FPSO KIKEH
SCOPE OF WORK
Date Approved by
Status/Revision No of pages Written by Reviewed by
(dd-MM-YYYY) Manager
35 MF VR VR
1 26-12-2017 (including
cover & Snr. Marine Marine
Marine Manager
attachment) Engineer Manager
FPSO KIKEH
MGO TRANSFER LINE ON MAIN DECK REPLACEMENT
TABLE OF CONTENTS
Abbreviations
DFT Dry Film Thickness
ITP Inspection & Test Plan
WPS Welding Procedure Specification
WQT Welder Qualification Test
MGO Marine Gas Oil
NDT Non Destructive Test
RT Radiography Test
MPI Magnetic Particle Inspection
Page 2 of 11
FPSO KIKEH
MGO TRANSFER LINE ON MAIN DECK REPLACEMENT
1.0 INTRODUCTION
FPSO Kikeh is owned and operated by SBM/MISC Joint Venture Malaysia Deepwater
Floating Terminal Ltd (MDFTL) under lease to Murphy Oil. The FPSO is permanently
moored by an external bow mounted turret at location 120km Northwest of Labuan
Island, Offshore Sabah, East Malaysia. The average water depth in the field is
approximately 1300m. Distance of FPSO Kikeh from Asean Supply Base is
approximately 130km.
1) CONTRACTOR to supply all piping materials, fittings as per MTO and valves as
per valve specification supplied in this scope of work.
4) CONTRACTOR to submit all certificate for material, valve, pressure gauge and
fittings to MDPC for review prior to fabrication.
6) CONTRACTOR to submit WPS and WQT for MDPC review during bidding and
prior to fabrication.
7) CONTRACTOR to fabricate piping spools and pipe support of MGO Transfer line
as per drawings attached in the Appendix section.
Note: CONTRACTOR is responsible to ensure all new piping spool are fit to
install on site. Hence, CONTRACTOR to perform site verification/dimensional
check of the supplied drawings prior to fabrication. Any additional cost
Page 3 of 11
FPSO KIKEH
MGO TRANSFER LINE ON MAIN DECK REPLACEMENT
incurred due to modification after the site verification is completed, that cost
shall be borne by CONTRACTOR.
8) CONTRACTOR to perform 10% RT and 100% MPI on all new weld joint.
10) CONTRACTOR shall inform MDPC representative prior to perform hydrotest and
invite for witness during the test.
11) All pre-fab spool shall be fully painted prior to delivery to offshore. All surface
preparation and painting/coating works shall follow standard marine practice.
Painting spec shall be as follows:
12) CONTRACTOR to demolish corroded piping section onboard in way of new piping
spools and other areas as deemed necessary by MDPC Project.
13) CONTRACTOR to erect and dismantle scaffold for spool installation. Scaffold
material shall be supplied by MDPC.
14) CONTRACTOR to install new pre-fab spool and all associated valve.
15) CONTRACTOR to erect pressurised habitat for new field weld joint during
installation.
17) CONTRACTOR to perform touch-up painting works on new weld joint performed
onboard.
18) CONTRACTOR to perform any other related works not specified in this document
but deemed necessary at site in order to complete the project.
Page 4 of 11
FPSO KIKEH
MGO TRANSFER LINE ON MAIN DECK REPLACEMENT
4.0 MANPOWER
CONTRACTOR shall provide manpower comprise of the following personnel and shall
meet minimum number required to safely perform the proposed job.
CONTRACTOR manpower should be as below but not limited to:
i.Project Engineer.
ii.Construction Supervisor.
iii.Pipe Fitter.
iv. Welder – qualified to 6G SMAW process.
v. Riggers cum helper.
vi. Fire Watcher.
vii. Habitat Technician.
viii.NDT Technician.
ix. Radiography Technician.
x. Scaffolding Supervisor- Min. Level II certificate from an accredited training
provider approved by DOSH
xi. Scaffolder – Level 1 certificate from an accredited training provider approved by
DOSH.
Note:
i) All manpower shall have valid Offshore Medical & BOSIET certificate.
ii) The CONTRACTOR is responsible to supply adequate manpower in order
to complete the project & meet the requirements of the project up to
satisfaction of MDPC rep. Any additional cost incurred shall be borne by
CONTRACTOR.
