Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
1 / 32 Classification: 440.10.20.10
Reference: 200−P−991029−E−01/10.09
Contents
1 General information 3
2 D.C. Electric motors 3
3 Gear pumps 6
4 Starter relays 6
5 Electro−Motor−Pumps for group 05 pumps 8
6 D.C. Electric motors for group 05 pumps 9
7 Drive and connecting flange for group 05 pumps 15
8 Group 05 gear pumps 16
9 Electro−Motor−Pumps for group 1 pumps 18
10 D.C. Electric motors for group 1 pumps 19
11 Drives and connecting flange for group 1 pumps 27
12 Group 1 gear pumps 28
13 Components 30
14 Order designation examples of Electro−Motor−Pumps 30
2 / 32 200−P−991029−E−01/10.09
ET
1 General information
Electro−motor−pump is the simplest and more compact unit Directives and standards
able to supply hydraulic power, as flow and pressure, to oil− Atex:
dynamic actuators. The equipment and protective systems of these catalogue
The Electro−motor−pumps are largely used on industrial ARE NOT intended for use in potentially explosive atmos-
operating machines particularly on mobile machines, pheres that is to say where there is an explosive atmosphere
where, through simple valves and hoses connections it referred to in Article 2 of the Directive 99/92/EC and referred
makes possible to operate and control different to Article 1.3 of the Directive 94/9/EC.
hydraulics actuators. ISO 9001: 2000
In the present technical catalogue the most common ver- Bucher Hydraulics S.p.A. is certified for research, develop-
sions, obtained as combination of DC motors and External ment and production of directional control valves, power
Gear Pumps, either 05 (AP05) and 1 (AP100) group, are units, gear pumps and motors, electro pumps, cartridge
shown, although, many and different customised versions valves and integrated operating blocks for hydraulic
have been designed and realised in order to satisfy to spe- applications.
cific and dedicated customer’ requests.
− + − + −
+
M
M M
200−P−991029−E−01/10.09 3 / 32
ET
Continuous duty S1 Short time duty S2 Intermittent duty S3
td td
P P P
tm
t t tp t
C C Tmax C
Tmax Tmax
Tl
Teq
Ta Ta Ta
td t
t t S3 = x 100
td + tm
P = load Ta = ambient temperature
Teq = temperature at thermal equilibrium td = duration of on−load period
Tmax = maximum permissible temperature tm = duration of off−load period
Tl = operating temperature tp = duration of cycle (10 min.)
IP 4 4
second digit
Denotes protection factor
first digit
The second digit indicates the degree of protection The degree of protection indicated for each individual
afforded to the motor against the effects of penetration by electric motor refers to the motor when mounted to a
water. Bucher Hydraulics S.p.A. electro−motor−pump.
0 no protection
1 protection against water dripping vertically
2 protection against water dripping at 15 max
3 protection against rain
4 protected against water splash
5 protected against water spray
4 / 32 200−P−991029−E−01/10.09
ET
2.2 Characteristic curves
Characteristic curves are given for each motors, from consumption values, and S2 and S3 duty cycles.
which to establish pressure, flow rate and current
I (A)
20 160
(l/min.)
15 120
S2 S3
90
Q
10 80
5 40
S2
0 50 100 150 200 0 2.5 5 7.5 10 12.5 15 (min)
P (bar) S3
0 4 8 12 16 20 24 (%)
11.5
2.3 Example of how the graphs are used 2.4 Mounting directions
Required data The tie bolts must not be withdrawn completely when fit-
ting motors, but retracted a short distance (30−50 mm
Flow rate Q = 8 l/1’ max).
Pressure p =100 bar Once fitted to the electro−motor−pump, the motor should
be run off−load momentarily (5 seconds max) to verify its
Pump displacement correct operation: supply power to the windings and mea-
sure the current drain, which must not exceed the follow-
Determined by the intersection of the required p and Q
ing values:
curves.
