TM-Navigator
User’s Manual
Read this manual before using the system in order to achieve
maximum performance.
Keep this manual in a safe place after reading it so that it can
be referenced at any time.
Safety Precautions
This manual explains the functions, usage, and configurations for TM-H1 <TM-Navigator>, Setup software for the TM-
3000 Series. Read this manual carefully before starting to use the software to ensure the optimum performance and full
functionality of the <TM-Navigator>. Keep this manual in a safe place for future reference.
Read the TM-3000 Series User's Manual as well as this manual when using the <TM-Navigator>. The controller portion
of the TM-3000 Series is referred to as the "controller" in this manual.
Symbols
This manual indicates symbols as follows.
Reference
Provides advanced and useful information for operation.
Contents
Contents
96050E 1
Contents
MEMO
Getting Started
Getting Started
This chapter describes installing or uninstalling the TM-Navigator,
installing the USB driver, and connecting the controller to a computer.
The following computer environments are necessary to This section describes how to install the TM-Navigator
use the TM-Navigator. and "USB driver" to a computer.
• CPU:
Pentium III 1GHz or more (1.7GHz or more
Before Installation
recommended) Check the following items before installing.
• Supported OS:
Reference
Windows 10*1
• We recommend making a backup of the master disc in
Windows 7 (SP1 or later)*2
case the CD-ROM becomes damaged.
Windows Vista (SP2 or later)*3
• Close all programs before installing.
Windows XP (SP3 or later)*4
• Memory capacity:
512MB or more (1GB or more recommended) User privileges
• Display:
• For Windows XP
XGA (1024 x 768 pixels) or greater, 256 colors or
When TM-Navigator is installed into the default folder
greater
(C:\Program Files\Keyence\TM-Navigator\), set the
• Hard disk drive space:
following access privileges.
1GB or more
Users must be given rights for “User” or greater in
• Interface*5:
order to use TM-Navigator.
Includes one of the following:
• For Windows VISTA/7/10
USB2.0/1.1*6 or Ethernet*7
When TM-Navigator is installed into the default folder
(C:\Program files\Keyence\TM-Navigator\), set the
* Use this software in recommended environments
following access privileges.
according to your OS.
Users must be given rights for "User" or greater in
*1 Compatible with each edition of Home, Pro, and
order to use TM-Navigator.
Enterprise.
*2 Compatible with each edition of Home Premium, Free space on the hard disk
Professional, Ultimate.
TM-Navigator can only be installed on a hard disk drive.
*3 Compatible with each edition of Ultimate, Business,
The hard disk drive where the software will be installed
Home Premium and Home Basic.
must have at least 1GB of free space. If there is
*4 Compatible with each edition of Professional and
insufficient free space, delete unnecessary items to
Home Edition.
secure the free space.
*5 Select one for communication. Multiple interfaces
cannot be used for communication at the same time. Pre-installation Windows environment
*6 Function is not guaranteed when connected through
TM-Navigator is a Windows application and the software
a USB hub.
is installed in Windows. Check that a supported OS is
*7 Function is not guaranteed when connected through
installed on the computer and is working properly.
a router or a LAN connection.
Getting Started
Installing TM-Navigator Uninstalling TM-Navigator
Reference Reference
Log onto the computer as a user with "Administrator" Log onto the computer as a user with "Administrator"
privileges for installation. privileges for uninstallation.
3 Follow the directions on the installation 4 Click [Yes]. TM-Navigator is uninstalled from the computer.
program for installation.
Reference
• The driver necessary for the USB connection is
installed.
• TM-Navigator installation folder
When installing TM-Navigator with the default
settings, the program is installed into the following
folder:
C:\Program files\Keyence\TM-Navigator\
This section describes how to start and exit TM-Navigator. Step 2-1 When [Start up with the default values] is
selected
Reference Select [Start up with the default values] the first time that
• Multiple instances of TM-Navigator cannot be started TM-Navigator is started up or when creating a new
up at the same time. program.
• The USB and Ethernet interfaces on a single controller
cannot be used at the same time. Use the following procedure to start up.
• Communication is disabled when the controller is in the
"Program mode". 1 Select [Start up with the default values]
and click the [OK] button.
Start
TM-Navigator starts up in one of the following methods:
• Start up with the default values
• Read from a file
• Read the settings of the connected controller
Reference
Click the [Exit] button to exit TM-Navigator.
Getting Started
Step 2-2 When [Read from a file] is selected
When [Read from a file] is selected, TM-Navigator loads
3 Select [Read Environment Setting] or
select [Start Environment Settings with
a program file and an environment setting file that have
been saved on the computer.
default setting].
The operation procedure will differ depending on the
1 Select [Read the settings of the 1 Select [Exit] from the [File] menu.
connected controller] and click the
[OK] button.
Reference
If the settings have been changed, make sure to
save the program file and environment setting file
before exiting TM-Navigator. The changes will be
lost if the files are not saved before exiting.
"Reading and Saving Setting Files" (page 3-2)
Reference
In order to read the controller settings, communication
Reference
must be established between the controller and
If the [No] button is clicked, TM-Navigator exits without
computer beforehand.
saving the settings.
"Connecting via USB" (page 1-7)
"Connecting via Ethernet" (page 1-9)
Getting Started
This section describes how to connect the controller to a
computer with a USB connection.
Configuring Communication Settings
Connection Method
1 Start up TM-Navigator.
Use a USB cable (included). 2 Select [PC communication setting]
from the [Comm settings] menu.
The [Comm settings] dialog appears.
I/O
OUT
TM-3
POW
ON
000
ER
SD
USB
CARD
CONS
MONI
HEAD
-B
-A
OLE
TOR
2C
RS-23
RNET
ETHE
Reference
• Install the USB driver when connecting the computer
and controller with the USB interface for the first time.
"Installing the USB Driver" (page 1-8)
• Do not remove the USB cable while the controller is
running. Otherwise, the controller may not function
correctly. If the communication is disabled due to
accidental disconnection of the USB cable, restart both
TM-Navigator and the controller.
Installing the USB Driver 4 Select [Search for the best driver in
these locations.] and check the box
This procedure is not required because the installer
installs the USB driver when installing application next to [Include this location in the
software. search:].
If the driver installation is cancelled while installing the Then, enter "C:\Program Files\KEYENCE\TM-
application software, follow the procedure below to Navigator\driver" in the text box and click the [Next]
manually install the USB driver. button.
Installing on Windows XP
Connect the controller to a computer with Windows XP. If
the controller is being connected for the first time, the
USB driver for the TM-3000 Series must be installed. The
connection is automatically recognized after the USB
driver has been installed once and does not need to be
installed again.
This section explains how to install the driver for the TM-
3000 Series on a computer with Windows XP for the first
time.
Hardware detection must be performed when installing Reference
2 Connect
When installation of the USB driver ends
the USB port on the computer successfully, the [Completing the Hardware Update
with the USB port on the TM-3000 Wizard] dialog appears.
Series controller using the USB cable.
The message "Found New Hardware" appears and 6 Click the [Finish] button to complete
installation of the USB driver.
the Hardware Update Wizard starts up.
Getting Started
This section describes how to connect the controller to a
computer with an Ethernet connection. When using Ethernet
Configuring Communication Settings
communication, one computer can be connected to multiple Set the following communication settings when
controllers. One of the connected controllers can be selected communicating with Ethernet.
for communication. The communication protocol is TCP / IP, • IP address
while the connection uses peer-to-peer communication. Configure unique addresses for the computer and each
Reference controller. Do not set 0.0.0.0 or 255.255.255.255 for the
• Configure the settings so that there are different IP IP address.
Ex.: When using two controllers and one computer
addresses used for the computer and each controller
Controller No. 1 192.168.0.10
on the network.
Controller No. 2 192.168.0.11
• function is not guaranteed when connected through a
Computer 192.168.0.12
router or a separate LAN connection.
• Subnet mask
• One computer cannot communicate with multiple
Configure the same settings on the computer and
controllers at the same time.
controllers. Use the default value normally.
• Multiple computers cannot be connected to one controller. (Default: 255.255.255.0)
• Do not set 0.0.0.0 or 255.255.255.255 for the IP address. • Default gateway
Use the default value normally.
Connecting (Default: 0.0.0.0)
Connecting one controller directly to one 1 Set the Ethernet settings for the
controller.
computer
Set the IP address, subnet mask, and default
Use a commercial Ethernet cross cable (*) for connection. gateway.
* Use cables supporting the communication speed. For more information about configuring settings, see
"TM-3000 Series User's Manual".
Cross cable
Reference
CONS
OLE
Restart all of the controllers after configuring the
000 TOR
MONI
TM-3
CARD
SD
-B
HEAD
OUT
settings.
USB
-A
HEAD
2C
RS-23
RNET
ETHE
Ethernet connector Ethernet port 2 Set the Ethernet settings (TCP / IP) for
the computer.
The method for configuring the settings depends on
Connecting to two or more controllers the version of Windows. For more details, see the
instruction manual for the computer or LAN card.
A 1000BASE-T / 100BASE-TX / 10BASE-T hub is required
to connect to two or more controllers. Use commercial
Ethernet straight cables to connect between the hub and 3 Starts up TM-Navigator.
"Starting and Exiting TM-Navigator" (page 1-4)
the computer or controllers.
Hub
4 Select [PC communication setting]
from the [Comm settings] menu.
The [Comm settings] dialog appears.
OLE
CONS
000 TOR
MONI
TM-3
ER
POW
ON
I/O
CARD
SD
-B
HEAD
OLE
CONS
OUT
USB
000 TOR
MONI
TM-3 -A
ER HEAD
POW
ON
2C
I/O RS-23
CARD RNET
Ethernet port
SD
ETHE
-B
HEAD
OUT
USB
-A
HEAD
2C
RS-23
RNET
Straight cable
ETHE
Ethernet connector
Reference
Turn the controller on beforehand and check that it is
communicating properly.
(1) Select [Connected controller] and click the [Check
connected controller] button.
192.168.0.10
192.168.0.11
192.168.0.13
Main Window
Main Window
This chapter describes the names and functions of each part of the
TM-Navigator main window and how to operate them.
Main Window
(1)
(2)
(3) (5)
(4)
Main Window
"Data Storage" (page 4-13)
Configures the settings for storing measured image data in the controller.
Stored image data can be displayed on TM-Navigator or saved as a file on the computer.
"Image Storage" (page 4-19)
The settings for the selected program No. can be checked and changed. (Program No.)
No. 0 to 15
Clicking on the selected program No. changes the color of the button to blue.
Clicking on this button displays the [Edit program name] dialog. Set the program name in this
dialog box.
Edit program name Reference
• Enter up to 16 characters for the program name.
• Letters and numbers can be used for the program name.
Copy Copies the settings* in the currently selected program No. for pasting.
Pastes the settings* that were copied by using the [Copy] button into the program No. that is
Paste
being edited.
Initialization Initializes the settings* in the currently selected program No.
Global initialization Initializes the settings* for all of the program No. 0 to 15.
* "Copy", "Paste", and "Initialization" act on the following settings:
• Head Settings
• Master Registration (including the master image)
• Position Correction
• Measurement Settings
• OUT Settings
• Common Settings
Reference
For more information about each setting, see "TM-3000 Series User's Manual".
Reference
• If a previously saved program file exists with the same
name, the file is overwritten.
Reading and Saving Environment Setting Files Saving environment setting files
Reference
If a previously saved environment setting file exists with
the same name, the file is overwritten.
communication is normal.
"Connecting via USB" (page 1-7)
"Connecting via Ethernet" (page 1-9) The [Communicating] dialog appears.
The dialog closes when receiving the settings is
2 Click the [Send settings to controller]
icon on the tool bar.
complete.
Alternative
Select [Send the settings to the controller] from the
[Comm] menu.
This section describes displaying the values measured with the controller in real time on the TM-Navigator.
(1)
(3)
(2)
(4) (5)
Displayed while the measurement value acquisition is stopped. Click this button to start
receiving measurement values.
Displayed while the measurement values are being received. Click this button during
measurement to stop receiving the values.
For more information about each control signal, see "TM-3000 Series User's Manual".
Operating the [View measurement value] 3 Click the [Measurement value acquisition
start] button.
window
The measurements for the OUT settings that are
the target.
"Connecting via USB" (page 1-7)
"Connecting via Ethernet" (page 1-9)
Reference
• If communication is not possible between TM-Navigator
and the controller, or if a head is not connected, the
following dialog appears shortly after clicking the
The [View measurement value] window appears. [Measurement value acquisition start] button or
[Trigger] button.
Alternative Check the connection between each head and
• Select [View measurement value] from the between TM-Navigator and the controller.
[Display] menu.
View Image
This section describes displaying images that are being measured with the controller in real time on the TM-Navigator.
(8) (10)
Displayed while the image capturing is stopped. Clicking the button starts capturing the
image being measured by the controller into TM-Navigator.
Displayed while the image capturing is proceeding. Image capturing is stopped by clicking
this button while capturing.
Default display This button returns the displayed image to the default display size.
Horizontal cursor This button displays the horizontal cursors on the view image area.
Vertical cursor This button displays the vertical cursors on the view image area.
Reference
When the view area is zoomed in, it is possible to pan the field of view by dragging in the image area.
(14)[Close] button
This closes the [View Image] window.
(15)[Help] button
Opens the help menu for TM-Navigator.
"Connecting via USB" (page 1-7) can be established, and then measure
"Connecting via Ethernet" (page 1-9) the measurement target.
"Connecting via USB" (page 1-7)
2 Click
bar.
the [View Image] icon on the tool
"Connecting via Ethernet" (page 1-9)
2 Click
bar.
the [View Image] icon on the tool
Alternative
• Select [View Image] from the [Display] menu.
(6) (7)
When [Re-measure (Ref.Value)] is clicked, reference values are displayed on the right side of the image display screen
(or image storage screen).
(1)
(2)
(3)
(4)
Reference
The following contents will not be reflected in the Re-
measure value.
• Auto-zero
• Average (Always set to 1.)
OK / Cancel
How to Set Re-measure (Ref.Value) Reference value
This section describes how to set the area for "OUT The Re-measure result using the master image is displayed
meas" and "Element". as a reference value according to the setting contents.
For more information on each item, see "TM-3000 Series Clicking [OK] button enables the setting contents
User's Manual". and the Re-measure (Ref.Value) is displayed. If this
is not needed, cancel it.
1 Display the [View Image] window. 6 Click the [Reflect to setting] button on
the [View Image] window.
2 Click the [Start image capturing] button.
Load the image from the controller to display. The contents set for "OUT meas" or "Element" are
reflected in TM Navigator software and not in the
Rotating
When the mouse pointer is placed on the angle with
Circle Line Point
marker after clicking the [Rotation] button, the shape of
the pointer changes to . The area can be rotated by
Moving the angle dragging.
[Rotation] button:
When the mouse pointer is placed on the angle with
marker, the shape of the pointer changes to . It can <Display example>
be moved by dragging.
<Display example>
Reference
• When the following modes are selected, the area can
be rotated.
Moving the side "Line edge" for "Auxil.Meas."
"Arc edge" for "Auxil.Meas."
When the mouse pointer is placed on the side of area, the • Click the [Rotation] button again to move the angle.
shape of the pointer changes to . The shape can be
changed by dragging.
<Display example>
Data Storage
Data storage is a function for storing measurement data in the internal memory of the controller.
Stored data can be displayed on TM-Navigator with a graph and can be transferred to an Excel file.
(6) (9)
(10)
(7) (11)
(8)
This dialog box can be used to configure the controller's data storage settings.
Displays the color used for the graph line. Any color can be set.
Zoom out vertically This button zooms out on the displayed graph in the vertical direction.
Zoom in horizontally This button zooms in on the displayed graph in the horizontal direction.
Zoom out horizontally This button zooms out on the displayed graph in the horizontal direction.
Automatically adjust the This button automatically changes the vertical width of the graph to fill the
vertical scale current size of the [Data storage] window.
This button moves the graph upwards when the data extends beyond the view
Raise display position
graph area.
This button moves the graph downwards when the data extends beyond the
Lower display position
view graph area.
Select cursor A This button allows cursor A to be operated in the view graph area.
Select cursor B This button allows cursor B to be operated in the view graph area.
Select cursor A and This button allows cursor A and cursor B to be manipulated in the view graph
cursor B area simultaneously.
Reverse the
Change the back ground of the view graph area. (The color is reversed in
background and grid
black/white.)
display colors
(14)[Close] button
Closes the [Data storage] window.
(15)[Help] button
Opens the help menu for TM-Navigator.
Displaying the [Data storage] window Changing the data storage settings
Alternative
• Select [Data storage] from the [View] menu.
the controller.
"TM-3000 Series User's Manual"
2 Start or stop data storage according to
"Starting data storage" (page 4-17).
3 Click
bar.
the [Data storage] icon on the tool
3 Click the [Read storage data] button.
The storage data is displayed on TM-Navigator.
The [Data storage] window appears.
(1) (3)
(2)
(4)
(5)
(6) (7)
Image Storage
Image storage is a function for storing the image during measurement in the internal memory of the controller.
Using the TM-Navigator allows the stored data to be checked.
(13)
(14) (15)
(16)
Clears all of the image data that is stored in the internal memory of the controller.
(10)Acquisition Date
Displays the date and time when the image selected for (9) Image No. was stored on the controller.
Default display This button returns the displayed image to the default display size.
Vertical cursor This button displays the vertical cursors on the view image area.
(16)Cursor information
This displays the position information of the cursor displayed in the view image area.
(19)[Close] button
This closes the [Image storage] window.
(20)[Help] button
Opens the help menu for TM-Navigator.
Displaying the [Image storage] window Changing the image storage settings
Alternative
• Select [Image storage] from the [Display] menu.
the controller.
"TM-3000 Series User's Manual"
2 Start or stop data storage according to
"Starting image storage" (page 4-23).
How to Set Re-measure (Ref.Value) 7 Press the "OUT meas" or "Element" tab
to select the available settings for each
This section describes how to set the area for "OUT meas"
item.
and "Element".
For more information on each item, see "TM-3000 Series The master registration image is displayed on the view
User's Manual". image area.
"Help:Ref.Value" (page 4-11)
Displaying the Measurement Data
[Re-measure (Ref.Value)]
Setting Items
Tab
Reference
Tab Setting items Description
page
Head setting Trigger settings Configures the trigger settings that are common for Head A and Head B. 5-3
Head A Sets the measurement conditions for Head A. 5-4
Head B Sets the measurement conditions for Head B. 5-4
Master reg Loads standard images for measurement setting and position correction. 5-6
Pos corr Head A Sets the position correction for the displayed image for Head A. 5-9
Head B Sets the position correction for the displayed image for Head B. 5-9
Measure set Set the inspection and element tools. 5-10
OUT settings Sets the OUT conditions for OUT1 to OUT16. 5-11
Common TIMING terminal Sets TIMING1 /TIMING2 for each OUT setting. 5-16
ZERO terminal Sets ZERO1 /ZERO2 for each OUT setting. 5-16
Binary output Sets binary output for each OUT setting. 5-17
Analog output Sets the analog output conditions separately for CH1 and CH2. 5-17
Storage When storing data in the controller, select either data storage or 5-18
image storage.
Auto-send Sets auto-send for each OUT setting. 5-19
Data out timing Sets the output timing for data. 5-19
Setting list Displays the list of the settings. 5-20
Head Settings
Sets the measurement conditions for Head A and Head B.
For more information about the head settings, see "TM-3000 Series User's Manual".
(4)
(7)
Trigger settings
Setting items Setting range Default value
(1) Trigger mode Cont trigger / External trigger Cont trigger
(2) Int prevention ON / OFF OFF
(3) Trigger rate ON / OFF OFF
Head A / Head B
Setting items Description
(4) View head setting area Displays the setting overview for the head settings.
(5) Paste head settings Pastes the copied head settings into the currently displayed program number.
(6) Copy head settings Copies the currently selected head settings.
The copied head settings can be pasted with [Paste head settings].
(7) Setting window Displays the [Head setting] window and performs advanced settings for the head.
The settings are displayed in (4) [View head setting area].
