarantee certificate and
factory test report.
No 1.00 ### 2,500,000.00

11. CABLE SUPPORT SYSTEMS


(cable Tray And Cable Ladder)
Note: all installation including support distance should be in
accordance with manufacturer's instructions and / or as shown
on the drawings.

CABLE TRAY

11.1 -All cable tray shall run neatly and fixed in


contact with the horizontal and vertical corner
of the wall with the necessary drops and riser.
-The cable tray must consisting of accessories
like clamp kit,coupling plate ,cable mounting bracket ,
grounding cable drop out plate ,elbows and T-joints for
horizontal,bracket,mounting box support, suspension
bracketend cap,cable retainer,hinge connector for vertical
change in direction,wall and pendent bracket for wall
support ,box for cable junctions for all the necessary acessories
11.1
60mmx400mm for voice/data cables+60mmx200mm
for power cables. Refer cable tray detail m 800.00 1,200.00 960,000.00

11.2
60mm x200mm for voice/data cables+60mmx200mm
for power cables. Refer cable tray detail m 100.00 900.00 90,000.00

CABLE LADDER

Hot dip galvanized after fabrication, cable ladder,


Niedax, Wibe orapproved equivalent including joint,
elbows and T-joints for horizontal change in direction,
hinge connector for vertical change in direction,wall &
pendant brackets for support from the wall and ceilling
respectively, complete with connectors and other fixing
accessories, and of:
11.3 A-60mm x400mm for voice/data cables through risers. m 55.00 650.00 35,750.00
11.4 B-60mmx400mm for low voltage cables through risers. m 60.00 650.00 39,000.00
11.5 B-60mmx500mm for low voltage cables power entry m 20.00 760.00 15,200.00

12.PVC Pipe for tele and data distrbution


12.1 Diameter 110mm m 300.00 130.00 39,000.00
12.2 Diameter 50mm m 300.00 80.00 24,000.00
12.3 Diameter 32mm m 1200.00 50.00 60,000.00

13. Light Fittings and Lamps

Page 43 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

(Specified Type or Approved Equivalent)


13.1 (Type-1)Lacrue LEDS.C4 EQUAL L 90-2069-14-M3 18w
No 225.00 7,020.00 1,579,500.00
13.2 (Type-2)FRATER FRM 114 WITH T5 1X14W lamp No 54.00 800.00 43,200.00
13.3 (Type-3)FRATER FRR236 modular recesed with T5
2x28w lamp 56.00 1,800.00 100,800.00
13.4 (Type-4)Lacrue LEDS.C4 FIT 15-4723-54-M1 LED max
40W No 1251.00 7,200.00 9,007,200.00
13.5 (Type-4')Lacrue LEDS.C4 FIT 15-4723-54-M1E LED
max 40W with 3h emergency kit. No 173.00 8,500.00 1,470,500.00
13.4 (Type-5)Lacrue LEDS.C4 EQUAL L 90-0931-14-M3
with 18led max 39w. No 586.00 7,200.00 4,219,200.00
13.5 (Type-6)Lacrue LEDS.C4 ROCKET OO-3280-16-16 LED
CREE 6X2.2W. No 12.00 9,500.00 114,000.00
13.6 (Type-6')Lacrue LEDS.C4 ROCKET OO-3279-16-16
LED CREE 1X2.2W. No 3.00 3,000.00 9,000.00
13.7 (Type-7)FRATER FRSP 128 SURFACE PRISMATIC
with T5 1x28w lamp No 82.00 1,200.00 98,400.00
13.8 (Type-8)Lacrue LEDS.C4 GEA 55-9665-CA-37 WTH
9LED9W MAX. 13.00 7,500.00 97,500.00
13.9 (Type-9)Lacrue LEDS.C4 EXIT 90-320814-37 LED 26W
MAX. No 111.00 7,200.00 799,200.00

Emergency Lighting System


13.10 Type E1=DISANO 613 Safety- emergency+1x18w lamp
+ acc.323 99522-00. emergency lighting system shall be
installed with standard dimensions as indicated on the
drawings throughout building for the convenient of
the public and workers. The system shall provide
safety evacuation of public during emergency for with
at least of 2hr emergency battery No 130.00 5,200.00 676,000.00

Illuminated Signage System


Flush ceiling type or wall surface
13.11 DISANO 615 safty only emergency with FLC 11SE or
approved equivallent illuminated signage system shall
be installed to give information with standard
dimensions information displays and illumination
level with double or single faces. The
display consisting of symbols, text or figures
supported with direction which will indicate EXIT,
toilets (lady and gentlemen), staircases and floor level
will be placed as indicated on the drawings throughout
building for the convenience of the public and workers
.The symbols, text or figures shall be choices of the
client or engineer and shall be appropriate enough to
describe the room, areas, services and all safety
directions it should have emergency battery for at least
2 hours . No 92.00 5,200.00 478,400.00

14. Lightning Arrester System


(Eritech or Equivalent)
Shall include all metalic structures in the network with
appropriate welding (ventpipes,ducts ,GIS roof &
structures e.t.c)

14.1 Early Streamer Emmision(ESE) Protector SI 60 with


mounting mast of H=2m and all necessary connecting
acessories. No 1.00 39,000.00 39,000.00
14.2 25x3mm copper tape with all necessary roof
connecting accessories m 20.00 445.00 8,900.00
0.00
Down conductor 0.00

Page 44 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

14.3 25 x 3mm insulated copper tape with vertical


supportings every 1m to the wall & all the necessary
accessories coordinate the routing of down conductors
with the building external skin and architectural
features.
ml 70.00 445.00 31,150.00
14.4 50 x 50 x 50 cm test pit with top cover inscribed "Test
pit" as per the detail drawing No 3.00 2,500.00 7,500.00
14.5 1 x 70 sq.mm bare copper wire ml 20.00 274.05 5,481.00
14.6 Diameter 16mm & 1500mm long copper rod No 3.00 573.75 1,721.25

15.Public addressing and sound system

Speaker points
15.1 Speaker points in thermoplastic conduit of 13 mm
fed through standard 2x1.5 audio cable with all the
necessary accessories No 150.00 310.00 46,500.00

Page 45 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

Public Addressing system


Public address equipment, supplied, installed,
connected, tested and commissioned including control
speaker cables,conduits and all necessary accessories,
complete as shown on drawings

15.2 PA Network controller to be mounted in a 19"'rack


with built in 240 watt amplifier No. 1.00 185,000.00 185,000.00
15.3 background music MP3 player for video and audio
• Supports MP3
• FM/AM tuner with 10 presets and digital control
19" rack. Type BOSCH PLE SDT or approved
equivalent.

No. 1.00 35,000.00 35,000.00


Bosch 240W booster amplifier BOSCH PLE 1P 240EU
15.4 No 6.00 44,250.00 265,500.00
BOSCH Six Zone call station compatable with network
15.5 controller No. 4.00 38,200.00 152,800.00
BOSCH 6 zone Call station keypad for call station basic
15.6 No. 4.00 24,500.00 98,000.00
Approved type Line supervision set with complete
15.7 accessories No. 9.00 7,850.00 70,650.00
15.8 Configuration/diagnostic & logging software No. 1.00 95,000.00 95,000.00
Ceiling Recessed speakers with power rating of 5W'
RMS, minimum shall be provided with the necessary
accessories, Speaker back box shall be recessed type
15.9 BOSCH BCS-CS5E or approved equivalent. No 125.00 7,500.00 937,500.00
Software's, documentation, instruction of owner's
15.10 staff,'power supplies/transformers. LS 1.00 50,000.00 50,000.00
floor standing 42U 19" equipment rack with glass door,
removable side panel, vent panels with ventilation
equipments including fan and thermostat,heavy duty,
castor wheels and all necessary accessories type
15.11 Legrand or approved equivalent.. No 1.00 20,000.00 20,000.00
0.00
Sound System 0.00

Confrence room ,Cafteria and Intertainment deck 0.00


15.12 Ceiling Recessed speakers with power rating of 5W'
RMS, minimum shall be provided with the necessary
accessories, Speaker back box shall be recessed type
BOSCH BCS-CS5E or approved equivalent. No 16.00 7,500.00 120,000.00
15.13 All-in-one solution for background music and paging
DVD/CD player for video and audio
• Supports MP3, JPEG, and multi-format video
outputs
• FM/AM tuner with 10 presets and digital control
• Dual zone 120W mixer amplifier with volume
control per
zone to be mounted in a 19" rack. For cafteria and
intertainment deck.Type BOSCH PLN-2AIO120 or
approved equivalent.
No. 2.00 95,000.00 190,000.00
15.14 12U 19" equipment rack with glass door, removable
side panel, vent panels with ventilation equipments
including fan and thermostat,heavy duty, castor
wheels and all necessary accessories type Legrand or
approved equivalent.. No 3.00 8,000.00 24,000.00

Sound and Projection System


Confernce room And Hall

Page 46 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

15.15 Full range line array Laud speaker system type BOSCH
LBC-3200. or approved equivallent , with all necessay
connecting and mounting acessories No 6.00 35,000.00 210,000.00
15.16 240 W power Amplifier to be mounted in a 19" rack.
For confrence room Bosch PLE 1P 240 EU No. 1.00 44,250.00 44,250.00
15.17 All-in-one solution for background music and paging
DVD/CD player for video and audio
• Supports MP3, JPEG, and multi-format video
outputs
• FM/AM tuner with 10 presets and digital control
• Dual zone 120W mixer amplifier with volume
control per
zone to be mounted in a 19" rack. For confrence Type
BOSCH PLN-2AIO120 or approved equivalent. for
multipurpose hall.
No. 1.00 95,000.00 95,000.00
15.18 Digital Acoustic Feedback suppressor LBB1968/00 or
approved Equivallent. No 1.00 46,500.00 46,500.00
15.19 Configuration/diagnostic ,voting, interprtation
,camera control & system startup software No. 1.00 245,000.00 245,000.00
15.20 Confrence system Software's, documentation,
instruction of owner's staff,power
supplies/transformers. LS 1.00 50,000.00 50,000.00
15.21 Desk top microphone holder with telescopic height
and tilt adjustment type BOSCH LBB3310/00 or
approved equivalent. No 4.00 2,500.00 10,000.00
15.22 Floor standing microphone holder type BOSCH
LBB1221/01 or approved equivalent. No 1.00 2,500.00 2,500.00
15.23 24U 19" equipment rack with glass door, removable
side panel, vent panels with ventilation equipments
including fan and thermostat,heavy duty, castor
wheels and all necessary accessories type Legrand or
approved equivalent.. No 1.00 16,200.00 16,200.00
15.24 12U 19" equipment rack with glass door, removable
side panel, vent panels with ventilation equipments
including fan and thermostat,heavy duty, castor
wheels and all necessary accessories type Legrand or
approved equivalent.for confrence room. No 1.00 8,500.00 8,500.00
15.25 BARCO SLM Performer series R 10 light output of
10000 Anis Lumen projector , Resolution 1280x1024
(native) 1600x1200 (max) or equivalent and approved
with ceiling mount bar and all other necessary
accessories. No 1.00 ### 1,250,000.00
15.26 5m (width) x4.5m height electrically operated top roller
type projection screen with in-line tube motor, single
phase 220/240V 50Hz of matt white, complete with
mounting accessories and control system and
manufactured by Harkness Hall or approved
equivalent. No 1.00 475,000.00 475,000.00
15.27 Ditto but for 3m(width )and 2.25m(hight ) projection
scereen for confrence room. No 1.00 95,000.00 95,000.00
15.28 Media presentation switcher MPS 112 No 1.00 72,350.00 72,350.00
15.29 Document camera type ELMO model MO-1 or
approved equivalent. No 1.00 56,000.00 56,000.00
15.30 Wireless Receiver type Bosch LBB 9112/00 with
housing Bosch LBB 9110/00 and mounting bracket
Bosch LBB 9115/00 or approved equivalent. No 3.00 24,599.00 73,797.00
15.31 Wireless hand held Microphone/Transmitter type
Bosch LBB 9121/00 or approved equivalent. No 3.00 18,200.00 54,600.00
15.32 Wirless Tie clip Microphone /transmitter all complete
No 4.00 18,200.00 72,800.00

Page 47 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

15.33 Digital discussion system central control unit with Full


discussion control , Highly flexible and customisable
system supporting up to 150 units Typr BOSCH DCN
CCU or approved Equivallent. No 2.00 245,000.00 490,000.00
15.34 Digital Confrence discussion system table top deligate

unit with voting and simultanous interpretation. No 15.00 46,000.00 690,000.00


15.35 Digital Confrence discussion system table top Chirman

unit with voting and simultanous interpretation. No 2.00 48,500.00 97,000.00


15.36 Profesional Audio Recording system type TASCAM
SSR 100 No 2.00 85,000.00 170,000.00
15.37 Sound and projection system cabling and
termination . In accordance with manufacturer's
instructions, supplied, installed, connected, color
coded including label, tested and commissioned,
complete, all as specified and / or as shown on the
drawings. Price should include junction box and other
necessary accessories. Ls 1.00 50,000.00 50,000.00

16.CCTV SYSTEM
IP based Closed circuit television equipment, supplied,
installed,connected, tested and commissioned
including CAT6 UTP cables,complete all as specified
(or equivalent).Factory test report,2 years guarantee
factory faults

CCTV POINTS
16.1 IP CCTV points in thermoplastic conduit of minimum
diameter 21mm fed by CAT6 UTP cable as shown on
drawings, including junction boxes with covers,
No 64.00 1,458.00 93,312.00
16.2 IP CCTV 5MP 360 deg.Fisheye Mobile vendal
resistance digital PTZ/Bi directional Audio ,Digital
wide dynamic range Motion detection Audio detection
M12 & RJ-45 connector. Type SAMSUNG SNF-8010VM
or approved equivallent.
No 64.00 54,850.00 3,510,400.00
16.3 Approved type 32" LCD high resolution color
monitor,desplay 16/9 .maximum resolution:1680x1050
No. 4.00 48,200.00 192,800.00
16.4 Purpose made control consol for seven 32"monitors,
VCR, multiplexer,controller and keyboard
No. 1.00 50,000.00 50,000.00
16.6 Approved type alarming switcher 220Vac/ 50Hz No 1.00 12,000.00 12,000.00
16.1 Fully programmable keyboard controller with touch
screen LCD as specified or approved equivalent.
No. 2.00 43,150.00 86,300.00
16.11 CCTV Management Software licence for 64 cameras,
documentation, instruction of owner's staff, power
supplies/transformers. LS 1.00 335,000.00 335,000.00

16.12 CCTV IP Network video recorder NVR 4/16 cameras,


Pentaplex: simultaneous live, record,
playback,extraction and remote access Video
compression format: H264 , Number of frames
recorded: Up to 25 frames per second for 16 cameras in
D1 resolution Memory: 2 x 2 TB internal hard disks, i.e.
a total of 4TB and built-in DVD writer: and 19" rack
mountable with all necessary acessories to make the
system complete.
No 4.00 450,000.00 1,800,000.00

Page 48 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

16.13 CCTV system with above mentioned equipments


including system connectors,line and head end video
amplifiers, digital control system , cabinet of heavy
duty and free standing for all electronic equipments
with complete analysis made on cable losses (both
signal and power) & signal level in dB at out camera
and monitor units ,with latest technology of each
equipments, shop drawing with complete analysis and
all the necessary accessories to be submitted prior to
purchase and installtion. see the drawing for the lay
out

ls 1.00 250,000.00 250,000.00

17.FIRE ALARM SYSTEM


Cabling
-As per IEC 331,IEC 332-1,IEC 332-3,IEC 1034,IEC 754-1
-With copper conductor
-Fire resistant and flame retardant
-Colour coded and suitable for addressable system
-Consisting of all the necessary accessories

Smoke / heat detector ,Manual call points , short


circuit isolators , alarm and visual indicating points
fed through fire resistant cable of 2-core 2.5sq.mm
inside PVC conduit of 20mm diameter including all
17.1 necessary accessories. No. 479.00 1,850.00 886,150.00

Fire alarm control pannel


Intelligent fire alarm equipment, supplied, installed,
connected, tested and commissioned including fire
rated cables, conduits and all necessary accessories,
complete as manufatured by Notifier or approved
equivalent and/or shown on drawings.'Factory test
report,2 years guarantee factory faults

17.2 Intelligent digital addressable fire control and


indicating panel, type Notifier NFS2-3030 one up to
ten loop control pannel , or approved eqivqlent
including Notification Appliance Circuit
Modules,Control Relay Module , auxilary contact and
under mentioned specification

-Input power 220VAC, 50 Hz


-Capable of networked connection
-Programmable internal hard ware and output circuits
-Programmable soft ware zones
-Accessories for out put connection for telephone circuit
-Sealed battery capable of supply to all equipments for at least 72Hr
-Intelligent signaling line circuit
-PA system interface
-water sprincler system interface
-MOD BUS support
-Visual and audiable trouble alarm by zone
-Manual acknowlage function
-Minimum of 20 zones digital
-LCD display (80 characters)
-Program keypad
-LED indicators
-13 relay outputs
-8loops
-Compatible intelligent devices
with all necessary accessories as BSNE 54
standards to make the system complete. No. 1.00 480,000.00 480,000.00

Intelligent ionization type photoelectric smoke sensors


with all necessary mounting accessories, for both
17.3 surface / flush mounting No. 363.00 3,500.00 1,270,500.00

Page 49 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

Intelligent heat sensor type with all necessary


mounting accessories, for both surface /
17.4 flush.mounting No. 15.00 3,500.00 52,500.00
Annunciator fire alarm visula indicator with all
necessary mounting accessories, for surface/ flush or
17.5 wall mounting No. 35.00 2,800.00 98,000.00
Fire alarm sounder (siren) with sound presure of 110
dB at 1 meter (Red) with all necessary mounting
17.6 accessories, No. 35.00 280.00 9,800.00
Addressable manual pull switch station with all
necessary mounting accessories, flush mounting,for
17.7 surface/ flush or wall mounting . No. 32.00 3,100.00 99,200.00
17.8 Short circuit isolators to be placed after every 18 detect No 26.00 1,900.00 49,400.00

18. Master AC distrubution pannel with


AC Power Line Surge Protector and Filter
for PA,CCTV ,Fire alarm systems

18.10 The cabinet containing active electronic equipment


shall be equipped with an AC Surge Protector and Filter.
The Protector and Filter shall be housed in one single
cabinet enclosure. The Protector and Filter shall
provide instantaneous regulation of the AC input
voltage and isolate and filter any noise present on the
AC input line.
-Input Voltage range 220V AC
-Power capacity minimum of 4KW
-Voltage output regulation
-Main Circuit breaker 25 AMP
-6 AC outlets grounded types, minimum
with defined and standardized response time,surge
suppression and noise suppression No 1.00 12,000.00 12,000.00

19. Passenger Lift


19.1 Supply and install Passenger Lift as per the specification

Technical Specifications
Standards
ISO 7465:2001,EN-81,BS ,ANSI,JIS,ISO 9001,ES
3158:2006,ES 3159:2006 , latest editions of BS/EN or ES
and others quality certificate for design, Manufacturing
installation and commissioning lifts and lift parts.

-Electromagnetic compatibility
- Electromagnetic immunity
-Electrical Safety
- Electronic equipment for use in power facilities:

Mechanical property and Finishing Material


Function :- Passenger Lift
Rated load : - 1050kg, 13person
Rated speed :- 1.6m/sec
Number of stops:-17 in one line
Floor - 3B+G+M+12
Cabin door type:- Automatic center opening
Landing door type:- Automatic single door center opening
No entrance :- one(1) @ 0 degree
Floor - Vinyl composition tile/wear resistant rubber
Wall - Stainless steel
Interior face of doors - Stainless steel
Ceilings - Stainless steel panels/diffuser gird
Handrail -stainless steel, two sides
Mirror -Silver color, rear panel
Frame- Stainless steel
Exterior face of door - Stainless steel
Drive system and Elevator operation

Page 50 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

-Gearless machine
- Duplex full Collective Selective control
-Electric traction type
-VVVF with encoder
Special operation and facilities
- Smoke Detectors
- Alarm buzzer
- Chime gong to sound present audioable indication control
- Toggle switch
- call registered light
- Inter phone to communicate with machine room
- Over load indicator both audible and visual indicators
Car and Landing operation panel
- Car display for position and direction
- Digital car position and direction control
-Digital landing position & direction indicator on
all floors
-Vandal proof Wait/stop push button
-Car display for position and direction
Control and safety features
-Dynamic braking for traction machine in event of power
failure
Power supply- 380volts AC 50Hz 3phase
Disable - Add Braille tactile to all emergency buttons
Lighting Supply
- 220v, 50Hz, 1ph
- Indirect light in diffuser grid
Ventilation
-Car ventilation with fan built in the ceiling
-Temperature control Thermostat
Rescue device
-Automatic rescue device/ back up(Emergency battry drive)
when power fails
- All power outputs are electronically protected
against short circuit

- Earth leak detection for traction machine during


emergency operation(short circuit, overload, loss of
connection of a phase to the motor, phase
imbalance,thermal protection, overspending, turning
blockage) Performs analysis of optimum motor turning
direction (minimum battery consumption during
emergency operation) Conforms to EN81 regulation No 2.00 ### 6,000,000.00

19.2 Ditto but for Passaanger Lift with


Rated load : - 1050kg, 13person
Rated speed :- 1.6m/sec
Number of stops:-18in one line
Floor - 3B+G+M+13
Drive system and Elevator operation
-Gearless machine
- Simlex down Collective Selective control
-Electric traction type
-VVVF with encoder No 1.00 ### 3,100,000.00
19.3 Ditto but for Passaanger Lift with
Rated load : - 1050kg, 13person
Rated speed :- 1.6m/sec
Number of stops:-18 in one line
Floor - 3B+G+M+13
Cabin door type:- Automatic center opening
Landing door type:- Automatic single door center opening
No entrance :- two (2) @ 90degree
Drive system and Elevator operation
-Gearless machine
- Simlex down Collective Selective control
-Electric traction type

Page 51 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

-VVVF with encoder No 1.00 ### 3,500,000.00

Shaft Information

-Shall take and consider approprate standards


for the shaft,cabin,cabin doors,machine room size
and other parameters before manufacturing and
prepare working drawing referring to the
archtectrural and structural for submission
with the technical specification.

Submit for approval complete upto date lift


specification of the above items including guide
rails, reinforcement bar buffer,duty ,prewiring ,
conduiting/ trunking and other required and
necessary specification with working drawing
referring to archtectural and structural from at
least 3 lift suppliers having a minimum of 5 years
or equivalent grantee period in lift manufacturing
,design, installation and maintenance.

2 SITE ELECTRICAL INSTALLTIONS WORK

Supply and install :-


1. MV/LV Transformer
(Supplied by EEPCo or Nominated Sub
Contractor)

Utility connection compact sub station with


transformer of 1250KVA ,gas insulated RMU 2+1,with
internal breaker ,CT and VT for KWH,KVAR low
voltage side switch gears and all medium, low and
hightension cable connection accessories and all the
necessary accessories as perEEPCO regulation and the
1 low voltage side consisting of
1Pc Main ACB of 2000A, 3ph Icu=35kA
1Pc of surge arrestor of 40KA
with bus bar of 2500A ,approved type bus supprorting
accessories and ample reserve space No 1.00 ### 2,500,000.00

2 Standby Diesel Generator Set


( supplied by client )
2.1 a. Supply and install out door generator with foundation
as per the manufacturer recommdation shock absorving
mounting rails and the following specifications:-
Type water cooled turbo engine
Altitude Avg =2400meters(addis abab)
Frequency 50Hz
Stand by power 800KVA
Control panel comprises the following:-
- 3 Ammeter
-Voltmeter/selector switch
-Hour run counter
-Alarm modul
-Water temperature gauge
- Molded case circuit breaker with access and bus way
connection
-Frequency meter
-Battery condition indicator
-Emergency stop button
-Lubrication oil pressure gauge
- Protection fuse
-12-24V electric starting system including heavy duty
dry charged battery pack
-Sheet steel constructed frame
-Antivibration pad between engine /alternator and base

Page 52 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

frame and ground


-Painting to high industrial standards
-Operation and maintenance manuals ,spare parts
for one year catalogs circuit diagram and test report
-Sound Canopy with all the necessary Exhaust and inlet
ventilation system extended upto the area which doesn't
affect the surrounding area with noise level of 80db@1meter
(silencer/air inlet and out let sound attenuators and sound
absorving wall lining) in consaltion with the engineer
-Base mounted daily fuel tank complete with essential
accessories comprising filiter,breather feed and return
lines dial type content gauge and complete accessories

b.Custom designed fuel tank capacity of 5000 liters


with pumps and accessories comprising filiter,breather
feed and return lines dial type content gauge and
complete accessories and connections with detail
drawings submitted before installation in consulation
with the engineer.
Factory test report,2 years guarantee for factory faults
C.-2000A automatic transfer switch in floor standing
metal inclosure and locable door ,ip 54 ,cable
connection accessories ,Automatic mains and generator
sensing unit ,digital master control and all the
necessary accessories . No 1.00 ### 4,000,000.00

3. Underground Feeder Power cables


3.1 Multicore power cable 0.6/1KV with copper
conductors, PVC insulated PVC sheathed, color coded,
( measured elsewhere) connected and tested, all as
specified and as shown on drawings(Tentative).

