This bulletin explains how to install and configure MorphoManager with Sigma series
readers for either Standalone mode or ACU mode (for use with access control systems).
Equipment required -
Installing MorphoManager -
First download the latest MorphoManager Server install file & the MorphoManager Client install
file from www.morphomanager.com
Once those 2 files are downloaded please run the MorphoManager Server install. By default the
Morpho server uses a SQL compact database unless you specify otherwise during the install.
(Speak to our support for assistance with SQL Express install if needed).
Install the MorphoManager client software on the same machine or a machine which can be
networked back over the LAN to the MorphoManager server.
Configuring Sigma Series readers for standalone mode (mag/strike locks) or ACU
Mode (iNet controller etc) -
2. When you log in for the first time you must register the software if prompted to -
Stand-alone mode with sigma series readers requires the door contact connections (10 &
12 on the pigtail) to be linked out if not used.
ACU Mode -
Set this to match your format required by your ACU controller (26bit etc) If your format isn't
listed, please contact controlsoft support
7. Click Next
8. Multi-factor mode keep as Biometric Only and click Next
9. Access control mode use the following setting for the Access control mode -
Integrated (default) = For use with Access control systems to enable the wiegand output
Stand-alone = For use with the onboard relay & RTE (if required) enabled by using the tick boxes
shown below -
10. If you require access schedules in Standalone mode, Click Next until you see Enable Access
Schedules tick this box then click finish.
13. Fill out the minimum information shown below then click Finish -
14. Wait for the reader to show online and then check the tasks all complete at the bottom of
the screen.
15. The reader will reboot during this time and once it's back online you can then continue.
16. For ACU mode, edit the default User Policy for the correct wiegand profile settings and click
finish, otherwise continue to step 17.
18. Fill out all the required details clicking Next through each screen, ensure if you are using ACU
mode to match the card number with the user in the access system.
19. Ensure your MSO 300/1300 USB enrollment reader is plugged into the machine, then click
on the index finger icons of each hand to enrol (minimum of 2 fingers per user), present the same
finger 4 times during enrollment.
https://desk.zoho.com/portal/controlsoft1/kb/articles/tech-bulletin-169-setting-up-morphomanager-
with-sigma-series-readers
20. Test the bio reader to ensure the enrollment has been successful and the door unlocks.