Sei sulla pagina 1di 10

Job No.

: Date: 25-Mar-11
Client: Designed By:
Building: Checked By:

WIND COLUMN BASE PLATE

DL+LL DL+WL
Shear Force (Fx) kN 25 25
Axial Force (Fy) kN 247 247
Web Size mm 450 x6
Flange Depth mm 220 x12
Bolts Dia mm 24
No. Of Bolts (n) 6
Plate Thickness (t) mm 20
Pitch (p) mm 100
guage (g) mm 100
Embed Length (Le) mm 835

PLATE LENGTH : 450 mm


PLATE WIDTH : 200 mm

CHECK FOR BOLT SIZE

FORCES IN THE BOLTS Actual Allowable


(kN) (kN)

Max Tension due to Axial Force ( Fy/n ) : 41.17 46.13

Shear in each Bolt ( Fx/n) : 4.18 30.75

CHECK FOR THICKNESS OF PLATE FOR TENSION

Maximum bending moment in the plate(Ma) : P x g/ 4


( About criticle section X-X) : 41.17x0.1/4
: 1.03 kN.m

Thickness of plate required ( t ) : 6 x Ma / f x p

: 16.47 <20mm

CHECK FOR COMBINED TENSION AND SHEAR

Actual Tension Actual Shear


+ <1.4
+ <1.4
Allowable Tension Allowable Shear

(41.17 / 46.13 + 4.18333333333333 1.03 <1.4

CHECK FOR BOLT LENGTH

Bond Stress For M20 grade Cocrete : 1.2 N/mm2

Length of bolt required : Tension in bolt/(p x bolt Dia.)x Bond stress


: 41.17x1000/(3.14x)x1.2
: 656 mm

CHECK FOR THICKNESS OF PLATE FOR COMPRESSION

Permissible bending stress in slab base, sbs ( Clause 5.4.3.2) : 185 N/mm2

Min area required for the base plate 223 mm2

Provided Base Plate Area: 90000 mm2

Thickness of base plate for columns other than circular

sections can be calculated as (Clause 5.4.3)


t2 = 3x w x(a2 - b2/4)
sbs
where,
w is the pressure or loading on the underside of the base in Mpa = 2.74 N/mm2

t is the Slab thickness in mm

a is the greater projection of the plate beyond column in mm = -12 mm

b is the lesser projection of the plate beyond column in mm = -10 mm

Half the depth of the Section provided (column) = 211 mm

Therefore, thickness of the base plate is = 2.30 mm


Nominal Tensile Stress, Fnt =
Nominal Shear Stress. Fnv=

Dia
16
20
24
32

Hence Safe

Hence Safe

Hence Safe
Hence Safe

Hence Safe

Hence Safe
Grade Gr 4.6
Nominal Tensile Stress, Fnt = 240 N/mm²
Nominal Shear Stress. Fnv= 160 N/mm²
Ω = 2.00
Ab= Nominal unthreaded body area of bolt

20502 13668

Tension Shear KIRBY VALUES, BASELESS


20.50 13.67 510 20.80 13.60
32.03 21.36 655 32.70 21.30
46.13 30.75 835 47.20 31.80
82.00 54.67 1200
65.00 56.50
l

WIND COLUMN BASE PLATE

DL+LL DL+WL
Shear Force (Fx) kN 38 38
Axial Force (Fy) kN 493 493
Web Size mm 450 x6
Flange Depth mm 220 x10
Bolts Dia mm 32
No. Of Bolts (n) 6
Plate Thickness (t) mm 24
Pitch (p) mm 130
guage (g) mm 130
Embed Length (Le) mm 1200

PLATE LENGTH : 550 mm


PLATE WIDTH : 250 mm

CHECK FOR BOLT SIZE

FORCES IN THE BOLTS Actual Allowable


(kN) (kN)

Max Tension due to Axial Force ( Fy/n ) : 82.17 82.00

Shear in each Bolt ( Fx/n) : 6.33 54.67

CHECK FOR THICKNESS OF PLATE FOR TENSION

Maximum bending moment in the plate(Ma) : P x g/ 4


( About criticle section X-X) : 82.17x0.13/4
: 2.68 kN.m

Thickness of plate required ( t ) : 6 x Ma / f x p

: 23.31 <24mm

CHECK FOR COMBINED TENSION AND SHEAR

Actual Tension Actual Shear


+ <1.4
+ <1.4
Allowable Tension Allowable Shear

(82.17 / 82 + 6.33333333333333 / 5 1.12 <1.4

CHECK FOR BOLT LENGTH

Bond Stress For M20 grade Cocrete : 1.2 N/mm2

Length of bolt required : Tension in bolt/(p x bolt Dia.)x Bond stress


: 82.17x1000/(3.14x)x1.2
: 981 mm

CHECK FOR THICKNESS OF PLATE FOR COMPRESSION

Permissible bending stress in slab base, sbs ( Clause 5.4.3.2) : 185 N/mm2

Min area required for the base plate 444 mm2

Provided Base Plate Area: 137500 mm2

Thickness of base plate for columns other than circular

sections can be calculated as (Clause 5.4.3)


t2 = 3x w x(a2 - b2/4)
sbs
where,
w is the pressure or loading on the underside of the base in Mpa = 3.59 N/mm2

t is the Slab thickness in mm

a is the greater projection of the plate beyond column in mm = 40 mm

b is the lesser projection of the plate beyond column in mm = 15 mm

Half the depth of the Section provided (column) = 201 mm

Therefore, thickness of the base plate is = 9.47 mm


Nominal Tensile Stress, Fnt =
Nominal Shear Stress. Fnv=

Dia
16
20
24
32
36

Rev

Hence Safe

Hence Safe
Hence Safe

Hence Safe

Hence Safe
Grade Gr 4.6
Nominal Tensile Stress, Fnt = 240 N/mm²
Nominal Shear Stress. Fnv= 160 N/mm²
Ω = 2.00
Ab= Nominal unthreaded body area of bolt

20502 13668

Tension Shear KIRBY VALUES, BASELESS


20.50 13.67 510 20.80 13.60
32.03 21.36 655 32.70 21.30
46.13 30.75 835 47.20 31.80
82.00 54.67 1200
103.78 69.19 1400 65.00 56.50

Potrebbero piacerti anche