Uponor Heating Manifold Systems


Uponor Housing Solutions are pleased to announce the arrival of our
latest range of Underfloor Heating (UFH) and Radiator Manifolds. To
complete the launch, a new Control Pack has been designed and for
the first time the Pack is available to purchase pre-assembled to the
UFH manifold.
Uponor Heating Manifolds
With functionality, quality and installation ease in mind Uponor set out to design
and deliver a range of manifolds suitable for both UFH and radiator plumbing.

Uponor have developed a range The Uponor Manifolds Uponor Control Pack (V4)
of manifolds to suit various To complement Uponor’s To coincide with the launch of
applications in domestic and existing range of high the manifolds Uponor are also
commercial buildings. Three quality hot and cold (H&C) adding an improved Compact
new manifolds are now available water manifolds Uponor are Control Pack to the range
primarily designed for radiators introducing three heating of UFH water temperature
and underfloor heating. manifolds. The new range of controls.
Uponor manifolds include:
Manifold Plumbing The Uponor Control Pack (V4)
Manifold plumbing is becoming • The Uponor TM Manifold is responsible for blending
increasingly popular in the with Topmeters (manifold and circulating water around
UK as installers and designers also available with the the underfloor heating circuits
are becoming aware of the underfloor heating Compact and will serve an area of up to
range of benefits; for both Control Pack V4 already 160m² with a 14kW maximum
hot and cold water services, assembled). heat load. For detailed
and as a distribution point information on the Compact
• The Uponor LS Manifold with
to serve a heating system. lockshield valves. Control Pack see page 5 for
Further advantages to heating details.
installations can be found on • The Uponor NV Manifold
without loop isolation.
manifolds where loops can be
isolated via electrically operated
actuators thus allowing
sophisticated controls to be
integrated into the system.

Benefits
Benefits of manifold plumbing
used in conjunction with
electrically operated controls
include:

• Higher efficiency due to The 3 Uponor manifolds are all


advanced controls made of high quality, chromed
• Increased thermal comfort for solid brass with a unique
occupants “Thistle bar” profile, supported
• Independent control over by nickel plated manifold
each circuit brackets. The manifolds are
• Less fittings required and a true 1” bore with 1” BSP
none under the floor FT connections onto the
manifold and ¾” Eurocone
• One central point for
isolating each circuit outlets to the UFH circuits or
the radiators. Each manifold
comes complete with fill and
drain points for simple filling
and venting of the system and
single port extension kits are
available along with a range of
accessories.

2
Uponor Heating Manifolds - Plumbing Systems

• For use in radiator • True 1” bore with ¾”


applications to serve Eurocone threaded outlets.
radiators or towel rails • Comes complete with Fill/
(95°C, 10 bar). Drain valves.
• Available in configurations • Pre-mounted on nickel
from 2 port to 8 port. plated brackets for secure
Single port extension kits mounting and enhanced
are also available. aesthetics.
• Pipework connections • Made from high quality,
on to the manifold are chromed solid brass with
1” BSP Female. unique “Thistle” profile.

Uponor LS Manifold Uponor NV Manifold


The Uponor LS Heating The Uponor NV Heating
Manifold is designed to be used Manifold is designed to be used
in radiator heating systems that in radiator heating systems that
would typically use a number of would typically use traditional
hard wired or radio thermostats thermostatic radiator valves
to control the temperature fitted to each radiator or towel
in each room with a radiator rail.
fitted. The manifold also allows
the system to be balanced at
the manifold by adjusting the
lockshield valves fitted to each
manifold port.

• Supplied with 2 manual


air vents

• The lockshield valves can


be adjusted by using a
5mm Allen key for accurate
balancing at the manifold.
• Caps are fitted on the return
manifold that if removed
allows thermal actuators to
be fitted enabling control by
room thermostats.