24 V motor − I < 35 Ampere
In the example indicated, pump AP100/2.5 has the
12 V motor − I< 70 Ampere
required p and Q specifications.
In the event that there is no point of intersection with any Power cable
curve, a displacement as near as possible to the required
flow rate should be selected. The wire selected for power connections must be of cross
section appropriate for the rated current of the motor.
Current consumption
Tightening torques
This is determined by taking a vertical line from the pres- When assembling the motor and power pack and secur-
sure value to its point of intersection with the I curve cor- ing the wires of the power cable to the motor terminals,
responding to the selected displacement. observe the tightening torque values indicated.
In the example illustrated, current consumption is:
I = 90 Ampere Brush life
Type of use The brushes will wear down progressively with continued
operation of the motor, and must be replaced when
Having established the current, the relationship of the S2 reduced to their minimum useful length.
and S3 curves will give the following values: Since the rate of wear on the brushes is dictated by the
S2 = 6 min. S3 = 11.5% operating conditions and cannot therefore be broadly
specified, consult our Sales Department for guidance.
200−P−991029−E−01/10.09 5 / 32
ET
3 Gear pumps
3.1 Suitable fluids
Only mineral oil based hydraulic fluids responding to ISO/ * Caution! – Use of pumps at temperatures above 80_C must always
DIN standard should be used. be agreed upon with our Technical Office, and in any case this can
Viscosity range: cause a significant worsening in the volumetric efficiency.
recommended 20 − 120 mm2/s (cSt) For use under conditions different from those indicated in this cata-
permissible up to 700 mm2/s (cSt) logue, please contact our Sales Department.
Operating temperature range: −15 +80 C
For other fluids consult our Sales Department.
3.2 Inlet
Absolute pressure at the pump inlet must be
V > 0.75 bar (11 PSI)
Accordingly, avoid:
M P V
− significant differences in height of pump and tank M1 M
− long pipeline runs
− sharp bends, restrictions, etc. causing turbulent
M
flow
P
In certain applications, inlet pressure may be higher than 1
bar (14.3 PSI), or at any rate higher than atmospheric.
For pumps with standard configuration, the pressure regis- M
tering at the gauge M1 should be:
M1 < 3.5 bar (50 PSI).
3.3 Outlet
Pressure levels: p (bar)
P1 = continuous operating pressure P3
P2 = intermittent operating pressure
P3 = peak pressure P2
The recommended delivery pipe oil speed is between: v P1
= 2 − 5 m/s
In the next pages are indicated the performances for
each pump. t (s)
max. 15 s
4 Starter relays
Technical information 1. Direct
Versions: The relay is secured with screws, using holes already
Available voltages: 12−24 V D.C. tapped in motor frame. In this instance there is one standard
Standard: suitable for most applications. mounting position only.
Heavy duty: for more arduous conditions 2. Metal clip
See relative table for technical data Suitable for standard relays only.
Contact life: The relay is secured by means of a clip encircling the motor
The contacts of the relay will wear down progressively dur- frame and inserted through special slots in the feet of the
ing operation. relay itself.
Since the rate of wear is dedicated by the type of duty and In this instance, several mounting positions are possible.
cannot therefore be broadly specified, consult our Sales Electrical diagram
dept. for guideline information. A typical arrangement for connection of the relay to the elec-
Fitment to electric motor tric motor is shown in the diagram.