Page 5 of 11
FPSO KIKEH
MGO TRANSFER LINE ON MAIN DECK REPLACEMENT
Quantity : 3
Bonnet : Bolted
Wedge : Flexible
Seat : Replaceable
Stem : Trim 1
Wedge : Trim 7
Backseat : Trim 7
Bolting : A193-B7
A194-2H
Page 6 of 11
FPSO KIKEH
MGO TRANSFER LINE ON MAIN DECK REPLACEMENT
Size: 2 inch
Quantity : 3
Bonnet : Bolted
Wedge : Flexible
Seat : Replaceable
Stem : Trim 1
Wedge : Trim 7
Backseat : Trim 7
Bolting : A193-B7
A194-2H
Quantity : 2
Bonnet : Bolted
Wedge : Flexible
Page 7 of 11
FPSO KIKEH
MGO TRANSFER LINE ON MAIN DECK REPLACEMENT
Seat : Replaceable
Stem : Trim 1
Wedge : Trim 7
Backseat : Trim 7
Bolting : A193-B7
A194-2H
Size: 1 inch
Quantity : 2
Bore : Reduced
O-rings : Viton-B
Page 8 of 11
FPSO KIKEH
MGO TRANSFER LINE ON MAIN DECK REPLACEMENT
Bolting : A193-B7
A194-2H
Quantity : 4
Bore : Reduced
O-rings : Viton-B
Bolting : A193-B7
A194-2H
Quantity : 2
Page 9 of 11
FPSO KIKEH
MGO TRANSFER LINE ON MAIN DECK REPLACEMENT
Bonnet : Bolted
Piston : A182-F6a
Bolting : A193-B7
A194-2H
7.0 DOCUMENTATION
In Summary, the CONTRACTOR shall provide the following documentation to MDPC
but not limited to:
i. Project Work Pack.
ii. Project Schedule Plan.
iii. WPS, PQR & WQT.
iv. Manpower certificates.
v. Material Mill Certificate.
vi. Rigging Gear Certificate.
vii. Daily Progress Report.
viii. Dimensional Check Report.
ix. NDT report.
x. Hydrotest report.
xi. Painting Inspection Report.
xii. Leak test report.
xiii. As-built drawing.
Upon project completion, CONTRACTOR shall submit final dossier in one (1) original
set and two (2) copies. Each set shall consist of one (1) hardcopy and one (1) DVD.
Page 10 of 11
FPSO KIKEH
MGO TRANSFER LINE ON MAIN DECK REPLACEMENT
v. CONTRACTOR personnel will strictly adhere and comply with safety policy
implemented onboard FPSO Kikeh.
vi. CONTRACTOR personnel daily work on FPSO Kikeh shall be strictly controlled
and managed by the Permit to Work System (PTW).
10.0 APPENDIX
Page 11 of 11
1 TAG No. F16-PG -403
2 SERVICE Fill station at supply boat landing area (SB)
3 P.&.I.D. No. DKF16020
4 PROJECT PART Tanker refurbishment/ Conv.
GENERAL 5 MODULE No.
6 LINE No. 6"-FL-F16410-01C02
7 HAZARD AREA CLASSIFICATION CLASS I ZONE 1 GROUP IIB T3
8 MANUFACTURER SUPPLIER Bourdon Haenni Bourdon Haenni
9 MODEL No. MEX5
10 SERIAL No. *
11 FLUID MGO
12 FLUID STATE Liquid
13 UNIT MINIMUM NORMAL MAXIMUM
14 DESIGN PRESSURE barg 9.5
15 DESIGN TEMPERATURE ºC 60
16 INLET PRESSURE barg 8.5
17 INLET TEMPERATURE ºC 30
SERVICE 18 VISCOSITY mPa·s
CONDITIONS 19 CORROSION
20
21
22
23
24
25
26
27
28 LINE SIZE in 6
29 LINE RATING 150#
PROCESS 30 PIPE MATERIAL CARBON STEEL
CONNECTION 31
32
33
34
35
36 TYPE BOURDON TUBE 61 TYPE N.A.
37 MOUNTING DIRECT 62 MODEL No. N.A.
38 STEM LOCATION BOTTOM 63 PROCESS CONN. SIZE N.A.
39 CONNECTION SIZE ½" NPT-M 64 RATING FACING N.A. N.A.
40 CONNECTION TYPE SCREWED DIAPHRAGM 65 DIAPH MATERIAL N.A.
41 DIAL DIAMETER 100 mm SEAL 66 HOUSING MATERIAL N.A.
GAUGE 42 DIAL COLOUR WHITE 67 FLUSHING CONNECTION N.A.
DESIGN 43 MARKINGS COLOUR BLACK 68
44 POINTER COLOUR BLACK 69
45 RANGE UNIT 0 - 10 Barg 70
46 ACCURACY 1 % FULL SCALE 71 TYPE N.A.
47 BLOW-OUT PROTECTION REAR BLOWOUT DISC 72 MODEL No. N.A.
48 RING STYLE BAYONET TYPE 73 CAPILLARY MATERIAL N.A.
49 SOLID FRONT CONSTR. CAPILLARY 74 CAPILLARY LENGTH N.A.
NO
50 SIPHON COIL NO 75 CONNECTION TO SEAL N.A.
51 ELEMENT AISI 316L SS 76 CONNECTION TO GAUGE N.A.
52 SOCKET AISI 316L SS 77 FILL LIQUID N.A.
53 MOVEMENT AISI 316L SS 78 RED LINE ON DIAL NO
54 LENS SAFETY GLASS 79 CASE FILLING LIQUID GLYCERINE
GAUGE 55 CASE AISI 316L SS 80 PULSATION DAMPENING NO
MATERIAL 56 RING AISI 316L SS 81 OVERRANGE PROTECTION NO
57 82 MOUNTING BRACKET N.A.
MISC.
58 83 MATERIAL CERTIFICATE EN 10204 - 3.1
59 84 PRESSURE TEST YES
60 85 RESPONSE CALC. NO
(*) MANUFACTURER TO ADVISE