Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
VisionVertiCool
NE W M O D E L AVA I L A B L E
GAS
TheG20
Vision features clean lines in a contemporary, eye-catching style that will complement
- GROUP H / G25 GROUP L
any décor with and no sight of an outdoor condenser it makes the unit ideal
for hotel rooms, restaurants and many other hospitality applications.
OI L 35 SEC FUEL (STANDARD) 28 SEC FUEL (OPTIONAL)
Standard Models
Packaged Technology (all models are WiFi enabled)
The need for air conditioning today is present winter and
summer. All too often this means installing unsightly • Vision 2.3 DW
condensing units on the exterior of buildings. • Vision 3.1 DW
• Vision VertiCool 3.1 DW • Lorem ipsum dolor sit amet
The Powrmatic Vision is a packaged solution which removes • Vision 3.1 DW/H (Low Temperature Resistance Heater)
the need for an outdoor unit, and incorporates state of • Vision LTHW ( Fan coil model)
the art “monobloc” technology. The Vision also does not • Vision DWM ( Marinised model. Special order only-MOQ
require a F-Gas certified engineer to install saving you as 50 Units )
significant amount on installation costs.
Installer Benefits
• No external condenser required
• Quick and simple installation
• No re-decoration costs
• Supplied with 13A standard BS plug top
• No requirement for internal and external pipework
• Easy maintenance access
• No F-Gas certificate to install
2
T Y P I C A L A P P L I C A T I O N S
T Y P I C A L A P P L I C A T I O N S
••Warehouses
Hotels
••Factories
Offices
••Gara
Restaurants
ge Workshops
••Distribut
Garden buildings
ion Centres
• Portable buildings
••Aircr aft Hangers
Apartments
• Domestic houses
• Listed buildngs
No Outdoor Condenser
The Vision requires no external condenser, saving
you costs on installation and improving the aesthetic
appearance of your building. The 160mm twin duct,
and a 14mm
condensate pipe hole reduces the outdoor impact of
air conditioning systems and seamlessly integrates
into any
exterior building design. As a result, there is mini-
mum impact on the building’s exterior and complies
with many regulations on listed buildings.
Retro- Fit Installation
The Vision can be retrofitted into many applications
where there is a current A/C system. With no
Heating Or Cooling Options requirement for an external condenser, and
Each Vision model has the ability to heat and cool extensive pipework, upgrading an existing split air
your building from -6°c to 31°c conditioning system is simple.
P R O D U C T B E N E F I T S
C U SNo
T requirement
O M E Rfor an
B external
E N Econdenser
F I T S•
Ability to both heat and cool •
Lcon sectetur ad ipiscing el it, sed do eiusmod tempor incid idunt ut labore et dolore WiFi magna
enabled al
control
iqua.••
Touchscreenvel
Duis aute irure dolor in reprehenderit in voluptate & it
remote
esse control
cil lum••
16°c to 31°c temperature range •
Lorem ipsum dolor sit amet, consectetur ad ipiscing el it, •
Programmable timer control •
Lcon sectetur ad ipiscing el it, sed do eiusmod tempor incid idunt ut labore et dolore magna al iqua. •
3
Your Space. Your Choice.
The units employs new techniques and technology to precisely follow the curves of the design, all the
way to the elegantly rounded corners. The smooth, polished white PPC finish allows the unit to fully
complement any room decor and design.
L ow Wa l l H i g h Wa l l
NEW
DESIGN
Dimensions
4 C ONT ROL
Vertical Installation
Vision VertiCool
The Vision VertiCool 3.1kW is the latest in the range with a new and stylish vertical approach that can
be installed in areas between windows, or in room corners making it the perfect alternative for those
rooms where space and access to an external low or high wall is limited.
The VertiCool is installed the same as the standard unit with an impressive depth of only 185mm
allow it to integrate seamlessly into any room.
Ve r t i c a l
NEW
PRODUCT
Dimensions
5
Through The Wall Installation
Each Vision unit benefits from simple installation that requires no down-time or loss of revenue
for building owners whilst also reducing the re-decoration costs after the use of cable runs and
external condensers after the installation. With no F-Gas certificate requirement this significantly
reduces the overall installations costs.
The Vision range is the perfect solution for retro-fitting and can be the ideal replacement in many
rooms offering both heating and cooling. Each unit is supplied with a 13A standard BS plug top.
2
1
293mm
F i x t h e s u p p o r t i n g b r a c k e t t o t h e w a l l , i n se r t
Mount t h e provided pa per t empl a t e l evel t h e p l a s t i c l i n i n g s l e e v e s t h ro u g h t h e du c t
to t he desire d wal l a nd ma r k t he 6 x f i xi ng h o l e s . At t a c h t h e p l a s t i c i n d o o r f l a n g e s an d
b rac ke t h oles, 2 x 160 mm d i m et er duct hol es t h e n f i x t h e s e l f f o l d i n g o u t d o o r g r il l e s
a nd t h e 14mm c ondens a t e hol e. f ro m i n s i d e t h e b u i l d i n g .
3 4
13A
So ck e t
6
Controlling Your Environment
The mobile APP allows the management of the unit from remote
positions through WIFI such as a hotel reception desk controlling
multiple units from one location.
R em ot e Touch Screen ( h a rd - w i re d )
m
60m
NEW
R em ot e Cont rol LARGER
CONTROLLR
IO S or A ndroi d A pp
15
0m
m
CON TR O L
7
No Outside Condenser
Concealed Model
8
On specialist projects of over
50 units, the external grilles can
be painted to any BS or RAL
number to blend in with the
buildings exterior walls.
9
Mobile App Control
The Vision WiFi mobile app now lets you control multiple units from your smartphone device
or tablet via your local WiFi network.