Starter relays can be fitted to the frame of the motor by two
different methods:
4 Nm 10 Nm Ch.10
+
− +
−
+ − +
D1, E1 A2, E2
D1, E1
M
A2, E2
6 / 32 200−P−991029−E−01/10.09
ET
Motor starter relays
54.5 (2.14")
48 (1.89")
Code 200544134106 200544134209
Amps
Terminal connection Consumption 2.8 A 1.1 A
6.35x0.8 (.25x.03)
by the coil
Insulation class F
10 (.39")
30 (1.18")
82 (3.23")
20 (.79")
30 (1.18") 6 (.24")
Voltage 12 V 24 V
(1.73")
(2.2")
42 (1.65")
56
Amps
Consumption 2A 1.1 A
by the coil
+1
5 Nm Current for continuous duty 150 A
(1.93")
+1Nm
Max. current (5 sec.) 800 A
3
ø 49
Insulation class B
200−P−991029−E−01/10.09 7 / 32
ET
5 Electro−Motor−Pumps for group 05 pumps
ã ã ã
Without starting relay With starting relay
A2
A2
A1
A1
AP05/** S 819
AP05/** S 319
A1
A1
A2
A2
8 / 32 200−P−991029−E−01/10.09
ET
6 D.C. Electric motors for group 05 pumps
Ĩ A1
ø76
(0.59")
Ī
6.43 (0.25")
A2
M6x1
ø 14.9
+0
5 −2 Nm
10
A1
A1
Rotation
Right 12 V − 350 W 24 V − 400 W 12 V − 350 W 24 V − 400 W
C117PE/V0 C220PE/Z0
Type C117PE/V0 C220PE/Z0
+ R106 + R209
Ī A2 Ī Ī
A2 A2 Ī A2
200−P−991029−E−01/10.09 9 / 32
ET
12 V − 350 W
I (A)
6 120
5 100
4 80
(l/min.)
3 60
Q
S3
2 40 S2
1 20
Q
S2
0 50 100 150 200 2 4 6 8 10 12 (min)
P (bar) S3
24 V − 400 W 6 12 18 24 30 36 (%)
I (A)
9
90
7.5
75
6
60
(l/min.)
4.5
45
Q
3
30
S3
1.5
15
Q S2
S2
0 50 100 150 200 4 8 12 16 20 24 (min)
P (bar) S3
10 20 30 40 50 60 (%)
10 / 32 200−P−991029−E−01/10.09
ET
Protection index: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IP54
Voltage 12 V 24 V Insulation class: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F
Type of winding: . . . . . . . . . . . . . . . . . . . . . . . . . . Compound
Brushes kit: . . . . . . . . . . . . . . . . . . . . . . . . . . . 200544138026
Nominal Power 700 W 800 W Relay fixing kit . . . . . . . . . . . . . . . . . . . . . . . . 200544108005
Minimum brushes length: . . . . . . . . . . . . 5 mm (0.2 inches)
+0 10
5 −2 Nm
ø 14.9
6.43
ø 79.5
(.25”)
(.59”)
8 ±1 Nm
Rotation
Right 12 V − 700 W 24 V − 800 W 12 V − 700 W 24 V − 800 W
C128AE/S0 C232AE/R0
Type C128AE/S0 C232AE/R0
+ R106 + R209
S A F G
200−P−991029−E−01/10.09 11 / 32
ET
12 V − 700 W
I (A)
9 240
7.5 200
6 160
(l/min.)
4.5 120
Q
3 80
S2 S3
1.5 40
Q
S2
0 50 100 150 200 3 6 9 12 15 18 (min)
P (bar) S3
6 12 18 24 30 36 (%)
24 V − 800 W
I (A)
9 120
7.5 100
6 80
(l/min.)
4.5 60
Q
3 40
S3
1.5 20
S2
S2
0 50 100 150 200 3 6 9 12 15 18 (min)
P (bar) S3
6 12 18 24 30 36 (%)
12 / 32 200−P−991029−E−01/10.09
ET
Protection index: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IP54
Voltage 12 V 24 V Insulation class: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F
Type of winding: . . . . . . . . . . . . . . . . . . Permanent magnets
Brushes kit: . . . . . . . . . . . . . . . . . . . . . . . . . . . 200544138026
Nominal Power 700 W 800W Relay fixing kit . . . . . . . . . . . . . . . . . . . . . . . . 200544108005
Minimum brushes length: . . . . . . . . . . . . 5 mm (0.2 inches)
+0 10
5 −2 Nm
ø 14.9
6.43
ø 79.5
Ī A2
(.25”)
(.59”)
A1
A2
A2
Rotation
Right 12 V − 700 W 24 V − 800 W 12 V − 700 W 24 V −800 W
C128PE/X0 C229PE/Y0
Type C128PE/X0 C229PE/Y0
+ R106 + R209
Ĩ A1 Ī A2 Ĩ A1 Ī A2
200−P−991029−E−01/10.09 13 / 32
ET
12 V − 700 W
I (A)
9 240
7.5 200
6 160
(l/min.)