3.2 4(3x240/120) sqmm from Transformer & Generator to


ATS,from ATS to MDB ml 30.00 14,207.40 426,222.00

4.External light pole


4.1
hot deep galvanized steel pole dia. 120 mm at base and
dia. 60mm at top with arm lenght 1500mm ,3mm thick
through out its length 6000mm above groundlevel to
be fixed on 800 x800 x 600 mm (D x L x W) concrete
pad with plates of 8mm thick & 4 ancor bolts
diameter 27mm and 700mm long cable entry through
PP dia. 50mm ,fuse box and fuse of 6A as per the
detail drawing.(Fumagali ,AKILLE 5000/BEPPE 500
P60.427.000 No 12.00 7,000.00 84,000.00

External light fixture


Fumagali BEPPE 500 LED Version with 9x10w
Gx53LED with all necessary axcessories. For pole
4.2 mounting. No 12.00 5,000.00 60,000.00
Fumagali BEPPE 500 LED Version with 9x10w
Gx53LED with all necessary axcessories. For gate post
P60.115.D9L mounting. No 2.00 4,000.00 8,000.00

TOTAL CARRIED TO SUMMERY 70,291,321.31

1.MECHANICAL INSTALLATION
1 Meeting Room
1.1 Packaged Air Cooled Scroll compressor Water
Chillers Integrated with Hydronic Module /Outdoor
units/

Page 53 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

Supply, Install and setting to work including all


required field wiring in rigid metal conduit from
Chiller panel to local isolators, condenser anti
corrosion coatings, spring vibration isolators, electrical
isolators temperature controllers, testing and
commissioning etc. as per equipment schedule.

Refrigerant : R-407C
Features:
-Refrigerant shall be R-410 to ensures similar
performances to those achieved with R-22 and offers
an economical solution to environmental protec-tion
problems.
-The unit shall incorporates two axial fans with
horizontal air dis-charge, exceptionally low-noise
operation and Compact unit dimensions to facilitate
installation of these units in restricted spaces.

Control:
PRO-DIALOG Plus control shall be provided as an
advanced numeric control sys-tem that combines
complex intelligence with great operat-ing simplicity.
PRO-DIALOG Plus shall constantly monitors all
machine parameters and safety devices, and precisely
man-ages the operation of compressor and fans for
optimum energy efficiency. It shall also controls the
operation of the water pump.

Hydronic Module & Kits:


The hydronic module shall be factory-installed to
eliminates the need to install the necessary components
on site, mak-ing the unit more compact and easy to
install.
Water fill system shall have:
-Spherical check valve
- Pressure reduction valve
- Safety valve
Hydronic kit Accessories:
- Flow switch
- Suction pressure gauge
- Expansion tank
- Spherical shutoff valve
- Filter- Pressure pump
- Spherical control valve
- Discharge pressure gauge
- Automatic purge.

1.1.1 AIR COOLED CHILLERS/ HYDRONIC MODULE /Europe manufactured/

Supply, fix,test and commission air cooled centrifugal


chillers as per the manufacturer's specification &
instruction, including vaves, short length piping &
fittings, instrumentation devices & supports all as
specified in the standared manufacturer' specification
and/or shown on the drawings.

Price shall include dual pump / one-stand-by/ & the


pump head & flow rate shall be determined by the
contractor based on the selected hydronic cassette
fancoil units flow & head requirment, final chiller
location & final pipes layout. Price shall also include
the following items as detailed on the drawings and
manufacturer's manual.
- Strainers /1pcs/
- Pressure gauges /2pcs/
- Flexible pipe connectors /2pcs/

Page 54 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

- Plug-Tee for cleaning /2pcs/


- Thermometer /2pcs/
- Flow switch /1pc/
- Isolating valves /2pc/
- Gate valve /2pc/
- Double regulating/balancing/ valve /1pc/
- Air relief valves /2pc/

Air-cooled chiller with integrated hydronic module


(ACWC-1)
Net nominal cooling capacity =67kw
Type:Carrier or equivalent
Model: 30RBS-070
Nominal power supply=400-3-50
Estimated total power consumption =31.2kw
Operating weight =522kg
Altitude = 2355m.a.s.l No 1.00 ### 2,266,291.00

1.2 Air Handling Unit


Supply and install out door air handling unit (AHU)
whether proof type as shown on the drawing and as
per the following specification. Type -39G GALAXY
carrier AHU for textile laboratories as shown
complete with casing with plastic cover,mixing box
louver, damper and screen, filters , fan, motor and
drive chilled water cooling coil , variable frequency
drive for fan motors and completely prewired
control panel

Purpose- supply and return


Cooling mater inlet/outlet temperature - 7 / 12ºC
Supply/return air quantity = 4360l/s
Altitude = 2355m.a.s.l
- Roof crab shall be provided chillers.
- The supply static pressure shall be verified
and determined by the contractor
- AHU shall be acaustically lined NO 1.00 ### 1,591,118.00

1.3 RETURN and SUPPLY DUCT WORKS AND


ACCESSORIES
1.3.1 Supply,fix.test and commission galvanized steel air
supply and exhaust ducts as where shown on the
drawing. All duct construction & installation shall
follow the technical specification of this
project,standardes and recommendations
conditioning given on SMACNA (Sheet Metal and
Air Contractors National Association,INC) and
EBCS11.

Price shall also include all the necessary duct


reinforcement, fixing clamps to slabs,walls, vanes,
flange,corner,gasket etc and all the necessary
fittings and civil assistance works.
Galvanization coating should be 0.2mm thick.

Duct longer size(mm) Sheet metal thickness(mm)


Up to 600 mm 0.6 mm
600 to 800 mm 0.8 mm
800 to 1000 mm 0.9 mm
1000 to 1200 mm 1.0 mm
1200 to 1500 mm 1.3 mm
1500 to 2100 mm 1.5 mm
400x375mm ml 36.00 1,100.00 39,600.00
450x400 mm ml 14.00 1,200.00 16,800.00
675x400mm ml 11.00 1,520.00 16,720.00
925x400mm ml 4.00 1,750.00 7,000.00

Page 55 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

1200x400mm ml 5.00 2,750.00 13,750.00


1750x400mm ml 4.00 5,450.00 21,800.00
1750x450mm ml 14.00 5,550.00 77,700.00
1225x800mm ml 48.00 5,950.00 285,600.00

1.3.2 Ditto to item number 3.2.1 above but for


conditioned/cooled/ air supply ducts
400x350mm ml 26.00 1,100.00 28,600.00
450x375mm ml 11.00 1,950.00 21,450.00
625x400mm ml 19.00 1,480.00 28,120.00
850x400mm ml 7.00 1,620.00 11,340.00
1100x400mm ml 14.00 2,250.00 31,500.00
1600x650mm ml 7.00 6,100.00 42,700.00
1450x700mm ml 50.00 6,450.00 322,500.00

1.4 Return and Supply Air Terminal Units

Supply, fix, test and commission Supply and Return


Air Linear Ceiling Diffusers / Ceiling Mounted/.
From high
quality extruded aluminium profile Frame and
standard(20mm) blade spacing. Price shall include
foam gasket seal around the back of the frame and
flexible duct connectors as required.

1.4.1 Return Air Linear Diffuser


RALD-2
Capacity =210 liter/sec
Type : AIR MASTER or Equivalent
Slot width : 25mm
Number of slots : 4
Length: 1000mm
Model: ARLD-25

Colour: As per the Architect's preference No 22.00 4,590.00 100,980.00

Page 56 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

1.4.2 Supply Air Linear Diffuser


SALD-2
Capacity =195 liter/sec
Type : AIR MASTER or Equivalent
Slot width : 19mm
Number of slots : 6
Length: 1000mm
Model: ASMLD-19
Colour: As per the Architect's preference
No 24.00 6,610.00 158,640.00

1.5 Dampers and accessories :

All dampers and accessories shall be manufactured as


per recognized codes, standards & and full fill the
requirements specified in the technical specification.

1.5.1 Volume Dampers


Supply, fix, test and commission volume dampers
of approved quality as where shown on the drawings.
Price shall include all the necessary accessories and
connecting pieces.
Model: AIR MASTER or Equivalent
For duct Size: 400 x 300 mmxmm/ VD No 1.00 4,985.00 4,985.00
400 x 375 mmxmm/ VD No 9.00 5,040.00 45,360.00
450 x 400 mmxmm/ VD No 2.00 5,940.00 11,880.00
1000 x 975 mmxmm/ VD No 1.00 13,620.00 13,620.00

1.5.2 Fire Damper


Supply fix, test and commission fire dampers of
approved quality as specified and/or shown on the
drawings. Price shall include all the necessary
accessories and connecting pieces.
For duct Size: 1000 x 975 mmxmm/ FD No 2.00 22,151.00 44,302.00

1.5.3 Sound Attenuator


Supply fix, test and commission sound attenuator of
approved quality as specified and/or shown on the
drawings. Price shall include all the necessary
accessories and connecting pieces.

For duct Size: 1000 x 975 mmxmm/SA No 2.00 24,340.00 48,680.00

1.6 Exhaust Air Fans


Supply, fix,test and commission DYNAIR or Equivalent
fans as shown on the drawing, complete
with all accessories including control systems for
alternate operation of the flow fans.
Exhaust Air Fan (EF-1)
Model: CC-352
Manufacturer: Dynair or Equivalent
Discharge = 925 LPS
Head = 150Pa
Powe input = 0.55KW
Altitude = 2355m.a.s.l No 1.00 557,350.00 557,350.00

1.7 Fresh Air Louver


Supply, fix, test and commission AIR MASTER or
Equivalent Fresh Air Louver of approved quality as
shown on the drawings. Price shall include all the
necessary accessories and connecting pieces.
Manufacturer: AIR MASTER or Equivalent
Size: 550 x 450 mmxmm No 1.00 25,679.00 25,679.00

1.8 Flexible Duct

Page 57 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

Supply, fix, test and commission Xpelair or Equivalent


Flexible Duct of approved quality.
Price shall include all the necessary accessories and
connecting pieces.
Size: Dia 425mm, L=3m Ps 17.00 3,100.00 52,700.00

2 Cafeteria
2.1 Packaged Air Cooled Scroll compressor Water
Chillers Integrated with Hydronic Module /Outdoor
units/
Supply, Install and setting to work including all
required field wiring in rigid metal conduit from
Chiller panel to local isolators, condenser anti
corrosion coatings, spring vibration isolators, electrical
isolators temperature controllers, testing and
commissioning etc. as per equipment schedule.

Refrigerant : R-407C
Features:
-Refrigerant shall be R-410 to ensures similar
performances to those achieved with R-22 and offers
an economical solution to environmental protec-tion
problems.
-The unit shall incorporates two axial fans with
horizontal air dis-charge, exceptionally low-noise
operation and Compact unit dimensions to facilitate
installation of these units in restricted spaces.

Control:
PRO-DIALOG Plus control shall be provided as an
advanced numeric control sys-tem that combines
complex intelligence with great operat-ing simplicity.
PRO-DIALOG Plus shall constantly monitors all
machine parameters and safety devices, and precisely
man-ages the operation of compressor and fans for
optimum energy efficiency. It shall also controls the
operation of the water pump.

Hydronic Module & Kits:


The hydronic module shall be factory-installed to
eliminates the need to install the necessary components
on site, mak-ing the unit more compact and easy to
install.
Water fill system shall have:
-Spherical check valve
- Pressure reduction valve
- Safety valve
Hydronic kit Accessories:
- Flow switch
- Suction pressure gauge
- Expansion tank
- Spherical shutoff valve
- Filter- Pressure pump
- Spherical control valve
- Discharge pressure gauge
- Automatic purge.

2.1.1 AIR COOLED CHILLERS/ HYDRONIC MODULE /Europe manufactured/

Supply, fix,test and commission air cooled centrifugal


chillers as per the manufacturer's specification &
instruction, including vaves, short length piping &
fittings, instrumentation devices & supports all as
specified in the standared manufacturer' specification
and/or shown on the drawings.

Page 58 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

Price shall include dual pump / one-stand-by/ & the


pump head & flow rate shall be determined by the
contractor based on the selected hydronic cassette
fancoil units flow & head requirment, final chiller
location & final pipes layout. Price shall also include
the following items as detailed on the drawings and
manufacturer's manual.
- Strainers /1pcs/
- Pressure gauges /2pcs/
- Flexible pipe connectors /2pcs/
- Plug-Tee for cleaning /2pcs/
- Thermometer /2pcs/
- Flow switch /1pc/
- Isolating valves /2pc/
- Gate valve /2pc/
- Double regulating/balancing/ valve /1pc/
- Air relief valves /2pc/

Air-cooled chiller with integrated hydronic module


(ACWC-1)
Net nominal cooling capacity =79kw
Type:Carrier or equivalent
Model: 30RBS-080
Nominal power supply=400-3-50
Estimated total power consumption =35.8kw
Operating weight =537kg
Altitude = 2355m.a.s.l No 1.00 ### 2,672,194.00

2.2 Air Handling Unit


Supply and install out door air handling unit (AHU)
whether proof type as shown on the drawing and as
per the following specification. Type -39G GALAXY
carrier AHU for textile laboratories as shown
complete with casing with plastic cover,mixing box
louver, damper and screen, filters , fan, motor and
drive chilled water cooling coil , variable frequency
drive for fan motors and completely prewired
control panel

Purpose- supply and return


Cooling mater inlet/outlet temperature - 7 / 12ºC
Supply/return air quantity = 5730l/s
Altitude = 2355m.a.s.l
- Roof crab shall be provided chillers.
- The supply static pressure shall be verified
and determined by the contractor
- AHU shall be acaustically lined NO 1.00 ### 2,091,080.00

2.3 RETURN and SUPPLY DUCT WORKS AND


ACCESSORIES
2.3.1 Supply,fix.test and commission galvanized steel air
supply and exhaust ducts as where shown on the
drawing. All duct construction & installation shall
follow the technical specification of this
project,standardes and recommendations
conditioning given on SMACNA (Sheet Metal and
Air Contractors National Association,INC) and
EBCS11.

Price shall also include all the necessary duct


reinforcement, fixing clamps to slabs,walls, vanes,
flange,corner,gasket etc and all the necessary
fittings and civil assistance works.
Galvanization coating should be 0.2mm thick.

Duct longer size(mm) Sheet metal thickness(mm)

Page 59 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

Up to 600 mm 0.6 mm
600 to 800 mm 0.8 mm
800 to 1000 mm 0.9 mm
1000 to 1200 mm 1.0 mm
1200 to 1500 mm 1.3 mm
1500 to 2100 mm 1.5 mm
500x200mm ml 32.00 990.00 31,680.00
500x325 mm ml 10.00 1,200.00 12,000.00
750x350mm ml 36.00 1,820.00 65,520.00
850x400mm ml 6.00 1,950.00 11,700.00
1075x400mm ml 4.00 2,410.00 9,640.00
1575x450mm ml 44.00 5,210.00 229,240.00
1575x450mm ml 30.00 5,350.00 160,500.00

2.3.2 Ditto to item number 2.3.1 above but for


conditioned/cooled/ air supply ducts
300x125mm ml 31.00 765.00 23,715.00
400x200mm ml 19.00 900.00 17,100.00
400x250mm ml 12.00 950.00 11,400.00
500x325mm ml 12.00 1,200.00 14,400.00
675x350mm ml 12.00 1,480.00 17,760.00
800x350mm ml 7.00 1,520.00 10,640.00
900x350mm ml 7.00 1,950.00 13,650.00
1075x400mm ml 4.00 2,410.00 9,640.00
1200x550mm ml 44.00 3,460.00 152,240.00
1350x500mm ml 7.00 5,020.00 35,140.00

2.4 Return and Supply Air Terminal Units


Supply, fix, test and commission Supply and Return
Air Linear Ceiling Diffusers / Ceiling Mounted/.
From high
quality extruded aluminium profile Frame and
standard(20mm) blade spacing. Price shall include
foam gasket seal around the back of the frame and
flexible duct connectors as required.

2.4.1 Return Air Linear Diffuser


RALD-1
Capacity =345liter/sec
Type : AIR MASTER or Equivalent
Slot width : 25mm
Number of slots : 8
Length: 1000mm
Model: ARLD-25

Colour: As per the Architect's preference No 16.00 4,590.00 73,440.00

2.4.2 Supply Air Linear Diffuser


SALD-1
Capacity =275 liter/sec
Type : AIR MASTER or Equivalent
Slot width : 19mm
Number of slots : 8
Length: 1000mm
Model: ASMLD-19
Colour: As per the Architect's preference
No 23.00 6,610.00 152,030.00

2.5 Dampers and accessories :

All dampers and accessories shall be manufactured as


per recognized codes, standards & and full fill the
requirements specified in the technical specification.

2.5.1 Volume Dampers

Page 60 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

Supply, fix, test and commission volume dampers


of approved quality as where shown on the drawings.
Price shall include all the necessary accessories and
connecting pieces.
Model: AIR MASTER or Equivalent
For duct Size: 500 x 200 mmxmm/ VD No 8.00 4,985.00 39,880.00
450 x 400 mmxmm/ VD No 2.00 5,940.00 11,880.00
1100 x 600 mmxmm/ VD No 1.00 12,620.00 12,620.00

2.5.2 Fire Damper


Supply fix, test and commission fire dampers of
approved quality as specified and/or shown on the
drawings. Price shall include all the necessary
accessories and connecting pieces.
For duct Size: 1100 x 600 mmxmm/ FD No 1.00 21,151.00 21,151.00
1000 x 650 mmxmm/ FD No 1.00 21,151.00 21,151.00

2.5.3 Sound Attenuator


Supply fix, test and commission sound attenuator of
approved quality as specified and/or shown on the
drawings. Price shall include all the necessary
accessories and connecting pieces.

For duct Size: 1100 x 600 mmxmm/SA No 1.00 23,340.00 23,340.00


1000 x 650 mmxmm/SA No 1.00 23,340.00 23,340.00

2.6 Exhaust Air Fans


Supply, fix,test and commission DYNAIR or Equivalent
fans as shown on the drawing, complete
with all accessories including control systems for
alternate operation of the flow fans.
Exhaust Air Fan (EF-1)
Model: CC-352
Manufacturer: Dynair or Equivalent
Discharge = 1105LPS
Head = 150Pa
Powe input = 0.55KW
Altitude = 2355m.a.s.l No 1.00 665,810.00 665,810.00

2.7 Fresh Air Louver


Supply, fix, test and commission AIR MASTER or
Equivalent Fresh Air Louver of approved quality as
shown on the drawings. Price shall include all the
necessary accessories and connecting pieces.
Manufacturer: AIR MASTER or Equivalent
Size: 600 x 500 mmxmm No 1.00 25,679.00 25,679.00

2.8 Flexible Duct


Supply, fix, test and commission Xpelair or Equivalent
Flexible Duct of approved quality.
Price shall include all the necessary accessories and
connecting pieces.
Size: Dia 275mm, L=3m Ps 2.00 1,491.00 2,982.00
375mm, L=3m Ps 6.00 2,450.00 14,700.00
425mm, L=3m Ps 6.00 3,100.00 18,600.00

3 OFFICES HVAC SYSTEM


3.1 Packaged Air Cooled Scroll compressor Water
Chillers Integrated with Hydronic Module /Outdoor
units/

Page 61 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

Supply, Install and setting to work including all


required field wiring in rigid metal conduit from
Chiller panel to local isolators, condenser anti
corrosion coatings, spring vibration isolators, electrical
isolators temperature controllers, testing and
commissioning etc. as per equipment schedule

Refrigerant : R-407C
Features:
-Refrigerant shall be R-410 to ensures similar
performances to those achieved with R-22 and offers
an economical solution to environmental protec-tion
problems.
-The unit shall incorporates two axial fans with
horizontal air dis-charge, exceptionally low-noise
operation and Compact unit dimensions to facilitate
installation of these units in restricted spaces.

Control:
PRO-DIALOG Plus control shall be provided as an
advanced numeric control sys-tem that combines
complex intelligence with great operat-ing simplicity.
PRO-DIALOG Plus shall constantly monitors all
machine parameters and safety devices, and precisely
man-ages the operation of compressor and fans for
optimum energy efficiency. It shall also controls the
operation of the water pump.

Hydronic Module & Kits:


The hydronic module shall be factory-installed to
eliminates the need to install the necessary components
on site, mak-ing the unit more compact and easy to
install.
Water fill system shall have:
-Spherical check valve
- Pressure reduction valve
- Safety valve
Hydronic kit Accessories:
- Flow switch
- Suction pressure gauge
- Expansion tank
- Spherical shutoff valve
- Filter- Pressure pump
- Spherical control valve
- Discharge pressure gauge
- Automatic purge.

3.1.1 AIR COOLED CHILLERS/ HYDRONIC MODULE /Europe manufactured/

Supply, fix,test and commission air cooled centrifugal


chillers as per the manufacturer's specification &
instruction, including vaves, short length piping &
fittings, instrumentation devices & supports all as
specified in the standared manufacturer' specification
and/or shown on the drawings.

Price shall include dual pump / one-stand-by/ & the


pump head & flow rate shall be determined by the
contractor based on the selected hydronic cassette
fancoil units flow & head requirment, final chiller
location & final pipes layout. Price shall also include
the following items as detailed on the drawings and
manufacturer's manual.

