This is for use with 4Byte Mifare cards in Standalone mode or with an iNet ACU Connection.
1. In MorphoManager go to Administration > Wiegand Profile and either use the attached wiegand format
from this bottom of this guide (then skip to step 7) or Add a new Wiegand profile.
2. To Add the profile type the Name for the Format e.g. “Controlsoft Mifare 34 Bit”, select the Bit Length to 34
and click Next.
3. Click Add and Select Parity. Name this Even Parity, select “Mode” to be “Even”. Basis Bits should be “1, 2, 3,
4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16”. Click Next.
4. Click Add, select User. Name this “Card Number”. Tick Allow Random and Length should be “32”. Click Next
when complete.
5. Click Add, Select Parity, Name this Odd Parity, select “Mode” as Odd, and Basis Bits as “17, 18, 19, 20, 21,
22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32”. Click Next.
7. Go to Administration > Biometric Device Profile and add a new Device Profile. Name the Profile, “Mifare
CSN or Biometrics”. Keep the Configuration Mode as Express and press Next.
8. Select “Wiegand Profile” and choose the Wiegand profile you have created i.e.“Controlsoft Mifare 34 Bit”.
Click Next.
9. Under Multi-Factor Mode, select “Custom”. Check “Biometrics” and “Mifare Classic”. Click Next.
10. Under Access Control Mode Settings, choose “Standalone” if you are using the reader as a Single Door
Controller, or Integrated if you are using it alongside an Access Control Unit.
11. Click Next until you see the 'Custom parameters' section.
ucc.per_user rules 2
ucc.user_recored_reference 1
sc.verify_csn_length 32
sc.verify_user_id 2
13. In Biometric Device, create a reader and use the new Biometric Device Profile.
3. Click Administration > User Policy. Add a new User Policy and give it a name. Under Wiegand Profile select
“Controlsoft Mifare 34 Bit”. For User Authentication Mode select the User Authentication mode you have set
up. Click Next, under “Finger Biometric Enrollment Minimum Fingers” select None. Click finish once complete.
4.
5. This is now ready to be set up along side the Identity Access system using Biobridge. This will mean the user
can either use their card or their biometrics.
2. Under MA Sigma, MA Sigma Lite, MA Sigma Lite+, MorphoWave Mode, select “Enabled”. Tick “Download
Identifier to Device”. Tick “Allow Start by Biometric” and “Allow Start by Contactless Card”. Click Finish once
complete.
3. Click Administration > User Policy. Add a new User Policy and give it a name. Under Wiegand Profile select
“Controlsoft Mifare 34 Bit”. For User Authentication Mode select the User Authentication mode you have set
up. Under “Finger Biometric Enrollment Minimum Fingers” select None. Click finish once complete.