Economic Self-Tune PID This brief manual is primarily meant for quick reference to wiring connections
Temperature Controller and parameter searching. For more details on operation and application;
please log on to www.ppiindia.net
INPUT / OUTPUT CONFIGURATION PARAMETERS : PAGE - 12 SUPERVISORY PARAMETERS : PAGE - 13 Temperature Error Indications
Settings Settings Message Temperature Error Type
- SSR
Parameters (Default Value) Parameters (Default Value)
AC SUPPLY
Over-range
CONTROL
85 ~ 265 V
OUTPUT
Input Type Refer Table 4.2 for various Self-Tune (Temperature above Max. Range) 9 18
N
Yes
available 'Input Types' Command
along with their respective Under-range
8 17
+
No
L
Ranges and Resolutions. (Temperature below Min. Range)
(Default : No)
(Default : Type K) Open 7 16
Overshoot Inhibit (Thermocouple / RTD broken)
Control Logic Disable
Reverse Enable / Disable
6 15
Enable Keys Operation
Direct
(Default : Disable) 5 Omni 96 14
(Default : Reverse) Symbol Key Function
Overshoot Inhibit
Setpoint Low Min. Range to Setpoint Factor 1.0 to 2.0 4 13
High for the selected Input type (Default : 1.2) PAGE Press to enter or exit set-up mode.
RELAY NO C NC
3 12
CONTROL
(Default : Min. Range for
OUTPUT
the selected Input Type)
INPUT
Press to decrease the parameter
Setpoint Low to Max. value. Pressing once decreases the 2 11
Setpoint High SETPOINT LOCKING : PAGE - 0 DOWN
Range for the selected value by one count; keeping pressed
Input type Settings speeds up the change. 1 10
Parameters
Pt100
(Default : Max. Range for
T/C
(Default Value)
the selected Input Type) Press to increase the parameter
Offset for Setpoint Locking value. Pressing once increases the
No UP
Measured Temp. -1999 to 9999 or value by one count; keeping pressed
-199.9 to 999.9 Yes speeds up the change.
(Default : 0)
(Default : No)
Digital Filter Press to store the set parameter value
0.5 to 25.0 Seconds ENTER and to scroll to the next parameter on
(in steps of 0.5 Seconds) the PAGE.
(Default : 1.0) TABLE- 1
Option Range (Min. to Max.) Resolution
Control Output Relay (Default)
Type
SSR 0 to +960°C 1°C ELECTRICAL CONNECTIONS
J Type T/C
SSR
-200 to +1375°C 1°C
85~265
CONTROL
PID CONTROL PARAMETERS : PAGE - 10
OUTPUT
K Type T/C 5 10
VAC
Settings 4 9
NO C NC L
Parameters (Default Value)
-199 to +600°C 1°C 3 8
RTD Pt100
CONTROL
CONTROL MODE Omni
OUTPUT
On-Off
2 7
INPUT
PID (Default)
-199.9 to +600.0°C 0.1°C 1 6
RTD Pt100
Pt100
T/C
RELAY
HYSTERESIS 1 to 999 or 0.1 to 99.9
(Default : 2 or 0.2)
FRONT PANEL LAYOUT
Compressor 0 to 600 Sec.
Time Delay FRONT PANEL
+ - SSR
PPI
OUTPUT
Omni
6 12
Upper Readout
OUTPUT AC SUPPLY
CONTROL 85 ~ 265 V
Cycle Time 0.5 to 120.0 Seconds
5 11
N
(in steps of 0.5 secs.)
(Default : 20.0 sec) Lower Readout
4 10 L
Proportional Band Output status Omni 72 101, Diamond Industrial Estate, Navghar,
NC
OP
0.1 to 999.9 Indicator 3 9
(Default : 10.0) Vasai Road (E), Dist. Palghar - 401 210.
PAGE Key 2 8
-
ENTER Key
C
INPUT
1 7
+
09321985369
May 2019
Derivative Time 0 to 250 Seconds E: sales@ppiindia.net,
(Default : 25 sec)
support@ppiindia.net