SCHEDULE_B

Costruction of Samudaya Bhavan near Madar Community Thadi at Indira Nagar


street for SC Community under SCP SAVINGS GRANT in Toravi Village of Vijayapur
Taluka of Vijayapur District for the year 2016-17

Item
Discription of Item Unit Qty Rate
No

KSRB 2-2.1: Earthwork in surface in ordinary soil


for levelling and lowering the ground mannualy
( other than foundation of buildings) and removing
the excavated stuff to a distance not exceeding 50 m
1 and lift up to 1.5m, Excavted surface levelled and
Cum 27.00 157.00
neatly dressed, disposed earth to be levelled after
breaking of clods and neatly dressed as per
specificatrion No KBS 2.1(a) /2.3.1

KSRB 2-2.1: Earthwork excavation for foundation of


buildings, culvers, water supply, sanitary lines and
electrical conduits either in pits or in trenches 1.5m
and above in width, in ordinary soil not exceeding
2 1.5m, in depth including dressing the bottom and Cum 114.64 188.00
sides of pits and trenches, stacking the excavated
soil clear from edges of excavation width lead up to
50m. after breaking of clods complete as per
specification

KSRB 2-3: Filling available excavated earth


(excluding rocks) in sides of foundation up to plinth
in layers not exceeding 20 cms in depth compacting
3 each deposited layer by ramming after watering with Cum 24.09 127.00
lead up tp 50m. And lift up to 1.5m including cost
of all labour complete as per specifications.
Specification No. KBS 2.9

KSRB 4-1.3; Providing, laying in position Plane


cement concrete of Mix 1:4:8 with OPC cement at
180kgs with 40mm and down size graded granite
metal coares aggrigates at 0.85cum and fine
aggregates @ 0.57 cum,machine mixed, concrete
4 laid in layers not exceeding 15cm thick, well
Cum 12.80 5126.00
compacted, in foundation , plinth and cills,
including cost of all material, labour, HOM of
machinery, curing as per specifications.
Specification No KBS 4.1, 4.2

KSRB 5-1.3 : Providing and constructing


granite/trap/basalt rubble stone masonry in
foundation with cement mortar 1:6 (uncoursed),
5 bond stones at two m apart in each course
Cum 18.95 3175.25
including cost of materials, labour, curing complete
as per specifications. KBS 5.1.12

KSRB 4.6.1: Providing and removing centering,


shuttering, strutting, propping etc., and removal of
from work for foundations, footings, bases of
6 Sqm 32.40 226.00
columns for mass concrete including cost of all
materials, labour complete as per specifications,
SPecification No. KBS 4.6.2
KSRB 4-6.5: Providing and removing centering,
shuttering, strutting, propping etc., for columns,
pillars, piers, abutments, post and struts, square /
7 rectangalur/polygon in plan including cost of all
Sqm 99.28 366.00
materials, labour complete as per specifications,
Specification No. KBS 4.6.2

KSRB 4-6.7: Providing and removing centering,


shuttering, strutting, propping etc., and removal of
form work for sides and soffits of beams, beam
8 haunchings, cantilever girders, berssumers and Sqm 83.29 256.00
lintels not exceeding 1m in depth including cost of
all materials, labour complete as per specifications,
Specification No. KBS 4.6.2

KSRB 4-6.2: Providing and removing centering,


shuttering, strutting, propping etc., and removal of
form work for flat surface such as suspended floors,
9 roofs, landings, balconies and likes thickness upto Sqm 91.75 307.00
200mm including cost of all materials, labour
complete as per specifications, Specification No.
KBS 4.6.2

KSRB 4.2.3: Providing and laying in position


reinforced cement concrete of mix M20 with OPC
cement @ 320kgs, with 20mm and down size graded
metal coarse aggregates 0.878cum and fine
aggregates 0.459cum, with supper plastisizer
@ 3Lts confirming to IS 9103- 1999 reaffirmed-
2008,machine mixed, concrete laid in layers not
exceeding 15cms thick, vibrated for all works in
foundation plinth and ground floor level for roof
10 Cum 38.90 6133.00
slabs, staircase, lintles, retaining walls, retrun
walls, walls (any thickness) including attached
plasters, columns, piers, abutments, pillars, posts,
struts, buttresses, string or lacing courses,
parapets, coping, bed blocks, anchor blocks, plain
window cills, fillets etc., including cost of all
materials, labour, HOM of machinery curing,
complete as pre specifications. Specification No.
KBS 4.1, 4.6

KSRB 4.9.2: Providing TMT Steel reinforcement for


RCC work including straightening, cutting, bending,
hooking, placing in position, lapping and/or welding
wherever requried, tying with binding wire and
11 anchoring to the adjoining members wherever Qtl 36.03 6995.87
necessary complete as per design (laps, hooks and
wastage shall not be measured and paid) cost of
materials, labour, HOM of machinery complete as
per specifications Specification No. KBS 4.6.3

