SAUDI ARAMCO INSPECTION CHECKLIST
SAIC-RT-
Radiographic Film Evaluation and Reporting 14-May-18 NDE-
2009
PROJECT TITLE WBS / BI / JO NUMBER CONTRACTOR / SUBCONTRACTOR

EQUIPMENT ID NUMBER(S) EQUIPMENT DESCRIPTION EQPT CODE SYSTEM ID. PLANT NO.

LAYOUT DRAWING NUMBER REV. NO. PURCHASE ORDER NUMBER EC / PMCC / MCC NO.

SCHEDULED INSPECTION DATE & TIME ACTUAL INSPECTION DATE & TIME QUANTITY INSP. MH's SPENT TRAVEL TIME
SAUDI ARAMCO USE ONLY
SAUDI ARAMCO TIP NUMBER SAUDI ARAMCO ACTIVITY NUMBER WORK PERMIT REQUIRED?

SAUDI ARAMCO INSPECTION LEVEL CONTRACTOR INSPECTION LEVEL

ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.

A General Requirements ... Additional Requirements Shall be as agreed upon in SAIC-RT-2010. See Notes.

Radiographic procedure approved by Inspection department is


SAES-W-011
A1 available to verify Quality requirements for Radiographs and the
Para 17.1.1
acceptance criteria applied.
Personnel performing Radiographic Film Interpretation (RTFI)
are certified to level II and have met the requirements of SAEP- SAEP-1143
A2
1142. Para. 5.2.3
(Refer to SAIC-RT-2002 for personnel qualifications)

The viewing facility/darkroom is provided with subdued


SAEP-1143
A3 background lighting of an intensity that does not cause
Para. 6.5.1
troublesome reflections, shadows, or glare on the radiograph.

Radiographic viewer(s) with a luminance of 100,000 cd/m² or


more for viewing radiographic density up to 4.0 are provided
with a device for continuous control of screen luminance. (Refer
to ISO 5580, Para. 2.3)
Note: ISO 5580, Para. 2.3 specifies the minimum requirements
for Radiographic illuminators as shown in the the table below.

SAEP-1143
A4
Para. 6.5.2

Calibrated Densitometers are available to measure the density


of the exposed films. SAEP-1143
A5
Note:Densitometer shall be calibrated annually in accordance Para. 6.5.4
with ASTM SE-1079, as verified from the calibration certificate.

A density film strip traceable to a national standard is provided


SAEP-1143
A6 to verify the performance of Densitometer. Performance shall be
Para. 6.5.4
verified before each use .

Acceptance criterias (of the applicable Code) are provided or SAEP-1143


A7
posted near the Film Viewer. Appendix 1

Personnel interpreting radiographs shall allow 3 minutes in the


SAEP-1143
A8 darkened area for their eyes to adjust if coming from normal
Para. 10.2
room light and at least 5 minutes if coming in from full sunlight.

Saudi Aramco: Company General Use


Composite viewing of double film exposure is not permitted
SAEP-1143
A9 unless approved in writing by an Inspection Department
Para. 10.4
approved NDT RT Level III.

Saudi Aramco: Company General Use


SAUDI ARAMCO ID/PIEU - 14- May 2018 - REV. 2018.03.00 (Standards Cutoff -March 31, 2018) Rev. 2018.03.00 31-Mar-18
SAIC NUMBER DATE APPROVED QR NUMBER
SAUDI ARAMCO INSPECTION CHECKLIST
SAIC-RT-
Radiographic Film Evaluation and Reporting 14-May-18 NDE-
2009
Attachment 1 -- SAEP-1143 IQI Sensitivity (Penetrameter Wire Tables)

Saudi Aramco: Company General Use