SAUDI ARAMCO INSPECTION CHECKLIST
Pre-pour Inspection for Type I - V Fences SAIC-M-1004 30-Apr-17 CIVIL-
PROJECT TITLE WBS / BI / JO NUMBER CONTRACTOR / SUBCONTRACTOR

EQUIPMENT ID NUMBER(S) EQUIPMENT DESCRIPTION EQPT CODE SYSTEM ID. PLANT NO.

LAYOUT DRAWING NUMBER REV. NO. PURCHASE ORDER NUMBER EC / PMCC / MCC NO.

SCHEDULED INSPECTION DATE & TIME ACTUAL INSPECTION DATE & TIME QUANTITY INSP. MH's SPENT TRAVEL TIME
SAUDI ARAMCO USE ONLY
SAUDI ARAMCO TIP NUMBER SAUDI ARAMCO ACTIVITY NUMBER WORK PERMIT REQUIRED?

SAUDI ARAMCO INSPECTION LEVEL CONTRACTOR INSPECTION LEVEL

ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.

Reinforcing bars for fence anchors shall be prefabricated of 8mm AA-036680


A1
diameter concrete reinforcing bars. Sht. No.1

Dimensions of Footings:
Type of post Diameter of Footing Height of
Footing
Corner Post 300 mm 1075 mm
End Post 300 mm 1075 mm AC-036680
A2
Gate Post 300 mm 1075 mm Sht. No.1
Line Post 250 mm 1075 mm
Brace Post 250 mm 940 mm

Dimensions of Footings: Type VI Fence for On-shore Helipad


Type of post Dia. of Footing Height of Footing Dia. of Posts
Corner Post 300 mm 650mm 73mm O.D.
Gate Post 300 mm 650 mm 73mm O.D. AC-036681
A3
Line Post 250 mm 650 mm 60mm O.D. Sht. No. 1

Brace Post 250 mm 630 mm 41mm O.D.

The cover of the concrete to the reinforcing bars shall not be less AA-036680
A4
than 75mm for fence anchor blocks except for top protrusions. Sht. No. 1

Table 3 - Applicable Gate Sizes


Fence Gate Walk Width Overall Gate Frame Gatepost
Type Type or Drive Opening Height Extension Size
I, II, III A Walk 1200 2450 No 73
IV, V
B Drive 4000 2800 Yes 102
I, II, III, IV C Drive 7300 2800 Yes 102
V D Drive 4000 2450 No 102
SAES-M-006
E Drive 7300 2450 No 102
Para. 4.12 &
Table 4 - Post Lenghts
A5 4.13 and AA-
Fence Type I II III IV V
036680
Walk Gate 3400 3400 3400 3400 3400
Sht. No. 1
Drive Gate 3900 3900 3900 3900 3400
Line 3400 3400 3400 3400 3400
Corner/End 3400 3400 3400 3400 3400
Brace 2900 2900 2900 2900 2900
Note: Brace post diameter = 41mm
All dimensions are in millimeter
Post length includes 975mm extension in the footing.
Tolerance in length = plus or minus 12mm

Formwork when used shall be constructed so that they remain rigid


during the placing and compaction of the concrete to prevent the loss SAES-Q-001
A6
of water, grout or mortar from the concrete. (ACI 318, Sec. 6.1.2 & Sec. 8
6.1.3)

Saudi Aramco: Company General Use


SAUDI ARAMCO ID/PIEU - 30-Apr-2017 - REV. 2015.03.00 (Standards Cutoff - March 2015) Rev. 2015.03.00 31-Mar-15
SAIC NUMBER DATE APPROVED QR NUMBER
SAUDI ARAMCO INSPECTION CHECKLIST
Pre-pour Inspection for Type I - V Fences SAIC-M-1004 30-Apr-17 CIVIL-
PROJECT TITLE WBS / BI / JO NUMBER CONTRACTOR / SUBCONTRACTOR

ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.

Terminal Posts shall be provided at fence corners, ends, either side


of gates, fence tensioning locations or every 90m on center AB-036677
A7
maximum; They shall have a brace rail and diagonal truss rod Sht. No. 1
spanning to the adjacent post.

Entering point of galvanized post or brace into the concrete shall be AA-036680
A8 coated with one coat of paint conforming to APCS-113 or APCS-22. Sht. No.1
The area affected shall be cleaned with wire brush or light sanding. Note # 2

Paint or treatment at the entering point shall extend 25mm above the AC-036681
A9
concrete and 125mm into the concrete. Sht. No. 1

Type I, II, III, IV and V fence posts shall be extend at least 975mm
into concrete footings and have 100mm concrete footing cast below AA-036680
A10
their ends except special gate posts which shall extend a minimum Sht. No.1
of 1220mm into the concrete.

Type VI corner and gate posts shall be extend 450mm into the
AC-036681
A11 concrete, line posts 550mm into the concrete and brace posts
Sht. No. 1
530mm into the concrete.

AC-036680,
The minimum cover at the bottom of all Posts shall be 100mm,
Sht.1
A12 except type IV corner and gate posts, which shall have 200mm's
& AC-036681,
concrete cover. (SASD AC-036680, Sht. 1 and AC-036681, Sht. 1)
Sht. 1

The minimum cover on all sides of the foundations and anchor block AC-036680
A13
shall be 75mm. Sht. No.1

REMARKS:

REFERENCE DOCUMENTS:
1- SAES-Q-001 -- Criteria for Design and Construction of Concrete Structures, 15 May 2010
2- SAES-M-006 -- Saudi Aramco Security and General Purpose Fencing, 04 July 2010
3- AB-036677, Sht. 1 -- An Overview(Architectural), Saudi Aramco Security and General Purpose Fencing, 01 April 1990
4- AC-036681, Sht. 1 -- Perimeter Fencing for On-Shore Helipads, Footing Details, Type IV Fence, 01 July 1992
5- AC-036680, Sht. 1 -- Saudi Aramco Security and General Purpose Fencing, Footing Details, 01 April 1997

Contractor / Third-Party Saudi Aramco


Construction Representative* PMT Representative
Work is Complete and Ready for Inspection: T&I Witnessed QC Record Reviewed Work Verified
Name, Initials and Date: Name, Initials and Date:

QC Inspector PID Representative


Performed Inspection Work / Rework May Proceed T&I Witnessed QC Record Reviewed Work Verified
Name, Initials and Date: Name, Initials and Date:

QC Supervisor Proponent and Others


Quality Record Approved: T&I Witnessed QC Record Reviewed Work Verified
Name, Organization,
Name, Sign and Date:
Initials and Date: