Sei sulla pagina 1di 3

Carrier(U900/U2100)

Date of Action
Site NAME
KPI NAME

Cell Name

Site Id
Phase
RNC

CS_call_blocking WNE1861 WNE186 HQRNC02 PHASE-2 KOM0001A 1/29/2020 U2100

CS_call_blocking WNE1864 WNE186 HQRNC02 PHASE-2 KOM0001A 1/29/2020 U2100

PS_call_blocking WNE2373 WNE237 MRRNC01 PHASE-1 DIF0005A ### U2100

PS_call_blocking WNE1922 WNE192 KORNC01 PHASE-2 TCH0001A 2/10/2020 U2100


Action Type ( Modernization/Swap Siemens to Nokia/Swap Ericsson

02-02-2020

03-02-2020

04-02-2020

05-02-2020

06-02-2020

07-02-2020

08-02-2020

09-02-2020

10-02-2020

12-02-2020
11-02-2020
3G only U2100 modernized, U900 is still pending 78.09 85.11 45.2 33.03 5.29 32.11 39.67 38.46 45.78 31.86 10.78

3G only U2100 modernized, U900 is still pending 62.66 71.37 36.06 49.86 17.49 35.9 40.58 44.33 61.85 46.9 56.63

3G site completely modernized 0 0 0 0 0 0 0 0 0 0 0.37

ite completely modernized(U2100 Sector-2 Disable and U900 sector-3


0 RU
0 Faulty)
0.39 0 0 0 0 0 0.905 0.84
Remark

Wrong HW installation as per BoQ/blk due to


pwr and code

Wrong HW installation as per BoQ/blk due to


pwr and code

Spike observed at 700HRs but later it came


back to normal.Site is also having SCTP packet
loss

Blocking observed due to DeniedAdmDlPwr.


Cell fluctuation also observed on the cell.
Pwradm need to change from 85 to 95.Site is
also having SCTP packet loss