SIPS 2 Controller Rack

Description The green LED is lit when the and commands are sent to all outlets
The Type 7881 Controller is a 4U compass controller is connected to in parallel.
high, 19" rack-mounting frame, with the streamers through the rack; the
six slots to accommodate up to six SIPS communication circuits are
SIPS 2 Controller boards. All boards isolated. The red LED indicates the The M/S sync (Master/Slave sync) is
are plug-in for easy field replacement Compass controller has been a BNC socket. It is used to cross-link
and any mix of XSRS and HGPS disconnected and SIPS has the lines. to another chassis so that
Controller boards can be used. synchronisation can be achieved
between transceivers controlled
Rear panel controls and through different controller chassis.
The plug-in power supply module connections SHOTPOINT is also a BNC socket.
runs off any 110-240VAC, 50-60Hz The System Controller Rack rear Shot-points are commonly used to
supply. The module supplies the panel is illustrated overleaf. This has synchronise the operation of SIPS
backplane with +15, -15 and a POWER connection for the mains with the rest of the instrumentation on
+5Volts. lead and the PSU auto-senses board. A shot-point is also referred to
applied mains voltage. as a closure.

The rear panel carries the power The RS232 or RS485 serial ports on
connector, BNCs for M/S Sync and The XSRS streamer inductive the Controllers can be connected to
Shot-point as well as a 9-pin ‘D’ communication wire-pairs are an appropriate serial connector on
female for RTS host comms (not used) plugged into the XSRS Controller IN the host computer.
and a 15-pin ‘D’ female for TEST connectors. If the SIPS system were to
(factory use). control sharing of the lines a
compass/Bird controller would be
connected to the OUT connectors.
A rocker switch on the front panel
may be set to SIPS or BIRDS. A pair Key Features
of LED’s indicates the mode of The HGPS transceivers are
operation as follows: connected to the HGPS Controller • 19’ Rack Mountable
outlets. Since transceiver replies are • Only 4U high
tagged with the transceiver address, • 110-240V AC
it does not matter which transceiver
• RS232 & RS485 ports available
is connected to which outlet. Power