S3
4.5 120
Q
3 80
S2
1.5 40
Q
S2
0 50 100 150 200 2 4 6 8 10 12 (min)
P (bar) S3
5 10 15 20 25 30 (%)
24 V − 800 W
I (A)
9 120
7.5 100
6 80
(l/min.)
4.5 60
Q
3 40
S3
1.5 20
S2
S2
0 50 100 150 200 3 6 9 12 15 18 (min)
P (bar) S3
6 12 18 24 30 36 (%)
14 / 32 200−P−991029−E−01/10.09
ET
7 Drive and connecting flange for group 05 pumps
E56
E56 code: 200760400320
Adaptor code: 200658100030 Connecting flange code: 200658100010 Coupling code: 200659600260
6.4 (.25")
98.3 (3.87")
106.6 (4.20")
63.5 (2.5")
98.3 (3.87")
18 (.71")
6.4 (.25")
4.6 (.18")
5.5 (.22")
25.5 (1")
37 (1.46")
90 (3.54")
Ø 22.H7
113.5 (4.47")
66 (2.60")
25.6 (1.01")
M
57.5 (2.26")
M10X1.5 (.39")
82 (3.23")
Ø 112 (4.41")
200−P−991029−E−01/10.09 15 / 32
ET
8 Group 05 gear pumps
.197"−.196"
.866"−.864" DIA
ø22 f8
5 f7
1.004"
25.5
.295"
7.5
2.047"
3.15"
2.6"
52
80
66
Dimensions
Displacement Order code
Type A B
cm3/rev Counterclockwise rotation: S
mm inches mm inches
16 / 32 200−P−991029−E−01/10.09
ET
Group AP05 Code 319
4 24
.866"−.864" DIA
.158" .945"
Suction−Pressure
20+5 Nm
.197"−.196"
ø22 f8
5 f7
1/4" BSPP
1.004"
.295"
25.5
7.5
19
2.047"
3.15"
2.6"
80
66
52
Dimensions
Displacement Order code
Type A
cm3/rev Counterclockwise rotation: S
mm inches
200−P−991029−E−01/10.09 17 / 32
ET
9 Electro−Motor−Pumps for group 1 pumps
ã ã ã
Without starting relay With starting relay
E45
48V−2000W T82K
18 / 32 200−P−991029−E−01/10.09
ET
10 D.C. Electric motors for group 1 pumps
8.5+0.5 Nm
112 (4.41")
+0.5
5.42 0 (.21")
(.25")
ø
35 j6
90
ø
6.43 +0.1
0
(3.54")
(1.38")
7.85 +0.9
0
(.41")
8±1 Nm
7.9 +1.4
0 (.31")
Weight: 6.800 Kg (14.960 lb)
Rotation
Right 12 V − 1600 W 24 V − 2200 W 12 V − 1600 W 24 V − 2200 W 12 V − 1600 W 24 V − 2200 W
C135AK/X0 C240AK/Y0
Type C135AK/X0 C240AK/Y0 C135AK/X1 C240AK/Y1
+R107 +R210
Code 200543913501 200543924001 200543913503 200543924002 200763310090 200763320090
Relay Standard Heavy duty
R107 R210
Relay type R106 R209
Standard positions only
200−P−991029−E−01/10.09 19 / 32
ET
12 V − 1600 W
I (A)
30 420
25 350
20 280
S2
(l/min.)
15 210
S3
Q
10 140
5 70
S2
0 50 100 150 200 3 6 9 12 15 18 (min)
P (bar) S3
7 14 21 28 35 42 (%)
24 V − 2200 W
I (A)
30 180
S2
25 150
20 120
S3
(l/min.)
15 90
Q
10 60
5 30
S2
0 50 100 150 200 2 4 6 8 10 12 (min)
P (bar) S3
4 8 12 16 20 24 (%)
20 / 32 200−P−991029−E−01/10.09
ET
Protection index: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IP54
Voltage 12 V 24 V Insulation class: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F
Type of winding: . . . . . . . . . . . . . . . . . . . . . . . . . . Compound
Nominal Power 1500 W 2000 W Brushes kit: . . . . . . . . . . . . . . . . . . (12/1500) 200544138016
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . (24/2000) 200544138015
Minimum brushes length: . . . . . . . . . 12.5 mm (0.5 inches)
45
188.5 (7.42") 13
8.5#+0.5 Nm
112 (4.41")
ø 18−0.1
0
(1.65")
8 e10
(.31") 8 +0.5
0
ø
ø 42 −0.01
−0.05
90 (3.54")
8±1 Nm 10
(.71")
Weight : 7.3 Kg (15.4 lb) (.31")
Rotation
Right 12 V − 1500 W 24 V − 2000 W 12 V − 1500 W 24 V − 2000 W 12 V − 1500 W 24 V − 2000 W
C134AK/O0 C238AK/P0 C134AK/O0 C238AK/P0
Type C134AK/O0 C238AK/P0
+R106 +R209 +R107 +R210
Code 200543913416 200543923813 200763310010 200763320030 200763310030 200763320050
Relay Standard Heavy duty
R107 R210
Relay type R106 R209
Standard positions only
200−P−991029−E−01/10.09 21 / 32
ET
12 V − 1500 W
I (A)
30 240
25 200 S2 S3
20 160
(l/min.)
15 120
Q
10 80
5 40
S2
0 50 100 150 200 2 4 6 8 10 12 (min)
P (bar) S3
4 8 12 16 20 24 (%)
24 V − 2000 W
I (A)
30 240
25 200
20 160
(l/min.)
15 120
S2 S3
Q
10 80
5 40
S2
0 50 100 150 200 2.5 5 7.5 10 12.5 15 (min)
P (bar) S3
4 8 12 16 20 24 (%)
22 / 32 200−P−991029−E−01/10.09
ET
Protection index: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IP44
Voltage 12 V 24 V Insulation class: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B
Type of winding: . . . . . . . . . . . . . . . . . . . . . . . . . . Compound
Nominal Power 1700 W 2200 W Brushes kit: . . . . . . . . . (12/2000−24/2500) 200544138012
Minimum Brushes length: . . . . . . . . . . . 5 mm (0.2 inches)
34
175.7 (6.92") −0
5 +2 Nm
(4.61")
(.25")
0
(.23") 5.8 −0.3
6.43 +0.1
ø117
ø35 (1.38")
90 (3.54")
+0.55
8.7
−0.65 (.34") 8±1 Nm
Weight : 8 Kg (17.5 lb)
Rotation
Right 12 V − 1700 W 24 V − 2200 W 12 V − 1700 W 24 V − 2200 W 12 V − 1700 W 24 V − 2200 W
200−P−991029−E−01/10.09 23 / 32
ET
12 V − 1700 W
I (A)
30 280
S2 S3
25 240
20 200
(l/min.)
15 160
Q
10 120
5 80
S2
0 50 100 150 200 3 6 9 12 15 18 (min)
P (bar) S3
5 10 15 20 25 30 (%)
24 V − 2200 W
I (A)
30 180
S3
S2
25 150
20 120
(l/min.)
15 90
Q
10 60
5 30
S2
0 50 100 150 200 2 4 6 8 10 12 (min)
P (bar) S3
4 8 12 16 20 24 (%)
24 / 32 200−P−991029−E−01/10.09
ET
Protection index: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IP54
Voltage 48V Insulation class: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F
Type of winding: . . . . . . . . . . . . . . . . . . . . . . . . . . Compound
Nominal Power 2000 W Brushes kit: . . . . . . . . . . . . . . . . . . . . . . . . . . . 200544138018
Minimum brushes lenght: . . . . . . . . . 12.5 mm (0.5 inches)
188.5 (7.42")
8.5+0.5 Nm
Ø112(4.41")
Ø18 −0.1
8 e 10
(1.65")
0
(.31") 8 +0.5
0
90 (3.54")
Ø42 −0.01
−0.05
8±1 Nm
(.71")
(.31")
Motor
Rotation
Right
48 V − 2000 W
Type T82K
Code 200543933803
Relay
Relay type
Standard positions
S A
200−P−991029−E−01/10.09 25 / 32
ET
48 V − 2000 W
I (A)
30 150
25 125
20 100
(l/min.)
15 75
Q
10 50
S3
Q S2
5 25
Q
S2
0 50 100 150 200 5 10 15 20 25 30 (min)
P (bar) S3
10 20 30 40 50 60 (%)
26 / 32 200−P−991029−E−01/10.09
ET
11 Drives and connecting flange for group 1 pumps
(1.38")
(1.65")
(1.1")
8 (.31")
5.5 (.22")
ø 28
ø 35
ø 42
14.5 (.57")
6 (.24")
98.3 (3.87")
M
57.5 (2.26")
10 (.39")
13 (.51")
The connecting flange code doesn’t include: 82 (3.23")
+ 4 screw code: 200521603013 (M006x025) 37 (1.46")
+ 4 washer code: 200530390611 ø 112 (4.41")
E56
The connecting flange code doesn’t include:
+ 4 screw code: 200521603013 (M006x025)
+ 4 washer code: 200530390611
8 (.31")
(.79")
113.5 (4.47")
98.3 (3.87")
71.9 (2.83")
ø 20
25.6 (1.01")
57.5 (2.26")
31 (1.22")
200−P−991029−E−01/10.09 27 / 32
ET
12 Group 1 gear pumps
Cu. In. P1 P2 P3
Type cm3/rev P ≤ P1 P > P1 P ≤ P1 P > P1
P. R. bar P.S.I. bar P.S.I. bar P.S.I.
AP100/1.2 1.2 .073 210 3000 250 3600 280 4000 800 1000 4500 5000
AP100/1.7 1.7 .103 210 3000 250 3600 280 4000 650 800 4500 5000
AP100/2.5 2.5 .152 210 3000 250 3600 280 4000 650 800 4500 5000
AP100/3.5 3.5 .213 210 3000 230 3300 250 3600 650 800 3500 4000
AP100/4.3 4.3 .262 210 3000 230 3300 250 3600 550 700 3500 4000
AP100/5 5.0 .305 210 3000 230 3300 250 3600 500 650 3000 3500
AP100/6.5 6.5 .396 190 2700 220 3150 240 3400 500 650 2500 3000
AP100/8 7.8 .476 180 2600 210 3000 230 3300 500 650 2500 3000
AP100/10 10.0 .610 150 2150 180 2600 200 2900 500 650 2000 2500
A 4
68 .157"
2.677" B
.999"−.998"DIA
−0.020
ø 25.4 −0.053
52.4 16 65
.313"−.312"
2.063"
−0.040
8 −0.076
.630" 2.560"
.866"DIA
.472"DIA
ø 12
ø 22
1.279"
1.031"
32.5
26.2
.433"
11
2.874"
2.830"
3.425"
71.9
87
73
7.1 12 4.5 ± 0.15
.28" M6 Depth 13 − .50" .472" .183"−.171"
30 6.5
Suction−Pressure 1.181" .256"
Dimensions
Displacement Order code
Type A B