• Fittings are available to go onto 12,16 & 20mm MLC Pipe


(Multi Layer Composite Pipe).
• Fittings are available to go onto 12,15 & 20mm PEX Pipe

(Cross Linked Polyethylene Pipe)

3
Uponor Heating Manifolds - UFH Systems

Uponor TM Manifold Control the Room


The Uponor TM Heating Manifold Temperature
is specifically designed for UFH. The manually adjustable caps can
The unit is to be installed in a be removed to allow electrically
central location and act as a operated thermal actuators
distribution and regulating point to be fitted. These actuators
for the UFH system. open to allow a flow of water
around when the actuators
Water based UFH systems work corresponding room thermostat
by running warm water through calls for heat.
coils of embedded pipe work
which heats the floor. This If the manifold is supplying
effectively turns the floor into • Heating manifold for use in just one room it would not be
a very large radiator. Since the underfloor applications with
necessary to use actuators on
floor gives a large heated area, a unique ‘Thistle’ profiling.
the manifold. Instead a two port
low floor temperature is required • Made from high quality, motorized zone valve would
to maintain a comfortable chromed solid brass. be fitted on the flow to the
environment. • Available in configurations manifold.
from 2-port to 12-port (with
On a mixed heating system single port extension also
where radiators are used on available).
the first floor and UFH is used • Pre-mounted on nickel plated
on the ground floor then the brackets for secure mounting
floor heating system will require and enhanced aesthetics.
a lower water temperature
• High quality top meters
but generally a higher flow. with 0-6 L/M indication for
The Compact Control Pack V4 accurate flow measurement
would manage the blending and and regulation.
pumping of the UFH heating
flow water. Alternatively either • True 1” manifold bore for
good flow characteristics
the UNIset Mini could be used or
the UP36 Weather Compensator • Colour coded tamper proof
could be used in conjunction flowmeters and valve caps.
with a UNIset Midi or Maxi. • Comes complete with 2
The regulation of the individual fill/drain valves.
circuits is set at the manifold to • Pipework connections (flow/
ensure that there is a sufficient return) at the manifold are 1”
flow around each circuit to heat BSP female.
the room. • Maximum temperature 70°C.
• ¾” Eurocone outlets suitable
Each coil is run from a for 14 & 16mm MLCP and 12,
centrally positioned manifold 15 & 20mm PEX pipes.
where the filling, venting and
commissioning takes place. • Fill and drain points
included as standard. Fill
and drain point with manual
or automatic airvents also
available.

4
Uponor Water Temperature Control

Compact Control Pack V4


The Compact Control Pack is a
solid and robust unit dedicated to
serving and regulating the UFH
system. The unit is available as a
stand alone unit or alternatively it
can be bought pre-assembled to
the Uponor TM Manifold saving
valuable installation time.

The Compact Control Pack is


designed to mix the primary
boiler flow water with the under
floor heating return water.
This is managed via a two
port injection valve which is
situated on the boiler flow which
when open, allows the higher
temperature boiler flow water
to blend with the UFH return
water in the return manifold. This
maintains the required UFH flow
temperature. An internal pipe
sensor is fitted within the 90°
elbow which operates the two
port thermostatic injection valve.
A secondary pump then circulates
the water around the UFH loops. • Now available as a stand alone • The flow temperature sensor
To ensure that the majority of unit or supplied pre-assembled is mounted internally for an
the water is forced around the to the manifold. accurate reading.
UFH pipe network, a lockshield • As standard it will be left • Fill and drain points are
is positioned on the return back hand justified but can easily included along with a high
to the boiler which is used for be changed to be right hand quality isolation valve situated
balancing the system. justified. below the pump for easy
• A preset robust high limit filling.
The Compact Control Pack also thermostat is included to • The unit includes a three
includes a fail-safe device. A protect floors. speed, Grundfos 15-60 pump.
high limit thermostat is fitted
to ensure that water exceeding
• ¾” injection and lockshield • It is possible to isolate via
valves reduce the response the injection and lockshield
60°C will not flow around the
time. valve so there’s no need for
UFH system (as per BS EN:1264)
• Large floor coverage due to additional ball valves.
since high temperature water may
damage floor coverings. increased size of injection • The unit is compact so can be
valve (max 160m² and 14kW). installed in a large variety of
As the name suggests the unit • ¾” BSP FT on the primary locations.
is deceptively small and ideal for flow and return valves allow • Joints are created using
fitting in a range of situations. a range of pipe sizes to be O-rings. No PTFE or jointing
As with its predecessors the unit connected. compounds are required.
is primarily designed for running • The Version 4 pack is a solid • A thermostatic head is
boiler flow and return pipework unit with no plastic parts included with a temperature
to the left hand side of the unit that can be easily broken or range from 20-60°C which
and all the pre-assembled packs damaged. allows simple control over the
are supplied this way. This can • Aesthetically the Compact water temperature.
simply and quickly be changed if Control Pack is a polished,
the primary pipework is feeding quality unit.
the right hand side of the unit.

