Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Product function
DDSU666 DDSU666-E DDSU666-D DDSU666-F
Voltage input Direct input 0.8Un~1.2Un
Direct input 5(60)A 5(80)A
Current input
Input via CT _ 1.5(6)A
Voltage, current, power,
NO YES
frequency, power factor
Active energy YES
Bidirectional
NO YES
energy measurement
multi-rate(clock) NO YES
Others Demand NO YES
Power pulse YES
IR NO YES
Communication RS485 YES
Single line
Display mode Single line LCD, 7 bit
LCD, 6 bit
Dimension L×W×H(mm) 36×85×66 2 modulus 76×89×74 4 modulus
Technical
Index
parameters
Wiring mode Single phase
Voltage
AC 220V
specification
Specified
0.9Un~1.1Un; the extensional work voltage range:
working voltage
0.8Un~1.2Un
range
Technical parameters Index
voltage Consumption of
Between > 40V and <40V connecting terminals can
the voltage =5VA/1W
AC withstand voltage stand
2kV/5mA/1min AC withstand voltage circuit
Between > 40V and <40V connecting terminals can Resistance >500kΩ
Pulse voltage stand Input via CT/PT: AC1.5(6)A
Rated value
Safety ±4kV 1.2/50μs pulse voltage(10 times/polarity) Direct input: AC5(60)A/AC 5(80)A
Insulation resistance The input, output terminal of the case>100MΩ Input via CT/PT: instant:201max, time of application is 0.5s
Overload
Outage data hold time =10 years Direct input: instant:301max, time of application: half cycle
Input signal Current
Noise immunity of GB/T 17626.2-2006 class 4(contact discharge 8kV, of the rated frequency
electrostatic discharge air discharge 15kV) Consumption of
Noise immunity of RF fields GB/T 17626.3-2006 class 3(10V/m) Current the current =2VA
EFT immunity GB/T 17626.4-2008 class 4(4kV/5kHz) circuit
Surge immunity GB/T 17626.5-2008 class 4(4kV) Resistance <20mΩ
Conduction disturbance
Frequency Input range (50/60±5%)Hz
rejection of radio frequency GB/T 17626.6-2008 class 3(150kHz-80MHz, 10V)
Clock battery capacity =1200mAh
field induction Clock
Electromagnetic Clock accuracy class(daily error) <0.5s/d(23℃)
GB/T17626.12-1998 class 3(common mode 2.5kV,
compatibility Noise immunity of decay wave Display Segment LCD
differential mode 1kV)
Radio interference Voltage Class 0.5; Current Class 0.5; Power factor Class 1;
GB 9254-2008 class B Measurement
suppression Frequency Class 0.5; Active power Class 1; Reactive power Class 1;
parameters and
Specified operating Active energy Class 1;
-10℃~+45℃(3K5grade, indoor use) grade
temperature range
Ultimate operating Support multi-rate measurement of passive, negative total
-25℃~+55℃(3K6grade, indoor use) Multi-rate energy
temperature range active power
Ultimate temperature range Max. demand Support Max. demand record of passive, negative total
-40℃~+70℃(3K8Hgrade, indoor use)
Work environment for storage and transportation record active power, demand interval and slip time can be set
Annual average<75%RH, no dew, no corrosive gas
Relative humidity AC200V AC1.5(6)A 6400imp/kWh
places Pulse constant
AC220V AC5(60)A/AC5(80)A 800imp/kWh
Atmosphere 86kPa~106kPa Energy
Provide 1 set(active energy) optical signal and optocoupler
Pulse signal isolated open collector electrical signal pulse output, pulse
Output
output length:80ms±16ms
External size
Model modulus Support or DL/T645-2007 communication protocol,
(Length× width× height)
customizable MODBUS-RTU communication protocol, the
DDSU666 series 2 36×85×66 RS485
communication baud rate 1200bps,
DDSU666-E series communication
Communication 2400bps,4800bps,9600bps can be set, assumed to be