- Strainers /1pcs/
- Pressure gauges /2pcs/
- Flexible pipe connectors /2pcs/

Page 62 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

- Plug-Tee for cleaning /2pcs/


- Thermometer /2pcs/
- Flow switch /1pc/
- Isolating valves /2pc/
- Gate valve /1pc/
- Double regulating/balancing/ valve /2pc/
- Air relief valves /1pc/

i) Air-cooled chiller with integrated hydronic


module (ACWC-3)
Net nominal cooling capacity =400kw
Type:Carrier or equivalent
Model: 30RBM-400
Nominal power supply=400-3-50
Estimated total power consumption =- kw
Altitude = 2355m.a.s.l
Operating weight =2110kg No 2.00 ### 19,176,100.00

ii) Air-cooled chiller with integrated hydronic


module (ACWC-4)
Net nominal cooling capacity =330kw
Type:Carrier or equivalent
Model: 30RBM - 333
Nominal power supply=400-3-50
Estimated total power consumption =- kw
Altitude = 2355m.a.s.l
Operating weight = 1890kg No 2.00 ### 15,717,800.00

3.2 CHILLED WATER SUPPLY PIPES AND VALVES


3.2.1 Chilled water Piping
Supply, install,test and commission ABS DURA PIPE
for chilled water supply /CSWP & CRWP/,complete
with all fittings & accessories (including isolating and
check valves on make-up water line) all as per the
technical specification & where shown on the
drawing.

a - In concealed spaces
Price shall include factory made insulation as per
the technical specification requirment with all
accessories.
i - With 32mm thick insulation
Dia.15mm ml 3060.00 540.00 1,652,400.00
Dia.20mm ml 577.00 590.00 340,430.00
Dia.25mm ml 459.00 670.00 307,530.00
Dia.32mm ml 268.00 810.00 217,080.00
Dia.50mm ml 24.00 1,230.00 29,520.00
Dia.63mm ml 34.00 1,540.00 52,360.00
Dia.75mm ml 54.00 1,620.00 87,480.00
Dia.80mm ml 5.00 1,710.00 8,550.00

b - On exposed Spaces
Price shall include factory made insulation including
aluminium cladding on exposed to weather and in
mechanical rooms,as per the technical specification
requirment with all accessories.
With 50mm thick insulation & aluminium cladding
Dia.75mm ml 10.00 1,620.00 16,200.00
Dia.80mm ml 10.00 1,710.00 17,100.00

3.2.2 Condensate Pipes


Supply and install PVC PN-10 condensate drain
pipe as shown on the drawing, complete with all
necessary accessories .
Dia. 20mm ml 1790.00 420.00 751,800.00
Dia. 25mm ml 1152.00 505.00 581,760.00

Page 63 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

Dia. 32mm ml 704.00 610.00 429,440.00


Dia. 50mm ml 94.00 953.00 89,582.00

3.3 Air Handling Unit


Supply and install out door air handling unit (AHU)
whether proof type as shown on the drawing and as
per the following specification. Type -39G GALAXY
carrier AHU for textile laboratories as shown
complete with casing with plastic cover,mixing box
louver, damper and screen, filters , fan, motor and
drive chilled water cooling coil , variable frequency
drive for fan motors and completely prewired
control panel

Purpose- supply
Cooling mater inlet/outlet temperature - 7 / 12ºC
Supply/return air quantity = 5730l/s
Altitude = 2355m.a.s.l
- The supply static pressure shall be verified
and determined by the contractor
- AHU shall be acaustically lined NO 2.00 ### 4,182,160.00

3.4 IN DOOR-HYDRONIC FAN COIL UNITS /Ceiling


mounted/
With the following requirements, the fan coil unit
shall be complete with fan, chilled water cooling
system & be contolled by a room mounted

thermostat that will control a three way chilled water

control valve, the fan coil unit shall be provided with


a galvanized drip tray and condensate shall be
piped to the nearest storm water drain pipe with a
smell trap, an isolator switch shall be provided for

each fan coil unit and shall be installed near the fan
coil /max. 0.5meter/ unit to facilitate maintenance of
each unit as required . Each fan coil unit shall be

connected to the chilled water system through a


supply and return piping line which shall be
branched from a chilled water supply and return
riser. All services connection to the fan coil units
shall be through flexible joints & strainers before
each fan coil units. Fan coil unit shall have three
speed and there shall be a possibility for speed
selection & the fan coil unit shall be selected at the
medium speed.

Ceiling mounted hydronic cassette fan coil units


a) FCU-1
Type: Carrier or equivalent
Model: 42GW-300C
Cooling capacities=2.9Kw
Power input=0.032KW
Power supply=230-1-50
Altitude = 2355m.a.s.l No 35.00 25,000.00 875,000.00

b) FCU-2
Type: Carrier or equivalent
Model: 42GW-400C
Cooling capacities=3.5Kw
Power input=0.055KW
Power supply=230-1-50
Altitude = 2355m.a.s.l No 15.00 30,413.00 456,195.00

Page 64 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

c) FCU-3
Type: Carrier or equivalent
Model: 42GW-500C
Cooling capacities=4.5Kw
Power input=0.039KW
Power supply=230-1-50
Altitude = 2355m.a.s.l No 127.00 39,103.00 4,966,081.00

d) FCU-4
Type: Carrier or equivalent
Model: 42GW-600C
Cooling capacities=5.5Kw
Power input=0.059KW
Power supply=230-1-50
Altitude = 2355m.a.s.l No 25.00 47,793.00 1,194,825.00

f) FCU-6
Type: Carrier or equivalent
Model: 42GW-701C
Cooling capacities=6.6Kw
Power input=0.09KW
Power supply=230-1-50
Altitude = 2250m.a.s.l No 9.00 57,351.00 516,159.00

3.5 Split DX-Air conditioning unit :


Supply, fix,test and commission room Air Conditioner
suitable for altitude of 2355m from sea level, including
control systems, accessories to make the system
complete. The cabinet shall be
made of prepainted sheet metal, specially suitable for
use indoors. Motors shall have internal thermal
protection, refrigerant-to-air heat exchangers shall be
manufactured from high quality copper tubing,
mechanically expanded into pretreated aluminium fins
and offer high corrosion resistance, Hermetic
reciprocating compressors shall be mounted on shock
absorbers for vibration-free operation, and include
internal mufflers and thermal protection.

Type: Carrier or Equivalent


Model: 51GSR247M-0M
Cooling capacity= 7.03kw No 11.00 29,800.00 327,800.00

3.6 SUPPLY DUCT WORKS AND ACCESSORIES


3.6.1 Supply,fix.test and commission galvanized steel air
supply duct as where shown on the drawing.
All duct construction & installation shall follow the
technical specification of this project,standardes
and recommendations conditioning given on
SMACNA (Sheet Metal and Air Contractors
National Association,INC) and EBCS11.

Price shall also include all the necessary duct


reinforcement, fixing clamps to slabs,walls, vanes,
flange,corner,gasket etc and all the necessary
fittings and civil assistance works.
Galvanization coating should be 0.2mm thick.

Duct longer size(mm) Sheet metal thickness(mm)


Up to 600 mm 0.6 mm

Page 65 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

600 to 800 mm 0.8 mm


800 to 1000 mm 0.9 mm
1000 to 1200 mm 1.0 mm
1200 to 1500 mm 1.3 mm
1500 to 2100 mm 1.5 mm
100 x100 mm ml 1956.00 400.00 782,400.00
125 x 100 mm ml 114.00 420.00 47,880.00
125 x 125 mm ml 173.00 440.00 76,120.00
150 x 125 mm ml 201.00 460.00 92,460.00
150 x 150 mm ml 64.00 480.00 30,720.00
175 x 150 mm ml 101.00 500.00 50,500.00
175 x 175 mm ml 84.00 520.00 43,680.00
200 x 175 mm ml 6.00 540.00 3,240.00
225 x 225 mm ml 65.00 765.00 49,725.00
250 x 250 mm ml 74.00 805.00 59,570.00
275 x 250 mm ml 8.00 805.00 6,440.00
400x325mm ml 4.00 990.00 3,960.00
400x425mm ml 4.00 1,200.00 4,800.00
500x375mm ml 4.00 1,270.00 5,080.00
600x425mm ml 8.00 1,480.00 11,840.00
750x425mm ml 8.00 1,600.00 12,800.00
750x450mm ml 4.00 1,760.00 7,040.00
750x500mm ml 4.00 1,820.00 7,280.00
750x525mm ml 4.00 1,920.00 7,680.00
875x500mm ml 8.00 2,100.00 16,800.00
900x550mm ml 8.00 2,410.00 19,280.00
1000x550mm ml 8.00 2,610.00 20,880.00
1000x575mm ml 16.00 2,765.00 44,240.00
1000x600mm ml 8.00 2,790.00 22,320.00
1075x600mm ml 4.00 3,245.00 12,980.00
1150x600mm ml 4.00 3,595.00 14,380.00

3.7 Dampers and accessories :

All dampers and accessories shall be manufactured as


per recognized codes, standards & and full fill the
requirements specified in the technical specification.

3.7.1 Volume Dampers


Supply, fix, test and commission volume dampers
of approved quality as where shown on the drawings.
Price shall include all the necessary accessories and
connecting pieces.
Model: AIR MASTER or Equivalent
For duct Size: 100 x 100 mmxmm/ VD No 189.00 1,865.00 352,485.00
125 x 100 mmxmm/ VD No 22.00 2,000.00 44,000.00
3.7.2 Fire Damper
Supply fix, test and commission fire dampers of
approved quality as specified and/or shown on the
drawings. Price shall include all the necessary
accessories and connecting pieces.
For duct Size: 1000 x 600 mmxmm/ FD No 1.00 20,100.00 20,100.00
1150 x 600 mmxmm/ FD No 1.00 21,500.00 21,500.00

3.7.3 Sound Attenuator

Supply fix, test and commission sound attenuator of


approved quality as specified and/or shown on the
drawings. Price shall include all the necessary
accessories and connecting pieces.
For duct Size: 1000 x 600 mmxmm/SA No 1.00 22,155.00 22,155.00
1150 x 600 mmxmm/ SA No 1.00 23,555.00 23,555.00

3.8 Flexible Duct

Page 66 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

Supply, fix, test and commission Xpelair or Equivalent


Flexible Duct of approved quality.
Price shall include all the necessary accessories and
connecting pieces.
Size: Dia 100mm, L=3m Ps 130.00 790.00 102,700.00
Dia 125mm, L=3m Ps 10.00 870.00 8,700.00

4 Extracting Kitchen Hood, fan and accessories


4.1 Supply, fix, test and commission stainless steel Grade
SS-304 thickness 1mm kitchen hoods of approved
quality as per the manufacturer's instruction and
shown on the drawing. Including :
- Grease filter with trap
- Condensate water trap
- Hangers / Support structures
- Canopy light made Flourcent
TYPE : Island
SIZE : (LxWxH): 2300x1600x500mm No 2.00 169,700.00 339,400.00

4.2 Duct
Supply,fix.test and commission galvanized steel air
supply and exhaust ducts as where shown on the
drawing. All duct construction & installation shall
follow the technical specification of this
project,standardes and recommendations
conditioning given on SMACNA (Sheet Metal and
Air Contractors National Association,INC) and
EBCS11.
Price shall also include all the necessary duct
reinforcement, fixing clamps to slabs,walls, vanes,
flange,corner,gasket etc and all the necessary
fittings and civil assistance works.
Galvanization coating should be 0.2mm thick.

Duct longer size (mm) Sheet metal thickness (mm)


Up to 600 mm 0.6 mm
600 to 800 mm 0.8 mm
800 to 1000 mm 0.9 mm
1000 to 1200 mm 1.0 mm
1200 to 1500 mm 1.3 mm
1500 to 2100 mm 1.5 mm

4.2.1 Exhaust duct


a) Rectangular return air duct
800x400 mm ml 12.00 2,898.00 34,776.00
925x600 mm ml 98.00 5,458.00 534,884.00

4.2.2 Supply duct


a) Rectangular supply air duct with insulation
350x250 mm ml 98.00 1,508.00 147,784.00

4.3 Kitchen Exhaust and Supply Air Fan


4.3.1 Kitchen Exhaust Air Fan

Page 67 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

Supply, fix, test and commission a complete


installation of DYNAIR or Equivalent Multi speed
centrifugal exhaust air fan unit with back ward
-curved blades, including duct mounted sound
attenuator/min.length=1.5xduct width/, inlet flange,
drain plug, inspection door, vibration isolator and all
accesseries including control panel/system as specified
in the manufacturer's instruction and shown on the
drawing. Casing shall be internaly lined with sound
proof material. Price shall incude flexible canvas
connector to duct system, mounting vibration
isolation, outlet connection & supports.
Maximum temprature limit = 120 deg centigrade
Accessories
- Multi speed switch
- Support feet
- Outlet rain grille
- Setting shutter
- All the fan component should be grease, moisture &
temperature resistant.
KITCHEN EXHAUST AIR FAN (KEF)
Exaust Fan Capacity = 4680 lt/sec
Total Pressure = 40mm H2O
Model: -
Estimated Power = -Kw
Altitude = 2355m.a.s.l.
Type: DYNAIR or Approved Equivalent No 1.00 774,075.00 774,075.00

4.3.2 Kitchen Supply Air Fan


a) SAF-a
Model: 7X4 -T6
Manufacturer: Dynair or Equivalent
Flow rate =625 liter/second
Total static pressure : 35 mm w.c.
Altitude = 2355m.a.s.l No 1.00 140,883.00 140,883.00

b) supply,install noise attenuator of approved quality


after the supply fan as shown in the drawing.
Flow rate= 625liter/second
Duct size= 350x250 No 1.00 14,881.00 14,881.00

c) supply,install cleanable filter of approved quality


after the supply fan as shown in the drawing. No 1.00 8,900.00 8,900.00

4.5 Dampers and accessories :

All dampers and accessories shall be manufactured as


per recognized codes, standards & and full fill the
requirements specified in the technical specification.

4.5.1 Volume Dampers


Supply, fix, test and commission volume dampers of
approved quality as where shown on the drawings.
Price shall include all the necessary accessories and
connecting pieces.

Model: AIR MASTER or Equivalent


For duct Size: 350 x 250 mmxmm/VD No 1.00 4,850.00 4,850.00
800 x 400 mmxmm/VD No 2.00 4,985.00 9,970.00

6.5.2 Sound Attenuator

Page 68 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

Supply, fix, test and commission sound attenuator of


approved quality as specified and/or shown on the
drawings. Price shall include all the necessary
accessories and connecting pieces.
For duct Size: 350 x 250 mmxmm/SA No 2.00 13,200.00 26,400.00

4.5.3 Fire Dampers


Supply ,fix,test and commission Fire Dampers of
approved quality as where shown on the drawings.
Price shall include all the necessary
accessories and connecting pieces.
For duct Size : 350X250 mm / FD No 1.00 5,048.00 5,048.00

4.6 Fresh Air and Weather Louver


Supply, fix, test and commission AIR MASTER or
Equivalent Fresh Air Louver of approved quality as
shown on the drawings. Price shall include all the
necessary accessories and connecting pieces.
Manufacturer: AIR MASTER or Equivalent
Size: 450 x 400 mmxmm No 5.00 9,700.00 48,500.00

4.7 Flexible Duct


Supply, fix, test and commission Xpelair or Equivalent
Flexible Duct of approved quality.
Price shall include all the necessary accessories and
connecting pieces.
Size: Dia 325mm, L=3m Ps 1.00 1,811.00 1,811.00

5
STAIR WELL PRESSURIZATION SYSTEM SUPPLY
FANS, DUCT WORKS AND ACCESSORIES

5.1 AIR SUPPLY FANS AND ACCESSORIES

Supply,fix,test and commission a complete installation


variable speed drive(VSD) centrifugal supply fan unit
with back ward-curved blades, including
PLC(programable logic controller), washable panel
filters, duct mounted sound attenuator
/min.length=1.5xduct width/, all as specified in the
manufacturer's instruction and shown on the drawing.
Casing shall be internaly lined with sound proof
material.
Price shall incude flexible canvas connector to duct
system, mounting feet, outlet connection & supports.
Provide with automatic cut-off control systems in case
of fire.

5.1.1 Pressurization Air Supply Fan.


TYPE:DYNAIR or equivalent
Air Flow = 2550 lit/sec
Static Pressure = 286 Pa (29.2 mm wg)

MODEL: 71
Power=1.5 Kw No 2.00 380,000.00 760,000.00

5.2 DUCT WORK


5.2.1 BASEMENTS PARKING EXTRACT AND
SUPPLY AIR DUCT
Supply, fix, test and commision rectangular toilet
exhaust duct made of 0.6mm galvanized steel sheet
complete with dampers and fittings including all
acessories. Duct work from uPVC, PN-4 is also
acceptable as long as it can be fitted to the flexible
duct work.

Page 69 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

200x200 mm ml 145.00 537.00 77,865.00


300x300 mm ml 5.00 805.00 4,025.00
400x350 mm ml 5.00 990.00 4,950.00
400x400 mm ml 5.00 1,100.00 5,500.00
450x450 mm ml 5.00 1,100.00 5,500.00
500x450 mm ml 7.00 1,270.00 8,890.00
500x500 mm ml 5.00 1,320.00 6,600.00
550x500 mm ml 5.00 1,480.00 7,400.00
550x550 mm ml 5.00 1,570.00 7,850.00
600x550 mm ml 5.00 1,620.00 8,100.00
600x600 mm ml 5.00 1,760.00 8,800.00
650x600 mm ml 5.00 1,820.00 9,100.00
650x650 mm ml 5.00 1,920.00 9,600.00
700x650 mm ml 15.00 2,100.00 31,500.00
700x700 mm ml 23.00 2,210.00 50,830.00

5.3 Supply Air Terminal Units


Supply, fix, test and commission Wall Mounted Supply
Air Diffusers /Air Grilles/. From high quality
extruded aluminium profile Frame and
standard(20mm) blade spacing. Price shall include
foam gasket seal around the back of the frame and
flexible duct connectors as required.

5.3.1 Stair well Pressurization Supply Air Grilles


SAG-H
Capacity =150 liter/sec
Size : 150 x 150 mmxmm
Type : air master or equivalent
Model: ASG-H
Colour: As per the Architect's preference No 34.00 4,200.00 142,800.00

5.4 Dampers and accessories :

All dampers and accessories shall be manufactured as


per recognized codes, standards & and full fill the
requirements specified in the technical specification.

5.4.1 Barometric Dampers


Supply ,fix, test and commission Normally closed
Automatic Barometric dampers with installed fire
damper in series with the vent damper of approved
quality as where shown on the drawings. Price shall
include all the necessary accessories and connecting
pieces. No 34.00 7,450.00 253,300.00

5.4.2 Volume Dampers


Supply ,fix, test and commission volume dampers
of approved quality as where shown on the drawings.
Price shall include all the necessary accessories and
connecting pieces.

For duct Size: 200 x 200 mmxmm/ VD No 34.00 1,980.00 67,320.00


700 x 700 mmxmm/ VD No 2.00 4,720.00 9,440.00

5.4.3 Fire Damper


Supply ,fix, test and commission fire dampers of
approved quality as specified and/or shown on the
drawings. Price shall include all the necessary
accessories and connecting pieces.
For duct Size: 700 x 700 mmxmm/ FD No 2.00 6,800.00 13,600.00

6 TOILET AIR EXTRACTION SYSTEM


6.1 Supply,fix.test and commission galvanized steel air
supply and exhaust ducts as where shown on the
drawing. All duct construction & installation shall

Page 70 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

follow the technical specification of this


project,standardes and recommendations
conditioning given on SMACNA (Sheet Metal and
Air Contractors National Association,INC) and
EBCS11.

Price shall also include all the necessary duct


reinforcement, fixing clamps to slabs,walls, vanes,
flange,corner,gasket etc and all the necessary
fittings and civil assistance works.
Galvanization coating should be 0.2mm thick.

Duct longer size (mm) Sheet metal thickness (mm)


Up to 600 mm 0.6 mm
600 to 800 mm 0.8 mm
800 to 1000 mm 0.9 mm
1000 to 1200 mm 1.0 mm
1200 to 1500 mm 1.3 mm
1500 to 2100 mm 1.5 mm

Exhaust Air Duct


100x100mm ml 210.00 400.00 84,000.00
125x100 mm ml 86.00 420.00 36,120.00
125x125 mm ml 8.00 440.00 3,520.00
200x125 mm ml 38.00 500.00 19,000.00
200x200 mm ml 6.00 680.00 4,080.00
225x200 mm ml 6.00 765.00 4,590.00
225x225mm ml 6.00 790.00 4,740.00
250x250mm ml 6.00 805.00 4,830.00
275x250mm ml 6.00 805.00 4,830.00
300x275mm ml 6.00 880.00 5,280.00
300x300mm ml 6.00 920.00 5,520.00
325x300mm ml 6.00 990.00 5,940.00
375x300 mm ml 6.00 1,000.00 6,000.00
400x300 mm ml 6.00 1,020.00 6,120.00
450x300mm ml 6.00 1,200.00 7,200.00
475x300mm ml 6.00 1,260.00 7,560.00
500x300mm ml 6.00 1,310.00 7,860.00
550x300mm ml 6.00 1,400.00 8,400.00
575x300mm ml 6.00 1,450.00 8,700.00
625x300mm ml 6.00 1,490.00 8,940.00
650x300mm ml 6.00 1,550.00 9,300.00
700x300mm ml 6.00 1,600.00 9,600.00
725x300mm ml 6.00 1,650.00 9,900.00
775x300mm ml 6.00 1,760.00 10,560.00
825x300mm ml 6.00 1,820.00 10,920.00
775x300mm ml 6.00 1,990.00 11,940.00
850x300 mm ml 6.00 2,010.00 12,060.00
900x300 mm ml 6.00 2,080.00 12,480.00
975x300 mm ml 6.00 2,180.00 13,080.00

6.2 Exhaust Air Fans


Supply, Fix, test and commision DYNAIR or Equivalent
Twin extract fans having two motors as shown on the
drawing, complete with all accessories including control
systems for alternate operation of the flow fans.

6.2.1 Exhaust Air Fans


i) Exhaust Air Fan (TAF-1)
Model: -
Type= DYNAIR or Equivalent
Discharge = 2030 lt/sec
Head = 35 mm H2O
Power input = - kw
Altitude: 2355 m.a.s.l. No 1.00 750,500.00 750,500.00

Page 71 of 161
MIXED USE BUILDING
FOR
NOC

Item
Description Unit QTY Rate Amount
no

ii) Toilet Exhaust Air Fan (TAF-2)


Model: -
Type= DYNAIR or Equivalent
Discharge = 1800 lt/sec
Head = 35 mm H2O
Power input = - kw
Altitude: 2355 m.a.s.l. No 1.00 665,460.00 665,460.00

6.3 Exhaust Air Grills


Supply, Fix, test and commision AIR MASTER or
Equivalent Exhaust Air Grills. The frame and blade be
made from high quality extrude alluminium pofile.
Price shall include fixing foam gasket seal around the
back of the frame and flexible duct connector as
reqired; and all the necessary adaptor and fixings to
make the system complet shown on the drawing,
complete with all fixing accessories

6.3.1 Exhaust Air Grills


Toilet Exhaust Air Grill (TEG)
Type= AIRMASTER or Equivalent
Exhaust Flow rate = 20 & 40lt/sec
Size: 150x150mm No 161.00 3,510.00 565,110.00

6.4 Dampers and accessories :


All dampers and accessories shall be manufactured
as per recognized codes,standards & and full fill the
requirments specified in the technical specification.

6.4.1 Volume Dampers


Supply, fix,test and commission volume dampers of

approved quality as where shown on


the drawings. Price shall include all the necessary
accessories and connecting pieces.
For duct Size: 100x100 VD No 161.00 1,865.00 300,265.00

6.4.2 Fire Dampers


Supply,fix,test and commission fire dampers of

AIRMASTER or Approved quality as where shown on


Price shall include all the necessary
accessories and connecting pieces.

For duct Size: 850x300 FD No 1.00 17,200.00 17,200.00


975x300 FD No 2.00 18,500.00 37,000.00

6.5 Door Grilles


Supply, fix, test and commission Door Grilles of
AIRMASTER or Approved quality as where shown on
the drawings.
Price shall include all the necessary accessories and
connecting pieces.
For duct Size: 300x150 DG No 138.00 3,590.00 495,420.00

6.6 Flexible Duct


Supply, fix, test and commission Xpelair or Equivalent
Flexible Duct of approved quality.
Price shall include all the necessary accessories and
connecting pieces.
Size: Dia 100mm, L=3m Ps 65.00 424.00 27,560.00
TOTAL CARRIED TO SUMMARY ................................................... 73,411,966.00

Page 72 of 161
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION
A - SUB STRUCTURE

1. EXCAVATION & EARTH WORK

1.1. 20cm thick site clearance.


