Sei sulla pagina 1di 8

Project

Reference code
Design office
Person in charge
Construction Office
Person in charge

Base material Installation


No stand-off Installation.
Uncracked Concrete
Thickness of base material 250 mm Anchor plate
Strength Class C20/25 Assumed rigid plate
fck,cube 25 N/mm2 Thickness of the plate 20 mm
Plate shape Rectangle
Side length 400 X 400 mm

Plate vertex Anchors Position

Vertex x y Anchor x y Slotted -x Slotted -y


1 -200.0 -200.0 1 -135.0 135.0
2 -200.0 200.0 2 135.0 135.0
3 200.0 200.0 3 -135.0 -135.0
4 200.0 -200.0 4 135.0 -135.0

= Slotted

Profile
Selected Profile No Profile has been applied
Eccentricity X: 0.0 mm
Y: 0.0 mm

Selected Products
Anchor (name) ZJE01 - Wedge anchor
Approval ETA 13/1012
Size
Article code ZJE0120170

Tecfi Anchor Design Software


20/08/2019 Page: 1 / 8
v. 3.0.3.817 - Database 85.6.2255171556
Project

Reference code
Design office
Person in charge
Construction Office
Person in charge

Anchor data
d Anchor/thread diameter: 20.0 mm tfix Thickness of fixture: 20.0 mm
dnom Outside diameter of anchor: 20.0 mm SW Spanner: 30.0 mm
d0 Drill hole diameter: 20.0 mm Tinst Max setting torque 240.0 Nm
h1 Depth of drilled hole: 135.0 mm
hnom Setting depth: 125.0 mm
hef Effective anchorage depth: 103.0 mm
df Diameter of clearance hole in fixture: 22.0 mm

Wedge anchor in carbon steel, with nut and washer, zinc plated, ETA-CE Opt.7 certified

Tecfi Anchor Design Software


20/08/2019 Page: 2 / 8
v. 3.0.3.817 - Database 85.6.2255171556
Project

Reference code
Design office
Person in charge
Construction Office
Person in charge

Input Data
Tension Bending Reinforcement
NSd,Z -115.00 kN MSd,X -25.39 kN·m Diameter 25 mm
Shear MSd,Y 0.00 kN·m Distance rebars 200 mm
VSd,X 0.00 kN Torsion Distance stirrups 200 mm
VSd,Y 15.86 kN MSd,Z 0.00 kN·m Edge reinforcement No
Edges
CXp ∞ mm
CXn ∞ mm
CYp ∞ mm
CYn ∞ mm

Tecfi Anchor Design Software


20/08/2019 Page: 3 / 8
v. 3.0.3.817 - Database 85.6.2255171556
Project

Reference code
Design office
Person in charge
Construction Office
Person in charge

Calculated design loads on anchor(s)

Tension force Shear force Shear force (x) Shear force (y)
Anchor
[kN] [kN] [kN] [kN]
1 0.00 3.96 0.00 3.96
2 0.00 3.96 0.00 3.96
3 13.27 3.96 0.00 3.96
4 13.27 3.96 0.00 3.96

Resultant tension force: 26.53 [kN]


Resultant compression force: 141.53 [kN]
Resultant shear force: 15.86 [kN]

Calculation of Utilizations according to: ETAG 001, Annex C - Method A


(β- is the ratio between design load and design resistance)

Calculation of Utilisations - Tension loads

Tension - Steel Failure

NRk,s γM,s NRd,s NSd βN,s


Anchor
[kN] [-] [kN] [kN] [%]

104.40 1.47 71.02 1 0.00 0.0%

2 0.00 0.0%

3 13.27 18.7%

4 13.27 18.7%

Tecfi Anchor Design Software


20/08/2019 Page: 4 / 8
v. 3.0.3.817 - Database 85.6.2255171556
Project

Reference code
Design office
Person in charge
Construction Office
Person in charge

Tension - Pull Out Failure

NRk,p γM,p ψc NRd,p NSd βn,p


Anchor
[kN] [-] [-] [kN] [kN] [%]
50.00 1.8 1.00 27.78
1 0.00 0.0%

2 0.00 0.0%

3 13.27 47.8%

4 13.27 47.8%

Tension - Concrete Cone Failure


NRk,c=N0Rk,c · ψA,N · ψs,N · ψre,N · ψec,N

hef scr,N ccr,N fck,cube γMc


[mm] [mm] [mm] [N/mm²] [-]
103 309 155 25 1.8

The anchors are divided into 1 group

Verification performed with three or more edges cmax < ccr

Group N0Rk,c Ac,N A0c,N hef scr,N ccr,N c-x c+x c-y c+y
Anchor
No. [kN] [mm²] [mm²] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

1 [3, 4] 52.79 178,911 95,481 103 309 154 6,000 6,000 6,000 6,270

Group ψs,N ψre,N eN,x eN,y ψec,N NRk,c NRd,c Nsd βN,c
Anchor
No. [-] [-] [mm] [mm] [-] [kN] [kN] [kN] [%]

1 [3, 4] 1.000 1.000 0.0 0.0 1.000 98.92 54.95 26.53 48.3%

Tension - Splitting Failure

As smallest edge distance exceeds 1,2 x Ccr,sp and the thickness of concrete exceeds 2 x hef, it is assumed, acc. to Annex C
and TR029 5.2.2.6 a, that splitting failure will not occur.

