Sei sulla pagina 1di 3

Location: Brgy.

San Antonio, Makati City


Wind Velocity: 290 kph
Occupancy Category: Essential Facilities
Directionality Factor, Kd: 0.85
Topographic Factor, Kz: 1.08
Height: Roof: 15.4m
Level 5: 13.4m
Level 4: 10.75m
Level 3: 8.1m
Level 2: 5.45m
Level 1: 2.8m
Enclosed Building, Flat Terrain
Exposure: C
Gust Factor, G: 0.85
Internal Pressure Coefficient: ±0.18
Wall Pressure Coefficients, Cp: Windward Wall: 0.8
Leeward Wall: -0.5
Side Wall: -0.7

Level Height (m) Kz qz (kN)


1 2.8 0.80 27.05
2 5.45 0.88 29.75
3 8.1 0.95 32.12
4 10.75 1.01 34.15
5 13.4 1.06 35.84
Roof 15.4 1.09 36.86

Velocity Pressure Coefficients


Height Above Ground Level (m) Exposure C
0-4.6 0.85
6.1 0.90
7.6 0.94
9.1 0.98
12.2 1.04
15.2 1.09
18 1.13
SAMPLE CALCULATIONS:

For Level 1

Windward Wall

P = qzGCP-qz(GCPi)

qz = 0.613(kz)(kzt)(kd)(V^2)

qz = 0.613(kz)(1.0)(0.85)(80.556^2)

qz = 36.86kz

By Linear Interpolation:

4.6-2.8 = 6.1-4.6
0.85-kz 0.90-0.85

kz = 0.80

P1 = 36.86(0.80)(0.85)(0.8)±(36.86)(0.18)

P1 = 26.6866 kPa or 13.4170 kPa

Leeward Wall

P = qzGCP

L/B = 30/30 = 1

Therefore, Cp= -0.5

P1 = 36.86(0.80)(0.85)(-0.5)

P1 = 12.5325 kPa

Side Wall

P =qzGCP

P1 = 36.86(0.80)(0.85)(-0.7)

P1 = 17.5454 kPa
Level Windward Leeward Side Wall
1 26.6866 -12.5325 -17.5454
2 28.6918 -13.7856 -19.2999
3 30.4464 -14.8822 -20.8351
4 31.9502 -15.8222 -22.1510
5 33.2035 -16.6054 -23.2476
Roof 33.9554 -17.0754 -23.9056