Uponor have developed a range The Uponor Manifolds Uponor Control Pack (V4)
of manifolds to suit various To complement Uponor’s To coincide with the launch of
applications in domestic and existing range of high the manifolds Uponor are also
commercial buildings. Three quality hot and cold (H&C) adding an improved Compact
new manifolds are now available water manifolds Uponor are Control Pack to the range
primarily designed for radiators introducing three heating of UFH water temperature
and underfloor heating. manifolds. The new range of controls.
Uponor manifolds include:
Manifold Plumbing The Uponor Control Pack (V4)
Manifold plumbing is becoming • The Uponor TM Manifold is responsible for blending
increasingly popular in the with Topmeters (manifold and circulating water around
UK as installers and designers also available with the the underfloor heating circuits
are becoming aware of the underfloor heating Compact and will serve an area of up to
range of benefits; for both Control Pack V4 already 160m² with a 14kW maximum
hot and cold water services, assembled). heat load. For detailed
and as a distribution point information on the Compact
• The Uponor LS Manifold with
to serve a heating system. lockshield valves. Control Pack see page 5 for
Further advantages to heating details.
installations can be found on • The Uponor NV Manifold
without loop isolation.
manifolds where loops can be
isolated via electrically operated
actuators thus allowing
sophisticated controls to be
integrated into the system.
Benefits
Benefits of manifold plumbing
used in conjunction with
electrically operated controls
include:
2
Uponor Heating Manifolds - Plumbing Systems
3
Uponor Heating Manifolds - UFH Systems
4
Uponor Water Temperature Control
5
Often our customers choose UFH for the ground and first floors of their properties
but this is not always the case. Many customers feel that UFH is the right choice for the
ground floor and a radiator system is the most suitable for the first floor of their property.
Introduction
At Uponor we have found that system has been installed on The time control is carried out
in response to the Governments the ground floor and radiators via the single Interface I-75,
push towards reducing carbon installed on the first floor with which controls both the radiator
dioxide emissions; installers, both of the systems controlled and the UFH system.
designers and developers are by the Uponor Control System
recognising that the overall – Radio (a wired system is also The Interface I-75 can control
efficiency and effectiveness of available). up to 3 controllers which can
any heating system is directly manage the operation of
related to the system controls. The UFH is fed by an Uponor UFH and radiator manifolds
By investing in their controls, TM Manifold with a Compact or alternatively it can control
customers will in return receive Control Pack fitted to blend and just radiator manifolds or
a more efficient system with circulate the water. just UFH manifolds. Time
increased controllability and The radiators are shown and temperature profiles can
also create a more comfortable supplied via an Uponor LS be viewed and set from this
environment for the occupants. Manifold which is designed to centralised point along with the
handle the higher temperature holiday mode function, pump/
The next two pages look at water. valve exercise function,
how through the use of modern minimum and maximum room
technology a radiator and UFH Uponor Control System temperatures and also gives the
system can be combined and - Radio user the ability to view each
controlled. The temperature in each room rooms actual and set point
of the property is controlled via temperature. For further details
Example Installation a radio frequency thermostat. A of the Uponor Control System
The illustration below shows a choice of three thermostats are – Radio and Wired version,
typical domestic property where available which can be mixed to please contact our marketing
an underfloor heating (UFH) suit the client requirements. department for a brochure or
visit our website.
Controller C-55
ATC Cylinder
Thermostat
Radiator
Zone Valve
Primary Connections
The illustration above shows Each circuit is isolated via a The UFH will work in a similar
a two dimensional plumbing zone valve. If one of the radiator way to the radiator system.
schematic of a manifold fed thermostats calls for heat the The hot water cylinder will be
radiator and UFH system. Both thermostat’s corresponding supplied by the boiler if the
systems are supplied by the thermal actuator will open. The cylinder thermostat calls for
same system boiler and a hot Controller C-55 will then send heat. This will open the cylinder
water cylinder is also shown. a demand signal to the radiator zone valve which, once open,
circuit zone valve which once will again send a signal to fire
fully open will send a demand to the boiler. This circuit would not
fire the boiler. be required if a combi-boiler
was installed.
Uponor TM Manifold
The Uponor TM Manifold includes Topmeters on the flow manifold for balancing
and viewing circuit flow rates. Includes chrome plated flow and return headers
pre-mounted on nickel plated manifold brackets with fill & drain points. Primary
connections are 1” BSP and outlet connections are ¾” Eurocone. Designed for
use with underfloor heating systems.
Note: Thermal actuators & Eurocone compression adaptors are supplied
separately.