Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Study on the convective heat transfer and pressure drop in the micro-channel heat sink ☆
Paisarn Naphon ⁎, Osod Khonseur
Thermo-Fluid and Heat Transfer Enhancement Laboratory (TFHT), Department of Mechanical Engineering, Faculty of Engineering, Srinakharinwirot University,
63 Rangsit-Nakhornnayok Rd., Ongkharak, Nakhorn-Nayok, 26120, Thailand
a r t i c l e i n f o a b s t r a c t
Available online 7 October 2008 Experiments have been performed to investigate the heat transfer characteristics and pressure drop in the
micro-channel heat sinks under constant heat flux conditions. The experiments are performed for the Reynolds
Keywords: number and heat flux in the ranges of 200–1000 and 1.80–5.40 kW/m2, respectively. The micro-channel heat
Convective heat transfer sink with two different channel heights and two different channel widths are accomplished by wire electrical
Micro-channel
discharge machine. Effects of different geometrical configurations parameters of the micro-channel and heat
Heat sink
flux on the heat transfer characteristics and pressure drop are considered. The micro-channel geometry
configuration has significant effect on the enhancement heat transfer and pressure drop. The results of this
study are expected to lead to guidelines that will allow the design of the micro-channel heat exchangers with
improved heat transfer performance of the electronic devices.
© 2008 Elsevier Ltd. All rights reserved.
0735-1933/$ – see front matter © 2008 Elsevier Ltd. All rights reserved.
doi:10.1016/j.icheatmasstransfer.2008.09.001
40 P. Naphon, O. Khonseur / International Communications in Heat and Mass Transfer 36 (2009) 39–44
Fig. 2. Schematic diagram of the test section and micro-channel heat sink.
the heater and the removal heat transfer by cooling air. The temperature at The average heat transfer coefficient is presented in terms of
each position and pressure drop across the test section were recorded average Nusselt number as follows:
three times. Data collection was carried out using a data acquisition system.
The uncertainty and accuracy of the measurement are given in Table 2. hm Dh
Nu ¼ ð6Þ
k
3. Data reduction
where k is the thermal conductivity of air, Dh is the hydraulic diameter
The data reduction of the measured data is summarized in the fol- of the channel before entering the test section.
lowing procedures: Reynolds number based on the hydraulic diameter, Dh, of the
Heat transferred to the cooling air in the test section, Qa, can be channel as follows:
calculated from
ud Dh
Re ¼ ð7Þ
Qa ¼ ma Cp;a Ta;ave;out −Ta;ave;in ð1Þ m
where ma is the air mass flow rate, Cp,a is the specific heat of air, Ta,ave,in and 4d Across
Dh ¼ ð8Þ
Ta,ave,out are the average inlet and outlet air temperatures, respectively. P
Heat added to the micro-channel heat sink can be calculated from where u is the air velocity, ν is the viscous of air, Across is the cross
measuring voltage and current supplied the test section as follows: section area of the channel before entering the test section, and P is
Qheater ¼ Vd I ð2Þ the wet perimeter of the channel.
The average heat transfer rate, Qave, used in the calculation is deter- 4. Results and discussion
mined from the heat removal my cooling air and the heat supplied to the
heat sink as follows: Fig. 3 shows the variation of the outlet air temperature with air
Reynolds number for different channel widths. Higher heat transfer
Qa þ Qheater
Qave ¼ ð3Þ rate as air mass flow rate increases. However, increase of heat transfer
2
rate is less than that of air mass flow rate. Therefore, outlet air
The average heat transfer coefficient of the micro-channel heat sink, temperature tends to decrease as air mass flow rate increases. Higher
hm, can be calculated from the average heat transfer rate obtained from surface area and surface roughness result in increase heat transfer
rate, therefore, the outlet air temperatures of channel with of
Qave ¼ hm Am ðΔTLMTD Þ ð4Þ
w = 0.2 mm are higher than those of w = 0.3 mm.