1 1594.00 1594.00 Adding 1200mm both side of the building A
1594.00 m2 Total of item 1.1

1.2. Bulk excavation upto 1500mm depth.

1 1594.00 Adding 500mm both side of the building A=


1.50 2391.00
2391.00 m3 Total of item 1.2

above 1500 but not exceeding 3000mm


1 1594.00 Adding 500mm both side of the building A=
1.50 2391.00
2391.00 m3 Total of item 1.2

above 3000 but not exceeding 4500mm


1 1594.00 Adding 500mm both side of the building A=
1.50 2391.00
2391.00 m3 Total of item 1.2

above 4500 but not exceeding 6000mm


1 1594.00 Adding 500mm both side of the building A=
1.50 2391.00
2391.00 m3 Total of item 1.2

above 6000 but not exceeding 7500mm


1 1594.00 Adding 500mm both side of the building A=
1.50 2391.00
2391.00 m3 Total of item 1.2

above 7500 but not exceeding 9000mm


1 1594.00 Adding 500mm both side of the building A=
1.50 2391.00
2391.00 m3 Total of item 1.2

1.60 Back Fill around foundation


14346.00 Excavation for bulk
ddt
-2124.00 Enclosed building
12222.00 m3 Total for item no 1.60

Back fill under hard core


1 28.95
48.00 1389.60
1389.60

1.10. Cartaway.
Cartaway = ( All excavated material - Backfill )
2442.80
2442.80 2442.80 Total = m3
2442.80 m3 Total

1.11. 250mm thick hardcore.


for ground floor
Along axA&B
1 28.31
47.40 1341.89
1341.89 m2 Total of item 1.12

73
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION

2. CONCRETE WORKS
2.1. C-5 & 5cm thick lean concrete
a) Under Mat Slab
1 29.01 Mat Slab
48.10 1395.38
1395.38 m2 Total

74
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION

2.2. C-25 RC
500mm thick mat Slab
1 28.91
48.00
0.40 555.07
555.07 m3 Total

b) Basment Column
At third basment
11 2.45 C1
0.50
0.50 13.48

12 2.45 C2
0.70
0.70 20.58

10 2.45 C3
0.70
0.70 17.15

7 2.45 C4
0.60
0.60 10.29

8 2.45 C5
0.40
0.40 7.84
At second Basment
11 3.45 C1
0.50
0.50 18.98

12 3.45 C2
0.70
0.70 28.98

10 2.45 C3
0.70
0.70 17.15

7 2.45 C4
0.60
0.60 10.29

8 2.45 C5
0.40
0.40 7.84
At first Basment
11 3.45 C1
0.70
0.70 26.57

12 3.45 C2
0.70
0.70 28.98

10 3.45 C3
0.70
0.70 24.15

7 3.45 C4
0.60
0.60 14.49

8 3.45 C5
0.40
0.40 11.04
257.80 m3 Total

b) In 100mm thick third Basment floor slab


1 28.31
47.40 1341.89
1341.89 m2 total

a) 150mm thick Suspended Flat slab


For 1st & Second basment
2 28.31 0.00
47.40 2683.79 0.00
ddt due Stair case
Stair 1
-2 33.89 -67.78
Stair 2
-2 39.18 -78.36
Ramp
-2 143.74 -287.48
For Ground floor Slab
1 28.31 0.00
47.40 1341.89
ddt due Stair case
Stair 1
-1 33.89 -33.89
Stair 2
-1 39.18 -39.18
Ramp
-1 143.74 -143.74
3375.25 m2 total

d) In 300mm thick RC Retaining Wall


At third floor
0.00 0.00 Along Ax-1& 9
2 25.91
3.52
0.30 54.72
Along Ax A & F
2 44.00
3.52
0.30 92.93
ddt due window
-1 44.40
0.70
0.30 -9.32
At second Basment
0.00 Along Ax-1& 9
2 25.91
3.53
0.30 54.88
Along Ax A & F
2 44.00
3.53
0.30 93.19
ddt due window
-1 44.40
0.70
0.30 -9.32
At first basment
0.00 Along Ax-1& 9
2 25.91
3.52
0.30 54.72
Along Ax A & F
2 44.00
3.52
0.30 92.93
ddt due window
-1 44.40
0.70
0.30 -9.32
415.40 m3 total

75
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION

In RC Wall
At third Basment
W-2/1
2 3.20
3.52
0.40 9.01
W-2/2
2 1.50
3.52
0.40 4.22
W-3/1
1 5.18
3.52
0.40 7.30

1 4.00
3.52
0.40 5.63
W-3/2
1 2.85
3.52
0.40 4.01

1 0.62 l-shap near to wall


3.52
0.40 0.87

76
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION
W-3/3
2 2.50
3.52
0.20 3.52
W-3/4
1 5.76
3.52
0.20 4.06
W-3/5
1 4.80
3.52
0.40 6.76
W-3/6
1 4.40
3.52
0.20 3.10
W-3/7
1 5.70
3.52
0.40 8.03
W-3/8
1 1.15
3.52
0.40 1.62
Wall near to W/8 & 6
1 2.80
3.52
0.40 3.94
W-3/9
2 0.83
3.52
0.40 2.32
W-3/10
2 5.18
3.52
0.40 14.60
W-4/1
3 3.08
3.52
0.30 9.76
At second basment
W-2/1
2 3.20
3.52
0.40 9.01
W-2/2
2 1.50
3.52
0.40 4.22
W-3/1
1 5.18
3.52
0.40 7.30
ddt due dooor
-2 1.30
2.20
0.40 -2.29

1 4.00
3.52
0.40 5.63
W-3/2
1 2.85
3.52
0.40 4.01

1 0.62 l-shap near to wall


3.52
0.40 0.87
W-3/3
2 2.50
3.52
0.20 3.52
W-3/4
1 5.76
3.52
0.20 4.06
W-3/5
1 4.80
3.52
0.40 6.76
ddt due dooor
-1 1.30
2.20
0.40 -1.14
W-3/6
1 4.40
3.52
0.20 3.10
W-3/7
1 5.70
3.52
0.40 8.03
W-3/8
1 1.15
3.52
0.40 1.62
Wall near to W/8 & 6
1 2.80
3.52
0.40 3.94
W-3/9
2 0.83
3.52
0.40 2.32
ddt due dooor
-1 1.30
2.20
0.40 -1.14
W-3/10
2 5.18
3.52
0.40 14.60
ddt due dooor
-1 1.30
2.20
0.40 -1.14
W-4/1
3 3.08
3.52
0.30 9.76
At First basment
W-2/1
2 3.20
3.52
0.40 9.01
W-2/2
2 1.50
3.52
0.40 4.22
W-3/1
1 5.18
3.52
0.40 7.30
ddt due dooor
-4 1.30
2.20
0.40 -4.58

1 4.00
3.52
0.40 5.63
W-3/2
1 2.85
3.52
0.40 4.01

1 0.62 l-shap near to wall


3.52
0.40 0.87
W-3/3
2 2.50
3.52
0.20 3.52
W-3/4
1 5.76
3.52
0.20 4.06
W-3/5
1 4.80

77
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION
3.52
0.40 6.76
ddt due dooor
-1 1.30
2.20
0.40 -1.14
W-3/6
1 4.40
3.52
0.20 3.10
W-3/7
1 5.70
3.52
0.40 8.03
W-3/8
1 1.15
3.52
0.40 1.62
Wall near to W/8 & 6
1 2.80
3.52
0.40 3.94
W-3/9
2 0.83
3.52
0.40 2.32
ddt due dooor
-1 1.30
2.20
0.40 -1.14
W-3/10
2 5.18
3.52
0.40 14.60
ddt due dooor
-1 1.30
2.20
0.40 -1.14
W-4/1
3 3.08
3.52
0.30 9.76
252.49 m3 Total

Lift Shaft Shear wall


2 2.72
10.35
0.30 16.90

1 1.98
10.35
0.30 6.14

1 1.90
10.35
0.30 5.90
28.95

78
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION
150mm thick Ramp
From Ground to First Basment
1 18.43
6.60 121.62
From First to Second Basment
1 18.43
6.60 121.62
From second to third Basment
1 18.43
6.60 121.62
364.85 m3 Total

Staircase and landing


From third Basment to Ground Floor
Stair 1
33 1.30 Tread
0.30
0.15 1.93

66 1.30 Soffit
0.34
0.15 4.38

3 2.72 Landing
1.12
0.15 1.37

3 2.70 STB
0.30
0.40 0.97
Stair 2
30 1.20 Tread
0.30
0.15 1.62

60 1.20 Soffit
0.34
0.15 3.67
Landing
3 2.70
1.34
0.15 1.63
STB
3 2.70
0.30
0.40 0.97
16.54 m3 Total

79
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION

Form work
500mm thick mat Slab
2 76.91 0.00
0.40 61.53
61.53 m2 Total

b) Basment Column
At third basment
11 2.45 0.00 C1
2.00 53.90 0
0
0
12 2.45 0.00 C2
2.80 82.32 0
0
0
10 2.45 0.00 C3
2.80 68.60 0
0
0
7 2.45 0.00 C4
2.40 41.16 0
0
0
8 2.45 0.00 C5
1.60 31.36 0
0
At second Basment
11 3.45 0.00 C1
2.00 75.90 0
0
0
12 3.45 0.00 C2
2.80 115.92 0
0
0
10 2.45 0.00 C3
2.80 68.60 0
0
0
7 2.45 0.00 C4
2.40 41.16 0
0
0
8 2.45 0.00 C5
1.60 31.36 0
0
At first Basment
11 3.45 0.00 C1
2.80 106.26 0
0
0
1 2.45 0.00 C2
1.41 3.46 0
0
0
1 2.45 0.00 C3
1.41 3.46 0
0
0
1 2.45 0.00 C4
1.41 3.46 0
0
0
16 2.45 0.00 C5
1.20 47.04 0
773.97

d) In 300mm thick RC Retaining Wall


0.00 At third floor
0.00 Along Ax-1& 9
4 25.91 0.00
3.52 364.81 0.00

0.00 Along Ax A & F


4 44.00 0.00
3.52 619.52 0.00
0.00 ddt due window
-1 44.40 0.00
0.20 -8.88 0.00

-2 0.70
0.20 -0.28 0.00

0.00 At second Basment


0 0.00 Along Ax-1& 9
4 25.91 0.00
0 3.53 365.85 0.00

0 0.00 Along Ax A & F


4 44.00 0.00
0 3.53 621.28 0.00
0 0.00 ddt due window
-2 44.40 0.00
0 0.20 -17.76 0.00

-2 0.70
0.20 -0.28
0 0.00 At first basment
0.00 Along Ax-1& 9
4 25.91 0.00
0 3.52 364.81 0.00
0.00 Along Ax A & F
4 44.00 0.00
0 3.52 619.52 0.00
0 0.00 ddt due window
-2 44.40 0.00
0 0.20 -17.76 0.00

-2 0.70
0.20 -0.28
0.00 2910.55

In RC Wall
At third Basment
0.00 W-2/1
2 3.20 0.00
3.52 22.53

0.00 W-2/2
2 1.50 0.00
3.52 10.56

0.00 W-3/1
1 5.18 0.00
3.52 18.25

0.00 0.00
1 4.00 0.00
3.52 14.08

0.00 W-3/2
1 2.85 0.00
3.52 10.03

0.00 0.00
1 0.62 0.00
3.52 2.17

0.00 W-3/3
2 2.50 0.00
3.52 17.60

0.00 W-3/4
1 5.76 0.00
3.52 20.28

0.00 W-3/5
1 4.80 0.00
3.52 16.90

0.00 W-3/6
1 4.40 0.00
3.52 15.49

0.00 W-3/7
1 5.70 0.00
80
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION
3.52 20.06

0.00 W-3/8
1 1.15 0.00
3.52 4.05

0.00 Wall near to W/8 & 6


1 2.80 0.00
3.52 9.84

0.00 W-3/9
2 0.83 0.00
3.52 5.81

0.00 W-3/10
2 5.18 0.00
3.52 36.50

0.00 W-4/1
3 3.08 0.00
3.52 32.52

0.00 At second basment


0.00 W-2/1
2 3.20 0.00
3.52 22.53

0.00 W-2/2
2 1.50 0.00
3.52 10.56

0.00 W-3/1
1 5.18 0.00
3.52 18.25

0.00 ddt due dooor


-2 1.30 0.00
2.20 -5.72

0.00 0.00
1 4.00 0.00
3.52 14.08

0.00 W-3/2
1 2.85 0.00
3.52 10.03

0.00 0.00
1 0.62 0.00
3.52 2.17

0.00 W-3/3
2 2.50 0.00
3.52 17.60

0.00 W-3/4
1 5.76 0.00
3.52 20.28

0.00 W-3/5
1 4.80 0.00
3.52 16.90

0.00 ddt due dooor


-1 1.30 0.00
2.20 -2.86

0.00 W-3/6
1 4.40 0.00
3.52 15.49

0.00 W-3/7
1 5.70 0.00
3.52 20.06

0.00 W-3/8
1 1.15 0.00
3.52 4.05

0.00 Wall near to W/8 & 6


1 2.80 0.00
3.52 9.84

0.00 W-3/9
2 0.83 0.00
3.52 5.81

0.00 ddt due dooor


-1 1.30 0.00
2.20 -2.86

0.00 W-3/10
2 5.18 0.00
3.52 36.50

0.00 ddt due dooor


-1 1.30 0.00
2.20 -2.86

0.00 W-4/1
3 3.08 0.00
3.52 32.52
499.03
Lift Shaft Shear wall
2 4.94
10.35 102.30

2 1.98
10.35 40.97

1 4.80
10.35 49.68
192.94

150mm thick Ramp


0.00 From Ground to First Basment
1 18.43
6.60 121.62
0.00 From First to Second Basment
1 18.43
6.60 121.62
0.00 From second to third Basment
1 18.43
6.60 121.62
364.85 m2 Total

e) Stair
66 1.30 Tread
0.15 12.87

66 1.30 Soffit
0.15 12.87

132 0.30 Sides


0.34 13.46

3 2.72 Landing
1.12 9.15

3 2.70 STB
1.10 8.91
0.00
Stair 2
60 1.20 Tread
0.15 10.80

60 1.20 Soffit
0.34 24.48

120 0.30 Sides


0.34 12.24

3 2.70 0.00
1.10 8.91
113.69 m2 Total

81
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION

2.4. Expansion joint.


Ground
0.00
0.00 ml Total

82
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION

2.5. Reinforcement bar.


a) Ø6mm Plain bar

813.57 kg Total

a) Ø8mm Deformed bar

#VALUE! kg Total

b) Ø10mm Deformed bar

992.67 kg Total

c) Ø12mm Deformed bar

#VALUE! kg Total

d) Ø14mm Deformed bar

#VALUE! kg Total

e) Ø16mm Deformed bar

#REF! kg Total

g) Ø20mm Deformed bar

#REF! kg Total

h) Ø24mm Deformed bar

0.00 kg Total

83
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION

B - SUPER STRUCTURE
Elevation Column
1 4.85 C1
0.70
0.70 2.38

1 11.35 C2
0.70
0.70 5.56

1 17.05
0.60
0.60 6.14

1 27.00 0
0.40
0.40 4.32

1 21.40 C3
0.70
0.70 10.49

1 16.75
0.60
0.60 6.03

1 10.15
0.40
0.40 1.62

1 20.79 C4
0.60
0.60 7.49

1 17.49
0.60
0.60 6.29

1 11.73
0.40
0.40 1.88
52.19 m3 Total

150mm thick Rc Flat slab


Mezzanine floor
All floor poly line
1 619.15 619.15
ddt due to staircase
-1 6.53
6.24 -40.75

-1 6.53
5.22 -34.13
First floor
All floor poly line
1 1226.57 1226.57
ddt due to staircase
-1 6.53
6.24 -40.75

-1 6.53
5.22 -34.13
Second floor slab
All floor poly line
1 1098.73 1098.73
ddt due to staircase
-1 6.53
6.24 -40.75

-1 6.53
5.22 -34.13
Third floor slab
All floor poly line
1 1153.14 1153.14
ddt due to staircase
-1 6.53
6.24 -40.75

-1 6.53
5.22 -34.13
Fourth floor
All floor poly line
1 1153.14 1153.14
ddt due to staircase
-1 6.53
6.24 -40.75

-1 6.53
5.22 -34.13
Fifth floor
All floor poly line
1 1192.96 1192.96
ddt due to staircase
-1 6.53
6.24 -40.75

-1 6.53
5.22 -34.13
Six floor
All floor poly line
1 1161.17 1161.17
ddt due to staircase
-1 6.53
6.24 -40.75

-1 6.53
5.22 -34.13
Seventh floor
All floor poly line
1 1157.11 1157.11
ddt due to staircase
-1 6.53
6.24 -40.75

-1 6.53
5.22 -34.13
Eight floor
All floor poly line
1 1117.31 1117.31
ddt due to staircase
-1 6.53
6.24 -40.75

-1 6.53
5.22 -34.13
Nine floor
All floor poly line
1 1087.93 1087.93
ddt due to staircase
-1 6.53
6.24 -40.75

-1 6.53
5.22 -34.13
Ten floor
All floor poly line
1 1101.02 1101.02
ddt due to staircase
-1 6.53
6.24 -40.75

-1 6.53
5.22 -34.13
eleventh floor
All floor poly line
1 923.05 923.05
ddt due to staircase
-1 6.53
6.24 -40.75

-1 6.53
5.22 -34.13
Twelve floor
All floor poly line
1 846.31 846.31
ddt due to staircase
-1 6.53
84
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION
6.24 -40.75

-1 6.53
5.22 -34.13
12864.15

Staircase and landing


From Ground toTwelev floor
Stair 1
132 1.30 Tread
0.30
0.15 7.72

264 1.30 Soffit


0.34
0.15 17.50

12 2.72 Landing
1.12
0.15 5.49

12 2.70 STB
0.30
0.40 3.89
Stair 2
132 1.20 Tread
0.30
0.15 7.13

264 1.20 Soffit


0.34
0.15 16.16
Landing
12 2.70
1.34
0.15 6.52
STB
12 2.70
0.30
0.40 3.89
68.29 m3 Total

85
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION

In RC Wall
At Ground to 12th floor floor
W-2/1
2 3.20
51.51
0.40 131.87
W-2/2
2 1.50
51.51
0.40 61.81
W-3/1
1 5.18
51.51
0.40 106.81

1 4.00
51.51
0.40 82.42
W-3/2
1 2.85
51.51
0.40 58.72

1 0.62 l-shap near to wall


51.51
0.40 12.71
W-3/3
2 2.50
51.51
0.20 51.51
W-3/4
1 5.76
51.51
0.20 59.35
W-3/5
1 4.80
51.51
0.40 98.90
W-3/6
1 4.40
51.51
0.20 45.33
W-3/7
1 5.70
51.51
0.40 117.44
W-3/8
1 1.15
51.51
0.40 23.69
Wall near to W/8 & 6
1 2.80
51.51
0.40 57.61
W-3/9
2 0.83
51.51
0.40 34.00
W-3/10
2 5.18
51.51
0.40 213.62
W-4/1
3 3.08
51.51
0.30 142.79
1298.58

Lift Shaft Shear wall


2 2.72
51.51
0.30 84.13

1 1.98
51.51
0.30 30.58

1 1.90
51.51
0.30 29.36
144.07

1.2. Formwork to
a) Elevation columns
1 4.85 C1
1.41 6.85

2 11.35 C2
1.40 31.78

1 17.05 0.00
1.41 24.09

2 27.00 0.00
0.80 43.20

2 21.40 C3
1.40 59.92

2 16.75 0.00
1.20 40.20

2 10.15 0.00
0.80 16.24

2 20.79 C4
1.20 49.91

2 17.49 0.00
1.20 41.96

2 11.73 0.00
0.80 18.76
332.92 m3 Total

0 0.00 150mm thick Rc Flat slab


0.00 0.00 For Roof Slab
Mezzanine floor
1 619.15 619.15 All floor poly line
0 0.00 0.00 0.00
-1 6.53 ddt due to staircase
0 6.24 -40.75 0.00
0 0.00 0.00
-1 6.53 0.00
0 5.22 -34.13 0.00
0 0.00 0.00 0.00
0 0.00 0.00 First floor
1 1226.57 1226.57 All floor poly line
0 0.00 0.00 0.00
-1 6.53 ddt due to staircase
0 6.24 -40.75 0.00
0 0.00 0.00
-1 6.53 0.00
0 5.22 -34.13 0.00
0 0.00 0.00 0.00
0 0.00 0.00 Second floor slab
1 1098.73 1098.73 All floor poly line
0 0.00 0.00 0.00
-1 6.53 ddt due to staircase
0 6.24 -40.75 0.00
0 0.00 0.00
-1 6.53 0.00
0 5.22 -34.13 0.00
0 0.00 0.00 0.00
0 0.00 0.00 Third floor slab
1 1153.14 1153.14 All floor poly line
0 0.00 0.00 0.00
-1 6.53 ddt due to staircase
0 6.24 -40.75 0.00
0 0.00 0.00
-1 6.53 0.00
86
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION
0 5.22 -34.13 0.00
0 0.00 0.00 0.00
0 0.00 0.00 Fourth floor
1 1153.14 1153.14 All floor poly line
0 0.00 0.00 0.00
-1 6.53 ddt due to staircase
0 6.24 -40.75 0.00
0 0.00 0.00
-1 6.53 0.00
0 5.22 -34.13 0.00
0 0.00 0.00 0.00
0 0.00 0.00 Fifth floor
1 1192.96 1192.96 All floor poly line
0 0.00 0.00 0.00
-1 6.53 ddt due to staircase
0 6.24 -40.75 0.00
0 0.00 0.00 0.00
-1 6.53 0.00
0 5.22 -34.13 0.00
0 0.00 0.00 0.00
0 0.00 0.00 Six floor
1 1161.17 1161.17 All floor poly line
0 0.00 0.00 0.00
-1 6.53 ddt due to staircase
0 6.24 -40.75 0.00
0 0.00 0.00
-1 6.53 0.00
0 5.22 -34.13 0.00
0 0.00 0.00 0.00
0 0.00 0.00 Seventh floor
1 1157.11 1157.11 All floor poly line
0 0.00 0.00 0.00
-1 6.53 ddt due to staircase
0 6.24 -40.75 0.00
0 0.00 0.00 0.00
-1 6.53 0.00
0 5.22 -34.13 0.00
0 0.00 0.00 0.00
0 0.00 0.00 Eight floor
1 1117.31 1117.31 All floor poly line
0 0.00 0.00 0.00
-1 6.53 ddt due to staircase
0 6.24 -40.75 0.00
0 0.00 0.00 0.00
-1 6.53 0.00
0 5.22 -34.13 0.00
0 0.00 0.00 0.00
0 0.00 0.00 Nine floor
1 1087.93 1087.93 All floor poly line
0 0.00 0.00 0.00
-1 6.53 ddt due to staircase
0 6.24 -40.75 0.00
0 0.00 0.00
-1 6.53 0.00
0 5.22 -34.13 0.00
0 0.00 0.00 0.00
0 0.00 0.00 Ten floor
1 1101.02 1101.02 All floor poly line
0 0.00 0.00 0.00
-1 6.53 ddt due to staircase
0 6.24 -40.75 0.00
0 0.00 0.00
-1 6.53 0.00
0 5.22 -34.13 0.00
0 0.00 0.00 0.00
0 0.00 0.00 eleventh floor
1 923.05 923.05 All floor poly line
0 0.00 0.00 0.00
-1 6.53 ddt due to staircase
0 6.24 -40.75 0.00
0 0.00 0.00 0.00
-1 6.53 0.00
0 5.22 -34.13 0.00
0 0.00 0.00 0.00
0 0.00 0.00 Twelve floor
1 846.31 846.31 All floor poly line
0 0.00 0.00 0.00
-1 6.53 ddt due to staircase
0 6.24 -40.75 0.00
0 0.00 0.00
-1 6.53 0.00
0 5.22 -34.13 0.00
12126.85 m2 Total
0.00

e) Stair
From Ground toTwelev floor
0.00 0.00 Stair 1
264 1.30 0.00 Tread
0.15 51.48 0.00
0.00
0.00
264 1.30 0.00 Soffit
0.34 116.69 0.00
0.00
0.00
12 2.72 0.00 Landing
1.12 36.60 0.00
0.00
0.00
12 2.70 0.00 STB
1.00 32.40 0.00
0.00
Stair 2
264 1.20 0.00 Tread
0.15 47.52 0.00
0.00
0.00
264 1.20 0.00 Soffit
0.34 107.71 0.00
0.00
Landing
12 2.70 0.00 0.00
1.34 43.45 0.00
0.00
STB
12 2.70 0.00 0.00
1.00 32.40 0.00
468.25 m2 Total