(4)
Setting Each Function
(5)
(6)
(7)
(8)
(9)
(10)
(3)
(2)
(2) (1)
(3)
Master registration
For more information about the master registration, see "TM-3000 Series User's Manual".
Setting Each Function
(1)
(2)
(7)
(5) (8)
(9)
(1)
(2)
Setting Each Function
(3)
(4)
(5)
(6)
(7)
(8)
* If the correction range exceeds ±20 degrees, [Preview correction] button is not displayed.
Position Correction
For more information about the position correction, see "TM-3000 Series User's Manual".
(2)
(3)
* This is not displayed when the master image has not been registered.
Measurement Settings
For more information about the measurement settings, see "TM-3000 Series User's Manual".
Setting Each Function
(1)
(2)
OUT Settings
For more information about the OUT settings, see "TM-3000 Series User's Manual".
(1)
(3)
(4)
(5)
(6)
Measurement type
The target head and measurement type (mode) set for the measurement settings are displayed.
Clicking [Preview] button displays the master image and measurement area.
Measurement conditions
The measurement conditions can be set in the following range.
Setting Each Function
Scaling
The displayed value for the measurement value can be scaled (calibrated) as desired.
1 When the [Scaling settings] button is clicked, the following setting screen appears.
(1) (3)
(2)
Tolerance settings
The tolerance settings can be set in the following range.
Common Settings
For more information about the common settings, see "TM-3000 Series User's Manual".
TIMING terminal
This setting configures the TIMING terminal.
For details, see "TM-3000 Series User's Manual".
Setting Each Function
ZERO terminal
This setting configures the ZERO terminal.
For details, see "TM-3000 Series User's Manual".
Binary output
This setting configures the binary output.
For details, see "TM-3000 Series User's Manual".
Analog output
This setting configures the analog output.
For details, see "TM-3000 Series User's Manual".
Storage
This setting configures the storage.
For details, see "TM-3000 Series User's Manual".
Setting Each Function
Data Storage
* Sampling is performed once for the entire skipping sample size and the data is stored.
Image storage
Auto-send
This setting configures Auto-send.
For details, see "TM-3000 Series User's Manual".
Setting List
This tab displays a list of the configurations for the settings (head setting, master registration, position correction,
measure set, OUT settings, common settings, environment settings) and the head types.
Setting Each Function
(1)
(2)
Environment Settings
Setting Methods
Click the [Controller environment setting] button in the main window to display the [Controller environment setting]
dialog.
For more information about the environment settings, see "TM-3000 Series User's Manual".
MEMO
Setting Each Function
Appendix
methods and the contents of the error messages.
If the "Cannot connect" warning screen appears when the computer cannot correctly recognize the controller.
Perform the following procedure so that the controller can be recognized correctly.
3 Select the device that is not recognized correctly on the device manager.
Look for a device with the "?" or "!" mark next to the name.
If the controller is not recognized correctly, it appears as one of the following:
If either of these devices is displayed, double-click on the device name. The property window for the selected
device is displayed.
Reference
If there are no device classified as "Unknown device", check for the device under "USB controller".
Appendix
Excel File
This section explains the saved contents when data storage is transferred to Excel.
"Data Storage" (page 4-13)
Appendix
(1) (2)
(1) Measurement date (month/day/year) and time for points 1 to n for each OUT setting (OUT1 to OUT16)
Reference
The data points that are saved in the file are displayed from top to bottom.
(2) Measurement values 1 to n for each OUT setting (OUT1 to OUT16, starting from the left)
Some measurement values may be displayed on Excel as follows.
Measurement
Values on cells
value
------- -1000000
-FFFFFF -1000000
+FFFFFF +1000000
Reference
The data points that are saved in the file are displayed from top to bottom.
Error Messages
This section explains information about the displayed error messages that appear when an error occurs.
Reference
Item Display contents Remedy
page
File operations Failed to read the file ( ). Check whether the selected file is an TM-
Verify that the correct file is set. Navigator program file (*.prs) or an
3-2
* The path name is entered in the environment setting file (*.ens).
parentheses ( ).
Failed to read the environment settings. Check the unreadable environment setting
() items and set correctly on the controller. 3-3
* The failed item is entered in the parentheses ( ).
