2. SHOP DRAWINGS WITH ERECTION AND PLACING DIAGRAMS OF ALL STRUCTURAL STEEL, MISCELLANEOUS IRON, PRE-CAST WF-1 WF-1
CONCRETE, ETC. SHALL BE SUBMITTED FOR ENGINEER'S APPROVAL BEFORE FABRICATION.
1 A B C A B C
3. CONTRACTOR SHALL VERIFY ALL DIMENSIONS BEFORE ALL WORK IS TO BEGIN, CHECK WITH MECHANICAL AND ELECTRICAL F1/C1 F1/C1 F1/C1
CONTRACTORS FOR CONDUITS, PIPE SLEEVES, ETC. TO BE EMBEDDED IN CONCRETE.
WF-1
4. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ADEQUATE SHORINGS AND BRACINGS OF THE STRUCTURE FOR DATE
ALL LOADS THAT MAYBE IMPOSED DURING CONSTRUCTION. WF-1
LAND USE & PLANNING
B. CONCRETE & REINFORCEMENT
1 C1 B1 (200x400) C1 B2(200x400) C1
1 B1 (200x400) B2(200x400)
1. ALL MATERIALS & WORKMANSHIP SHALL CONFORM WITH THE LATEST BUILDING CODE OF AMERICAN CONCRETE INSTITUTE
(ACI-318).
2
B11(200x400)
B13(200x400)
B12(200x400)
B11(200x400)
B13(200x400)
B12(200x400)
F1/C1 F1/C1 F1/C1
2. ALL CONCRETE SHALL DEVELOP A MINIMUM COMPRESSIVE STRENGTH AT THE END OF TWENTY EIGHT (28) DAYS WITH
CORRESPONDING MAXIMUM SIZE AGGREGATE & SLUPMS AS FOLLOWS: S1 S1 S1 S1
WF-1
LOCATION 28 DAYS STRENGTH MAX. SIZE AGG. MAX. SLUMP WF-1
3. ALL REINFORCEMENT BARS SHALL CONFORM TO ASTM A615 (PNS 49) GRADE 33 FOR DIA. 12 AND SMALLER BARS & GRADE 40 WF-1 2 C1 B3(200x400) PC1 B4(200x400) C1
2 B3(200x400) B4(200x400)
FOR DIA. 16 AND LARGER BARS. COLUMN HOOPS ARE ALL GRADE 33 BARS.
3
B15(200x400)
B16(200x400)
F1/C1
B15(200x400)
LINE & GRADE
B14(200x400)
4. IN GENERAL, THE LATEST EDITION OF ACI-315, MANUAL OF STANDARD PRACTICE DETAILING REINFORCED CONCRETE
B16(200x400)
B14(200x400)
F1/C1 F1/C1
STRUCTURES SHALL BE ADHERED TO, UNLESS OTHERWISE SHOWN OR NOTED.
S1 S1 S1 S1
5. MAINTAIN MINIMUM CONCRETE COVER FOR REINFORCING STEEL AS FOLLOWS: WF-1 WF-1
B18(200x400)
B18(200x400)
B17(200x400)
B17(200x400)
WHERE CONCRETE IS DEPOSITED WF-2 B7(200x400)
S2 S1 S1
6. SPLICES SHALL BE SECURELY WIRED TOGETHER AND SHALL LAP OR EXTEND IN ACCORDANCE WITH TABLE 1 (TABLE OF LAP F2/C2 F2/C2 F2/C2
SPLICE AND ANCHORAGE LENGTH) B8(200x400)
UNLESS OTHERWISE SHOWN ON DRAWINGS, SPLICES SHALL BE STAGGERED WHENEVER POSSIBLE. S2
7. ALL ANCHOR BOLTS, DOWELS. AND OTHER INSERTS, SHALL BE PROPERLY POSITIONED AND SECURED IN PLACE PRIOR TO 4 B9(200x400)
4 B10(200x400) ARCHITECTURAL
PLACING OF CONCRETE.
FOUNDATION PLAN C1 B10(200x400) C1 CS1
8. CONTRACTORS SHALL NOTE AND PROVIDE ALL MISCELLANEOUS CURBS, SILLS, STOOLS, EQUIPMENTS AND MECHANICAL BASES
THAT ARE REQUIRED BY THE ARCHITECTURAL, ELECTRICAL, AND MECHANICAL DRAWINGS.
4' C2 C2 C2
4'
9.ALL CONCRETE SHALL BE KEPT MOIST FOR A MINIMUM OF SEVEN (7) CONSECUTIVE DAYS IMMEDIATELY AFTER POURING BY THE
USE OF WET BURLAP, FOR SPRAYING, CURING COMPOUNDS OR OTHER APPROVED METHODS. UGF FRAMING PLAN ROOF DECK FRAMING PLAN
Footing Length
10. STRIPPING OF FORMS AND SHORES.
FOUNDATION----------------------------------------------------24 HRS
WALLS-------------------------------------------------------------18 HRS
C. FOUNDATION
1. FOUNDATION WAS DESIGNED USING AN ASSUMED ALLOWABLE SOIL BEARING CAPACITY OF 95.7 KPA.
Footing Width
2. FOUNDATION SHALL REST ON NATURAL SOIL, UNLESS OTHERWISE NOTED BY THE ENGINEER, NO PART OF THE FOUNDATION STRUCTURAL
SHALL REST ON FILL.
3. THE CONTRACTOR SHALL NOTIFY THE ENGINEER AFTER FOOTING EXCAVATION HAVE BEEN COMPLETED AND PRIOR TO
CONCRETING TO CONFIRM THE DESIGN SOIL BEARING CAPACITY.
4. THE CONTRACTOR SHALL PROVIDE FOR DESIGN AND INSTALLATION OF ALL CRIBBING, SHEATHING AND SHORING NECESSARY
TO SAFELY RETAIN EXCAVATION AND EARTH BANKS.
5. ALL ON-SITE WORKS SHALL BE AS PER RECOMMENDATION OF THE PROJECT SOIL ENGINEER.
3. LINTEL BEAMS OR LINTEL BLOCKS SHALL BEAR AT LEAST 8 INCHES (200MM) ON EACH SIDE OF MASONRY WALL OPENING.
12MM DIA SPACED @ 300 MM O.C. BW
200MM
5. BLOCK WALL REINFORCING BARS SHALL BE LAPPED A MINIMUM OF 30 BAR DIAMETERS WHERE SPLICED, HORIZONTAL/VERTICAL 600MM
D (Depth)
DOWELS FROM FOOTINGS, COLUMNS/WALLS OR SLABS SHALL EXTEND INTO THE BLOCK WALL A MINIMUM OF 30 BAR DIAMETERS
OR A MINIMUM OF 400 MM. WHICHEVER IS LONGER AND DOWELS TO MATCH VERTICAL REINFORCEMENTS OF WALL. MECHANICAL
6. ALL CELLS CONTAINING REINFORCING BARS OR INSERTS SHALL BE SOLIDLY FILLED WITH CONCRETE GROUT. (REFER TO WALL FOOTING DETAIL
SPECIFICATIONS)
36 1.43 0.61 0.48 2.40 1.70 2.0 1.40 8.000 1.20 1.05 FOOTING DETAIL COLUMN DETAIL
PREPARED BY: SEAL PRC ID: TITLE & LOCATION: OWNER: SHEET NO.:
TIN NO.:
GENEVIEVE G. GAYOSO
CIVIL ENGINEER
PTR NO.:
DATE:
PROPOSED MARY JANE P. LASTRA RES. BLDG.
SANTA MARIA, BULACAN
MARY JANE PETILO-LASTRA
S1 3