cm3/rev Counterclockwise rotation: S
mm inches mm inches
AP100/1.2 1.2 82.5 3.25 38.5 1.51 200101114306
AP100/1.7 1.7 84.5 3.33 39.5 1.55 200101214307
AP100/2.5 2.5 88 3.46 41 1.61 200101314306 S
AP100/3.5 3.5 92 3.62 43.5 1.71 200101414306
AP100/4.3 4.3 96 3.78 45 1.77 200101514306
AP100/5 5 98.5 3.88 46.5 1.83 200101614304
AP100/6.5 6.5 103.5 4.07 49 1.93 200101714304
AP100/8 7.8 109 4.29 52 2.05 200101814302
AP100/10 10 118 4.64 56.5 2.22
28 / 32 200−P−991029−E−01/10.09
ET
Group AP100 Code 319
A 4
52.4 67
.157"
2.063" 2.560"
.999"−.998" DIA
−0.020
ø 25.4 −0.053
30
16
.313"−.312"
1.031"
1.181"
26.2
.472" DIA
−0.040
8 −0.076
.866" DIA
.630"
ø 12
ø 22
1.279"
32.5
.433"
2.830"
2.874"
3.425"
11
71.9
73
87
Suction−Pressure
3/8" BSPP
50+5 Nm
4.5
7.1
.183"−.171"
22
.28"
68 6.5
2.677" .256"
Dimensions
Displacement Order code
Type A
cm3/rev Counterclockwise rotation: S
mm inches
AP100/1.2 1.2 82.5 3.25 200101114307
AP100/1.7 1.7 84.5 3.33 200101214308
AP100/2.5 2.5 88 3.46 200101314307 S
AP100/3.5 3.5 92 3.62 200101414307
AP100/4.3 4.3 96 3.78 200101514308
AP100/5 5 98.5 3.88 200101614305
AP100/6.5 6.5 103.5 4.07 200101714305
AP100/8 7.8 109 4.29 200101814303
AP100/10 10 118 4.64
69.5 (2.74")
−8
40 +10 Nm
−2
12 +4 Nm
60 (2.36")
41 (1.61")
Spring Spring color Spring code Setting range Standard setting Type Relief valve code
02 200662401470 5 − 30 bar 20 bar 02VM01 200787400700
06 Yellow 200662401450 30 − 95 bar 60 bar 06VM01 200787400720
15 Green 200662401480 95 − 210 bar 150 bar 15VM01 200787400740
22 Blue 200662401460 200 − 300 bar 220 bar 22VM01 200787400710
200−P−991029−E−01/10.09 29 / 32
ET
13 Components
13.1 Pressed steel bracket 13.2 Protective cover for D.C. motors
Ø 11 n2 holes
(1.89")
147.5
48
(.43")
(5.8")
(4.3")
110
Ø 9 n4 holes
ø 149
(5.8")
(.35")
(5.51")
(3.23")
(4.88")
140
124
82
125 203
(4.9") (8")
124
(4.88")
140
Code* (5.51") Code* For : C134AK−C238AK−T82K
200777400120 200968800090 Motor type only
November 9K 0K 1K 2K Description
MADE IN ITALY
December 9L 0L 1L 2L
30 / 32 200−P−991029−E−01/10.09
ET
200−P−991029−E−01/10.09 31 / 32
ET
02/2001 Id.Nr. 200.599.991208
info.it@bucherhydraulics.com www.bucherhydraulics.com
E 2009 by Bucher Hydraulics S.p.A., IT − 42100 Reggio Emilia.
All rights reserved.
Data is provided for the purpose of product description only, and must not be considered as warranted characteristics in the legal
sense. The information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are
subject to continual improvement, we reserve the right to amend the product specifications contained in this catalogue.
Classification: 440.405.000
32 / 32 200−P−991029−E−01/10.09
ET