The easy to use app displays current temperature settings and allows the user to change
temperature, fan speed, and air flow direction from anywhere at a touch of a button.
In applications such as hotel buildings, the reception desk can activate, control, and
deactivate each unit in every room depending on the occupancy.
They can warm up or cool down the room before hotel guests arrive, and ensure the units
are switched off when the room is unoccupied saving valuable energy consumption. Building
owners can also utilise the weekly scheduling function to quickly and efficiently set desired
settings for the whole week.
10
11
Air Movement
Warm or cold internal air is efficiently distributed via the independent oscillating vane at the
front of the unit by internal evaporator fan dependent on the desired room temperature
requirement. The conditioned air is then returned to the room to provide comfort cooling or
reverse cycle heating.
Outdoor air is drawn in via the external inlet grille which cools the hot condenser in cooling
mode, this in turn provides ambient heat to the condenser coil when reverse cycle heating
mode.
0.72 kW 3.05 kW
comfort function.
Input Output
12
Typical Room Coverage
(General guide only)
This is a guide and is intended to provide general information only. Factors such as building
fabric, and orientation will significantly contribute to the selection. Powrmatic strongly
recommends you contact our sales team for accurate product selection and sizing.
2.3kW 3.1kW
Maintenance
Maintenance is simple with every Vision model. The opening grille panel on the top can
be detached and the units filters are easily accessible for cleaning and maintenance. With
very little moving parts, the packaged unit limits maintenance contracts which is backed
up with a comprehensive range of replacement parts at our warehouse.
13
Additional Heat Model (DW/H)
As all heat pumps have lowering performances in heating when outdoor temperature is
falling, sometimes their is request is to have a consistent heating capacity with extremely
low outdoor temperatures.
The Vision DW/H integrates (not replaces) the heat pump with an additional 1 kW electrical
heater that intervenes automatically when outdoor temperatures become extremely low.
Because of this the DW/H can deliver a heating capacity of at least 2kW even with outdoor
temperatures down to -7°C, with an energy absorption of 1kW that is extremely low and
fully compatible with standard domestic power supplies.
The Vision DW/H can be considered a complete heating system even with severe outdoor
temperature.
Power Consumption
V ision DW/H
V ision 3.1
Te mperatu re
Dimensions
14
Fan Coil Model (LHTW)
The Vision LTHW one single body integrates both an air conditioning system for summer
Controlling Your Environment
cooling and winter heating, and a fancoil for winter heating with low temperature hot water
systems.
It is now possible to replace a standard radiator system, with the advantage to have comfort
both in summer and in winter.
In winter time, heating is supplied by the heat pump functioning mode; when outdoor
temperatures decrease, the LTHW automatically integrates the heat pump functioning with a
fancoil to maintain the set temperature. In cases where external temperatures become
particularly low, heating with the fancoil only can be set.
Dimensions
15
Installations
Specialist Project Units
(minimum order quantity of 50)
SPECIAL
Vision DWM Marinised Modelnits ORDER
ONLY
All components near sea are exposed to corrosive, salty air and must meet special structural
requirements. The Vision DWM is a full protected air conditioning unit utIlising a copper/
copper condenser and evaporator coil, stainless steel chassis, cabinet and assembly
components, to, prolong the life of the unit in harsh saline conditions make the Marinesed
Vision perfect for coastal and high ambient tropical conditioners.
Dimensions
16
Installations
17
Installations
18
Technical Specification
Technical Data U.M 2.3 DW 3.1 DW 3.1 VertiCool DW 3.1 DW/H LTHW
Cooling Capacity - Dual Power Max / Min kW 2.6 / 0.8 3.1 / 0.9 3.1 / 0.9 3.1 / 0.9
Heating Capacity - Dual Power Max / Min kW 2.64 / 0.7 3.05 / 0.8 3.05 / 0.8 3.05 / 0.8 Refer To Model
Dimensions (W x H x D) mm 1030 x 555 x 165 1030 x 555 x 165 500 x 1398 x 185 1030 x 555 x 165 1030 x 555 x 143
Noise Level (Min / Max) dB(A) 26 / 39 27 /41 27 /41 27 /41 Refer To Model
Wall Hole Diameter / Condensate Drain mm 162 / 14
The nebuliser is fitted underneath the unit and Vision Wired Controller
effectively heats the condensate air, turns it to Vision Remote Control (provided with unit)
Capacity L/h 2
C o n d e n sat e Ne bu l i se r
E x t e r n a l Gr i l l e s
Darryl Redfearn
Dedicated AIr Conditioning Sales - Northern Region
HS 07531 342 154
KW
darrylredfearn@powrmatic.co.uk
IV
Tony Delaney - Ireland
+(353) 0866 040 613
AB tonydelaney@powrmaticireland.com
DL TS
IM Martin Arden - Midlands
LA 07971 079 717
BT HG YO
BD
martinarden@powrmatic.co.uk
FY PR BB LS HU
HX
L WN
BL
OL
HD
WF
DN
Chris Spencer- South East
M
REPUBLIC WA
SK S 07525 912 220
OF IRELAND LN
CH CW chrisspencer@powrmatic.co.uk
LL
NG
ST DE
TR
London KT
SM
CR
Head Office
Powrmatic Limited tel: +44 (0) 1460 53535
Hort Bridge fax: +44 (0) 1460 52341
Ilminster e-mail: info@powrmatic.co.uk
Somerset web: www.powrmatic.co.uk
TA19 9PS
#keepingthenationwarm
Powrmatic pursues a policy of continues improvement in both design and performance of its products and therefore reserves the right to change, amend or vary specifications
without notice. Whilst the details contained herein are believed to be correct they do not form the basis of any contract and interested parties should contact the company to
confirm whether any material alterations have been made since publication of this brochure.