KSRB 6.1.3: Providing and constructing brunt brick


masonry for basement and superstructure with
approved quality of non-modular bricks of standard
12 size of class designation 35 with cement mortar 1:6 Cum 6.98 5448.00
including cost of materials, labour charges,
scaffolding, curing complete as per specifications.
Specification No. KBS 6.2
KSRB 15.3.3: Providing 12mm thick cement plaster
in single coat with cement mortar 1:6 to brick
masonry including rounding off corners wherever
required smooth rendering, Providing and
removing scaffolding, including cost of materials,
13 labour, curing complete as per specifications.KSRB Sqm 191.69 155.55
15.4.4 E xtra for providing & mixing of W P C in
cement plaster work at one kg per bag or in the
proporsion recommeneded by manufacturers, for
CM 1:3, 18mm thick cost of materials complete as
per specifications

KSRB 15.14.1: Providing and applying two coats


with oil bond washable distemper of approved brand
and shade on wall surface including priming coat
with distemper primer after thoroughly brooming
14 Sqm 120.16 71.00
the surface free from mortar drops and other foreign
matter including preparing the surface even and
sand paper smooth, cost of materials, labour,
complete as per specifications.

KSRB 15.16.1: Providing and finishing external


walls in two coats with waterproof cement paint of
approved brand and shade to give an even shade
15 after throughly brooming the surface to remove all Sqm 33.26 69.00
dirt and loose powdered material, free from mortar
drops and other foreign matter cost of materials,
labour, complete as per specifications.

KSRB14-10-1: Flooring with 25mm to 40mm thick


polished tandur blue stone slabs using cement
mortor 1:6, 25mm thick over existing cement
concrete bed or top of the roof laid to line and level
16 Sqm 92.95 1109.10
and joined with cement slurry mixed with pigment
to match the shade of the slab including cost of
materials, labor, curing, polishing complete as per
specifications. specification no:14.8

Supplying Heavy gauge PVC conduit pipe


confirming to IS 2509 with suitable size bends,
junction boxes adhesive paste etc., and fixing using
inverted wood plugs in case of RCC ceilng and RCC
17 wall stone structures or rawl plugs in case of brick
Mtr 54.00 80.00
walls and cement platering damaged portion using
heavy guage saddles at an interval of 700mm using
NF screws. For 19/20mm dia 2mm thick

Wiring for lighting/power circuit using one of the


PVC Insulate 1100V grade, multistrand copper
18 Mtr 18.60 70.00
conductor single core cable in open or concaled
system of wiring. For 1.5 Sqmm Group A

Wiring for lighting/power circuit using one of the


PVC Insulate 1100V grade, multistrand copper
19 Mtr 29.20 140.00
conductor single core cable in open or concaled
system of wiring. For 1.5 Sqmm Group A

Wiring for lighting/power circuit using one of the


PVC Insulate 1100V grade, multistrand copper
20 conductor single core cable in open or concaled
Mtr 42.10 50.00
system of wiring. For 1.5 Sqmm Group A
Supplying wiring adopting loop system in existing
PVC conduit /Casing caping using copper PVC
insulated multi-strand 2X1.5sqmm copper wire
with 6amps flush type SP control switch shall be
21 fixed on the existing plastic sheet/gang box, the Point 174.00 6.00
other end of the wires shall be terminated with
sufficient loose length in awood/ round blocks.
complete for each outlet. For Short Point up to 3mtr
from tapping point to outlet via switch

Supplying wiring adopting loop system in existing


PVC conduit /Casing caping using copper PVC
insulated multi-strand 2X1.5sqmm copper wire
with 6amps flush type SP control switch shall be
22 fixed on the existing plastic sheet/gang box, the Point 245.00 3.00
other end of the wires shall be terminated with
sufficient loose length in awood/ round blocks.
complete for each outlet. For Short Point up to 3mtr
from tapping point to outlet via switch

Supplying wiring adopting loop system in existing


PVC conduit /Casing caping using copper PVC
insulated multi-strand 2X1.5sqmm copper wire
with 6amps flush type SP control switch shall be
23 fixed on the existing plastic sheet/gang box, the Point 363.00 3.00
other end of the wires shall be terminated with
sufficient loose length in awood/ round blocks.
complete for each outlet. For Short Point up to 3mtr
from tapping point to outlet via switch

Supplying and fixing polished wood board made of


not less than 15mm thick plank on both sides with
planks made out of not more than 2 pieces and
24 fixing the same to the wall using tapered inverted
Each 96.00 3.00
wooden plugs, screws etc.,. For 12" X 9" X 1.5"