Master image is short. Change short master This occurs when the master image saved
Appendix
image for non-reg. during program saving does not exist in the
same folder as for the selected file. 5-6
Put the master image (.bmp) in the same
folder.
Sending and Communication failed. Set the controller to "Measurement screen
-
receiving (during measurement)".
settings Transfer setting failed. • Check whether communication is possible
between the controller and computer.
3-4
• Set the controller to "Measurement screen
(during measurement)".
Receive settings failed. • Check whether communication is possible
between the controller and computer.
3-4
• Set the controller to "Measurement screen
(during measurement)".
Head setting Image capture failed. Perform "Trigger input" with the controller to
5-3
capture the image.
The threshold exceeds the setting range. Set Set the threshold within the displayed range.
5-3
the value between 10 and 99.
Master The master image is not registered and Register the master image.
registration cannot be set. Register the master image in 5-6
"Master Image registration".
Correction angle is over the setting range. Set the correction angle to within ±20q. 5-8
Position The correlation value exceeds the setting Set the correlation value within the setting
5-9
correction range. range.
Measurement The master image is not registered and This is displayed when the master image is
setting cannot be set. Register the master image in not registered when "Search" is selected in
5-10
"Master Image registration". "Measurement type".
Register the "Master image".
Reference
Item Display contents Remedy
page
OUT settings OUT name length exceeds the setting range. Set the OUT name to 20 or fewer characters.
Enter a name that is no longer than 20 5-11
characters long.
The value for the alarm error exceeds the Set the value for the alarm error between 0
setting range. and 255. 5-12
Set the value between 0 and 255.
The value for offset exceeds the setting range. Set the offset within the displayed range.
Set the value between ( ) and ( ).
* The values displayed within the parentheses 5-12
( ) vary depending on the units and the
Appendix
minimum display unit.
The Tol upper limit value exceeds the setting range. Set the upper limit within the displayed range.
Set the value between ( ) and ( ).
* The values displayed within the parentheses 5-14
( ) vary depending on the units and the
minimum display unit.
The Tol lower limit value exceeds the setting range. Set the lower limit within the displayed range.
Set the value between ( ) and ( ).
* The values displayed within the parentheses 5-14
( ) vary depending on the units and the
minimum display unit.
The input value exceeds the setting range. Set the input value within the displayed range.
Set the value between ( ) and ( ).
* The values displayed within the parentheses 5-13
( ) vary depending on the units and the
minimum display unit.
The display value exceeds the setting range. Set the display value within the displayed
Set the value between ( ) and ( ). range.
* The values displayed within the parentheses 5-13
( ) vary depending on the units and the
minimum display unit.
Common The measurement value exceeds the setting Set the measurement value within the displayed
settings range. range.
Set the value between ( ) and ( ).
5-17
* The values displayed within the parentheses
( ) vary depending on the units and the
minimum display unit.
The value for output voltage exceeds the Set the value for output voltage between
setting range. -10.500 and 10.500. 5-17
Set the value between -10.500 and 10.500.
Set the span value between -10 and 10. Set the value again to meet the input conditions. -
The same value cannot be set for Set different values for the input values.
5-17
measurement.
The amount of storage data exceeds the setting Set the amount of storage data between 1
range. and 65536. 5-18
Set the value between 1 and 65536.
Reference
Item Display contents Remedy
page
Program name The length of the program name exceeds the Set the program name to 16 or fewer
setting setting range. characters.
2-3
Enter a name that is no longer than 16
characters long.
Environment The IP address exceeds the setting range. Set the IP address to groups of numbers
5-21
settings Set the value between 0 and 255. between 0 and 255.
The subnet mask exceeds the setting range. Set the subnet mask to groups of numbers
5-21
Set the value between 0 and 255. between 0 and 255.
The gateway exceeds the setting range. Set the gateway to groups of numbers
5-21
Appendix
This section provides the TM-Navigator menus and the shortcut keys that can be used.