5
Often our customers choose UFH for the ground and first floors of their properties
but this is not always the case. Many customers feel that UFH is the right choice for the
ground floor and a radiator system is the most suitable for the first floor of their property.

Introduction
At Uponor we have found that system has been installed on The time control is carried out
in response to the Governments the ground floor and radiators via the single Interface I-75,
push towards reducing carbon installed on the first floor with which controls both the radiator
dioxide emissions; installers, both of the systems controlled and the UFH system.
designers and developers are by the Uponor Control System
recognising that the overall – Radio (a wired system is also The Interface I-75 can control
efficiency and effectiveness of available). up to 3 controllers which can
any heating system is directly manage the operation of
related to the system controls. The UFH is fed by an Uponor UFH and radiator manifolds
By investing in their controls, TM Manifold with a Compact or alternatively it can control
customers will in return receive Control Pack fitted to blend and just radiator manifolds or
a more efficient system with circulate the water. just UFH manifolds. Time
increased controllability and The radiators are shown and temperature profiles can
also create a more comfortable supplied via an Uponor LS be viewed and set from this
environment for the occupants. Manifold which is designed to centralised point along with the
handle the higher temperature holiday mode function, pump/
The next two pages look at water. valve exercise function,
how through the use of modern minimum and maximum room
technology a radiator and UFH Uponor Control System temperatures and also gives the
system can be combined and - Radio user the ability to view each
controlled. The temperature in each room rooms actual and set point
of the property is controlled via temperature. For further details
Example Installation a radio frequency thermostat. A of the Uponor Control System
The illustration below shows a choice of three thermostats are – Radio and Wired version,
typical domestic property where available which can be mixed to please contact our marketing
an underfloor heating (UFH) suit the client requirements. department for a brochure or
visit our website.

Radio Thermostat T-55 Interface I-75

Controller C-55

Heating Manifold with Heating Pack


Lockshield Valves (Heating Manifold with Topmeters
& Compact Control Pack)

6 Radio Thermostat T-75


2D Plumbing Schematic
Controller (C-55)

Radio Thermostat (T-55)

Heating Manifold with


Optional Hot Water Cylinder Lockshield Valves
Public Radio Thermostat (T-53)
Cylinder
Zone Valve Thermal
Actuators

ATC Cylinder
Thermostat

Radiator
Zone Valve

Interface (I-75) Controller (C-55) Radio Thermostats (T-75)

Heating Manifold with


Topmeter Valves
UFH
Lockshield Valve
Zone Valve
Immersion High Limit Thermostat
Thermal
Actuators Underfloor Heating Pump
Boiler Auto Injection Valve
& System Pump Bypass

Primary Connections
The illustration above shows Each circuit is isolated via a The UFH will work in a similar
a two dimensional plumbing zone valve. If one of the radiator way to the radiator system.
schematic of a manifold fed thermostats calls for heat the The hot water cylinder will be
radiator and UFH system. Both thermostat’s corresponding supplied by the boiler if the
systems are supplied by the thermal actuator will open. The cylinder thermostat calls for
same system boiler and a hot Controller C-55 will then send heat. This will open the cylinder
water cylinder is also shown. a demand signal to the radiator zone valve which, once open,
circuit zone valve which once will again send a signal to fire
fully open will send a demand to the boiler. This circuit would not
fire the boiler. be required if a combi-boiler
was installed.