87
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION

In RC Wall
At Ground to 12th floor floor
0.00 W-2/1
2 6.80 0.00 0.00
51.51 700.54 0.00
0.00
W-2/2
2 3.00 0.00 0.00
51.51 309.06 0.00
0.00
W-3/1
1 10.37 0.00 0.00
51.51 534.06 0.00
0.00
0.00
1 8.80 0.00 0.00
51.51 453.29 0.00
0.00
W-3/2
1 5.10 0.00 0.00
51.51 262.70 0.00
0.00
0.00
1 1.63 0.00 l-shap near to wall
51.51 84.17 0.00
0.00
W-3/3
2 5.00 0.00 0.00
51.51 515.10 0.00
0.00
W-3/4
1 11.12 0.00 0.00
51.51 572.89 0.00
0.00
W-3/5
1 9.60 0.00 0.00
51.51 494.50 0.00
0.00
W-3/6
1 8.60 0.00 0.00
51.51 442.99 0.00
0.00
W-3/7
1 11.40 0.00 0.00
51.51 587.21 0.00
0.00
W-3/8
1 2.50 0.00 0.00
51.51 128.78 0.00
0.00
Wall near to W/8 & 6
1 5.79 0.00 0.00
51.51 298.35 0.00
0.00
W-3/9
2 1.65 0.00 0.00
51.51 169.98 0.00
0.00
W-3/10
2 10.17 0.00 0.00
51.51 1047.51 0.00
0.00
W-4/1
3 6.56 0.00 0.00
51.51 1013.72 0.00
7614.83

Lift Shaft Shear wall


2 4.94
51.51 509.12

2 1.98
51.51 203.88

1 4.80
51.51 247.25
960.25

2.5. Reinforcement bar.


a) Ø6mm Plain bar

kg Total
#VALUE!
a) Ø8mm Deformed bar

kg Total
#REF!
b) Ø10mm Deformed bar

kg Total
1182.79
c) Ø12mm Deformed bar

kg Total
3121.71
d) Ø14mm Deformed bar

kg Total
#REF!
e) Ø16mm Deformed bar

kg Total
#REF!
f) Ø20mm Deformed bar

kg Total
222.24
f) Ø24mm Deformed bar

kg Total

88
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION
0.00

2.Block Work
200mm thick HCB
External
At Ground Floor
Along B/n Ax B & C
1 6.63
3.20 21.22
Along B/n Ax-D& E
1 11.26
3.20 36.03
ddt due door
-1 1.60 D6
2.10 -3.36
Along B/n Ax 3&4
1 20.18
3.20 64.58
ddt due door
-2 1.60 D6
2.10 -6.72
Along B/n Ax 4&5
1 7.49
3.20 23.97
Along B/n Ax 5&6
1 7.55
3.20 24.16
Along Ax-6
1 1.88
3.20 6.02
Along B/n Ax 6&7
1 11.02
3.20 35.26
ddt due door
-1 1.85 D2
2.10 -3.89
For mezzanine floor
Along Ax-1
1 11.80
3.50 41.30
ddt due window
-3 0.90
0.80 -2.16

-2 1.30
0.80 -2.08
Along B/n Ax 3& 4
1 1.93
3.50 6.76
Along B/n Ax 6 & 7
1 4.27
3.50 14.95
Along Ax A
1 7.15
3.50 25.03
Along B/n Ax-D&E
1 3.03
3.50 10.61
Along Ax F
1 9.39
3.50 32.87
For r 2nd & 4th floor
Along Near Ax-1
2 14.60
3.08 89.94
ddt due window
-2 1.20
0.80 -1.92

-2 1.00
0.80 -1.60

-4 1.00
3.08 -12.32
along Ax-4
2 13.62
3.08 83.90
ddt due window
-2 2.60
3.08 -16.02

-2 3.40
3.08 -20.94
Along Ax-A
2 15.50
3.08 95.48
ddt due window
-8 1.00
1.90 -15.20

-2 1.50
1.90 -5.70

89
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION
Along Ax-D
2 15.50
3.08 95.48
ddt due window
-6 1.00
1.90 -11.40

-2 1.50
1.90 -5.70

-2 2.00
1.90 -7.60
At terrace roof
Along Near Ax-1
1 9.35
3.08 28.80
Along B/n Ax-1&2
1 4.25
3.08 13.09
Along B/n Ax-2&3
1 4.90
3.08 15.09
ddt due window
-1 3.00
1.90 -5.70
Along Ax-B
1 7.65
3.08 23.56
ddt due door
-1 1.20
2.10 -2.52
Along Ax-D
1 4.25
3.08 13.09
ddt due Window
-1 1.00
1.90 -1.90
ddt due window
-2 1.50
1.60 -4.80

-2 2.00
1.60 -6.40
663.23 M2 total 200mm thick external wall

90
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION

200mm thick HCB


B. Internal
For third basement
Along ax-03
1 3.32
2.70 8.96
Along Ax-4
1 2.50
2.70 6.75
Along Ax-6
1 4.91
2.70 13.26
Along B/n Ax 6 & 7
1 4.04
2.70 10.91
Along Ax-7
1 4.91
2.70 13.26
ddt due door
-1 0.80
2.10 -1.68
Along B/n Ax-A&B
1 9.50
2.70 25.65
ddt due door
-2 0.80
2.10 -3.36
Along Ax-B
1 22.00
2.70 59.40
Along Ax-C& D
2 2.00
2.70 10.80
For second Basment
Along ax-03
1 3.37
2.70 9.10
Along Ax-4
1 4.41
2.70 11.91
Along Ax-6
1 4.41
2.70 11.91
Along B/n Ax 6 & 7
1 4.34
2.70 11.72
Along Ax-7
1 4.45
2.70 12.02
ddt due door
-1 0.80
2.10 -1.68
Along B/n Ax-A&B
1 9.50
2.70 25.65
ddt due door
-1 0.80
2.10 -1.68
Along Ax-B
1 22.00
2.70 59.40
Along Ax-C& D
2 2.00
2.70 10.80
For First Basment
Along ax-03
1 3.37
2.70 9.10
Along Ax-4
1 2.45
2.70 6.62
Along Ax-6
1 4.43
2.70 11.96
Along B/n Ax 6 & 7
1 4.34
2.70 11.72
Along Ax-7
1 4.50
2.70 12.15
ddt due door
-1 0.80
2.10 -1.68
Along B/n Ax-A&B
1 3.50
2.70 9.45
ddt due door
-1 0.80
2.10 -1.68
Along Ax-B
1 22.00
2.70 59.40
Along Ax-C& D
2 2.00
2.70 10.80
For Ground floor
Along B/n Ax B & C
1 3.17
3.20 10.14
Along Ax-C
1 0.82
3.20 2.62
Along Ax-D
1 12.99
3.20 41.57
Along B/n Ax D&E
1 21.80
3.20 69.76
Along Ax-1
1 12.15
3.20 38.88
ddt due window
-1 1.60 W1
1.20 -1.92

-1 1.20 W2
1.20 -1.44

-1 2.80 W3
1.20 -3.36
Along B/n Ax 2 &3
1 13.36
3.20 42.75
Along B/n Ax 4 &5
1 10.52
3.20 33.66
For Mezzanine Floor
Along B/n Ax 1&2
1 4.27
3.20 13.66
ddt due door
-1 0.90
2.10 -1.89
Along Ax-2
1 20.50
3.20 65.60
Along B/n Ax 3 &4
1 2.43
3.20 7.78
Along B/n Ax 4 &5
1 10.70
3.20 34.24
Along B/n Ax 6 &7
1 8.28
3.20 26.50
Along Ax-D
1 14.39
3.20 46.05
Along B/n Ax D & E
1 24.93
3.20 79.78
ddt due door
-1 1.60 D6
2.10 -3.36
Ditto but first floor
Along B/n Ax 4 & 5
91
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION
1 7.67
3.20 24.54
Along B/n Ax 5 & 6
1 7.56
3.20 24.19
Along B/n Ax B & C
1 6.22
3.20 19.90
Along B/n Ax D & E
1 16.12
3.20 51.58
ddt due door
-2 0.80 D3
2.10 -3.36
Ditto but second floor
Along B/n Ax 4 & 5
1 7.55
3.20 24.16
Along B/n Ax 5 & 6
1 7.55
3.20 24.16
Along B/n Ax B & C
1 6.22
3.20 19.90
Along B/n Ax D & E
1 16.12
3.20 51.58
ddt due door
-2 0.80 D3
2.10 -3.36
Ditto but third floor floor
Along B/n Ax 4 & 5
1 7.55
3.20 24.16
Along B/n Ax 5 & 6
1 7.55
3.20 24.16
Along B/n Ax B & C
1 6.22
3.20 19.90
Along B/n Ax D & E
1 16.12
3.20 51.58
ddt due door
-2 0.80 D3
2.10 -3.36
Ditto but fourth floor floor
1 7.55 Along B/n Ax 4 & 5
3.20 24.16
Along B/n Ax 5 & 6
1 7.55
3.20 24.16
Along B/n Ax B & C
1 6.22
3.20 19.90
Along B/n Ax D & E
1 16.12
3.20 51.58
ddt due door
-2 0.80 D3
2.10 -3.36

Ditto but fifth floor floor


1 7.55 Along B/n Ax 4 & 5
3.20 24.16
Along B/n Ax 5 & 6
1 7.55
3.20 24.16
Along B/n Ax B & C
1 6.22
3.20 19.90
Along B/n Ax D & E
1 16.12
3.20 51.58
ddt due door
-2 0.80 D3
2.10 -3.36
Sixth floor
Along B/n Ax 3&4
1 20.18
3.20 64.58
ddt due door
-2 1.60 D6
2.10 -6.72
Along B/n Ax 4&5
1 7.49
3.20 23.97
Along B/n Ax 5&6
1 7.55
3.20 24.16
Along Ax-6
1 1.88
3.20 6.02
Along B/n Ax 6&7
1 11.02
3.20 35.26
ddt due door
-1 1.85 D2
2.10 -3.89
Along B/n Ax B & C
1 6.63
3.20 21.22
Along B/n Ax-D& E
1 11.26
3.20 36.03
ddt due door
-1 1.60 D6
2.10 -3.36
Seventh floor
Along B/n Ax 4&5
1 7.37
3.20 23.58
Along B/n Ax 5&6
1 7.37
3.20 23.58
Along B/n Ax B & C
1 6.63
3.20 21.22
8th floor
Along B/n Ax 3&4
1 10.48
3.20 33.54
ddt due door
-2 1.76 D6
2.10 -7.39
Along B/n Ax 4&5
1 7.37
3.20 23.58
Along B/n Ax 5&6
1 7.37
3.20 23.58
Along B/n Ax 6&7
1 10.44
3.20 33.41
ddt due door
-2 0.90
2.10 -3.78

-1 1.17
3.10 -3.63
Along B/n Ax B & C
1 6.37
3.20 20.38
Along B/n Ax D & E
1 16.28
3.20 52.10
ddt due door
-2 0.80
2.10 -3.36
9th floor
Along B/n Ax 3&4
1 10.48
3.20 33.54
ddt due door
-2 1.76 D6
2.10 -7.39
Along B/n Ax 4&5
1 7.37
3.20 23.58

92
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION
Along B/n Ax 5&6
1 7.37
3.20 23.58
Along B/n Ax 6&7
1 10.44
3.20 33.41
ddt due door
-2 0.90
2.10 -3.78

-1 1.17
3.10 -3.63
Along B/n Ax B & C
1 6.37
3.20 20.38
Along B/n Ax D & E
1 16.28
3.20 52.10
ddt due door
-2 0.80
2.10 -3.36
10th floor
Along B/n Ax 3&4
1 10.48
3.20 33.54
ddt due door
-2 1.76 D6
2.10 -7.39
Along B/n Ax 4&5
1 7.37
3.20 23.58
Along B/n Ax 5&6
1 7.37
3.20 23.58
Along B/n Ax 6&7
1 10.44
3.20 33.41
ddt due door
-2 0.90
2.10 -3.78

-1 1.17
3.10 -3.63
Along B/n Ax B & C
1 6.37
3.20 20.38
Along B/n Ax D & E
1 16.28
3.20 52.10
ddt due door
-2 0.80
2.10 -3.36
11th floor
Along Ax-4
1 6.44
3.20 20.61
ddt due door
-1 0.90 D6
2.10 -1.89
Along B/n Ax 4&5
1 7.37
3.20 23.58
Along B/n Ax 5&6
1 7.37
3.20 23.58
along Ax-6
1 5.50
3.20 17.60
ddt due door
-1 0.90
2.10 -1.89

-1 1.17
3.10 -3.63
Along B/n Ax B & C
1 6.37
3.20 20.38
Along B/n Ax D & E
1 16.28
3.20 52.10
ddt due door
-2 0.80
2.10 -3.36
12th floor
Along B/n Ax-3&4
1 10.87
3.20 34.78
ddt due door
-1 1.50 D12
2.10 -3.15

-2 1.00 D8
2.10 -4.20
Along B/n Ax 4&5
1 7.37
3.20 23.58
Along B/n Ax 5&6
1 7.37
3.20 23.58
Along B/n Ax 6&7
1 17.31
3.20 55.39
Along B/n Ax 7&8
1 17.49
3.20 55.97
ddt due door
-1 0.90
2.10 -1.89

-1 1.80
2.10 -3.78
Along B/n Ax B & C
1 6.37
3.20 20.38
Along Ax-C
1 16.73
3.20 53.54
Along Ax-D
1 18.02
3.20 57.66

93
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION
Along B/n Ax D & E
1 15.23
3.20 48.74
ddt due door
-2 1.45
2.10 -6.09

-1 1.00
2.10 -2.10
Ditto But Roof terrace
Along B/n Ax 3&4
1 7.07
3.20 22.62
Along B/n Ax 4&5
1 3.81
3.20 12.19
Along B/n Ax 5&6
1 3.71
3.20 11.87
ddt due door
-2 0.90 D2
2.10 -3.78
Along B/n Ax 5&6
1 5.52
3.20 17.66
ddt due Window
-1 1.16 W8
1.10 -1.28

-1 1.20 W9
1.10 -1.32
2833.03

150mm thick HCB


First Floor
Along Ax-2
1 3.11
3.20 9.95
Along Ax-3
1 8.46
3.20 27.07
Along Ax-4
1 4.93
3.20 15.78
Along Ax-5
1 5.34
3.20 17.09
Along Ax-6
1 4.89
3.20 15.65
Along Ax-7
1 8.23
3.20 26.34
Along Ax-8
1 2.83
3.20 9.06
2nd floor
Along Ax-2
1 3.18
3.20 10.18
Along Ax-3
1 8.79
3.20 28.13
Along Ax-4
1 5.08
3.20 16.26
Along Ax-5
1 5.42
3.20 17.34
Along Ax-6
1 4.23
3.20 13.54
Along Ax-7
1 8.68
3.20 27.78
Along Ax-8
1 2.88
3.20 9.22
3rd Floor
Along Ax-2
1 3.54
3.20 11.33
Along Ax-3
1 9.98
3.20 31.94
Along Ax-4
1 5.52
3.20 17.66
Along Ax-5
1 5.88
3.20 18.82
Along Ax-6
1 5.45
3.20 17.44
Along Ax-7
1 9.09
3.20 29.09
4th floor
Along Ax-2
1 3.59
3.20 11.49
Along Ax-3
1 5.85
3.20 18.72
Along Ax-4
1 4.01
3.20 12.83
Along Ax-5
1 6.08
3.20 19.46
Along Ax-6
1 5.45
3.20 17.44
Along Ax-7
1 9.21
3.20 29.47
Along Ax-8
1 2.58
3.20 8.26
4th floor
Along Ax-2
1 3.47
3.20 11.10
Along Ax-3
1 10.46
3.20 33.47
Along Ax-4
1 5.82
3.20 18.62
Along Ax-5
1 6.32
3.20 20.22
Along Ax-6
1 5.65
3.20 18.08
Along Ax-7
1 10.06
3.20 32.19
Along Ax-8
1 2.82
3.20 9.02
6th floor
Along Ax-3
1 6.47
3.20 20.70
Along B/n Ax 4&5
1 12.48
3.20 39.94
Along Ax-3
1 5.93
3.20 18.98
ddt due door
-2 0.80
2.10 -3.36
8th floor
Along Ax-4
1 5.60
1.70 9.52
Along Ax-5
94
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION
1 5.96
1.70 10.13
Along Ax-6
1 5.40
1.70 9.18
9th floor
Along Ax-4
1 5.31
1.70 9.03
Along Ax-5
1 5.90
1.70 10.03
Along Ax-6
1 5.17
1.70 8.79
10th floor
Along Ax-4
1 4.86
1.70 8.26
Along Ax-5
1 5.33
1.70 9.06
Along Ax-6
1 4.73
1.70 8.04
11th floor
Along Ax-4
1 4.20
1.70 7.14
Along Ax-5
1 4.65
1.70 7.91
Along Ax-6
1 5.81
1.70 9.88
ddt due door
-2 0.90
2.10 -3.78
12th floor
Along Ax-4
1 3.70
1.70 6.29
Along Ax-5
1 3.78
1.70 6.43
Along Ax-6
1 3.80
1.70 6.46
Along B/n Ax 6 &7
1 2.02
3.20 6.46
ddt due door
-2 0.90
2.10 -3.78
Along B/n B & C
1 2.62
3.20 8.38
Along B/n B & C
1 2.62
3.20 8.38
848.08 M2 total for 150mm thick HCB

95
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION

100mm thick
At ground floor
Along B/n Ax 1& 2
2 1.75
3.20 11.20
Along B/n Ax 3 & 4
1 8.09
3.20 25.89
Along B/n ax 4 & 5
1 4.70
3.20 15.04
ddt due door
-2 0.70
2.10 -2.94

-2 0.80
2.10 -3.36

-2 0.90
2.10 -3.78
Along B/n Ax A & B
3 1.65
3.20 15.84
Along B/n Ax-B & c
1 2.65
3.20 8.48
Along B/n Ax-D & E
1 4.10
3.20 13.12
ddt due door
-2 0.70
2.10 -2.94

-1 0.90
2.10 -1.89
Mezzanine floor
Along B/n Ax 1& 2
2 1.75
3.20 11.20
Along B/n Ax 3 & 4
1 8.06
3.20 25.79
Along B/n Ax 4&5
1 7.46
3.20 23.87
ddt
-2 0.70
2.10 -2.94

-2 0.80
2.10 -3.36

-1 0.90
2.10 -1.89
Along B/n Ax A & B
1 7.51
2.10 15.77
Along B/n Ax D & E
1 4.10
2.10 8.61
ddt
-3 0.70
2.10 -4.41
First to 12 th floor
Along B/n Ax 3&4
12 7.63
3.20 292.99
Along B/n Ax 5 &6
12 7.45
3.20 286.08
ddt
-60 0.70
2.10 -88.20

-12 0.90
2.10 -22.68
Along B/n Ax 6&7
12 8.07
3.20 309.89
Along B/n Ax A & B
12 13.01
3.20 499.58
Along B/n Ax B & c
12 5.11
3.20 196.22
1621.19 M2 total for 150mm thick HCB

Light Weight Concrete


1 694.11 694.11
694.11

Cement screed
1 694.11 694.11
694.11

Water Proofing Material


1 694.11 694.11
694.11

4. Carpantary and Joinary


Wooden Door
At basment floor
4 1.00 4.00 TypeD 1 Size 700x2100mm

At Ground floor
7 1.00 7.00 TypeD 1 Size 700x2100mm
3 1.00 3.00 TypeD 1 Size 800x2100mm

At 1st floor & 4th floor floor


18 1.00 18.00 TypeD 1 Size 700x2100mm
6 1.00 6.00 TypeD 1 Size 800x2100mm
8 1.00 8.00 TypeD 1 Size 900x2100mm
2 1.00 2.00 TypeD 1 Size 1000x2100mm
2 1.00 2.00 TypeD 1 Size 1500x2100mm

At 2nd floor & 3rd floor floor


14 1.00 14.00 TypeD 1 Size 700x2100mm

Roof Slab
2 1.00 2.00 TypeD 1 Size 700x2100mm
1 1.00 1.00 TypeD 1 Size 800x2100mm

Partion Wall
Ground Floor
PW1
1 2.03
3.60 7.31
PW2
1 7.50
3.60 27.00
Mezzanine Floor
PW1
1 2.03
3.60 7.31
PW2
1 7.50
3.60 27.00
First floor to Fifth floor
PW1
5 10.50
3.60 189.00
PW2
5 5.50
3.60 99.00
PW4
5 5.90
3.60 106.20
PW6
5 5.80
3.60 104.40
PW8
5 5.50
3.60 99.00
PW10
5 10.60
3.60 190.80

96
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION
7th to 11th floor
PW1''
5 4.23
3.60 76.14
PW2
5 4.70
3.60 84.60
PW3
5 4.75
3.60 85.50
PW4'
5 5.43
3.60 97.74
PW6
5 10.66
3.60 191.88
PW7'
5 3.90
3.60 70.20
PW8
5 1.88
3.60 33.84
PW15
5 5.69
3.60 102.42
PW17
5 4.85
3.60 87.30
PW18&PW19
5 9.46
3.60 170.28
PW23
5 10.56
3.60 190.08
PW27
5 4.23
3.60 76.14
PW28
5 4.66
3.60 83.88
PW29
5 4.57
3.60 82.26
2289.28

97
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION

5. Metal work
Aluminum Frame window
At basment floor
1 1.00 1.00 Type W1 Size 2750x1500mm
1 1.00 1.00 Type W2 Size 3150x1500mm
1 1.00 1.00 Type W3 Size 4150x1500mm
4 1.00 4.00 Type W4 Size 4700x1500mm
3 1.00 3.00 Type W5 Size 5000x2100mm

At Ground floor
2 1.00 2.00 Type W1 Size 500x3080mm
14 1.00 14.00 Type W2 Size 1000x1900mm
2 1.00 2.00 Type W2 Size 1000x3080mm
2 1.00 2.00 Type W3 Size 1100x1900mm
2 1.00 2.00 Type W3 Size 2600x3080mm
1 1.00 1.00 Type W3 Size 3100x800mm

At first & Fourth floor


2 1.00 2.00 Type W1 Size 700x3080mm
2 1.00 2.00 Type W2 Size 1000x800mm
16 1.00 16.00 Type W2 Size 1000x1900mm
4 1.00 4.00 Type W2 Size 1000x3080mm
2 1.00 2.00 Type W3 Size 1200x800mm
2 1.00 2.00 Type W3 Size 1500x1900mm
2 1.00 2.00 Type W3 Size 2000x1900mm
4 1.00 4.00 Type W3 Size 2600x3080mm

At 2nd & 3rd floor


2 1.00 2.00 Type W1 Size 700x3080mm
2 1.00 2.00 Type W2 Size 1000x800mm
14 1.00 14.00 Type W2 Size 1000x1900mm
4 1.00 4.00 Type W2 Size 1000x3080mm
2 1.00 2.00 Type W3 Size 1200x800mm
2 1.00 2.00 Type W3 Size 1500x1900mm
2 1.00 2.00 Type W3 Size 2000x1900mm
4 1.00 4.00 Type W3 Size 2600x3080mm

At Terrace Roof
1 1.00 1.00 Type W2 Size 1000x800mm
1 1.00 1.00 Type W2 Size 1000x1900mm
2 1.00 2.00 Type W2 Size 1000x3080mm
2 1.00 2.00 Type W3 Size 1200x800mm

Aluminum frame door


Basment
4 1.00 4.00 Type D1 Size 1500x2600mm

ground floor
1 1.00 1.00 Type D1 Size 900x2600mm

first to Fourth floor


4 1.00 4.00 Type D1 Size 700x2600mm

Roof Slab
4 1.00 4.00 Type D1 Size 1200x3080mm

98
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION
Aluminum Window door frame
ground floor
1 1.00 1.00 Type WD2 Size3600x3080mm