Tecfi Anchor Design Software


20/08/2019 Page: 5 / 8
v. 3.0.3.817 - Database 85.6.2255171556
Project

Reference code
Design office
Person in charge
Construction Office
Person in charge

Calculation of Utilisations - Shear loads


Shear - Steel Failure Without Lever Arm

VRk,s γMs VRd,s


[kN] [-] [kN]

56.30 1.25 45.04

1 2 3 4

Vsd [kN] 3.96 3.96 3.96 3.96

βV,s [ % ] 8.8% 8.8% 8.8% 8.8%

Shear - Steel Failure With Lever Arm

No lever arm has been applied

Shear - Pryout Failure(NRk,c)


NRk,c=N0Rk,c · ψA,N · ψs,N · ψre,N · ψec,V,cp

VRk,cp=k · NRk,c

hef scr,N ccr,N fck,cube k γMc


[mm] [mm] [mm] [N/mm²] [-] [-]
103 309 155 25 2.0 1.5

The anchors are divided into 1 group

Group N0Rk,c Ac,N A0c,N ψs,N ψre,N c-x c+x c-y c+y
Anchor
No. [kN] [mm2] [mm2] [-] [-] [mm] [mm] [mm] [mm]

1 [1, 2, 3, 4] 52.79 335,241 95,481 1.000 1.000 6,000 6,000 6,000 6,000

Tecfi Anchor Design Software


20/08/2019 Page: 6 / 8
v. 3.0.3.817 - Database 85.6.2255171556
Project

Reference code
Design office
Person in charge
Construction Office
Person in charge

Group eN,x eN,y ψec,N NRk,c VRk,cp VRd,cp VSd βV,cp


Anchor
No. [mm] [mm] [-] [kN] [kN] [kN] [kN] [%]

1 [1, 2, 3, 4] 0.0 0.0 1.000 185.35 370.70 247.13 15.86 6.4%

Shear - Concrete Edge Failure

As all edges are greater than 10 hef and 60 d, the proof for concrete edge failure is omitted.

Combined tension and shear

Anchor Tension (βN) Shear (βV) Condition Utilisation Status

Steel 3 18.7% 8.8% β = β2N + β2V 4.3%

Concrete 3 48.3% 6.4% β = (β1.5N + β1.5V) 35.2%


Anchor

βN,s βN,p βN,comb βN,c βN,sp βV,s βV,sla βV,cp βV,c βN,s,max βV,s.max βN,c,max, βV,c,max,E βcombi,c,E βcombi,S,E
E

1 0.0% 0.0% 0.0% 0.0% 0.0% 8.8% 0.0% 6.4% 0.0% 0.0% 8.8% 0.0% 6.4% 1.6% 0.8%

2 0.0% 0.0% 0.0% 0.0% 0.0% 8.8% 0.0% 6.4% 0.0% 0.0% 8.8% 0.0% 6.4% 1.6% 0.8%

3 18.7% 47.8% 0.0% 48.3% 0.0% 8.8% 0.0% 6.4% 0.0% 18.7% 8.8% 48.3% 6.4% 35.2% 4.3%

4 18.7% 47.8% 0.0% 48.3% 0.0% 8.8% 0.0% 6.4% 0.0% 18.7% 8.8% 48.3% 6.4% 35.2% 4.3%

βN,s,max = βN,s
βV,s,max = max ( βV,s , βV,sla )

Tecfi Anchor Design Software


20/08/2019 Page: 7 / 8
v. 3.0.3.817 - Database 85.6.2255171556
Project

Reference code
Design office
Person in charge
Construction Office
Person in charge

βN,c,max,E = max ( βN,p , βN,c , βN,sp , βN,comb )


βV,c,max,E = max ( βV,cp , βV,c )
βcombi,s,E = β2N,s + β2V,s
βcombi,c,E = min[ ( β1.5N,c,max,E + β1.5V,c,max,E), ( βN,c,max,E + βV,c,max,E ) / 1.2 ]

With consideration of related anchors and separation of steel and concrete failure

RESULT
Ok. The product meets the design criteria

REMARKS
The verification of anchor design cases covered by ETAG 001 or TR29 is performed according to the selected Guideline. The
verification of anchor design cases non-covered by guidelines is based on the selected Guideline. Further information can be
found inside ACP Design Guides. The loads acting on anchors are evaluated according to the theory of elasticity, assuming
that the anchor plate does not deform under the design actions. To ensure the validity of this assumption the anchor plate
shall be sufficient stiff. The user must verify this condition, since the base plate stiffness is not automatically calculated by the
software. The transfer of loads from anchors into base material must be verified in accordance with ETAG 001 Annex C or
TR29 Section 7. The design method is valid only for clearance hole in the fixture with a diameter not larger than the values
given in ETAG 001 Annex C or TR29 Table 4.1.

IMPORTANT NOTICE
The data input to this software, and the relative results, must be checked by the user under the responsibility of an engineer
experienced in anchorages and concrete work. This is to ensure there are no errors and all data is complete and accurate and
complies with all rules and regulations for the actual conditions and application.
The data contained in this software relates only to the product illustrated therein and is based on principles, formulas and
safety regulations according to the existing guidelines for anchorages into concrete, together with the knowledge of the
manufacturer.
The user must comply with these principles. The user is solely responsible for the data entered into the program and any
errors or omissions are the responsibility of the user. The user must ensure that the most current version of the program is
installed by way of the auto-updating function offered by the manufacturer.
The user must update the program when instructed to do so.
The aim of the program is to act as a calculation aid and to assist in complying with current regulations and guidelines,
without any guarantee of suitability for any specific application.

Tecfi Anchor Design Software


20/08/2019 Page: 8 / 8
v. 3.0.3.817 - Database 85.6.2255171556

Potrebbero piacerti anche