Uponor Radio Thermostat T-75 7


Underfloor & Radiator Heating

Manifolds, Adapters & Accessories Manifolds, Adapters & Accessories


Description Code Pack Description Code Pack
Qty Qty

Uponor LS Manifold Compact Control Pack V4
The Uponor LS Manifold includes lock shield valves on the flow manifold for Designed for the control of the water temperature and the flow rates in
balancing the system. The manifold includes chrome plated flow and return underfloor heating systems, floor areas up to 160m² and a maximum 14kW heat
headers pre-mounted on nickel plated brackets with fill & drain points. Primary load. The pack is designed to bolt onto the Uponor TM Manifold. Incorporates a
connections are 1” BSP and outlet connections are ¾” Eurocone. Designed for high limit protection function preset to 60°C, a two port thermostatic injection
use in Radiator systems. valve, an UFH pump and a balancing valve. The picture below shows the unit
Note: Thermal actuators & Eurocone compression adaptors are supplied connected to the Uponor TM Manifold (not included).
separately.
230v UFHCV4 1
1 loop extension set HTGLS1 1
2 loops HTGLS2 1
3 loops HTGLS3 1
4 loops HTGLS4 1
5 loops HTGLS5 1
6 loops HTGLS6 1 Uponor Heating Control Pack
7 loops HTGLS7 1 The pack is made up of the Uponor TM Manifold with a Compact Control Pack
V4 prefixed to the manifold. The unit is ready to be wall mounted straight from
8 loops HTGLS8 1
the box. For supplying UFH systems with floor areas up to 160m² and a maximum
Uponor NV Manifold 14kW heat load.
The Uponor NV Manifold includes chrome plated flow and return headers
HTG Control Pack 2-Port UFHPK2 1
pre-mounted on nickel plated brackets with fill & drain points. Primary
connections are 1” BSP and outlet on nickel plated connections are ¾” Eurocone. HTG Control Pack 3-Port UFHPK3 1
Designed for use in Radiator systems. HTG Control Pack 4-Port UFHPK4 1
Note: Eurocone compression adaptors are supplied separately. HTG Control Pack 5-Port UFHPK5 1

1 loop extension set HTGNV1 1 HTG Control Pack 6-Port UFHPK6 1

2 loops HTGNV2 1 HTG Control Pack 7-Port UFHPK7 1

3 loops HTGNV3 1 HTG Control Pack 8-Port UFHPK8 1

4 loops HTGNV4 1 Uponor 1” Ball Valve


5 loops HTGNV5 1 For use with Uponor Heating Manifolds (sold separately).
6 loops HTGNV6 1
1” 590015 1
7 loops HTGNV7 1
8 loops HTGNV8 1

Uponor TM Manifold
The Uponor TM Manifold includes Topmeters on the flow manifold for balancing
and viewing circuit flow rates. Includes chrome plated flow and return headers
pre-mounted on nickel plated manifold brackets with fill & drain points. Primary
connections are 1” BSP and outlet connections are ¾” Eurocone. Designed for
use with underfloor heating systems.
Note: Thermal actuators & Eurocone compression adaptors are supplied
separately.

1 loop extension set HTGTM1 1


2 loops HTGTM2 1
3 loops HTGTM3 1
4 loops HTGTM4 1
5 loops HTGTM5 1
6 loops HTGTM6 1
7 loops HTGTM7 1
8 loops HTGTM8 1

Uponor Housing Solutions Limited


Snapethorpe House
Rugby Road Uponor (Ireland) Limited
Lutterworth Specification Centre, North Unit 13, Seatown Business Campus
Leicestershire Pavillion 3 Specification Centre, South Seatown Road, Swords
LE17 4HN Buchanan Business Park Space House Co. Dublin, Ireland
T 01455 550355 Stepps Satellite Business Village T 00 353 (0) 1895 7430
UHTGMSYS-Mar 2008

F 01455 550366 Glasgow Crawley F 00 353 (0) 1895 7434


E hsenquiries@uponor.co.uk G33 6HZ RH10 9NE E sales@uponorhousingsolutions.ie
W www.uponorhousingsolutions.co.uk T 0141 7795222 T 01293 655488 W www.uponorhousingsolutions.co.uk

Potrebbero piacerti anche