For first & Fourth


2 1.00 2.00 Type WD1 Size1500x3080mm
2 1.00 2.00 Type WD2 Size3600x3080mm

For 2nd & 3rd floor


4 1.00 4.00 Type WD1 Size1500x3080mm
2 1.00 2.00 Type WD2 Size3600x3080mm

Roof Slab
1 1.00 1.00 Type WD2 Size3600x3080mm

Curtain Wall
CW1
From Ground Floor to 12th floor
52 2.30
3.60 430.56
CW2
Ground Floor
1 2.92
3.60 10.51
Mezanine floor
1 6.99
3.60 25.16
CW3
1 5.80
3.60 20.88
487.12

Glass Block
Ground floor
4 4.00 4.00 (550X 330)
0.00 mezzanine floor
4 4.00 4.00 (550X 330)
8.00

Wall Mounted
Stair 1
15 7.48 112.20 From Ground to Terrace floor
Stair 2
14 7.48 104.72 From Ground to Terrace floor
216.92 ml total

hand rail for stair case


Stair 1
18 7.48 134.64 From Basmenet to Terrace floor
Stair 2
17 7.48 127.16 From Basmenet to Terrace floor
261.80 ml total

Guard rail
Mezzanine floor
1 13.39 13.39 From Basmenet to Terrace floor
11th floor
1 12.85 12.85 From Basmenet to Terrace floor
26.24 ml total

99
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION
6.Plastering and pointing
Three Coat plastering
a) External Wall
663.23 663.23 The same area with the area of external wall
663.23 Refer item no 2a

Internal Wall
For third basement
Along ax-03
1 3.32
2.70 8.96
Along Ax-4
1 2.50
2.70 6.75
Along Ax-6
1 4.91
2.70 13.26
Along B/n Ax 6 & 7
1 4.04
2.70 10.91
Along Ax-7
1 4.91
2.70 13.26
ddt due door
-1 0.80
2.10 -1.68
Along B/n Ax-A&B
1 9.50
2.70 25.65
ddt due door
-2 0.80
2.10 -3.36
Along Ax-B
1 22.00
2.70 59.40
Along Ax-C& D
2 2.00
2.70 10.80
For second Basment
Along ax-03
1 3.37
2.70 9.10
Along Ax-4
1 4.41
2.70 11.91
Along Ax-6
1 4.41
2.70 11.91
Along B/n Ax 6 & 7
1 4.34
2.70 11.72
Along Ax-7
1 4.45
2.70 12.02
ddt due door
-1 0.80
2.10 -1.68
Along B/n Ax-A&B
1 9.50
2.70 25.65
ddt due door
-1 0.80
2.10 -1.68
Along Ax-B
1 22.00
2.70 59.40
Along Ax-C& D
2 2.00
2.70 10.80
For First Basment
Along ax-03
1 3.37
2.70 9.10
Along Ax-4
1 2.45
2.70 6.62
Along Ax-6
1 4.43
2.70 11.96
Along B/n Ax 6 & 7
1 4.34
2.70 11.72
Along Ax-7
1 4.50
2.70 12.15
ddt due door
-1 0.80
2.10 -1.68
Along B/n Ax-A&B
1 3.50
2.70 9.45
ddt due door
-1 0.80
2.10 -1.68
Along Ax-B
1 22.00
2.70 59.40
Along Ax-C& D
2 2.00
2.70 10.80
420.92
841.83 841.83

Column & Shear Wall Plastering


3rd Basment
External
29 0.50 Column
3.20 46.40

1 5.20 shear Wall


3.20 16.64
2nd Basment
External
29 0.50 Column
3.20 46.40

1 5.20 shear Wall


3.20 16.64
1st Basment
External
29 0.50 Column
3.20 46.40

1 5.20 shear Wall


3.20 16.64
Ground floor
14 0.50
3.20 22.40

12 0.79
3.20 30.14

2 0.30
3.20 1.92
Mezzanine floor
14 0.50
3.20 22.40

12 0.79
3.20 30.14

2 0.30
3.20 1.92

First to 6 th floor
6 1.50
3.20 28.80
Shera wall
roof slab
1 1.90
3.20 6.08
332.93

100
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION
Internal
3rd Basment
70 0.50 Column
3.20 112.00

20 0.50
3.20 32.00
ShearWall
1 58.19 L=2*3.05+2*.7+1.4+3*2*3.2+3*2*.20+2*5.18+2*1.44+6.17+3.97+1+2.85+0.83+0.83=58.19
3.20 186.21
2nd Basment
70 0.50 Column
3.20 112.00

20 0.50
3.20 32.00
ShearWall
1 58.19 L=2*3.05+2*.7+1.4+3*2*3.2+3*2*.20+2*5.18+2*1.44+6.17+3.97+1+2.85+0.83+0.83=58.19
3.20 186.21
1st basment
70 0.50 Column
3.20 112.00

20 0.50
3.20 32.00
ShearWall
1 58.19 L=2*3.05+2*.7+1.4+3*2*3.2+3*2*.20+2*5.18+2*1.44+6.17+3.97+1+2.85+0.83+0.83=58.19
3.20 186.21
990.62
1323.55

101
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION
Soffit of Stair Case & Landing
Stair 1
66 1.10
0.34 24.68
Landing Area
3 2.65
2.70 21.47
Stair 2
66 1.10
0.34 24.68
Landing Area
3 2.65
2.70 21.47
Soffit Of Slab
For 1st & Second basment
2 28.31 External
47.40 2683.79 Column
ddt due Stair case
Stair 1
-2 33.89 -67.78
Stair 2

102
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION
-2 39.18 -78.36
Ramp
-2 143.74 -287.48
For Ground floor Slab
1 28.31 0.00
47.40 1341.89
ddt due Stair case
Stair 1
-1 33.89 -33.89
Stair 2
-1 39.18 -39.18
Ramp
-1 143.74 -143.74
3375.25

103
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION
c) Column and Shear Wall
Internal
i) Column ,beam
First to Roof Slab
18 0.50
3.20 28.80

4 0.20
3.20 2.51
Shear Wall
First to 12th floor
12 27.79 Wall 3
3.20 1067.14
Wall 4
12 19.32
3.20 741.89
Lift Shaft Shear Wall
12 2.80
3.20 107.52
1947.86 m2 Total

Two Coat Plastering Ceiling


Under side of staircase
Stair 1
308 1.10
0.34 115.19
Stair 2
286 1.10
0.34 106.96
115.19 m2 total

104
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION

105
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION

7. Floor Finish
7.1 Ceramic Floor tile
At third basment
1 2.65 Fresh Air Supply
5.80 15.37

1 5.65
2.75 15.54

1 2.60 Store
3.44 8.94

1 4.93
3.56 17.55

1 4.91
5.50 27.01
Corridor Infront of Store & Corridor
1 2.11
14.34 30.26
At Second Basment
Store
1 2.55
3.44 8.77

1 4.93
3.56 17.55

1 4.91
5.50 27.01
Corridor Infront of Store & Corridor
1 2.11
8.55 18.04
At First Basment
Store
1 2.55
3.44 8.77

1 4.93
3.56 17.55

1 4.91
5.50 27.01
Corridor Infront of Store & Corridor
1 2.11
8.55 18.04
Electric Room
1 5.70
5.75 32.78
Ground floor
1 3.86 Toilet
1.65 6.37
Janitor
1 1.80
1.65 2.97
Store
1 1.96
1.64 3.21
Toilet Corridor
1 5.97
1.85 11.04

1 2.35
1.02 2.40
Toilet
1 2.35
4.08 9.59

1 3.86
1.75 6.76
First floor
1 3.86 Toilet
1.65 6.37
Janitor
1 1.80
1.65 2.97
Store
1 1.96
1.64 3.21
Toilet Corridor
1 5.97
1.85 11.04

1 2.35
1.02 2.40
Toilet
1 2.35
4.08 9.59

1 3.86
1.75 6.76
At Second floor
1 0.80 Ladies toilet
1.60 1.28

1 1.80
1.60 2.88

1 1.76
1.60 2.82

1 1.21
1.60 1.94
Toilet Corridor
1 5.97
1.90 11.34

1 2.35
1.05 2.47
kitchenet
1 1.96
1.65 3.23
Gentle toilet
1 0.80
1.60 1.28

1 1.80
1.60 2.88

1 1.76
1.60 2.82

1 1.21
1.60 1.94
Toilet Corridor
1 5.97
1.90 11.34

1 2.35
1.05 2.47
Janitor
1 1.96
1.50 2.94
At third floor
1 0.80 Ladies toilet
1.60 1.28

1 1.80
1.60 2.88

1 1.76
1.60 2.82

1 1.21
1.60 1.94
Toilet Corridor
1 5.97
1.90 11.34

1 2.35
1.05 2.47
kitchenet
106
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION
1 1.96
1.65 3.23
Gentle toilet
1 0.80
1.60 1.28

1 1.80
1.60 2.88

1 1.76
1.60 2.82

1 1.21
1.60 1.94
Toilet Corridor
1 5.97
1.90 11.34

1 2.35
1.05 2.47
Janitor
1 1.96
1.50 2.94
At fourth floor
1 0.80 Ladies toilet
1.60 1.28

1 1.80
1.60 2.88

1 1.76
1.60 2.82

1 1.21
1.60 1.94
Toilet Corridor
1 5.97
1.90 11.34

1 2.35
1.05 2.47
kitchenet
1 1.96
1.65 3.23
Gentle toilet
1 0.80
1.60 1.28

1 1.80
1.60 2.88

1 1.76
1.60 2.82

1 1.21
1.60 1.94
Toilet Corridor
1 5.97
1.90 11.34

1 2.35
1.05 2.47
Janitor
1 1.96
1.50 2.94
At fifth floor
1 0.80 Ladies toilet
1.60 1.28

1 1.80
1.60 2.88

1 1.76
1.60 2.82

1 1.21
1.60 1.94
Toilet Corridor
1 5.97
1.90 11.34

1 2.35
1.05 2.47
kitchenet
1 1.96
1.65 3.23
Gentle toilet
1 0.80
1.60 1.28

1 1.80
1.60 2.88

1 1.76
1.60 2.82

1 1.21
1.60 1.94
Toilet Corridor
1 5.97
1.90 11.34

1 2.35
1.05 2.47
Janitor
1 1.96
1.50 2.94
At Sixth floor
1 0.80 Ladies toilet
1.60 1.28

1 1.80
1.60 2.88

1 1.76
1.60 2.82

1 1.21
1.60 1.94
Toilet Corridor
1 5.97
1.90 11.34

1 2.35
1.05 2.47
kitchenet
1 1.96
1.65 3.23
Gentle toilet
1 0.80
1.60 1.28

1 1.80
1.60 2.88

1 1.76
1.60 2.82

1 1.21
1.60 1.94
Toilet Corridor
1 5.97
1.90 11.34

1 2.35
1.05 2.47
Janitor
1 1.96
1.50 2.94
At seventh floor
1 0.80 Ladies toilet

107
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION
1.60 1.28

1 1.80
1.60 2.88

1 1.76
1.60 2.82

1 1.21
1.60 1.94
Toilet Corridor
1 5.97
1.90 11.34

1 2.35
1.05 2.47
kitchenet
1 1.96
1.65 3.23
Gentle toilet
1 0.80
1.60 1.28

1 1.80
1.60 2.88

1 1.76
1.60 2.82

1 1.21
1.60 1.94
Toilet Corridor
1 5.97
1.90 11.34

1 2.35
1.05 2.47
Janitor
1 1.96
1.50 2.94
At Eigth floor
1 0.80 Ladies toilet
1.60 1.28

1 1.80
1.60 2.88

1 1.76
1.60 2.82

1 1.21
1.60 1.94
Toilet Corridor
1 5.97
1.90 11.34

1 2.35
1.05 2.47
kitchenet
1 1.96
1.65 3.23
Gentle toilet
1 0.80
1.60 1.28

1 1.80
1.60 2.88

1 1.76
1.60 2.82

1 1.21
1.60 1.94
Toilet Corridor
1 5.97
1.90 11.34

1 2.35
1.05 2.47
Janitor
1 1.96
1.50 2.94
At 9th floor
1 0.80 Ladies toilet
1.60 1.28

1 1.80
1.60 2.88

1 1.76
1.60 2.82

1 1.21
1.60 1.94
Toilet Corridor
1 5.97
1.90 11.34

1 2.35
1.05 2.47
kitchenet
1 1.96
1.65 3.23
Gentle toilet
1 0.80
1.60 1.28

1 1.80
1.60 2.88

1 1.76
1.60 2.82

1 1.21
1.60 1.94
Toilet Corridor
1 5.97
1.90 11.34

1 2.35
1.05 2.47
Janitor
1 1.96
1.50 2.94
At 10th floor
1 0.80 Ladies toilet
1.60 1.28

1 1.80
1.60 2.88

1 1.76
1.60 2.82

1 1.21
1.60 1.94
Toilet Corridor
1 5.97
1.90 11.34

1 2.35
1.05 2.47
kitchenet
1 1.96
1.65 3.23
Gentle toilet
1 0.80
1.60 1.28

1 1.80
1.60 2.88

108
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION
1 1.76
1.60 2.82

1 1.21
1.60 1.94
Toilet Corridor
1 5.97
1.90 11.34

1 2.35
1.05 2.47
Janitor
1 1.96
1.50 2.94
At 11th floor
1 0.80 Ladies toilet
1.60 1.28

1 1.80
1.60 2.88

1 1.76
1.60 2.82

1 1.21
1.60 1.94
Toilet Corridor
1 5.97
1.90 11.34

1 2.35
1.05 2.47
kitchenet
1 1.96
1.65 3.23
Gentle toilet
1 0.80
1.60 1.28

1 1.80
1.60 2.88

1 1.76
1.60 2.82

1 1.21
1.60 1.94
Toilet Corridor
1 5.97
1.90 11.34

1 2.35
1.05 2.47
Janitor
1 1.96
1.50 2.94
At 12th floor
1 0.80 Ladies toilet
1.60 1.28

1 1.80
1.60 2.88

1 1.76
1.60 2.82

1 1.21
1.60 1.94
Toilet Corridor
1 5.97
1.90 11.34

1 2.35
1.05 2.47
kitchenet
1 1.96
1.65 3.23
Gentle toilet
1 0.80
1.60 1.28

1 1.80
1.60 2.88

1 1.76
1.60 2.82

1 1.21
1.60 1.94
Toilet Corridor
1 5.97
1.90 11.34

1 2.35
1.05 2.47
Janitor
1 1.96
1.50 2.94
Roof Slab
ladies /toilet
1 1.76
3.70 6.51
gentle/toilet
1 1.76
3.70 6.51
955.69 m2 Total for item no 7.4

7.20 porcelain tile


For Ground floor
Secretary
1 24.70 24.70
Manager office
1 34.20 34.20
office pool
1 291.00 291.00
Security room
1 54.02 54.02
Serer room
1 45.20 45.20
Waiting Area
1 75.40 75.40
Mezzanine Floor
office pool
1 159.10 159.10
Secretary
1 24.70 24.70
Manager office
1 34.20 34.20

109
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION
First floor
office pool
1 252.60 252.60
Manager office
1 21.50 21.50
Secretary
1 57.30 57.30
Archie
1 45.10 45.10
mine confrence room
1 45.20 45.20
Secretary
1 8.70 8.70
Manager office
1 21.50 21.50
office pool
1 290.20 290.20
2nd floor
office pool
1 252.60 252.60
Secretary
1 24.70 24.70
Manager office
2 21.50 43.00
Secretary
2 8.70 17.40
Archive
1 45.10 45.10
mini Confrence
1 45.20 45.20
office pool
1 248.90 248.90
office pool
2 23.90 47.80
3rd floor
office pool
1 299.70 299.70
Secretary
2 8.70 17.40

1 24.70 24.70
Manager office
2 24.60 49.20

1 27.80 27.80
Archive
1 48.20 48.20
mini Confrence
1 48.30 48.30
office pool
1 261.90 261.90

1 23.90 23.90
Secretary
1 17.40 17.40
4th floor
office pool
1 299.70 299.70
Secretary
2 8.70 17.40
Manager office
2 24.64 49.28
Secretary
1 24.70 24.70

1 27.80 27.80
Archive
1 48.20 48.20
mini Confrence
1 48.30 48.30
office pool
1 261.90 261.90

1 23.90 23.90
5th floor
office pool
1 299.70 299.70
Secretary
2 8.70 17.40
Manager office
2 24.60 49.20
Secretary
1 24.70 24.70

1 27.80 27.80
Archive
1 48.20 48.20
mini Confrence
1 48.30 48.30
office pool
1 261.90 261.90

1 23.90 23.90
Secretary
1 17.40 17.40
6th floor
Lounge for MPH
1 74.00 74.00
Cold room
1 7.90 7.90
kitchen
1 50.80 50.80
Counter
1 22.15 22.15
Cafteria
1 334.00 334.00
Copy room
1 13.60 13.60
7th floor
Logistics pool
1 262.20 262.20
Transport manager
1 24.40 24.40
Extra Office
1 50.80 50.80
Logistics coordinator
1 30.10 30.10
Secretary
1 8.00 8.00
Archie
1 45.10 45.10
Mine confrence rm
1 45.20 45.20
Customer coordinater
1 24.40 24.40
Extra office
1 24.40 24.40
Customer services
1 241.20 241.20
Secretary
1 15.30 15.30
Transport Manager
1 21.40 21.40
8th floor
Logistic pool
1 244.60 244.60
Transport manager
1 21.90 21.90
Secretary
1 15.30 15.30
Extra Office
1 23.10 23.10
Logistics Coordinator
1 28.70 28.70
Secretary
1 8.00 8.00
Archive
1 46.10 46.10
Mine confrence RM
1 15.20 15.20
Secretary
1 8.00 8.00

110
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION
Customer coordinator
1 28.10 28.10
Extra office
1 23.00 23.00
Customer waiting Area
1 232.10 232.10
Logistics Manager
1 20.00 20.00
9th floor
Logistic pool
1 232.50 232.50
Admin Assistance
1 19.20 19.20
Secretary
1 15.30 15.30
Extra Office
1 21.00 21.00
Faculity maintenace
1 27.00 27.00
Secretary
1 8.00 8.00
Archive
1 45.10 45.10
Mine confrence RM
1 45.20 45.20
Secretary
1 8.00 8.00
Engineering manager
1 26.70 26.70
Extra office
1 21.00 21.00
operation Assistants
1 221.20 221.20
operation manager
1 19.30 19.30
Secretary
1 17.40 17.40
10th floor
Logistic pool
1 232.50 232.50
Com sales man
1 16.60 16.60
Secretary
1 15.30 15.30
Extra Office
1 18.50 18.50
Commericial man
1 24.10 24.10
Secretary
1 8.00 8.00
Archive
1 45.10 45.10
Mine confrence RM
1 45.20 45.20
Secretary
1 8.00 8.00
Commerical sales man
1 24.10 24.10
Extra office
1 18.60 18.60
Bitumen and special products
1 206.70 206.70
Manager office
1 16.60 16.60
Secretary
1 17.40 17.40
11th floor
offic pool
1 191.60 191.60
Extra office
1 15.90 15.90
Aduit manger
1 22.50 22.50
Extra Office
1 14.20 14.20
Adminstratie Assistance
1 17.87 17.87
Secretary
1 15.30 15.30
Archive
1 45.10 45.10
Mine confrence RM
1 41.50 41.50
Secretary
1 8.00 8.00
LUM
1 22.70 22.70
HRM
1 15.90 15.90
office pool
1 140.60 140.60
BDM
1 19.10 19.10
Secretary
1 17.40 17.40
11th floor
offic pool
1 191.60 191.60
Extra office
1 15.90 15.90
Aduit manger
1 22.50 22.50
Extra Office
1 14.20 14.20
Adminstratie Assistance
1 17.87 17.87
Secretary
1 15.30 15.30
Archive
1 45.10 45.10
Mine confrence RM
1 41.50 41.50
Secretary
1 8.00 8.00
LUM
1 22.70 22.70
HRM
1 15.90 15.90
office pool
1 140.60 140.60
BDM
1 19.10 19.10
Secretary
1 17.40 17.40
12th floor
Extra office
2 73.50 147.00
Secretary
1 15.90 15.90

1 17.30 17.30
Archive
1 45.10 45.10
Mine confernce RM
1 41.50 41.50
Waiting Area
1 71.10 71.10
CEO
1 45.00 45.00
Dressing room
1 18.50 18.50
GYM
1 28.00 28.00
meeting room
1 86.60 86.60
Rooof Terrace
outdoor service
1 167.60 167.60
Entertment desk and lounge
1 221.72 221.72
Store
1 9.10 9.10

1 4.62 4.62
10174.53 m2 Total for

111
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION

7.1 Granite floor tile


Ground floor
Lobby & Securti entrance
1 240.74 240.74
1 8.22 8.22 In B/n Staircase
First floor
1 92.01 92.01 Corridor
1 38.89 38.89 lift lobby
1 8.22 8.22 In B/n Staircase

Second floor
1 92.01 92.01 Corridor
1 38.89 38.89 lift lobby
1 8.22 8.22 In B/n Staircase

Third floor
1 92.01 92.01 Corridor
1 38.89 38.89 lift lobby
1 8.22 8.22 In B/n Staircase

Fourth floor
1 92.01 92.01 Corridor
1 38.89 38.89 lift lobby
1 8.22 8.22 In B/n Staircase

Fifth floor
1 92.01 92.01 Corridor
1 38.89 38.89 lift lobby
1 8.22 8.22 In B/n Staircase

Sixth floor
1 92.01 92.01 Corridor
1 38.89 38.89 lift lobby
1 8.22 8.22 In B/n Staircase

Seventh floor
1 92.01 92.01 Corridor
1 38.89 38.89 lift lobby
1 8.22 8.22 In B/n Staircase

8th floor
1 92.01 92.01 Corridor
1 38.89 38.89 lift lobby
1 8.22 8.22 In B/n Staircase

9th floor
1 92.01 92.01 Corridor
1 38.89 38.89 lift lobby
1 8.22 8.22 In B/n Staircase

10th floor
1 92.01 92.01 Corridor
1 38.89 38.89 lift lobby
1 8.22 8.22 In B/n Staircase

11th floor
1 92.01 92.01 Corridor
1 38.89 38.89 lift lobby
1 8.22 8.22 In B/n Staircase

12th floor
1 92.01 92.01 Corridor
1 38.89 38.89 lift lobby
1 8.22 8.22 In B/n Staircase
1918.44

7.1 Poly floor


6th floor
Lobby & Securti entrance
1 298.30 298.30
298.30

7.3 Skirting
7.1 Ceramic Floor tile
Ground floor
janitor
1 6.02 6.02
Store
1 6.40 6.40
First floor
kitchenate
1 2.81 2.81
second floor
kitchenate
1 2.81 2.81
Third floor
kitchenate
1 2.81 2.81
Fourth floor
kitchenate
1 2.81 2.81
Fifth floor
kitchenate
1 2.81 2.81
6th floor
kitchenate
1 2.81 2.81
7th floor
kitchenate
1 2.81 2.81
8th floor
kitchenate
1 2.81 2.81
9th floor
kitchenate
1 2.81 2.81
10th floor
kitchenate
1 2.81 2.81
11th floor
kitchenate
1 2.81 2.81
12th floor
kitchenate
1 2.81 2.81
46.14 Ml Total for item

7.20 porcline skirting


third floor Basment
Fresh Air Supply
1 16.10 16.10
Store
1 11.28 11.28
Store
1 16.16 16.16
Store
1 20.04 20.04
Fresh Air Supply
1 16.02 16.02
Corridor
1 24.72 24.72
second Basment
Store
1 11.28 11.28
Store
1 16.16 16.16
Store
1 20.04 20.04
Corridor
1 20.03 20.03
First Basment
Store
1 11.28 11.28
Store
1 16.16 16.16
Store
1 20.04 20.04
Corridor
1 20.03 20.03
Ground floor
Security room
1 13.30 13.30
Server room
1 20.31 20.31
office pool
1 7.44 7.44

