Characteristics Certifications
• Large Sensor Offering – Electrochemical, • Oil and Gas Industry
Catalytic and Infrared • Offshore Drilling
• Non-Intrusive Calibration • Utilities and Power
• Smart Sensor • Petrochemical Industry
• HART (optional) • Municipal Water and
• RS-485 Modbus • Waste Treatment
• Programmable Relays (optional) • Food and Beverage Production
• Dual Gas Sensing (optional)
3M Oldham iTrans 2
TM TM
Sensors
displayed immediately after each calibration.
Versatile housing.
• RS-485 Modbus
• Stainless Steel Enclosure (optional) The iTrans 2 can be configured to meet almost any
• Programmable Relays (optional) installation application.
• 3-wire, 4-wire Installations Common configurations includes:
• Dual Gas Sensing (optional) 3-Wire (4-20mA) Models - Allow for full utilization of the
• Remote Sensing (optional) Multiple Wiring iTrans 2‘s features and options and can be used with all
• Large Sensor Offering – Electrochemical, Catalytic and Options of the iTrans 2‘s sensors.
Easy to use
• Smart Sensor With the optional HART Communication Protocol, the
HART™
• Non-Intrusive Calibration Communication
iTrans 2 offers remote diagnostics, set-up or calibration
Ordering information
iTrans 2 offers a wide variety of sensor configurations and iTrans 2 Base Part Number: iTrans 2-ABCDEFG (sensor
relay options for maximum flexibility and affordability. Use options listed below) Magnetic calibration tool, and cali-
the following guide to select the options that best fit your bration
monitoring needs and applications. Oldham recommends cup are standard items with all iTrans 2 monitors.
that a fixed system application survey be completed to Questions? Visit us at http://gasdetection.3m.com
help provide the most accu- rate assessment of your
equipment requirements
d
ar
so ut
ut
r 2
bo
en tp
tp
2
n
1
rs u
ou
on
io
or
or
io
fo o
Example : iTrans 2 - 1C21241
at
e A
ns
at
ns
l
fig r 1
fig r 2
na
al m
m
ur
ur
se
se
An iTrans 2 with an on-board LEL (4-20 mA
on o
io
on o
C ens
Sc -20
20
C ens
pt
as
as
scale 0-100) and remote mount H2S (4-20 mA
4-
O
G
G
S
4
S
=
=
=
=
G
C
-
A B C D E F G
3 — Non-hazardous
2 — No Relay 2 — Explosion proof/
remote/ Duct 3 — NH3 2 — 0-100 3 — NH3 2 — 0-100
Module (Hart) remote*
mount*
4 — Explosion proof/ 3 — Non-hazardous
3 — With On-Board
On-Board with 4 — H2S 3 — 0-50 remote/ Duct 4 — H2S 3 — 0-50
Relays (Hart)
Splash Guard mount*
4 — Explosion proof/
5 — Explosion proof/
On-Board with
Remote with 5 — SO2 4 — 0-30 5 — SO2 4 — 0-30
Splash Guard**
Splash Guard*
5 — Explosion proof /
6 — Stainless Steel /
6 — NO2 5 — 0-10 Remote with Splash 6 — NO2 5 — 0-10
On-Board
Guard*
Hydrogen Chloride 0.2-30 ppm in 0.1 ppm increments Output Signal: + RS-485 Modbus (9600 baud)
Optional: HART Protocol
Phosphine 0-1 ppm in 0.01 ppm increments
Alarm relays 3 alarm relays (5 / Two user-programmable relays, SPST, N.O.
Nitrogen Dioxide 0.2-99.9 ppm in 0.1 ppm increments (opt) Amps at 30VDC)
One fault relay, SPST, N.C.
Nitric Oxide 0-999 ppm in 1 ppm increments Class I, Div 1, Groups B, C, D
CSAUS* Ex d IIB + H2 T5
Chlorine 0.2-99.9 ppm in 0.1 ppm increments C
As an ISO 9001 & ISO 14001 approved company, OLDHAM quality assurance programmes demand the continuous assessment and improvement of all OLDHAM products. Information in
this leaflet could thus change without notification and does not constitute a product specification. Please contact OLDHAM or their representative if you require more details.