Sei sulla pagina 1di 1

CTP Side-Mounted Fluid level Switch #172-8660

Dimensional Data - Type 6


Fitting Detail R 010-040
#22 AWG
PVC Wire Customer Housing
24” to 26” Ext. .875 - 14
3-3/8”
UNF-2B
1.40” Ref.
Ref. Thread
1.00* .896** 45°
120°
DIA. DIA.
1.36”
Ref.
+.015* +.005**
7/8” - 14 Jam Nut
-.000 -.000 .450 REF.
3/8” Ref. 7/8” - 14 .107
UNF Thd.
1 -1/8” Note
11/16” Mating housing requirements for #3-910 O-ring (P/N 11121)
HEX
Ref.
Ref.

Mounting of level switch


Typical Wiring Diagram

O-Ring
Not Included
Washer
(Supplied)
Red
Red

Jam Nut 7/8” - 14 Thd. N.O. or N.C. (Dry)


(Supplied)
Customer Housing
(See Fitting Detail)

FLOAT ARC Normally


Switch Operation ENVELOPE
Normally Open Closed
Depending on the mounting position, the float
on these switches can either rise or lower with
the liquid level. By rotating the switch 180°, When the switch is mounted so
the switch operation can be Normally Open or that the float rises with the
Normally Closed. Arrows on exterior of When the switch is mounted so liquid level, the switch is N.C.
mounting indicate N.O. when pointing up. that the float lowers with the
liquid level, the switch is N.O.
.625 Max. mtg. dim.

Maintenance
Normally, no maintenance of any kind is required.
When excessive contamination is present in the
liquid, an occasional wipe-down cleaning is all
that is needed.
Unit shown installed Unit shown installed
“Float Down” for N.O. “Float Up” for N.C.
(Dry) Operation (Dry) Operation
European Pressure Directive Addendum
The product is designed and manufactured in accordance with Sound Engineering Practice as defined by the Pressure Equipment Directive 97/23/ec.
This product must not be used as “safety accessory” as defined by the Pressure Equipment Directive, Article 1, Paragraph 2.1.3. The presence of a
CE Mark on the unit does not relate to the Pressure Equipment Directive.

WI-720-047

Quality Products