Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Series 8008
E4
> Versions
– Control switch with
2, 3 or 4 pole
– Load switch 3 pole + 1
auxiliary contact
E4
> Rated operational voltage up
to 690 V AC
> Positive opening contacts E4
> Contacts suitable for EM-STOP
> Isolating characteristics
according to IEC/EN 60947-3
> Latching or spring-return E4
versions available
E4
www.stahl.de
E4
Series 8008 E4
18172E00
E4
The control switches series 8008 can be used for EMERGENCY
STOP functions according to IEC/EN 60204, DIN VDE 0113.
The switching function can be selected, it is available in latching or
spring-return version. E4
The load switches meet all requirements for use as motor or main
switch.
Class I E4
ATEX / IECEx (NEC 505) (NEC 506) Class I Class II Class III
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
For use x x For use in x x For use in x x x x
E4
Explosion Protection
Global (IECEx)
Gas and mining IECEx PTB 06.0010U
Ex db eb IIC Gb
Ex db eb I Mb E4
Europe (ATEX)
Gas and mining PTB 00 ATEX 1111 U
E II 2 G Ex db eb IIC Gb
E I M2 Ex db eb I Mb E4
Certifications and certificates
Certificates IECEx, ATEX, USA (UL), Canada (UL)
E4
WebCode 8008A
E4
2017-02-16·EK00·III·en Control Devices E4/1
Control switch/load disconnect switch
Series 8008
Selection Table
Version Switching arrangements Order number Weight
Assembly
Additional information
kg
002
01832E00
11 21 11 21
8008/2-005 0.128
45° X X 45° 135°
005
135°
12 22
12 22
07134E00
005
11 23 11 23 8008/2-016 0.128
45° X 45° 135°
016
135° X
12 24
12 24
08857E00
016
11 23 11 23 8008/2-016-AU 0.128
45° X 45° 135°
016
135° X
12 24
12 24
08857E00
016
Gold contacts
13 23
13 23 8008/2-025 0.128
45° 90°
45° 135°
90° X 025
135° X 14 24
14 24
08754E00
025
11 23
11 23 8008/2-027 0.128
45° X 90°
45° 135°
90° 0 27
135° X 12 24
12 24
08758E00
027
8008/2-033 0.128
08756E00
033
11 23
11 23 8008/2-034 0.128
45° 90°
68° 45° 135°
90° X 034 90°
135° X X 12 24
12 24
08766E00
034
11 23 8008/2-035 0.128
0°/360° X
60°
120° X
X
6x60°
11 23 E4
180° X 035
240° X
12 24
300° X
360°/0° X
E4
12 24
08760E00
035
13 23
13 23 8008/2-038 0.128
45° 90°
45° 135° 45°/90°
E4
90° X 038
135° X X 14 24
14 24
08767E00
038
0.128
E4
13 23
13 23 8008/2-038-AU
45° 90°
45° 135° 45°/90°
90° X 038
135° X X 14 24
14 24
08767E00
038
Gold contacts E4
13 23
13 23 8008/2-040 0.128
45° X 90°
45° 135°
90° 040 90°
135° X 14 24
14 24
E4
08859E00
040
13 23 13 23 8008/2-045 0.128
90° 90° 135° 90°
045
135° X X
14 24
14 24
10734E00 E4
045
11 23
11 23 8008/2-047 0.128
45° X 90°
45° 135° 45°/90°
90°
135° X
047
12 24 E4
12 24
09026E00
047
45°
13 21
X X
45°
90°
135°90°/135°
13 21 8008/2-048 0.128 E4
90° X 047
135° 14 22
14 22
09027E00
048
E4
13 23
13 21 8008/2-051 0.128
45° X 90°
45° 135°90°/135°
90° 051
135° X 14 22
14 24
051
08770E00
E4
E4
2017-02-16·EK00·III·en Control Devices E4/3
Control switch/load disconnect switch
Series 8008
Selection Table
Version Switching arrangements Order number Weight
Assembly
Additional information
kg
11 23 11 23 8008/2-053 0.128
90° X 90° 135° 90°
053
135° X
12 24
12 24
06083E00
053
11 23
8008/2-1261 0.128
0°/360° X
60° X
11 23
120° X 6x60°
180° X 1261
240° X
12 24
300° X
360°/0° X
12 24
07826E00
8008/2-1260 0.128
07828E00
102
01833E00
13 23 31 41 13 23 31 41 8008/2-106 0.186
45° X X 45° 135°
106
135° X X
14 24 32 42
14 24 32 42
08861E00
106
13 23 31 41 13 23 31 41 8008/2-107 0.186
45° X X 45° 135°
107
135° X X
14 24 32 42
14 24 32 42
10745E00
107
13 23 33 43 13 23 33 43 8008/2-108 0.186
45° 45° 135°
108
135° X X X X
14 24 34 44
14 24 34 44
10746E00
108
11 23 33 43
8008/2-110 0.186
0° X 11 23 33 43
45°
90°
X
X
110
0°
45° 90°
135°
E4
12 24 34 44
135° X
12 24 34 44
08862E00
110
E4
13 21 33 43
13 21 33 43 8008/2-113 0.186
45° X 90°
45° 135°
90° X
135° X X 14 22 34 44
14 22 34 44
E4
10747E00
113
11 23 31 43
90°
11 23 31 43 8008/2-119 0.186
45° X X 45° 135°
90° 119
E4
135° X X 12 24 32 44
12 24 32 44
08768E00
119
13 21 31 43
45° 8008/2-124 0.186
0°
45°
X
X
X
68° 124
0°
90°
135°
0°/90°
13 21 31 43
E4
90° X X
14 22 32 44
135° X X X
14 22 32 44
08627E00
124
*actuation point E4