112
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION
Secretary
1 4.33 4.33
Manager office
1 12.17 12.17
Waiting Area
1 32.33 32.33
office pool
1 37.85 37.85
mezzanine floor
office pool
1 65.81 65.81
First floor
Manager office
1 3.67 3.67
Archive
1 20.71 20.71
mini Confrence
1 20.73 20.73
Secretary
1 6.28 6.28

1 3.80 3.80
office pool
1 22.10 22.10
office pool
1 22.92 22.92
Secretary
1 12.33 12.33
Manager office
1 8.08 8.08
Second floor
Manager office
1 3.67 3.67
Archive
1 20.71 20.71
mini Confrence
1 20.73 20.73
Secretary
1 6.28 6.28

1 3.80 3.80
office pool
1 22.10 22.10
office pool
1 22.92 22.92
Secretary
1 12.33 12.33
Manager office
1 8.08 8.08
third floor
Manager office
1 3.67 3.67
Archive
1 20.71 20.71
mini Confrence
1 20.73 20.73
Secretary
1 6.28 6.28

1 3.80 3.80
office pool
1 22.10 22.10
office pool
1 22.92 22.92
Secretary
1 12.33 12.33
Manager office
1 8.08 8.08
Fourth floor
Manager office
1 3.67 3.67
Archive
1 20.71 20.71
mini Confrence
1 20.73 20.73
Secretary
1 6.28 6.28

1 3.80 3.80
office pool
1 22.10 22.10
office pool
1 22.92 22.92
Secretary
1 12.33 12.33
Manager office
1 8.08 8.08
Fifth floor
Manager office
1 3.67 3.67
Archive
1 20.71 20.71
mini Confrence
1 20.73 20.73
Secretary
1 6.28 6.28

1 3.80 3.80
office pool
1 22.10 22.10
office pool
1 22.92 22.92
Secretary
1 12.33 12.33
Manager office
1 8.08 8.08
Sixth floor
Copy room
1 8.53 8.53
Lounge
1 24.61 24.61
Cafteria
1 32.09 32.09
Transport team
1 32.09 32.09
Seventh floor
Logistic pool
1 13.16 13.16
Extra office
1 2.01 2.01
logistic coordinater
1 4.43 4.43
Archieve
1 6.83 6.83
Mini Confrence
1 3.67 3.67
customer coordinater
1 4.70 4.70
Extra office
1 2.25 2.25
Custumer waiting Area
1 14.33 14.33
logstic & cs man
1 1.00 1.00
Secretary
1 0.90 0.90
Transport manager
1 2.01 2.01
8th floor
Logistic pool
1 20.78 20.78
Extra office
1 2.01 2.01
logistic coordinater
1 4.43 4.43
Archieve
1 6.83 6.83
Mini Confrence
1 3.67 3.67
customer coordinater
1 4.70 4.70
Extra office
1 2.25 2.25
113
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION
Custumer waiting Area
1 21.98 21.98
logstic & cs man
1 1.00 1.00
Secretary
1 0.90 0.90
Transport manager
1 2.01 2.01
9th floor
Logistic pool
1 20.78 20.78
Extra office
1 2.01 2.01
logistic coordinater
1 4.43 4.43
Archieve
1 6.83 6.83
Mini Confrence
1 3.67 3.67
customer coordinater
1 4.70 4.70
Extra office
1 2.25 2.25
Custumer waiting Area
1 21.98 21.98
logstic & cs man
1 1.00 1.00
Secretary
1 0.90 0.90
Transport manager
1 2.01 2.01
10th floor
Logistic pool
1 20.78 20.78
Extra office
1 2.01 2.01
logistic coordinater
1 4.43 4.43
Archieve
1 6.83 6.83
Mini Confrence
1 3.67 3.67
customer coordinater
1 4.70 4.70
Extra office
1 2.25 2.25
Custumer waiting Area
1 21.98 21.98
logstic & cs man
1 1.00 1.00
Secretary
1 0.90 0.90
Transport manager
1 2.01 2.01
11th floor
office pool
1 9.88 9.88
Aduit manager
1 0.92 0.92
Archieve
1 16.35 16.35
Mini Confrence
1 19.40 19.40
lum
1 5.20 5.20
HRM
1 1.14 1.14
office pool
1 16.80 16.80
BDM
1 1.11 1.11
Secretary
1 1.11 1.11
Administration
1 1.06 1.06
12th floor
Meeting room
1 34.10 34.10
Extra office & secratory
1 42.24 42.24
Archieve
1 17.45 17.45
Mini Confrence
1 17.44 17.44
Secretary
1 17.87 17.87
Waiting Area
1 13.45 13.45
CEO
1 21.69 21.69
Dressing room
1 10.65 10.65
GYM
1 13.01 13.01
lobby
1 15.39 15.39
Waiting Area
1 7.02 7.02
Roof terrace
outdoor seating
1 9.42 9.42
Extra office & secratory
1 16.19 16.19
Entretment desk
1 20.33 20.33
1729.54 m1 Total for

7.20 Granite floor


Ground Floor
Lift Lobby
1 11.94 11.94
Information desk
1 29.44 29.44
Mezanine
Fire exit
1 24.51 24.51
First floor
1 23.31 23.31 Corridor & fire Exit
Second floor
1 23.31 23.31 Corridor & fire Exit
Third floor
1 21.02 21.02 Corridor & fire Exit
Fourth floor
1 21.02 21.02 Corridor & fire Exit
Fifth floor
1 21.02 21.02 Corridor & fire Exit
sixth floor
1 31.03 31.03 Corridor & fire Exit
seventh floor
1 8.73 8.73 Corridor & fire Exit
8th floor
1 38.22 38.22 Corridor & fire Exit
9th floor
1 38.22 38.22 Corridor & fire Exit
10th floor
1 38.22 38.22 Corridor & fire Exit
11th floor
1 17.49 17.49 Corridor & fire Exit
12th floor
1 35.25 35.25 Corridor & fire Exit
382.73

poly floor skrting


23.44 23.44
23.44

Tread
Stair 1
From 3rd basment To roof
360 1.10 396.00
Stair 2
From 3rd basment To roof
340 1.10 374.00
770.00
114
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION

riser
Stair 1
From 3rd basment To roof
396 1.10 435.60
Stair 2
From 3rd basment To roof
374 1.10 411.40
847.00

Skrting
Stair 1
From 3rd basment To roof
396 0.34 134.64
Stair 2
From 3rd basment To roof
374 0.34 127.16
261.80

Landing
Stair 1
From 3rd basment To roof
18 2.65
2.42 115.43
Stair 2
From 3rd basment To roof
17 2.65
2.42 109.02
224.46

Granite Wall Cladding


Wall 3
1 40.74
62.06 2528.32
lift shaft Wall
1 5.06
62.06 314.02
2842.35

Epoxy for ramp


150mm thick Ramp
From Ground to First Basment
1 18.43
6.60 121.62
From First to Second Basment
1 18.43
6.60 121.62
From second to third Basment
1 18.43
6.60 121.62
364.85 m2 Total

Epoxy for basment floor


3rd Bsament
1 1055.54 1055.54
2nd Bsament
1 1005.96 1005.96
1st Bsament
1 1005.96 1005.96
3067.46 m2 Total

veniy
Ground floor
Toilet
2 1.18
1.70 4.01

1 1.50
1.70 2.55
Toilet corridor
1 5.97
1.85 11.04

1 2.37
1.02 2.42
Toilet
2 1.18
1.75 4.13

1 1.50
1.75 2.63
Toilet corridor
1 2.35
4.08 9.59
Mezzanine floor
Toilet
2 1.18
1.70 4.01

1 1.50
1.70 2.55
Toilet corridor
1 5.97
1.85 11.04

1 2.37
1.02 2.42
Toilet
2 1.18
1.75 4.13

1 1.50
1.75 2.63
Toilet corridor
1 2.35
4.08 9.59
First to fifth floor
Ladies toilet
5 0.80
1.70 6.80

10 0.90
1.70 15.30

5 1.76
1.70 14.96

5 1.21
1.70 10.29
Toilet corridor
5 5.97
1.90 56.72

5 2.33
1.06 12.35
Gentle toilet
5 0.80
1.70 6.80

10 0.90
1.70 15.30

5 1.76
1.70 14.96

5 1.21
1.70 10.29
Toilet corridor
5 5.97
1.90 56.72

5 2.33
1.06 12.35
6th to 12th floor
Ladies toilet
7 0.80
0 1.70 9.52
0
14 0.90
0 1.70 21.42
0
7 1.76
0 1.70 20.94
0
7 1.21
0 1.70 14.40
0 Toilet corridor
7 5.97
0 1.90 79.40

115
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION
0
7 2.33
0 1.06 17.29
0 Gentle toilet
7 0.80
0 1.70 9.52
0
14 0.90
0 1.70 21.42
0
7 1.76
0 1.70 20.94
0
7 1.21
0 1.70 14.40
0 Toilet corridor
14 5.97
0 1.90 158.80
0
7 2.33
0 1.06 17.29
0 kitchenette
7 1.98
0 1.65 22.87
kitchen
1 50.80 50.80
Roof
Ladies toilet
1 1.75
0 2.02 3.54

1 1.75
0 1.70 2.98
Gentle toilet
1 1.75
0 2.02 3.54

1 1.75
0 1.70 2.98
797.59

116
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION

Armestrrong Ceiling
Ground to Roof Slab
The Same Area with the Area of Granite +Porcline floor tilt &
12092.97 12092.97
Stair Area
Stair 1
15 2.65
5.50 218.63
Stair 2
14 2.72
5.50 209.44
12521.03

7.08 Marble Window cill


At basment floor
1 0.80 0.80 Type W1 Size 2750x1500mm
25 1.40 35.00 Type W2 Size 3150x1500mm
5 5.50 27.50 Type W3 Size 4150x1500mm
63.30 For item no 7.09

117
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION

7.10 threshold
marble
250mm thick
Ground floor
1 1.80 1.80

3 1.60 4.80

3 1.30 3.90

2 0.80 1.60
First Floor
1 1.80 1.80

3 1.60 4.80

3 1.30 3.90

2 0.80 1.60
third floor
1 1.80 1.80

3 1.60 4.80

3 1.30 3.90

2 0.80 1.60
Fourth Floor
1 1.80 1.80

3 1.60 4.80

3 1.30 3.90

2 0.80 1.60
Fifth Floor
1 1.80 1.80

3 1.60 4.80

3 1.30 3.90

2 0.80 1.60
6th floor
1 1.80 1.80

3 1.60 4.80

3 1.30 3.90

2 0.80 1.60
7th floor
1 1.80 1.80

3 1.60 4.80

3 1.30 3.90

2 0.80 1.60
8th floor
1 1.80 1.80

3 1.60 4.80

3 1.30 3.90

2 0.80 1.60
9th floor
1 1.80 1.80

3 1.60 4.80

3 1.30 3.90

2 0.80 1.60
10th floor
1 1.80 1.80

3 1.60 4.80

3 1.30 3.90

2 0.80 1.60
1th floor
1 1.80 1.80

3 1.60 4.80

3 1.30 3.90

2 0.80 1.60
12th floor
1 1.80 1.80

3 1.60 4.80
137.90 Ml

200mm thick
At ground floor
2 0.80 1.60
At first floor
2 0.80 1.60
At second floor
2 0.90 1.80
At third floor
2 0.90 1.80
At Fourth floor
2 0.90 1.80
At Fifth floor
2 0.90 1.80
At six floor
2 0.80 1.60
At seventh floor
2 0.80 1.60
At eight floor
2 0.80 1.60
At ninth floor
2 0.80 1.60
At tenth floor
2 0.80 1.60
At eleventh floor
2 0.80 1.60
At twelvth floor
2 0.80 1.60
21.60 Ml

150mm thick
At ground floor
8 0.70 5.60
2 0.90 1.80
2 1.60 3.20
At first floor
8 0.70 5.60
2 0.90 1.80
2 1.60 3.20
At second floor
8 0.70 5.60
2 1.60 3.20
2 0.90 1.80
At third floor
8 0.70 5.60
2 1.60 3.20
2 0.90 1.80
At Fourth floor
8 0.70 5.60
2 1.60 3.20
2 0.90 1.80
At Fifth floor
8 0.70 5.60
2 1.60 3.20
2 0.90 1.80
At six floor
8 0.70 5.60
2 1.60 3.20
2 0.90 1.80
At seventh floor
8 0.70 5.60
2 1.60 3.20

118
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION
2 0.90 1.80
At eight floor
8 0.70 5.60
2 1.60 3.20
2 0.90 1.80
At ninth floor
8 0.70 5.60
2 1.60 3.20
2 0.90 1.80
At tenth floor
8 0.70 5.60
2 1.60 3.20
2 0.90 1.80
At eleventh floor
8 0.70 5.60
2 1.60 3.20
2 0.90 1.80
At twelvth floor
8 0.70 5.60
2 1.60 3.20
2 0.90 1.80
137.80 Ml

Ceramic Wall Tile


Ground floor
1 4.96 Toilet
2.95 14.63

1 4.96
2.95 14.63

1 5.40
2.95 15.93

1 6.10
2.95 18.00

2 5.16
2.95 30.44

1 5.70
2.95 16.82
Mezanine floor
1 4.96 Toilet
2.95 14.63

1 4.96
2.95 14.63

1 5.40
2.95 15.93

1 6.10
2.95 18.00

2 5.16
2.95 30.44

1 5.70
2.95 16.82
First to 12th floor
12 4.10 Ladies toilet
2.95 145.14

12 4.30
2.95 152.22

12 5.82
2.95 206.03

12 4.92
2.95 174.17

12 10.65
2.95 377.01
Kichenate
12 6.42
2.95 227.27
Gents toilet
12 4.10
2.95 145.14

12 4.30
2.95 152.22

12 5.82
2.95 206.03

12 4.92
2.95 174.17

12 10.65
2.95 377.01
sixth floor
1 5.30
2.95 15.64
Roof slab
4 6.70
2.95 79.06
2651.99

119
Project Mixed use Building
Location ADDIS ABABA
LXWXD DESCRIPTION

10.Painting
a) Internal
1 0.00 The same area with item no

c) RC Ceiling
1 0.00 The same area with item no

b) External
1 2368.77 2368.77 The same area with item no

120
Project Residence
Location ADDIS ABABA
SUB - STRUCTURE
No of
Drg.No Location Ref No Dia Length No of bar member Dia 6 Dia 8 Dia 10 Dia 12 Dia 14 Dia 16 Dia20 Dia24

Footing Pad
0 14 29.41 482 1 14175.62
#REF! 14 ### ### #REF! #VALUE!
#REF! 12 ### ### #REF! #VALUE!
#REF! 12 ### ### #REF! #VALUE!
#REF! 12 ### ### #REF! #VALUE!
#REF! 12 ### ### #REF! #VALUE!
Foundation Column

#REF! 16 3.60 8 #REF! #REF!


8 ### ### #REF! #VALUE!

#REF! 16 3.60 8 #REF! #REF!


8 ### ### #REF! #VALUE!

#REF! 20 3.60 10 #REF! #REF!


8 ### ### #REF! #VALUE!

#REF! 20 3.60 10 #REF! #REF!


8 ### ### #REF! #VALUE!

#REF! 16 3.60 10 #REF! #REF!


8 ### ### #REF! #VALUE!

#REF! 16 3.60 10 #REF! #REF!


8 ### ### #REF! #VALUE!

b) Basment Column

C1 16 3.49 8 11 307.12
8 ### 1 11 #VALUE!

C2 16 3.49 8 12 335.04
8 ### 4 12 #VALUE!

C3 20 3.65 8 10 292
8 ### 6 10 #VALUE!

C4 20 3.65 10 7 255.5
8 ### ### 7 #VALUE!

C5 16 3.49 8 8 223.36
8 1.30 ### 8 #VALUE!

#REF! 16 2.98 4 #REF! #REF!


8 ### 4 #REF! #VALUE!

#REF!

#REF! 14 4.95 4 #REF! #REF!


14 4.95 4 #REF! #REF!
8 ### ### #REF! #VALUE!

#REF! 14 4.95 4 #REF! #REF!


14 4.95 4 #REF! #REF!
8 ### ### #REF! #VALUE!

#REF! 14 4.95 4 #REF! #REF!


14 4.95 4 #REF! #REF!
Project Residence
Location ADDIS ABABA
SUB - STRUCTURE
No of
Drg.No Location Ref No Dia Length No of bar member Dia 6 Dia 8 Dia 10 Dia 12 Dia 14 Dia 16 Dia20 Dia24
8 ### ### #REF! #VALUE!

#REF! 14 4.95 4 #REF! #REF!


14 4.95 4 #REF! #REF!
8 ### ### #REF! #VALUE!

#REF! 14 4.95 4 #REF! #REF!


14 4.95 4 #REF! #REF!
8 ### ### #REF! #VALUE!

#REF! 14 4.95 4 #REF! #REF!


14 4.95 4 #REF! #REF!
8 ### ### #REF! #VALUE!
Grade beam

#REF! 16 7.40 3 #REF! #REF!


16 8.35 3 #REF! #REF!
14 1.85 1 1 1.85
16 3.02 2 1 6.04
16 3.33 4 1 13.32
16 2.15 2 1 4.3
16 5.35 2 1 10.7
14 5.35 2 1 10.7
16 5.44 4 1 21.76
16 5.95 6 1 35.7
8 ### ### #REF! #VALUE!

#REF! 16 8.90 3 #REF! #REF!


16 11.25 3 1 33.75
16 3.93 4 1 15.72
16 3.02 3 1 9.06
20 3.33 5 1 16.65
20 2.73 5 1 13.65
16 6.85 6 1 41.1
16 5.44 4 1 21.76
16 5.84 8 1 46.72
14 3.65 3 1 10.95
8 ### ### 1 #VALUE!
Project Residence
Location ADDIS ABABA
SUB - STRUCTURE
No of
Drg.No Location Ref No Dia Length No of bar member Dia 6 Dia 8 Dia 10 Dia 12 Dia 14 Dia 16 Dia20 Dia24

#REF! 16 1.58 2 #REF! #REF!


14 1.58 2 1 3.16
8 ### ### 1 #VALUE!

#REF! 14 1.58 2 #REF! #REF!


14 1.58 2 #REF! #REF!
7.76 8 ### ### 1 #VALUE!

#REF! 16 7.40 3 #REF! #REF!


16 8.35 3 #REF! #REF!
14 1.85 2 1 3.7
16 3.02 3 1 9.06
14 3.33 4 1 13.32
16 2.15 3 1 6.45
16 5.35 2 1 10.7
14 5.35 2 1 10.7
16 10.70 5 1 53.5
8 ### ### 1 #VALUE!
10 1.30 20 1 26

#REF! 14 6.91 2 #REF! #REF!


14 7.41 2 #REF! #REF!
14 2.70 1 #REF! #REF!
14 2.87 1 #REF! #REF!
16 5.50 2 #REF! #REF!
14 5.50 2 1 11
14 4.20 2 1 8.4
14 5.61 3 1 16.83
8 ### ### 1 #VALUE!

#REF! 14 5.30 2 #REF! #REF!


16 5.30 2 #REF! #REF!
8 ### ### #REF! #VALUE!

#REF! 16 5.80 2 #REF! #REF!


16 5.80 2 1 11.6
8 ### ### 1 #VALUE!

#REF! 14 7.51 2 #REF! #REF!


14 7.41 3 1 22.23
14 2.87 1 #REF! #REF!
14 9.30 2 #REF! #REF!
14 5.61 3 1 16.83
8 ### ### 1 #VALUE!

#REF! 16 7.55 2 #REF! #REF!


14 7.45 3 1 22.35
20 2.70 1 #REF! #REF!
20 2.87 2 #REF! #REF!
14 5.71 2 1 11.42
8 ### ### 1 #VALUE!

#REF! 14 6.91 2 #REF! #REF!


14 7.41 3 1 22.23
14 2.70 1 #REF! #REF!
14 2.87 2 #REF! #REF!
14 8.70 2 1 17.4
14 5.61 2 1 11.22
8 ### ### 1 #VALUE!

#REF! 14 4.45 2 #REF! #REF!


14 4.45 2 1 8.9
8 ### ### 1 #VALUE!

6 #REF! 16 4.95 3 #REF! #REF!


16 4.95 3 1 14.85
8 ### ### 1 #VALUE!
Project Residence
Location ADDIS ABABA
SUB - STRUCTURE
No of
Drg.No Location Ref No Dia Length No of bar member Dia 6 Dia 8 Dia 10 Dia 12 Dia 14 Dia 16 Dia20 Dia24
a) 150mm thick Suspended Flat slab
8 1.05 40504 1 42529.2
Staircase
From Ground to first floor
1 12 7.35 9 1 66.15
m 14 2.31 9 1 20.781
g 14 1.58 10 2 31.6
3.4 n 14 5.97 18 1 107.46
q 14 1.77 9 1 15.93
o 14 2.20 9 1 19.755

RC Wall
8 12.00 14 6 1008
10 3.35 176 2 1179.2
Ground floor
12.024 12 5.17 7 1 36.19
12 9.38 12 1 112.56
12 7.37 13 1 95.81
12 2.87 14 1 40.18
10 7.49 3 1 22.47
12 3.96 11 1 43.505
10 4.10 13 1 53.3
10 7.49 8 1 59.92
12 2.70 13 1 35.1
10 8.13 12 1 97.56
4 12 7.28 12 1 87.36
10 6.70 14 1 93.8
6 1.05 3324 1 3490.2
3490.20 #VALUE! 1532.25 #VALUE! #VALUE! #REF! #REF! 0.00
Weight per M 0.222 0.395 0.617 0.888 1.208 1.578 2.468 3.55
Total weight (kg) 774.82 #VALUE! 945.40 #VALUE! #VALUE! #REF! #REF! 0.00
Add 5% wastage 813.57 #VALUE! 992.67 #VALUE! #VALUE! #REF! #REF! 0.00
Project RESIDENCE
Location ADDIS ABABA
SUPER - STRUCTURE
No of
Drg.No Location Ref No Dia Length No of bar member Dia 6 Dia 8 Dia 10 Dia 12 Dia 14 Dia 16 Dia20 Dia24
Elevation column
ELEVATION COLUMN

C1 16 4.09 14 1 57.26
16 3.58 6 1 21.48
5.3 8 1.10 64 1 70.4

C2 16 4.09 16 1 65.44
16 3.58 8 1 28.64
8 1.10 64 1 70.4

C3 16 4.09 22 #REF! #REF!


16 3.63 6 #REF! #REF!
8 1.20 16 #REF! #REF!
8 1.10 47 #REF! #REF!

C4 16 4.09 18 #REF! #REF!


16 3.63 6 #REF! #REF!
8 1.20 16 #REF! #REF!
8 1.10 47 #REF! #REF!

C5 16 4.09 12 1 49.08
16 3.58 8 1 28.64
8 1.10 48 1 52.8
Floor Beams
First floor
FB-1 16 7.40 3 1 22.2
16 8.35 3 1 25.05
14 1.85 1 1 1.85
16 3.02 2 1 6.04
16 3.33 4 1 13.32
16 2.15 2 1 4.3
16 5.35 2 1 10.7
14 5.35 2 1 10.7
16 5.44 4 1 21.76
16 5.95 6 1 35.7
8 1.50 115 1 172.5
8 1.10 41 1 45.1

FB-2 16 11.40 3 1 34.2


16 3.93 4 1 15.72
16 3.02 4 1 12.08
16 11.40 5 1 57
8 1.50 36 1 54
7.045 10 1.50 17 1 25.5

FB-3 14 3.75 3 1 11.25


14 3.75 3 1 11.25
8 4.60 16 1 73.6

FB-4 16 8.90 3 1 26.7


16 11.25 3 1 33.75
16 3.93 3 1 11.79
16 3.02 3 1 9.06
16 3.33 4 1 13.32
20 2.73 3 1 8.19
16 6.85 5 1 34.25
16 5.44 4 1 21.76
16 5.84 5 1 29.2
14 3.65 3 1 10.95
7.76 8 1.40 86 1 120.4
10 1.40 19 1 26.6

FB-5 16 7.40 3 1 22.2


16 8.35 3 1 25.05
14 1.85 2 1 3.7
16 3.02 3 1 9.06
16 3.33 4 1 13.32
16 2.15 3 1 6.45
16 5.35 3 1 16.05
16 10.70 5 1 53.5
8 1.40 103 1 144.2
10 1.40 19 1 26.6
Project RESIDENCE
Location ADDIS ABABA
SUPER - STRUCTURE
No of
Drg.No Location Ref No Dia Length No of bar member Dia 6 Dia 8 Dia 10 Dia 12 Dia 14 Dia 16 Dia20 Dia24

FB-6 14 6.91 2 1 13.82


14 7.41 2 1 14.82
14 2.70 1 1 2.7
14 2.87 1 1 2.87
16 5.50 2 1 11
14 5.50 2 1 11
14 4.20 2 1 8.4
14 5.61 3 1 16.83
8 1.40 3 1 4.2

FB-7 14 5.80 2 1 11.6


16 5.80 2 1 11.6
8 1.00 #VALUE! 1 #VALUE!

