Sei sulla pagina 1di 3

FAILURE MODE AND EFFECTS ANAL

Item: Centrifugal Pump Responsibility:


Model: Prepared by:
Core Team: Chris Satria Pramana

Occurance
Severity
Potential Potential Cause(s)/
Process Potential
Effect(s) of Mechanism(s) of
Function Failure Mode
Failure Failure

No Liquid
8 Lack or loss of prime 2
Delivery

Defective or plugged
Insufficient Low Flowrate 6 4
impeller
Flow

Low
Discharge 6 Cavitation 4
Pressure
Transfering
fluids from
one place to
another Excessive Disturbing
4 Improper bearing 5
Vibration sound/noise

High
Overheating operating 3 Shaft Misalignment 5
temperature

Requiring too High electrical High head loss on


2 3
much Power bill discharge system
FAILURE MODE AND EFFECTS ANALYSIS

Chris Satria Pramana FMEA number: 123456


Chris Satria Pramana Page : 1 of 1
FMEA Date (Orig)3/12/2018 Rev:

Action Results
Detection
Current R
Recommended
Process P Responsibility
Action(s) Actions Taken S O
Controls N

None - manually Fill pump with water


Maintenance Filling pump with
check if there's any 2 32 or replace with self- 3 1
engineer water
fluid flows priming pump

Replace or clean Design team / Cleaning impeller


None 8 192 impeller and install Maintenance and installing flow 3 1
flow meter engineer meter

Reduce length of
Reducing suction
suction pipe or add
pipe length and
None 8 192 pump booster and Design team 3 1
installing pressure
install pressure
gauge
gauge

None - manually
Replace with proper
detect if there is 5 100 Design team Replace bearing 2 2
bearing
excessive noise

None - measure
manually and check
Maintenance
specification of 5 75 Shaft alignment Shaft alignment 2 2
engineer
operating
temperature

None - check the


Evaluate piping, Redesign piping,
average of electrical 5 30 Design team 1 1
valves and fitting valves and fitting
bill
1

Results
R
D P
N

2 6

1 3

1 3

5 20

5 20

5 5

Potrebbero piacerti anche