13 23 33 43
90° 13 23 33 43 8008/2-127 0.186
45° X X 45° 135°
90° 90°
127
135° X X 14 24 34 44
14 24 34 44
127
07368E00
E4
11 23 33 41 8008/2-130 0.186
0° X X X 11 23 33 41
45° 90°
45° X X 0° 135°0°/45°/90°
90°
135° X
130
12 24 34 42 E4
12 24 34 42
10839E00
130
45°
11 23 33 43
X 45°
90°
135°
11 23 33 43 8008/2-139 0.186 E4
139 45°/90°
90° X X
135° X X 12 24 34 44
12 24 34 44
07369E00
139
E4
13 21 33
90° 13 21 33 8008/2-145 0.186
45° X 45° 135°
90° X 145 90°/135°
135° X 14 22 34
14 22 34
10789E00 E4
145
E4
2017-02-16·EK00·III·en Control Devices E4/5
Control switch/load disconnect switch
Series 8008
Selection Table
Version Switching arrangements Order number Weight
Assembly
Additional information
kg
13 23 31 41 8008/2-148 0.186
0° X X 13 23 31 41
45° 90°
45° 0° 135°0°/45°/90°
148
90° X
14 24 32 42
135° X X
14 24 32 42
10926E00
148
13 21 33 41
90°
13 21 33 41 8008/2-162 0.186
45° X X 45° 135° 90°
162
90° X X
14 22 34 42
135° X X
14 22 34 42
07370E00
162
6 4 2*
90°
6 4 2 8008/2-163 0.186
45° X 45° 135° 90°
163
90° X
5 6 1
135° X X
5 3 1*
02449E00
163
Attention! The contact 2-1 is a normally open contact with positive
closing
11 21 33 43
11 21 33 43 8008/2-170 0.186
45° X X 90°
45° 135° 45°/90°
90° X X 170
135° X X 12 22 34 44
12 22 34 44
10840E00
170
13 23 33 PE
8008/2-196 0.186
0°/360°
90° 180° 13 23 33 PE
90° X X X
0° 270°
180° 196
270° X X X 14 24 34 N
360°/0°
14 24 34 N
02450E00
196
6 4 2
90°
6 4 2 8008/2-197 0.186
45° X 45° 135°45°/90°
197
90° X
5 3 1
135° X X
5 3 1
02451E00
197
Attention! The contact 2-1 is a normally open contact with positive
closing
13 23 31 43
8008/2-1114 0.186
0° X 45° 90° 13 23 31 43
45° X 0° 135°
0°/45°/90°
1114
90° X
14 24 32 44
135° X X
14 24 32 44
10927E00
1114
8008/2-1136 0.186
10833E00
1136
1 3 5 1 3 5 8008/2-1140 0.186
0° 0° 90°
90° X
2
X X
4 6
1140
2 4 6 E4
05697E00
1140
11 23 33 43
8008/2-1168 0.186
0°
45°
X
X 0°
45° 90°
135°
0°/45°/90°
11 23 33 43 E4
1168
90° X
12 24 34 44
135° X
12 24 34 44
10835E00
1168
E4
11 23 31 43
90° 11 23 31 43 8008/2-1178 0.186
45° X X 45° 135°
45°/135°
1178
90° X X
12 24 32 44
135° X
12 24 32 44
10929E00 E4
1178
13 21 33 43
8008/2-1207 0.186
0° X X 45° 90° 13 21 33 43
E4
45° X 0° 135°
45°/90°/135°
1207
90° X
14 22 34 44
135° X
14 22 34 44
10928E00
1207
E4
E4
E4
E4
E4
E4
E4
2017-02-16·EK00·III·en Control Devices E4/7
Control switch/load disconnect switch
Series 8008
Selection Table
Version Switching arrangements Order number Weight
Assembly
Additional information
kg
10836E00
602
5 13 1 3 5 13 1 3 8008/2-603 0.225
45° 45° 135°
X X X X 603
135°
6 14 2 4
01833E00 6 14 2 4
10837E00
603
8008/2-613 0.225
10838E00
613
5 13 1 3 5 13 1 3 8008/2-6803-C1211 0.225
45° 45° 135°
X X X X 803
135°
6 14 2 4
6 14 2 4
11005E00
Note The standard contact arrangements are examples, other 3 or 4 pole versions are available
Technical Data
Electrical data
Rated insulation voltage max. 690 V AC
Rated frequency 50 / 60 Hz
Rated operational voltage max. 690 V AC / 230 V DC
Rated impulse withstand max. 6 kV (load disconnect switch), 4 kV (control switch)
voltage
Rated operational current max. 16 A
Contacts max. 4-pole; NC with positive opening for EM-STOP
E4
E4
E4
2017-02-16·EK00·III·en Control Devices E4/9
Control switch/load disconnect switch
Series 8008
04220E00
04420E00
8008/2-0.. 8008/2-1..
15087E00
8008/2-6..
Ø39, can be locked with with standard seal for 227391 0.040
one lock, 45° position up to -20 °C
Ø39, can be locked with with silicone seal for 227392 0.040
one lock, 45° position up to -60 °C
Black handle, black protec- with standard seal for up to 227225 0.040
tive collar, Ø65, handle in -20 °C
45° position, uninstalled E4
Black handle, black protec- with silicone seal for up to - 227226 0.040
tive collar, Ø65, handle in 60 °C
45° position, uninstalled
E4
Red handle, yellow protec- with silicone seal for 253175
tive collar, Ø65, handle in up to -60 °C
90° position, pre-installed
with 0/OFF I/ON label
E4
We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice.
The illustrations cannot be considered binding.
E4
2017-02-16·EK00·III·en Control Devices E4/11