FB-8 14 7.51 2 #REF! #REF!


14 7.41 2 1 14.82
14 2.87 1 1 2.87
14 9.30 2 1 18.6
16 5.61 3 1 16.83
8 ### 70 1 #VALUE!

FB-9 16 7.55 2 1 15.1


16 7.45 2 1 14.9
20 2.70 2 1 5.4
20 2.87 2 1 5.74
14 5.71 2 1 11.42
14 9.21 2 1 18.42
13.8 8 1.00 78 1 78

FB-10 16 6.95 2 #REF! #REF!


16 7.45 2 1 14.9
14 1.83 1 #REF! #REF!
16 2.70 2 #REF! #REF!
20 2.87 3 1 8.61
16 2.00 2 1 4
16 5.15 3 1 15.45
14 4.24 2 1 8.48
16 5.65 2 1 11.3
14 5.65 2 1 11.3
8 ### #VALUE! 1 #VALUE!

FB-11 14 4.45 2 1 8.9


14 4.45 2 1 8.9
8 ### 19 1 #VALUE!

Second floor
SFB-1 16 7.40 3 1 22.2
16 8.35 3 1 25.05
14 1.85 1 1 1.85
16 3.02 2 1 6.04
16 3.33 4 1 13.32
16 2.15 2 1 4.3
16 5.35 2 1 10.7
14 5.35 2 1 10.7
16 5.44 4 1 21.76
16 5.95 6 1 35.7
8 1.50 115 1 172.5
8 1.10 41 1 45.1

SFB-2 16 8.90 3 1 26.7


16 11.25 3 1 33.75
16 3.93 4 1 15.72
16 3.02 3 1 9.06
20 3.33 5 1 16.65
20 2.73 5 1 13.65
16 6.85 6 1 41.1
16 5.44 4 1 21.76
16 5.84 8 1 46.72
14 3.65 3 1 10.95
8 1.50 36 1 54
7.045 10 1.50 17 1 25.5
Project RESIDENCE
Location ADDIS ABABA
SUPER - STRUCTURE
No of
Drg.No Location Ref No Dia Length No of bar member Dia 6 Dia 8 Dia 10 Dia 12 Dia 14 Dia 16 Dia20 Dia24

SFB-3 16 7.40 3 1 22.2


16 8.35 3 1 25.05
14 1.85 2 1 3.7
16 3.02 3 1 9.06
16 3.33 4 1 13.32
16 2.15 3 1 6.45
16 5.35 2 1 10.7
14 5.35 2 1 10.7
16 10.75 5 1 53.75
8 ### 72 1 #VALUE!

SFB-4 14 6.91 2 1 13.82


14 7.41 2 1 14.82
14 2.70 1 1 2.7
14 2.87 1 1 2.87
16 5.50 2 1 11
14 5.50 2 1 11
14 4.20 2 1 8.4
14 5.61 3 1 16.83
8 1.40 91 1 127.4

SFB-5 16 8.90 3 1 26.7


16 11.25 3 1 33.75
16 3.93 3 1 11.79
16 3.02 3 1 9.06
16 3.33 4 1 13.32
20 2.73 3 1 8.19
16 6.85 5 1 34.25
16 5.44 4 1 21.76
16 5.84 5 1 29.2
14 3.65 3 1 10.95
7.76 8 1.40 96 1 134.4

SFB-6 14 7.55 2 1 15.1


14 7.45 2 1 14.9
20 2.70 1 1 2.7
20 2.87 1 1 2.87
14 5.71 2 1 11.42
14 9.21 3 1 27.63
8 1.40 91 1 127.4

SFB-7 14 6.91 2 1 13.82


14 7.41 2 1 14.82
14 2.70 1 1 2.7
14 2.87 1 1 2.87
14 8.70 2 1 17.4
14 5.61 3 1 16.83
8 1.40 #VALUE! 1 #VALUE!

SFB-8 14 4.45 2 1 8.9


14 4.45 2 1 8.9
8 1.00 70 1 70

Roof beams
TFB-1 14 7.11 2 1 14.22
14 8.05 2 1 16.1
14 5.31 2 1 10.62
14 10.71 2 1 21.42
8 1.00 30 1 30

TFB-2 14 8.85 3 1 26.55


14 11.21 2 1 22.42
16 3.93 4 1 15.72
14 6.45 3 1 19.35
14 5.36 2 1 10.72
14 9.68 3 1 29.04
14 8.81 2 1 17.62
9.13 8 1.00 61 1 61
Project RESIDENCE
Location ADDIS ABABA
SUPER - STRUCTURE
No of
Drg.No Location Ref No Dia Length No of bar member Dia 6 Dia 8 Dia 10 Dia 12 Dia 14 Dia 16 Dia20 Dia24

SFB-4 14 6.91 2 1 13.82


14 7.41 2 1 14.82
14 2.70 1 1 2.7
14 2.87 1 1 2.87
16 5.50 2 1 11
14 5.50 2 1 11
14 4.20 2 1 8.4
14 5.61 3 1 16.83
8 1.40 91 1 127.4

SFB-5 16 8.90 3 1 26.7


16 11.25 3 1 33.75
16 3.93 3 1 11.79
16 3.02 3 1 9.06
16 3.33 4 1 13.32
20 2.73 3 1 8.19
16 6.85 5 1 34.25
16 5.44 4 1 21.76
16 5.84 5 1 29.2
14 3.65 3 1 10.95
7.76 8 1.40 96 1 134.4

SFB-6 14 7.55 2 1 15.1


14 7.45 2 1 14.9
20 2.70 1 1 2.7
20 2.87 1 1 2.87
14 5.71 2 1 11.42
14 9.21 3 1 27.63
8 1.40 91 1 127.4

SFB-7 14 6.91 2 1 13.82


14 7.41 2 1 14.82
14 2.70 1 1 2.7
14 2.87 1 1 2.87
14 8.70 2 1 17.4
14 5.61 3 1 16.83
8 1.40 #VALUE! 1 #VALUE!

SFB-8 14 4.45 2 1 8.9


14 4.45 2 1 8.9
8 1.00 70 1 70

TFB-3 14 8.85 2 1 17.7


14 11.21 2 1 22.42
16 3.93 4 1 15.72
14 3.02 2 1 6.04
16 6.45 4 1 25.8
16 5.36 2 1 10.72
14 5.76 3 1 17.28
14 3.61 2 1 7.22
9.13 8 1.40 41 1 57.4
9.13 8 0.90 88 1 79.2

TFB-4 14 7.11 2 1 14.22


14 8.06 2 1 16.12
14 1.85 1 1 1.85
14 3.02 1 1 3.02
14 3.33 2 1 6.66
14 2.15 1 1 2.15
14 10.11 2 1 20.22
14 5.91 3 1 17.73
14.25 8 0.90 96 1 86.4

TFB-5 14 6.91 2 1 13.82

14 7.41 2 1 14.82

14 5.15 3 1 15.45

14 9.25 2 1 18.5
8.545 8 0.90 87 1 78.3
Project RESIDENCE
Location ADDIS ABABA
SUPER - STRUCTURE
No of
Drg.No Location Ref No Dia Length No of bar member Dia 6 Dia 8 Dia 10 Dia 12 Dia 14 Dia 16 Dia20 Dia24

RB-6 14 6.91 1 1 6.91

14 7.41 2 1 14.82

14 2.71 2 1 5.42

14 5.50 4 1 22

14 9.25 2 1 18.5
10.895 8 0.90 73 1 65.7

RB-7 14 6.91 1 1 6.91

14 7.41 2 1 14.82

14 2.71 2 1 5.42

14 2.87 2 1 5.74

14 5.15 2 1 10.3

16 5.15 2 1 10.3

16 4.24 3 1 12.72

14 5.65 2 1 11.3
8 0.90 61 1 54.9

RB-8 14 6.91 1 1 6.91

14 7.41 2 1 14.82

14 2.71 2 1 5.42

14 5.50 4 1 22

14 9.25 2 1 18.5
10.895 8 0.90 73 1 65.7

RB-9 14 4.45 2 1 8.9

14 4.45 2 1 8.9
10.895 8 0.90 24 1 21.6
Water tank beam
Project RESIDENCE
Location ADDIS ABABA
SUPER - STRUCTURE
No of
Drg.No Location Ref No Dia Length No of bar member Dia 6 Dia 8 Dia 10 Dia 12 Dia 14 Dia 16 Dia20 Dia24

SRB-1 14 5.66 2 1 11.32


14 6.31 2 1 12.62
14 1.78 2 1 3.55
14 2.15 2 1 4.3
14 6.46 2 1 12.92
14 5.51 2 1 11.02
10.625 8 0.70 71 1 49.7

SRB-2 14 4.25 2 1 8.5


14 4.25 2 1 8.5
10.625 8 0.70 24 1 16.8

SRB-3 14 4.45 2 1 8.9


16 4.45 2 1 8.9
10.625 8 0.70 24 1 16.8

SRB-4 14 4.45 2 1 8.9


14 4.45 2 1 8.9
10.625 8 0.70 24 1 16.8

Floor Slab
First floor
Along B/n Ax 1&2
12 7.37 7 2 103.18
12 9.38 6 2 112.56
14 1.64 11 2 36.08
8 1.01 11 2 22.264
Along B/n Ax 2&3
12 7.49 9 2 134.82
10 5.80 4 2 46.4
12 2.87 8 2 45.92
10 4.10 8 2 65.6
8 1.01 10 2 20.16
Along B/n Ax 3 & 4
10 4.84 2 2 19.36
12 7.28 12 2 174.72
12 8.09 14 2 226.52
12 2.47 12 2 59.232
Second
Along B/n Ax 1&2
12 7.37 11 2 162.14
12 9.38 12 2 225.12
14 7.37 13 2 191.62
12 1.65 11 2 36.3
8 1.01 11 2 22.264
Along B/n Ax 2&3
12 7.49 3 2 44.94
9.045 10 2.87 24 2 137.76
12 4.10 11 2 90.2
10 4.10 13 2 106.6
10 7.49 8 2 119.84
8 1.01 10 2 20.16
Along B/n Ax 3 & 4
12 2.70 24 2 129.6
12 4.84 41 2 396.88
12 7.28 46 2 669.76
12 6.70 50 2 670
14 1.63 10 3 48.93
8 1.01 10 2 20.16
Near Ax-4
Project RESIDENCE
Location ADDIS ABABA
SUPER - STRUCTURE
No of
Drg.No Location Ref No Dia Length No of bar member Dia 6 Dia 8 Dia 10 Dia 12 Dia 14 Dia 16 Dia20 Dia24
10 2.48 46 2 228.16
6 1.05 #VALUE! 1 #VALUE!
Terrace Floor
Along B/n Ax 2 &3
4.911 10 7.49 50 2 749
Along B/n Ax 3 &4
4.911 8 6.14 22 1 135.08
8 5.05 22 1 111.1
8 7.39 22 1 162.58
10 2.66 28 1 74.48
10 3.57 28 1 99.96
14.36 8 8.14 91 1 740.74
Water Tank
3.287 8 3.77 6 1 22.62
8 6.60 16 1 105.52
10 3.38 22 1 74.36
8 5.11 22 1 112.42

Staircase
From Ground to first floor
1 12 7.35 9 1 66.15
m 14 2.31 9 1 20.781
g 14 1.58 10 2 31.6
3.4 n 14 5.97 18 1 107.46
q 14 1.77 9 1 15.93
o 14 2.20 9 1 19.755

From First to Second floor


r 14 5.33 10 1 53.25
t 14 1.46 10 1 14.6
s 14 2.48 10 1 24.82
3.4 v 14 4.95 10 1 49.46
w 14 2.75 10 1 27.5
u 14 3.36 10 1 33.63
Total length(M) #VALUE! #REF! 1,825.72 3,348.04 #REF! #REF! 85.76 -
Weight per M 0.222 0.395 0.617 0.888 1.208 1.578 2.468 3.550
Total weight (kg) #VALUE! #REF! 1,126.47 2,973.06 #REF! #REF! 211.66 -
Add 5% wastage #VALUE! #REF! 1,182.8 3,121.7 #REF! #REF! 222.2 -
Project:- NOC Head Office Building
Client:- National Oil Ethiopia
Consultant:- Bitalico Trading PLC, Consulting Architects & Engi
Contractor:- China State Construction Enginering Ethiopia PLC
TAKEOFF SHEET
T D R

3 191.91 575.73
3 79.53 238.59
3 0.00
45 72.50 3262.50
4076.82 M2
45 19.80 891.00

891.00 M2

1 1090.00 1090.00

1090.00 M2
51.00 15.00 765.00
20 52.00 1040.00
20 52.00 1040.00
20 35.88 717.60
20 16.00 320.00
34 2.30 78.20

4 9.16 36.64

114.84

186.20
306.20

64 64.04 4098.56
17 61.44 1044.48

5143.04
34 16.13 548.42

4286.43

479.81

14 149.76 2096.64

1 891.7 891.70

1 18876.52 18876.52

14 84.17 -1178.38

17 130.73 -2222.38

15475.76
1 2,324.19 2,324.19

17 305.20 5,188.40

17 130.73 2,222.38

9734.97

-1 15.50
1.00 -15.50 M2
-2 5.51

1.00 -11.02 M2

1139.78 M2

11 0.02
1.22 0.30 m3
11 0.02
1.17 0.26 m3
1 3.93
0.15 0.59 m3
1 3.22
0.15 0.48
1 4.28
0.20 0.86 m3
1 4.35
0.20 0.87 m3
11 0.02
1.22 0.27 m3

11 0.22

1.30 3.13 m3
1 3.99
0.15 0.60 m3
1 3.35
0.15 0.50
1 4.35
0.20 0.87 m3

1 4.62

0.20 0.92 m3

9.66 M3

2 2.07

3.27 13.54 m3
1 2.28

3.27 7.46 m3

1 0.88

3.27 2.86 m3

1 0.35

3.27 1.14 m3

1 0.17

3.27 0.56 m3
1 0.29

3.27 0.95 m3

2 0.16

1.07 0.34 m3
2 0.82

1.07 1.75 m3

2 2.47

3.27 16.14 m3
1 1.76

3.27 5.76 m3
1 1.14

3.27 3.73 m3
2 0.82

3.27 5.36 m3
2 0.17

3.27 1.08 m3
1 0.52

1.07 0.56 m3
-1 8.6 -8.6 m2

1 133.40

0.30 40.02 m2

4 3.32

0.40 2.66 m2
4 2.26
0.40 1.81 m2
4 3.12
0.40 2.50 m2
4 3.12

0.40 2.50 m2

4 1.14

0.40 0.91 m2

4 3.21

0.40 2.56 m2

4 2.25

0.40 1.80 m2

1 1.84 1.84 m2

1 0.40 0.40 m2

1 0.96 0.96 m2

1 2.58 2.58 m2

1156.28 M2

22 1.17

0.15 3.87 m2

1 3.93 3.93 m2
1 3.22 3.22 m2
1 3.64 3.64 m2
1 3.65 3.65 m2

22 1.30
0.15 4.27 m2
1 3.99 3.99 m2
1 3.35 3.35 m2
1 3.64 3.64 m2

1 3.88 3.88 m2

37.45 M2

1 61.66
3.27 201.63 m2

1 47.10

3.27 154.02 m2

1 2.13

3.27 6.98 m2

2 1.65
1.07 3.53 m2

2 4.00

1.07 8.56 m2

1 2.60

1.07 2.78 m2
2 2.40

3.27 15.70 m2

1 1.60

3.27 5.23 m2

2 7.32
3.27 47.84 m2

2 2.40
1.58 8.30 m2

1 7.83

3.27 25.62 m2

480.18 M2
ffice Building
l Ethiopia
o Trading PLC, Consulting Architects & Enginers PLC
tate Construction Enginering Ethiopia PLC
TAKEOFF SHEET
Description T D R
B-Super structure
2. BLOCK WORK
20mm thick HCB 2 4076.82 8153.64
Basement floor(1st-3rd) 2 891.00 1782.00
Ground floor 20 1408.90 28177.92
3 514.54 1543.61
1st-15th Floor 39657.17
TOTAL 22 192.00 4224.00
15mm thick HCB 4224.00
TOTAL 17 53.60 911.20
3. ROOFING 0 1484.26 0.00
3.01, 3.02, 3.03 911.20
TOTAL
4. CARPENTRY AND JOINERY
2 4076.82 8153.64
2 891.00 1782.00
20 1408.90 28177.92
38113.56

22 192.00 4224.00
4224.00

911.20
911.20
49.54
3 704.45 2113.34

1090.00

6256.00

17798.65

891.70

15310.17
15 206.10 3091.50
474.95

143.15
4.02 PARTITION WITH DOORS 3225.75

3843.85

1275.68

PVC TILE AND SKIRTING

PVC TILE AND SKIRTING

GRANITE STAIR ELEMENTS


a
b
c
d
7.14 Marble window sill

7.15. Marble threshold


a

7.14. GRANITE wall tile cladding

7.15 Ceramic for wall

7.16 epoxy

7.17 rough epoxy

7.18. Acoustically sound insulated wall

CEILING
7.19

7.20
7.21. Gypsum board

2 0.48

1.07 1.03
deduct lift hole 1 0.32

1.07 0.34
TOTAL 2 1.00

g)In staircase&landing 3.27 6.54


stair between 4&5 1 1.08
3.27 3.53
2 0.36
1.58 1.14
landing,1,between4&5 73.81

landing,2,between4&5 3 0.92
3.27 8.98
sofit between 4&5 1 1.61
3.27 5.26
1 1.61
3.27 5.26
stair between5&6

2 0.40

3.32
landing,1,between5&6 0.40 0.53
2 0.40
landing,2,between5&6 2.26
0.40 0.36
sofit between5&6
4 0.40
3.12

0.40 1.00

TOTAL
h)In lift shaft shear wall 2 0.40
shear wall between 04&05 1.14

0.40 0.18
2 0.40

3.21
0.40 0.51

2 0.40

2.25

0.40 0.36
22.45

20 2.51

3.27 164.15
coridor,door 2 3.20

3.27 20.93

185.08
shear wall between 05&06
1 1215.58 1215.58

-1 14.13 -14.13

-1 1.61 -1.61

-1 1.61 -1.61

-3 0.92 -2.75

-20 0.79 -15.70

-2 0.64 -1.28

-1 23.41 -23.41

-1 40.10 -40.10
enterances -1 6.12 -6.12

-1 1.32 -1.32

-1 3.2 -3.2
External 3 6.70

3.27 65.73
for,submerged 2 10.73
at,axis,9,x 3.27 70.17

135.90
y

at,axis,7,x

at,axis,3,x

BOTH 7THand 8TH


at,axis,2,x
###
at,axis,1,x
###

y,direction ###
ALL ducts form work
###

###
TOTAL
f)To staircase & landing ###
for stairbetween04&05
###
landing
soffit

for stair,between05&06

landing

soffit

TOTAL
g)To lift shaft shear wall

enterance

enterance

enterance

enterance

enterance

panoramic shear wall

enterance
TOTAL
72.5
217.5

Description
6.PLASTERING AND POINTING

6.01.Two coats of plastering


a) To all internal wall surface

Shear wall

M2

M2 b) To exposed Column and beam

c) Stair soffit
M2

6.02. Gypsum plaster

a) To all internal wall surface

Shear wall
M2

M2 b) To exposed Column and beam

M2 c) Stair soffit

6.03.Three coats of plastering


M2 a) To all External wall surface

b) To all Internal wall surface

c) To exposed Column and beam

M2 d) To RC slab and Stir soffit

7. FINISHING

7.2 Cement screed


a
b
7.03 Ceramic tile
7.04 Ceramic Skerting

7.05 PORCELAINED tile


7.06 PORCELAINED sekerting
Ground 7.07 Granite tile
M
1st-15

7.08 Granite sekerting


m3
m3

paronamic shear wall


M3

m3

m3
m3 TOTAL
i)In shear walls
shearwallataxis040506
m3
shearwallataxisAalong06
m3
shearwallataxisAalong04
m3
submerged,beams
Axis,C&D,at,9
x,direction

m3
y,direction

m3
Axis,7&3,at,B&E
x,direction

m3

Axis,2,at,B&E
x,direction

m3
Axis,1at,C&D
x,direction

m3
y,direction

m3

M3 TOTAL
B-super structure(8TH,FORM,WORK)
a)To Elevation columns
round
m2
Rectagl(80*80)
m2
M2 TOTAL
d)to floor slab
m2 m2Flat slab
m2 deduct,vip,lift
m2 shear,wall,@4
m2 shear,wall,@6
m2m deduct,shear,wall,4,5,6
m2 deduct,column,round
m2 rectangular
m2 stair&shearwalls
m2
m2 ALL,ducts,deduct
m2

m2
h)In shear wall
shearwall040506
m2
shearwallataxisAalong0406
m2
M2 TOTAL

7THand 8TH REIFORCEMENT TAKEOFF


2.04 Reinforcement bar
Kg b) Dia. 8mm deformed bar

Kg c) Dia. 10mm deformed bar

Kg d) Dia. 12mm deformed bar

Kg e)Dia. 14mm deformed bar

Kg f) Dia. 16mm deformed bar

Kg g) Dia. 20mm deformed bar

Kg h) Dia. 24mm deformed bar


Floor Area Circumfrance No. Column Framless Glass Hand rail
B3 1428.81 155.92 22 Length 3.9
B2 1428.81 155.92 22 3.79
B1 1428.81 155.92 22 6.12
G 1484.26 159.75 22 5.86
Maizanin 1238.91 142.96 22 5.88
1 1314.78 150.7 22 5.91
2 1170.01 131.72 22 6.12
3 1198.18 133.23 22 3.8
4 1214.67 134.06 22 11.82
5 1222.64 134.47 22 12.2
6 1281.64 134.49 22 4.78
7 1214.96 134.49 22 5.88
8 1159.95 130.13 22 13 72.16 3 2814.24
9 1123.77 130.28 22 2 31.44 3 188.64
10 1011.63 127.96 22 1 30.1 6 180.6
11 1014.24 125.15 22 3183.48
12 1036.1 121.75 22
13 965.37 117.81 22
14 906.24 113.39 14
15 783.28 113.64 4
Roof 427.59 88.21
19,768.22 2324.19
891.7
18,876.52

4286.43
1442.89
2843.54
Hand rail
13 50.7
No of
1st-3rd Basment floor Premetre Hight Area Floor Area
Shear wall around
stair
outer 3 38.68 3 116.04 84.2
inner core 3 38.4 3 115.2 32.27
Colider 3 15.8 3 47.4 8.4
Lift shaft shear wall 3 8.45 3 25.35 14.25
Shear wall 3 37.02 3 111.06
3
Ramp 3
opining 3 144
Ramp 3 145.398 479.8134
3 704.448
Block work 3 75.93 3 227.79
3
Column corner Rubber 3 41.6 1.2 49.92
Shear wall 3 37.02 1.2 44.424

Ground Floor

60.8 281.9
49.4
45.6
30.4
12.8
1.5
200.5