Sei sulla pagina 1di 4

SEN01663-01 40 Troubleshooting

Failure code [2C4MNX] (Retarder cooling oil filter: Clogging) 1


Action code Failure code Retarder cooling oil filter: Clogging
Trouble
E01 2C4MNX (Retarder controller system)
Contents of
• The retarder cooling oil filter signal circuit was open (disconnected from ground circuit).
trouble
Action of
• None in particular
controller
Problem that
appears on • If the retarder is used for long hours, it may be seized.
machine
Related
information

Cause Standard value in normal state/Remarks on troubleshooting


Retarder cooling oil filter is
1 The oil filter is probably clogged.
clogged
1) Turn the starting switch OFF.
2) Disconnect connector BCF.
Defective switch for the BCF Oil filter Resistance
2 retarder cooling oil filter
clogging When normal Max. 1 z
Between (1) – (2) When the clogging
Min. 1 Mz
switch is open
Possible causes
and standard 1) Turn the starting switch OFF.
Disconnection in wiring 2) Disconnect connector BRC2 and BRC1.
value in normal harness
state 3 3) Connect T-branch to BRC1 and BRC2 (female).
(Disconnection or defective
contact) Wiring harness between BRC2 (female) Resis-
Max. 1 z
(17) – BRC1 (female) (6) tance
1) Turn the starting switch OFF.
2) Connect T-branch to connector BRC2.
3) Turn the starting switch ON.
4 Defective retarder controller BRC2 Oil filter Voltage
When normal Max. 1 V
Between (17) –
chassis ground When the clogging
20 – 30 V
switch is open

1 HD465-7E0, HD605-7E0
40 Troubleshooting SEN01663-01

Circuit diagram related

HD465-7E0, HD605-7E0 2
SEN01663-01 40 Troubleshooting

Failure code [6014NX] (Hydraulic oil filter: Clogging) 1


Action code Failure code Hydraulic oil filter: Clogging
Trouble
E01 6014NX (Retarder controller system)
Contents of
• The oil filter signal circuit was open (disconnected from ground circuit).
trouble
Action of
• None in particular
controller
Problem that
appears on • Each pump may be seized if they are used for long time.
machine
Related
information

Cause Standard value in normal state/Remarks on troubleshooting


1 Clogging of hydraulic oil filter The oil filter is probably clogged.
1) Turn the starting switch OFF.
2) Disconnect connector HDF.
Defective switch for the HDF Oil filter Resistance
2
hydraulic oil filter clogging When normal Max. 1 z
Between (1) – (2) When the clogging
Min. 1 Mz
switch is open
Possible causes 1) Turn the starting switch OFF.
and standard Disconnection in wiring 2) Disconnect connector BRC2 and BRC1.
value in normal harness 3) Connect T-branch to BRC1 and BRC2 (female).
3
state (Disconnection or defective
contact) Wiring harness between BRC2 (female) (2) Resis-
Max. 1 z
–BRC1 (female) (6) tance
1) Turn the starting switch OFF.
2) Connect T-branch to connector BRC2.
3) Turn the starting switch ON.
4 Defective retarder controller BRC2 Oil filter Voltage
When normal Max. 1 V
Between (2) –
chassis ground When the clogging
20 – 30 V
switch is open

3 HD465-7E0, HD605-7E0
40 Troubleshooting SEN01663-01

Circuit diagram related

HD465-7E0, HD605-7E0 4