DDSU666-D series
4 76×89×74 2400bps
DDSU666-F series
D T/S SU666 series
D T/S SU666-D series
7 126×89×66
D T/S SU666-F series
Model
Product function
DDSU666 DDSU666-E DDSU666-D DDSU666-F
Voltage input Direct input 0.8Un~1.2Un
Direct input 5(60)A 5(80)A
Current input
Input via CT _ 1.5(6)A
Voltage, current, power,
NO YES
frequency, power factor
Active energy YES
Bidirectional
NO YES
energy measurement
multi-rate(clock) NO YES
Others Demand NO YES
Power pulse YES
IR NO YES
Communication RS485 YES
Single line
Display mode Single line LCD, 7 bit
LCD, 6 bit
Dimension L×W×H(mm) 36×85×66 2 modulus 76×89×74 4 modulus
Technical
Index
parameters
Wiring mode Single phase
Voltage
AC 220V
specification
Specified
0.9Un~1.1Un; the extensional work voltage range:
working voltage
0.8Un~1.2Un
range
Technical parameters Index
voltage Consumption of
Between > 40V and <40V connecting terminals can
the voltage =5VA/1W
AC withstand voltage stand
2kV/5mA/1min AC withstand voltage circuit
Between > 40V and <40V connecting terminals can Resistance >500kΩ
Pulse voltage stand Input via CT/PT: AC1.5(6)A
Rated value
Safety ±4kV 1.2/50μs pulse voltage(10 times/polarity) Direct input: AC5(60)A/AC 5(80)A
Insulation resistance The input, output terminal of the case>100MΩ Input via CT/PT: instant:201max, time of application is 0.5s
Overload
Outage data hold time =10 years Direct input: instant:301max, time of application: half cycle
Input signal Current
Noise immunity of GB/T 17626.2-2006 class 4(contact discharge 8kV, of the rated frequency
electrostatic discharge air discharge 15kV) Consumption of
Noise immunity of RF fields GB/T 17626.3-2006 class 3(10V/m) Current the current =2VA
EFT immunity GB/T 17626.4-2008 class 4(4kV/5kHz) circuit
Surge immunity GB/T 17626.5-2008 class 4(4kV) Resistance <20mΩ
Conduction disturbance
Frequency Input range (50/60±5%)Hz
rejection of radio frequency GB/T 17626.6-2008 class 3(150kHz-80MHz, 10V)
Clock battery capacity =1200mAh
field induction Clock
Electromagnetic Clock accuracy class(daily error) <0.5s/d(23℃)
GB/T17626.12-1998 class 3(common mode 2.5kV,
compatibility Noise immunity of decay wave Display Segment LCD
differential mode 1kV)
Radio interference Voltage Class 0.5; Current Class 0.5; Power factor Class 1;
GB 9254-2008 class B Measurement
suppression Frequency Class 0.5; Active power Class 1; Reactive power Class 1;
parameters and
Specified operating Active energy Class 1;
-10℃~+45℃(3K5grade, indoor use) grade
temperature range
Ultimate operating Support multi-rate measurement of passive, negative total
-25℃~+55℃(3K6grade, indoor use) Multi-rate energy
temperature range active power
Ultimate temperature range Max. demand Support Max. demand record of passive, negative total
-40℃~+70℃(3K8Hgrade, indoor use)
Work environment for storage and transportation record active power, demand interval and slip time can be set
Annual average<75%RH, no dew, no corrosive gas
Relative humidity AC200V AC1.5(6)A 6400imp/kWh
places Pulse constant
AC220V AC5(60)A/AC5(80)A 800imp/kWh
Atmosphere 86kPa~106kPa Energy
Provide 1 set(active energy) optical signal and optocoupler
Pulse signal isolated open collector electrical signal pulse output, pulse
Output
output length:80ms±16ms
External size
Model modulus Support or DL/T645-2007 communication protocol,
(Length× width× height)
customizable MODBUS-RTU communication protocol, the
DDSU666 series 2 36×85×66 RS485