2 3 Fig. 4 shows the variation of the average heat sink temperature
T −T − T −T with air Reynolds number for different channel widths and different
¼4 5
s;ave a;ave;in s;ave a;ave;out
ΔTLMTD ð5Þ
Ts;ave −Ta;ave;in
ln Ts;ave −Ta;ave;out
channel heights. As expected, the heat transfer rate depends on the
cooling capacity rate of air. Therefore, the average heat sink
where Ts,ave is the average surface temperature, and Am is the surface temperature decreases as air Reynolds number increases. As seen in
area of the micro-channel heat sink. Fig. 3, due to the higher surface heat transfer area, the lower channel
Table 1 Table 2
Dimensions of the micro-channel heat sink Accuracy and uncertainty of measurements
Channel Channel height Fin and base thickness Channel width Size of heat Instruments Accuracy (%) Uncertainty
h (mm) s (mm) w (mm) sink (mm) Voltage supplied by power source, V 0.2 ±0.5
#1 1.00 0.20 0.20 40 ⁎ 28 Current supplied by power source, I 0.2 ±0.5
#2 1.00 0.20 0.30 40 ⁎ 28 Air flow meter 0.2 ±0.5
#3 1.50 0.20 0.20 40 ⁎ 28 Thermocouple type-T, data logger, (°C) 0.1 ±0.1
#4 1.50 0.20 0.30 40 ⁎ 28 Differential pressure transducer 0.02 ±0.02
42 P. Naphon, O. Khonseur / International Communications in Heat and Mass Transfer 36 (2009) 39–44
widths are close in the present study. In addition, average heat sink
temperatures at higher channel height are lower than those from
lower ones. Due to higher surface area and surface roughness, the heat
transfer rate from the heat sink surface to the cooling air increases.
Therefore, the increase channel height results in lower heat sink
temperatures.
Fig. 3. Variation of outlet air temperature with air Reynolds number for different
channel widths.
width heat sink gives average heat sink temperature lower than that
higher one. However, this parameter has slightly effect on average
heat sink temperature. The reason for this is that the micro-channel
Fig. 4. Variation of heat sink temperature with air Reynolds number for (a) different Fig. 5. Variation of average heat transfer coefficient with air Reynolds number for
channel widths (b) different channel heights. (a) different heat fluxes (b) different channel widths (c) different channel heights.
P. Naphon, O. Khonseur / International Communications in Heat and Mass Transfer 36 (2009) 39–44 43
Fig. 7. Variation of pressure drop with air Reynolds number for different channel
geometrical configurations.
5. Conclusions
Acknowledgements
References [25] A. Kosar, Y. Peles, Convective flow of refrigerant (R123) across a bank of micro pin
fins, International Journal of Heat and Mass Transfer 49 (2006) 3142–3155.
[26] A. Kosar, Y. Peles, Boiling heat transfer in a hydrofoil-based micro pin fin heat sink,
[1] H.P. Kayehpour, M. Faghri, Y. Asako, Effects of compressibility and rarefaction on
International Journal of Heat and Mass Transfer 50 (2007) 1018–1034.
gaseous flows in microchannels, Numerical Heat Transfer 32 (1997) 677–696.
[27] S.T. Tan, E.Y.K. Ng, Numerical analysis of EDL effect on heat transfer characteristic
[2] C.S. Chen, Numerical analysis of gas flow in microchannels, Numerical Heat
of 3-D developing flow in a microchannel, Numerical Heat Transfer 49 (2006)
Transfer 33 (1998) 749–762.
991–1007.
[3] M. Gao, D.M. Rowe, Cooling performance of integrated thermoelectric microcooler,
[28] K. Yukut, Experimental investigation of thermal resistance of a heat sink with
Solid - State Electronics 43 (1999) 923–929.
hexagonal fins, Applied Thermal Engineering 26 (2006) 2262–2271.