Supplying and fixing polished wood board made of


not less than 15mm thick plank on both sides with
planks made out of not more than 2 pieces and
25 fixing the same to the wall using tapered inverted
Each 153.00 2.00
wooden plugs, screws etc.,. For 12" X 9" X 1.5"

Supplying and fixing polished wood board made of


not less than 15mm thick plank on both sides with
planks made out of not more than 2 pieces and
26 Each 177.00 1.00
fixing the same to the wall using tapered inverted
wooden plugs, screws etc.,. For 12" X 9" X 1.5"

Supplying and fixing a Group A drop light using one


PBBC/bakelite pendent holder, PVC insulated twin
twisted copper wire of 23/0.0076"upto 1Mtr, one of
27 60/100 watts lamp of 230 volts grade and one of 5
Each 121.00 4.00
amps bakelite ceiling rose fixed on the existing
wooden block of the outlet.
Supplying & fixing Group A PBBC brass/ Bakelite
straight or slant batten holder & wiring, within
28 60W/230V lamps. Each 88.00 4.00
Supplying and Fixing of 32Amps Group A Fuse
channel with cutouts on the existing wooden using
29 necessary nuts, bolts and washers.Etc., Complete.
Each 180.00 2.00

Supplying 6A 3/5way flush /projected type socket


and a 6A flush /projected type switch either surface
30 mounting in a gang box or in a 4mm think plastic Each 106.00 6.00
sheet and fixing over a wooden box and wiring using
necessary capacity wires as required.

31 Supplying of Wooden Gutta. Each 23.00 10.00

Supply Box type fluorescent tube light fitting of


1X4'- 36/40 watts Group A fluorescent tube fitting,
made out of M.S sheet and stove enameled with low
loss open construction copper wound ferromagnetic
32 ballast,starter, locking type brass contact holders
Each 669.00 8.00
mounted on double fold type sheet base fully wired
for use on 230 Volts A C Supply including
fluorescent tube.

Supplying 48" capacitor type ceiling fan complete


with down rod blades, shackle, canopies etc., for
operation on 230 volts, 50 cycles. Single phase AC
33 supply conforming to ISS-374-1979 and with double
Each 1980.00 6.00
ball bearing system and as per technical data
approved.(23/23)

Fixing all types and all capacities of


fluorescent/false ceiling/spot light/CFL fittings
indoor on the wall / ceiling/ rafters / girders using
34 Each 98.00 6.00
23/0.0076” twin twisted PVC insulated wires,
required Nos of round blocks and clamps (if
required)

Supplying of Class A PVC 4c X 16 sqmm LT UG


class-A PVC cable having aluminium conductor PVC
35 insulated, sheathed, galvanised, steel wire/steel tap Rmtr 150.00 25.00
armoured cable with PVC outer sheathing 1.1 KV
class.

Labour charges for laying of 4c X 15 Sq.mm 1.1KV


class UG Cable in existing trench 2.5 Sqmm to 7.5
36 Sqmm supplied departmentally agency in existing
Rmtr 11.00 25.00
trench as required.

Digging of trench of 0.6m deep x 0.50 mtr wide hard


soil refiling the trench to the required ground level
37 and consolidating etc., complete.(As per Civil SR
Rmtr 50.00 8.00
KSRB I-2, P-7)(70/6)

Supplying and fixing of class A (medium duty)


40mm GI pipe of wall thick ness not less than
38 3.25mm on pole/wall/drain crossing with necessary Rmtr 240.00 2.00
clamping arrangements for UG cable of 1.1 KV
class.

Supplying and fixing of heavy 25 Sqmm Duty cable


39 gland s suitable for UG Cable of 1.1 KV class (metal Each 66.00 2.00
only)
Supplying, fixing, wiring, earth electrode for
grounding conduits, I.C. cutouts and other
equipments on the meter board using 40mm dia
2.90mm thick GI pipe 2.5 mtr long buried in a pit
… The pit should be filled with equal proprotion of
40 salt and charcoal 150mm alround the pipe to Each 1950.00 2.00
complete depth. The connection from the pipe to the
conduit etc, is to be established through GI wire of
size as per ISI specification 7.3.3. of IS 732 using
12mm dia bolts, nuts, washers and checknuts etc,
the pipe shall have 16 through holes of 12 mm dia.

Supplying and running 10SWG GI conductor for


grounding and (along with other wires in conduit
41 Rmtr 16.00 16.00
system of wiring) using necessary suitable size
clamps, nails, guttas/spacers etc.,

Supplying and fixing 16 Sqmm L.T. cast Iron pot


heads suitable for 1.1 KV class UG cable filled with
42 necessary bituumen/insulating compound complete Each 260.00 1.00
with terminals, clamps, bolts, nuts and washers etc.
(70/10)

Supplying 250 watts Group A High pressure sodium


vapour street light fitting die cast alluminium
canopy with aluminum housing for control gear,
finished stove enamel gray glassy white canopy
43 interior with a pair of anodized aluminum reflectors Rmtr 6150.00 1.00
clear acrylic bowl, gasket lining for drip inseat
resistance duly wired with porcelain holder copper
choke, igniter and HPF condenser including a
sodium vapour lamp.(19/12)

Fixing a ceiling/wall mounting fan of all capacities


and all types with necessary clamps and S hook
made out of 15mm dia MS rod, with 5 amps ceiling
44 rose of approved quality with necessary length of 23 Each 210.00 6.00
/ 0.0076 inch PVC insulated twin twisted wire of
approved quality mounted on a suitable size
wooden board and wired complete. (29/9)

Supplying and Fixing 32 mm dia class A GI pipe


bracket up to 2.7 meters long terminated with a
reducing collar of 40x25mm to which extra pipe of
175mm length is fixed for fixing MV/SV/MH/FTL
45 Rmtr 885.00 1.00
street light fitting of all capacities on
rail/RCC/wall/tubular pole, using suitable clamps,
bolts ,nuts and wiring using suitable capacity wires
etc complete.(28/2)

Supplying of 32AMPS Group -A TPST with


46 Each 1450.00 1.00
rewirable porcelain channels in SM enclosure.(32/1)

Fixing of 32Amps TPST / change over switch/


Contactor along with neutral link with screws, bolts,
47 Each 165.00 1.00
nuts and wiring using required capacity wires and
circuit labeling.(30/16)

Supplying and fixing regular 8way TPN Group A


MCB distribution boards on wall / wood board /
flush mounting using required clamps, bolts, nuts
48 Each 6440.00 1.00
etc., with provision for fixing suitable type capacity
MCB's single phase / 3 phase / single door with
powder coated painting etc., complete .(36/11)
Supplying and fixing miniature circuit breakers on
existing MCB distribution boards using necessary
fixing materials and 'C' Type curve , indicator
49 ON/OFF, energy cross-3 with Short circuit breaking
Each 1005.00 1.00
capacity of 10K and complete wiring as required.
(36/12) For 5-32 Amps TPN Group A

Supplying and fixing miniature circuit breakers on


existing MCB distribution boards using necessary
fixing materials and 'C' Type curve , indicator
50 Each 195.00 2.00
ON/OFF, energy cross-3 with Short circuit breaking
capacity of 10K and complete wiring as required.
(36/12) For 5-32 Amps TPN Group A

Supplying and fixing miniature circuit breakers on


existing MCB distribution boards using necessary
fixing materials and 'C' Type curve , indicator
51 Each 195.00 2.00
ON/OFF, energy cross-3 with Short circuit breaking
capacity of 10K and complete wiring as required.
(36/12) For 5-32 Amps SP Group A

Grand Total Amount In Rs.

Executive Engineer
KBJNL, MLI, Division-2
Babaleshwar
adi at Indira Nagar
vi Village of Vijayapur

Amount In RS

4239.00

21552.32

3059.43

65612.80

60170.99

7322.40
36336.48

21322.24

28167.25

238573.70

252061.20

38027.04
29817.38

8531.36

2294.94

103090.85

4320.00

1302.00

4088.00

2105.00
1044.00

735.00

1089.00

288.00

306.00

177.00

484.00

352.00
360.00

636.00

230.00

5352.00

11880.00

588.00

3750.00

275.00

400.00

480.00

132.00
3900.00

256.00

260.00

6150.00

1260.00

885.00

1450.00

165.00

6440.00
1005.00

390.00

390.00

983103.38

e Engineer
I, Division-2
Costruction of Samudaya Bhavan near Madar Community Thadi at
Indira Nagar street for SC Community under SCP SAVINGS GRANT
in Toravi Village of Vijayapur Taluka of Vijayapur District for the year
2016-17(indent No 16799)

:” Construction of Shri Haralayya community Samudaya Bhavan near Maremma


Temple at Samagar street for SC Community under SCP SAVINGS GRANT in Toravi
Village of Vijayapur Taluka of Vijayapur District for the year 2016-17”(indent No
16797)

Construction of Community Hall near Lalsaheb Temple of Madar


street under SCP SAVINGS GRANT in Toravi Village of Vijayapur
Taluka of Vijayapur District for the year 2016-17”(indent No 16798)

Construction of Ambedkar Samudaya Bhavan near Grama


Panchayata building for SC Community under SCP SAVINGS
GRANT in Toravi Village of Vijayapur Taluka of Vijayapur District for
the year 2016-17 (Compound Wall and First fioor)”(indent No 16796)