communication baud rate 1200bps,
DDSU666-E series communication
Communication 2400bps,4800bps,9600bps can be set, assumed to be
DDSU666-D series
4 76×89×74 2400bps
DDSU666-F series
D T/S SU666 series
D T/S SU666-D series
7 126×89×66
D T/S SU666-F series
Model Measurement display T(communication) External size Display
AC AC DC DC RS485 interface mode
voltage current voltage current
PA7777-1 ● @ 96×48
PA7777-2 ● @ 72×72
PA7777-3 ● @ 96×96
Model Measurement display T(communication) K B analog External Display
PA7777-4 ● @ 48×48 3-phase 3-phase RS485 interface Switch quantity size mode
PA7777-5 ● @ 120×60 voltage current quantity output
PA7777-6 ● @ 80×80 output
PA7777-7 ● @ 160×80
PA7777-2S ● @ @ @ 72×72
PA7777-8 ● @ 120×120
PA7777-3S ● @ @ @ 96×96
PZ7777-1 ● @ 96×48
PZ7777-2 ● @ 72×72 PA7777-4S ● 48×48
PZ7777-3 ● @ 96×96 PA7777-6S ● @ @ @ 80×80
PZ7777-4 ● @ 48×48 PA7777-8S ● @ @ @ 120×120 LED
PZ7777-5 ● @ 120×60 display
PZ7777-2S ● @ @ @ 72×72
PZ7777-6 ● @ 80×80
PZ7777-3S ● @ @ @ 96×96
PZ7777-7 ● @ 160×80
LED PZ7777-4S ● 48×48
PZ7777-8 ● @ 120×120
display
PA7777-1D ● @ 96×48 PZ7777-6S ● @ @ @ 80×80
PA7777-2D ● @ 72×72 PZ7777-8S ● @ @ @ 120×120
PA7777-3D ● @ 96×96
PA7777-4D ● @ 48×48
PA7777-5D ● @ 120×60
PA7777-6D ● @ 80×80
PA7777-7D ● @ 160×80
Technical
PA7777-8D ● @ 120×120 index
parameters
PZ7777-1D ● @ 96×48
Accuracy class Class 0.5
PZ7777-2D ● @ 72×72
Rated value AC100V, 450V
PZ7777-3D ● @ 96×96
Overload Continuous: 1.2 times, instant: 2 times/5s
PZ7777-4D ● @ 48×48 Voltage
Consumption ≤1VA(each phase)
PZ7777-5D ● @ 120×60
Resistance 100V(about 120K), 450V(about 600K)
PZ7777-6D ● @ 80×80
PZ7777-7D ● @ 160×80
Input Rated value AC1A, 5A
Current
Overload Continuous: 1.2 times, instant: 10 times/5s Upper/lower-limit alarm with the same relay output,
Consumption ≤1VA
Resistance <20mΩ
Switch quantity output(*) contact capacityAC250V/5A, DC30V/2A, can work in
Output
Measuring range of the frequency 45Hz~65Hz the remote mode
Display mode Single line 4 digit LED display, the max. voltage resolution is 0.1V, the max. current resolution is 0.001A
DC0mA~10mA, DC0mA~20mA, DC4mA~20mA, Class
Polarity indication Complete the positive and negative value switch through polarity light(only for DC meter) Analog quantity output(*)
Mode RS-485 0.5, output overload≤500Ω,customizable voltage output
Commu
Output Protocol MODBUS-RTU
nication Mode RS-485
Baud rate 1200bps, 2400bps, 4800bps, 9600bps, 19200bps, assumed to be 9600bps
Switch quantity output(*) Upper/limit alarm with the same relay output, contact capacityAC250V/5A, DC30V/2A, can work in the remote mode Communication Protocol MODBUS-RTU
Analog quantity output(*) DC0mA~10mA, DC0mA~20mA, DC4mA~20mA, Class 0.5, customizable voltage output (*) 1200bps, 2400bps, 4800bps, 9600bps, 19200bps,
Working power Range AC/DC85V~264V Baud rate
supply Consumption ≤5VA
assumed to be 9600bps
Working power Range AC/DC 85~264V
supply Consumption <5VA
Model Measurement display T(communication) External size Display
AC AC DC DC RS485 interface mode
voltage current voltage current
PA7777-1 ● @ 96×48
PA7777-2 ● @ 72×72
PA7777-3 ● @ 96×96
Model Measurement display T(communication) K B analog External Display
PA7777-4 ● @ 48×48 3-phase 3-phase RS485 interface Switch quantity size mode
PA7777-5 ● @ 120×60 voltage current quantity output
PA7777-6 ● @ 80×80 output
PA7777-7 ● @ 160×80
PA7777-2S ● @ @ @ 72×72
PA7777-8 ● @ 120×120
PA7777-3S ● @ @ @ 96×96