[4] K.H. Ambatirudi, M.M. Rahman, Analysis of conjugate heat transfer in micro-
[29] K.T. Chiang, F.P. Chang, Application of response surface methodology in the
channel heat sinks, Numerical Heat Transfer 37 (2000) 711–731.
parametric optimization of a pin fin type heat sink, International Communication
[5] E.Y.K. Ng, S.T. Poh, CFD analysis of double-layer microchannel conjugate parallel
in Heat and Mass Transfer 33 (2006) 836–845.
liquid flows with electric double-layer effects, Numerical Heat Transfer 40 (2001)
[30] M.M. Mohamed, Air cooling characteristics of a uniform square modules array for
735–749.
electronic device heat sink, Applied Thermal Engineering 26 (2006) 486–493.
[6] G. Guglielmini, M. Misale, C. Schenone, Boiling of saturated FC-72 on square pin fin
[31] S. Launay, Hybrid micro-nano structured thermal interfaces for pool boiling heat
arrays, International Journal of Thermal Sciences 41 (2002) 599–608.
transfer enhancement, Microelectronics Journal 37 (2006) 1158–1164.
[7] C.Y. Zhao, T.J. Lu, Analysis of microchannel heat sink for electronics cooling,
[32] I.M. Didarul, Study on heat transfer and fluid flow characteristics with short
International Journal of Heat and Mass Transfer 45 (2002) 4857–4869.
rectangular plate fin of different pattern, Experimental Thermal and Fluid Science
[8] J.J. Wei, H. Honda, Effects of fin geometry on boiling heat transfer from silicon chips
31 (2007) 367–379.
with micro-pin-fins immersed in FC-72, International Journal of Heat and Mass
[33] C.E. Zhen, Z.C. Hong, Y.J. Lin, N.T. Hong, Comparison of 3-D and 2-D DSMC heat
Transfer 46 (2003) 4059–4070.
transfer calculations of flow-speed short microchannel flows, Numerical Heat
[9] H.I. Choi, D. Lee, J.S. Maeng, Computation of slip flow in microchannels using
Transfer 52 (2007) 239–250.
Langmuir slip condition, Numerical Heat Transfer 44 (2003) 59–71.
[34] K.S. Yang, W.H. Chu, I.Y. Chen, C.C. Wang, A comparative study of the airside
[10] J. Luo, Optimum allocation of heat transfer surface area for cooling load and COP
performance of heat sinks having pin fin configurations, International Journal of
optimization of a thermoelectric refrigerator, Energy Conservation and Manage-
Heat and Mass Transfer 50 (2007) 4607–4613.
ment 44 (2003) 3197–3206.
[35] C. Hong, Y. Asako, Heat transfer characteristics of gaseous flows in a microchannel
[11] X.C. Xuan, Investigation of thermal contact effect on thermoelectric coolers,
and a microtube with constant wall temperature, Numerical Heat Transfer 52
Energy Conservation and Management 44 (2003) 399–410.
(2007) 219–238.
[12] H. Honda, J.J. Wei, Enhanced boiling heat transfer from electronic components by
[36] R. Chein, J. Chuang, Experimental microchannel heat sink performance studies
use of surface microstructures, Experimental Thermal and Fluid Science 28 (2004)
using nanofluids, International Journal of Thermal Sciences 46 (2007) 57–66.
159–169.
[37] C.S. Chen, Reduced Navier–Strokes simulation of incompressible microchannel
[13] Y.L. Hao, Y.X. Tao, A numerical model for phase-change suspension flow in
flows, Numerical Heat Transfer, 53 (2007) 71–87.
microchannels, Numerical Heat Transfer 46 (2004) 55–77.
[38] Z.C. Hong, C.E. Zhen, C.Y. Yang, Fluid dynamics and heat transfer analysis of three
[14] R. Chein, G. Huang, Thermoelectric cooler application in electric in electric cooling,
dimensional microchannel flows with microstructures, Numerical Heat Transfer
Applied Thermal Engineering 24 (2004) 2207–2217.
