KOYO escalator control system

electrical appliance schematic drawing


---wiring diagram : KTFV28104Y
Drive mode: VVVF
Collicate: KYM08E301
Voltage: AC380~415V
KOYO ELEVATOR CO.,LTD.
KOYO electrical appliance schematic sample centent (KTFV28104Y)
Page
number Drawing number Drawing caption
P1 KY-FEV-ZQDVA-02Y Converter control loop-YASKAW-V/A1000A
P2 KY-FEV-KZD1A-02Y Control power loop 1
P3 KY-FEV-KZD2-02Y Control power loop 2
P4 KY-FEV-AQHL-02Y Safety loop
P5 KY-FEV-ZBSR1-04Y Control board I/O loop 1
P6 KY-FEV-ZBSR2-04Y Control board I/O loop 2
P7 KY-FEV-ZBSR3-04Y Control board I/O loop 3
P8 KY-FEV-KZBJK-02Y Extention input loop and remote control loop
P9 KY-FEV-FJGNH-02Y Additive function
P10 KY-FEV-ZQDGN-02Y Automatic startup detection
P11 KY-FEV-FJZMH-04Y Additive lighting loop
P12 KY-FEV-FJJRH-02Y Additive heating loop
P13 KY-FEV-ZLJDL-02Y Main cable
P14 KY-FEV-SWDL1-02Y Upper controller cable 1
P15 KY-FEV-SWDL2-02Y Upper controller cable 2
P16 KY-FEV-SWDL3-02Y Upper controller cable 3
P17 KY-FEV-XWDL1-02Y Under controller cable 1
P18 KY-FEV-XWDL2-02Y Under controller cable 2
P19 KY-FEV-JXDZP-02Y Terminal board
P20 KY-FEV-FTFXT-02Y Lay out drawing
P21 KY-FEV-YJDM1-02Y Code NO. for components 1
P22 KY-FEV-YJDM2-02Y Code NO. for components 2
Power box
(provided by user)
YASKAWA Used subject to
double driving
V/A1000A
KA1
KYM08E301
BU
Note:
Converter feedback 1、V1000A:7.5~18.5kw;A1000A:22kw above
input
2、A1000A inverter>=45kw,braking resistor connect brake
unit,brake unit join (+1)and (-) terminal,when <45kw,resistor
join B1 and B2 directly
Converter control loop-
KOYO ELEVATOR CO.,LTD. YASKAW-V/A1000A
Control transformer
KOYO ELEVATOR CO.,LTD. Control power loop 1
Used subject to
double driving
Used by step lighting
Used by step lighting
Used by comb lighting
Used by emergency brake
KOYO ELEVATOR CO.,LTD. Control power loop 2
Upper emergency
Phase relay Hot overload relay Hot overload relay stop button Remote emergency stop button Main-frame protection switch
CST1 CST2
Left host break chain switch Upper step switch Upper decking switch Upper skirt stop button
Right host break chain switch Upper left entrance switch Upper right entrance switch Upper combs switch
Under skirt stop button Under emergency stop button Upper combs switch
Middle stop button
Under decking switch Under step switch Under left step chain switch Under left step chain switch
Under right combs switch Under left combs switch Under right entrance switch Under left entrance switch
Water level detection switch
4 12
Short circuit subject to no
inspection of water level Short circuit subject Short circuit subject Short circuit subject
to no emergency brake to no fire control to no smog alarm
KOYO ELEVATOR CO.,LTD. Safety loop
KOYO ELEVATOR CO.,LTD. Control board I/O loop 1
Mark3
Mark2
Mark2
Mark2
Mark1
Illustration
Mark1:used when operating direction displayed
Mark2:used subject to double driving
Mark3:used middle stop button
KOYO ELEVATOR CO.,LTD. Control board I/O loop 2
STOP INSP
CIRCUIT BOARD
DOWNSIDE DISPLAY
STOP INSP
KOYO ELEVATOR CO.,LTD. Control board I/O loop 3
PC REMOTE MONITORING SYSTEM
TERMINALS REMOTE CONTROL AND DISPLAY CIRCUIT BOARD REMOTE DISPLAY
UP display Down display Stop Start

Yellow

Purple

Brown
Green

White

Black
Gray
Blue
Remote fault
Stop INS display
To supervisory room
Extention input loop and
KOYO ELEVATOR CO.,LTD. remote control loop
DIRECTION DISPLAYED
Allow
Forbidden
Mark1
INSPECTION BOX
FIRE PROTECTION
SFL1 SFL2
Fire protecting switch
provided by clients
Mark2
SMOG ALARM FUNCTION
Mark3
Mark4
Illustration
Mark1:used when operating direction displayed
Mark2:used when equipped with fire protection
Mark3:used as smog alarm function
Mark4:wiring diagram of inspection box
KOYO ELEVATOR CO.,LTD. Additive function
LIGHT RAYS SENSORS (PE12DF) MICROWAVE SENSORS(EM-D111L&EM-D111R)
Brown
Blue
White Black
Transimiter
Brown
Blue
Receiver
White Black
Brown
Blue
White Black
Transimiter
Brown
Blue
Receiver
White Black
LIGHT RAYS SENSORS(PT12T-6M-E8&PT12T-6M-ND)
MICROWAVE SENSORS(EMA-175HD)
Blue Blue
Black Black
Brown Brown
Blue Blue
Black Black
Brown Brown
KOYO ELEVATOR CO.,LTD. Automatic startup detection
Left handrail lighting
Right handrail lighting
Handrail lighting power box
Mark1
Key switch
Mark2
Skirt and truss lighting power box
Terminals
Left skirt lighting
NO. Tag
Right skirt lighting
Left truss lighting
Illustration
Mark1:lighting can be controlled by key switch Right truss lighting
Mark2:lighting works when escalator is running
KOYO ELEVATOR CO.,LTD. Additive lighting loop
Used for comb heating loop only Left handrail heating device
Used for truss and handrail Right handrail heating device
heating loop power supplyed
by users
Comb heating device Truss heating device Comb heating device
upper Under
Terminals
NO. Tag
Note:Used for half-outdoor escalator
KOYO ELEVATOR CO.,LTD. Additive heating loop
Upper Plug Board
Wire NO.
Function NO.
(Z01) RVV24*0.75 Lower Plug Board (Z02) RVV24*0.75
Main cable (Z01) Main cable (Z02)
Insert Pin Wire NO. Remark Insert Pin Wire NO. Remark Insert Pin Wire NO. Remark Insert Pin Wire NO. Remark
Black 1 Under up start signal Black 13 Under fault display signal 1 Black 1 Under left entrance switch signal Black 13 7#
Black 2 Under down start signal Black 14 Under fault display signal 2 Black 2 Under right entrance switch signal Black 14 8#
Black 3 6# Black 15 Under fault display signal 3 Black 3 Under left comb switch signal Black 15 AC220V (L)
Black 4 Under inspection up start signal Black 16 Under fault display signal 4 Black 4 Under right comb switch signal Black 16 AC220V (N)
Black 5 Under inspection down start signal Black 17 Under fault display signal 5 Black 5 Under left skirt panel switch signal Black 17
Step and comb lighting power
Black 6 Under inspection start signal (COM) Black 18 Under fault display signal 6 Black 6 Under right skirt panel switch signal Black 18
Black 7 Under emergency stop signal Black 19 4# Black 7 Black 19 AC220V (L) control power
Under safety loop
Black 8 Inspection/auto signal Black 20 5# Black 8 Black 20 AC220V (N) control power
Black 9 Under DC24V(+) Black 21 Left handrail monitor Black 9 Under left step chain switch signal Black 21 Handrail broken protect left
Black 10 Under DC24V(-) Black 22 Right handrail monitor Black 10 Under right step chain switch signal Black 22 Handrail broken protect right
Black 11 Under direction display (running) Black 23 Under missing step monitor Black 11 Under step broken switch signal Black 23 2#
Black 12 Under direction display (forbidden) Black 24 Under automatic start signal Black 12 1# Black 24 3#
KOYO ELEVATOR CO.,LTD. Main cable
Black

Purple
Brown

Gray

Blue

Green

Yellow
White
STOP
INS

SAU1: ESU: SE1L: SP1L: SP1R: SP3U: SP4L: SP4R:


Upper start switch Upper fault display left host speed test left host break check right host break check upper step switch upper left entrance upper right entrance
photoelectricity switch switch switch switch
SE1R: SPBL: SPBR: SPJB: SP8L: SP8R:
right host speed left host wrench check right host wrench check emergency check switch upper left skirt switch upper right skirt switch
test photoelectricity switch switch
Short circuit subject to no function
KOYO ELEVATOR CO.,LTD. Upper controller cable 1
SP6L: SP6R: SAT1U: SPQU: EOL: LZ: EL2U:upper step light BWL:brake wear left
upper left combs upper right combs upper stop button upper decking switch oil pump mergency brake
switch switch washer EL3U:upper comb light BWR:brake wear right
BELL: SPBJ: M2R:
alarm bell machine protective right motor brake power FAN2:inverter box fan
guard switch
Short circuit subject to no function
KOYO ELEVATOR CO.,LTD. Upper controller cable 2
Red

Black

Black

Yellow
Red

Yellow

SE3: SAT2: MSU: ELU: KAY: Frequency converter:


upper automatic start middle stop button missing step monitor upper running display fog monitor YASKAW-V/A1000A
photoelectricity upper
SRP: M2L:
reverse protect brake power left motor
Short circuit subject to no function
KOYO ELEVATOR CO.,LTD. Upper controller cable 3
Black

Purple
Brown

Gray

Blue

Green

Yellow
White
STOP
INS

SAD1: ESD: SE2L: SP2L: SP2L: SP3D: SP5L: SP5R:


under key switch under fault display left handrail speed-test left step chain switch right step chain under step switch under left entrance under right entrance
forrunning start switch switch switch
SE2R: SP9L: SP9L:
right handrail speed-test under left skirt switch under right skirt
switch
KOYO ELEVATOR CO.,LTD. Under controller cable 1
Red

Black

Black

Yellow
Red

Yellow
SP7L: SP7R: SAT1D: SPQD: SE4: EL2D: ELD: MSD: HBL:
under left combs under right combs under stop button under decking under automatic start under step light under running missing step handrail broken protect
switch switch switch photoelectricity display monitor upper left
KAS: EL3D: HBR:
Inspection of water under comb light handrail broken protect
level right
KOYO ELEVATOR CO.,LTD. Under controller cable 2
Power terminal board
Power terminal board Small terminal board
Safe loop
Remote monitoring terminal board
Frequency converter Machine room
power
Used subject to
double driving
Up display Down display Stop Start
Upper controller box
Small terminal board
Lower controller box
KOYO ELEVATOR CO.,LTD. Terminal board
KOYO ELEVATOR CO.,LTD. Lay out drawing
KOYO ELEVATOR CO.,LTD. Code NO. for components 1
KOYO ELEVATOR CO.,LTD. Code NO. for components 2