PZ7777-1 ● @ 96×48
PZ7777-2 ● @ 72×72 PA7777-4S ● 48×48
PZ7777-3 ● @ 96×96 PA7777-6S ● @ @ @ 80×80
PZ7777-4 ● @ 48×48 PA7777-8S ● @ @ @ 120×120 LED
PZ7777-5 ● @ 120×60 display
PZ7777-2S ● @ @ @ 72×72
PZ7777-6 ● @ 80×80
PZ7777-3S ● @ @ @ 96×96
PZ7777-7 ● @ 160×80
LED PZ7777-4S ● 48×48
PZ7777-8 ● @ 120×120
display
PA7777-1D ● @ 96×48 PZ7777-6S ● @ @ @ 80×80
PA7777-2D ● @ 72×72 PZ7777-8S ● @ @ @ 120×120
PA7777-3D ● @ 96×96
PA7777-4D ● @ 48×48
PA7777-5D ● @ 120×60
PA7777-6D ● @ 80×80
PA7777-7D ● @ 160×80
Technical
PA7777-8D ● @ 120×120 index
parameters
PZ7777-1D ● @ 96×48
Accuracy class Class 0.5
PZ7777-2D ● @ 72×72
Rated value AC100V, 450V
PZ7777-3D ● @ 96×96
Overload Continuous: 1.2 times, instant: 2 times/5s
PZ7777-4D ● @ 48×48 Voltage
Consumption ≤1VA(each phase)
PZ7777-5D ● @ 120×60
Resistance 100V(about 120K), 450V(about 600K)
PZ7777-6D ● @ 80×80
PZ7777-7D ● @ 160×80
Input Rated value AC1A, 5A
Current
Overload Continuous: 1.2 times, instant: 10 times/5s Upper/lower-limit alarm with the same relay output,
Consumption ≤1VA
Resistance <20mΩ
Switch quantity output(*) contact capacityAC250V/5A, DC30V/2A, can work in
Output
Measuring range of the frequency 45Hz~65Hz the remote mode
Display mode Single line 4 digit LED display, the max. voltage resolution is 0.1V, the max. current resolution is 0.001A
DC0mA~10mA, DC0mA~20mA, DC4mA~20mA, Class
Polarity indication Complete the positive and negative value switch through polarity light(only for DC meter) Analog quantity output(*)
Mode RS-485 0.5, output overload≤500Ω,customizable voltage output
Commu
Output Protocol MODBUS-RTU
nication Mode RS-485
Baud rate 1200bps, 2400bps, 4800bps, 9600bps, 19200bps, assumed to be 9600bps
Switch quantity output(*) Upper/limit alarm with the same relay output, contact capacityAC250V/5A, DC30V/2A, can work in the remote mode Communication Protocol MODBUS-RTU
Analog quantity output(*) DC0mA~10mA, DC0mA~20mA, DC4mA~20mA, Class 0.5, customizable voltage output (*) 1200bps, 2400bps, 4800bps, 9600bps, 19200bps,
Working power Range AC/DC85V~264V Baud rate
supply Consumption ≤5VA
assumed to be 9600bps
Working power Range AC/DC 85~264V
supply Consumption <5VA
Measurement display Energy
Switch
Power RS485 External Display Measurement display Energy
Model Active Reactive Power Active Reactive quantity Analog Switch Switch
voltage current Frequency pulse communication size mode Model Active Reactive Power Active Reactive
Power RS485
quantity quantity quantity
External Display
power power factor energy energy input voltage current Frequency pulse communication size mode
power power factor energy energy output output input
PD7777-2S4 ● ● ● ● ● ● ● ● ● ● ● 72×72
PD7777-13T ● ● ● ● ● ● ● ● ● ● ● 96×48
LCD PD7777-2SK4 ● ● ● ● ● ● ● ● ● ● ● ● 72×72
PD7777-23T ● ● ● ● ● ● ● ● ● ● ● 72×72 PD7777-3S4 ● ● ● ● ● ● ● ● ● ● ● 96×96
display PD7777-3SK4 ● ● ● ● ● ● ● ● ● ● ● ● 96×96
PD7777-33T ● ● ● ● ● ● ● ● ● ● ● 96×96
PD7777-3SB4 ● ● ● ● ● ● ● ● ● ● ● 96×96
PD7777-6S4 ● ● ● ● ● ● ● ● ● ● ● ● 80×80
3 line 4 digit
PD7777-6SK4 ● ● ● ● ● ● ● ● ● ● ● ● 80×80
LED display
PD7777-8S4 ● ● ● ● ● ● ● ● ● ● ● 120×120
PD7777-8SK4 ● ● ● ● ● ● ● ● ● ● ● ● 120×120
PD7777-8SB4 ● ● ● ● ● ● ● ● ● ● ● ● 120×120
Technical
index
parameters
Technical
Connection index
Single phase parameters
mode
Connection
AC220V, AC450V, the other special specifications can Three phase three wire or three phase four wire optional
Rated value mode
be custom-made.