54 (2007) 293–314.
[15] T.Q. Feng, J.L. Xu, An analytical solution of thermal resistance of cubic heat
[39] S. Lineykin, S.B. Yaakov, User-friendly and intuitive graphical approach to the
spreaders of electronic cooling, Applied Thermal Engineering 24 (2004) 323–337.
design of thermoelectric cooling systems, International Journal of Refrigeration 30
[16] C.J. Kobus, T. Oshio, Development of a theoretical model for predicting the thermal
(2007) 798–804.
performance characteristics of a vertical pin-fin array heat sink under combined
[40] T.M. Jeng, S.C. Tzeng, Pressure drop and heat transfer of square pin-fin arrays in in-
forced and natural convection with impinging flow, International Journal of Heat
line and staggered arrangements, International Journal of Heat and Mass Transfer
and Mass Transfer 48 (2005) 1053–1063.
50 (2007) 2364–2375.
[17] O.M. Haddad, M.M. Abuzaid, Developing free-convection gas flow in a vertical
[41] Y.M. Lie, Saturated flow boiling heat transfer and associated bubble characteristics
open-ended microchannel filled with porous media, Numerical Heat Transfer 48
of FC-72 on a heated micro-pin-fined silicon chip, International Journal of Heat and
(2005) 693–710.
Mass Transfer 50 (2007) 3862–3876.
[18] H. Bhowmil, Convection heat transfer from discrete heat sourced in a liquid cooled
[42] W. Lee, G. Son, Bubble dynamics and heat transfer during nucleate boiling in a
rectangular channel, Applied Thermal Engineering 25 (2005) 2532–2542.
microchannel, Numerical Heat Transfer 53 (2008) 1074–1090.
[19] H.Y. Li, S.M. Chao, G.L. Tsai, Thermal performance measurement of Heat sinks with
[43] W. Lee, Y. Suh, G. Son, Bubble dynamics, flow, and heat transfer during flow boiling
confined impinging jet by infrared thermography, International Journal of Heat
in parallel microchannels, Numerical Heat Transfer 54 (2008) 390–405.
and Mass Transfer 48 (2005) 5386–5394.
[44] Q.W. Wang, C.L. Zhao, M. Zeng, Y.N. Wu, Numerical investigation of rarefied
[20] H.Y. Zhang, Single-phase liquid cooled micro channel heat sink for electronic
diatomic gas flow and heat transfer in a microchannel using DSMC with uniform
packages, Applied Thermal Engineering 25 (2005) 1472–1487.
heat flux boundary condition—Part I: numerical method and validation, Numerical
[21] M.B. Dogruoz, M. Urdanet, A. Ortega, Experiments and modeling of hydraulic
Heat Transfer 53 (2008) 160–173.
resistance and heat transfer of in-line square pin-fin heat sinks with top by-pass
[45] Q.W. Wang, C.L. Zhao, M. Zeng, Y.N. Wu, Numerical investigation of rarefied
flow, International Journal of Heat and Mass Transfer 48 (2005) 5058–5071.
diatomic gas flow and heat transfer in a microchannel using DSMC with uniform
[22] R. Chein, Y. Chen, Performance of thermoelectric cooler integrated with
heat flux boundary condition—Part II: applications, Numerical Heat Transfer 53
microchannel heat sinks, International Journal of Refrigeration 28 (2005)
(2008) 174–187.
828–839.
[46] L.F. Moody, Friction factors for pipe flow, Trans. ASME 66 (1944) 671–683.
[23] X. Yu, Development of a plate-pin fin heat sink and its performance comparisons
with a plate fin heat sink, Applied Thermal Engineering 25 (2005) 173–182.
[24] Y. Peles, Forced convective heat transfer across a pin fin micro heat sink,
International Journal of Heat and Mass Transfer 48 (2005) 3615–3627.