Appendix
Help(H) View help(H) F1
NOTICE TO USER: PLEASE READ THIS SOFTWARE LICENSE AGREEMENT (""THIS AGREEMENT"") CAREFULLY. BY
USING ALL OR ANY PORTION OF THE TM-Navigator (""THIS SOFTWARE""), YOU ARE AGREEING TO BE BOUND BY
ALL THE TERMS AND CONDITONS OF THIS AGREEMENT. IF YOU DO NOT AGREE TO THE TERMS OF THIS
AGREEMENT, DO NOT USE THIS SOFTWARE.
If you install, copy and or use all or a portion of this Software on a device or computer, you will be deemed to have
agreed to all the terms of this Agreement, and this Agreement will come into effect.
1. Definitions
1.1 "Use" or "using" refers to the accessing, installing, downloading, copying, operating and or otherwise benefiting
from the utilization of this Software.
1.2 "This Software" denotes the software and all associated documentation provided by KEYENCE.
1.3 "User" or "User's" infers the company or persons who have had the license to use this Software granted to them
by KEYENCE.
2. Grant of License.
2.1 In compliance with all of the terms and conditions of this Agreement, KEYENCE grants the nonexclusive and non-
Appendix
Trademarks
• Windows XP/Vista/7/10 are the registered trademarks of Microsoft Corporation, U.S.A.
• Adobe, the Adobe logo, and Reader are the trademarks or registered trademarks of Adobe System Incorporated in
the United States and other countries.
• Other company or product names mentioned in this manual are trademarks or registered trademarks of their
respective companies. The ™ and ® marks are not used in this manual.
Index
B R
Before Installation ............................................. 1-2 Reading and Saving Environment
Setting Files ....................................................... 3-3
Reading and Saving Program Files ................... 3-2
C Reading and Saving Setting Files ..................... 3-2
Common settings ............................................ 5-15 Receiving All Settings ........................................ 3-4
Configuring Communication Settings ........ 1-7, 1-9
Connecting ....................................................... 1-9
Connecting via Ethernet ................................... 1-9 S
Connecting via USB .......................................... 1-7 Sending All Settings .......................................... 3-4
Connection Method .......................................... 1-7 Sending and Receiving Settings ....................... 3-4
Setting items ...................................................... 5-2
Setting List ....................................................... 5-20
Appendix
D Setting Methods .............................................. 5-21
Data Storage ................................................... 4-13 Shortcut Key List ...............................................A-9
Start ................................................................... 1-4
E Starting and Exiting TM-Navigator .................... 1-4
Environment Settings ...................................... 5-21 System Environment .......................................... 1-2
Error Messages ................................................. A-6
Excel File ........................................................... A-5 T
Excel Transfer Contents of Data Storage .......... A-5 Software product license agreement ..............A-10
Exit .................................................................... 1-6
U
F Uninstalling TM-Navigator ................................. 1-3
Functions and Display .............4-2, 4-5, 4-13, 4-19 USB Communication Failure .............................A-2
Functions and Usage of Re-measure
(Ref.Value) ...................................................... 4-10
V
View Image ........................................................ 4-5
H View measurement value .................................. 4-2
Head setting ..................................................... 5-3
Help:Ref.Value ................................................ 4-11
How to Set Re-measure (Ref.Value) ...... 4-11, 4-24
I
Image storage ................................................. 4-19
Inspection Areas ............................................. 4-12
Installing the USB Driver ................................... 1-8
Installing TM-Navigator .............................. 1-2, 1-3
M
Main Window .................................................... 2-2
Measure set .................................................... 5-10
O
OUT Settings ................................................... 5-11
P
Part Names and Functions ............................... 2-2
Position Correction ............................................ 5-9
MEMO
Appendix
MEMO
Appendix
The following terms and conditions will govern KEYENCE products ("Product(s)"). Any terms and conditions in Buyer's
purchase orders or other communications which are contradictory to the terms and conditions herein will be void.
KEYENCE reserves the right to modify the terms and conditions herein from time to time in writing.
KEYENCE CORPORATION
1-3-14, Higashi-Nakajima, Higashi-Yodogawa-ku, Osaka, 533-8555, Japan PHONE: +81-6-6379-2211
*96050E-4*
B5WW1-MAN-1086
Copyright (c) 2010 KEYENCE CORPORATION. All rights reserved. 218001E 1116-4 96050E Printed in Japan