Rated value AC100V, 220V, 450V
Voltage Overload Continuous: 1.2 times, instant: 2 times/5s
Overload Continuous: 1.2 times, instant: 2 times/5s
Consumption ≤2VA Voltage
Consumption ≤2VA(each phase)
Resistance >500kΩ
Input Resistance >500kΩ
Rated value AC5A
Input Rated value AC1A, 5A
Overload Continuous: 1.2 times, instant: 10 times/5s
Current Overload Continuous: 1.2 times, instant: 10 times/5s
Consumption ≤1VA Current
Consumption ≤1VA(each phase)
Resistance <20mΩ
Measuring rang of the frequency 45Hz-65Hz Resistance <20mΩ(each phase)
Voltage Class 0.5 Resolution 0.1V 3 line 4 digit LED or LCD display
Current Class 0.5 Resolution 0.001A Voltage Class 0.5 Resolution 0.1V
Active power Class 0.5 Resolution 1W Current Class 0.5 Resolution 0.001A
Reactive power Class 1.0 Resolution 1var Active power Class 0.5 Resolution 1W
Display mode Reactive power Class 1.0 Resolution 1var
Power factor Class 0.5 Resolution 0.001 Display mode
Measuring accuracy Power factor Class 0.5 Resolution 0.001
Frequency Class 0.5 Resolution 0.01Hz Measuring accuracy
Active energy Class 0.5 Resolution 0.01kWh Frequency Class 0.5 Resolution 0.01Hz
Reactive energy Class 2.0 Resolution 0.01kvarh Active energy Class 0.5 Resolution 0.01kWh
The unit can switch automatically, the decimals shift Reactive energy Class 2.0 Resolution 0.01kvarh
automatically The unit can switch automatically, the decimals shift
Energy Support positive/negative measurement active energy, automatically
measurement four-quadrant measurement reactive energy. Energy Support positive/negative measurement active energy,
Pulse Active power: 10000imp/kWh, Reactive power: measurement four-quadrant measurement reactive energy.
Output
Electric energy constant 10000imp/kvarh Pulse Active power: 10000imp/kWh, Reactive power:
Output
Provide 1 set(active/reactive energy) of optical signal Electric energy constant 10000imp/kvarh
Pulse signal Provide 2 sets(active/reactive energy) of optical signal
and optocoupler isolated open collector electrical signal Pulse signal
output and optocoupler isolated open collector electrical signal
pulse output, pulse length:80ms±16ms output
Mode RS-485 pulse output, pulse length:80ms±16ms
Protocol MODBUS-RTU Mode RS-485
Communication Protocol MODBUS-RTU
1200bps, 2400bps, 4800bps, 9600bps, 19200bps, Communication
Baud rate 1200bps, 2400bps, 4800bps, 9600bps, 19200bps,
assumed to be 9600bps Baud rate
Upper/lower-limit alarm with the same relay output, assumed to be 9600bps
Switch quantity output(*) Support 4-way relay-state output, relay contact
contact capacity:AC250V/5A, DC30V/2A Switch quantity output(*)
Current output: DC0mA~20mA, DC4mA~20mA, Class capacity:AC250V/2A, DC30V/2A(-2,-6 only has 2-way)
Analog quantity output(*) Current output: DC0mA~20mA, DC0mA~20mA,
0.5 Analog quantity output(*)
Switch quantity input 2-way passive dry node input mode DC4mA~20mA, Class 0.5(-2, -6 without this function)
Working power Range AC/DC85V~264V, 50Hz/60Hz 4-way passive dry node input mode(-2,-6 can only be
Switch quantity input
supply Consumption ≤15VA configured 2-way)
Working power Range AC/DC85V~264V
supply Consumption ≤15VA
Measurement display Energy
Switch
Power RS485 External Display Measurement display Energy
Model Active Reactive Power Active Reactive quantity Analog Switch Switch
voltage current Frequency pulse communication size mode Model Active Reactive Power Active Reactive
Power RS485
quantity quantity quantity
External Display
power power factor energy energy input voltage current Frequency pulse communication size mode
power power factor energy energy output output input
PD7777-2S4 ● ● ● ● ● ● ● ● ● ● ● 72×72
PD7777-13T ● ● ● ● ● ● ● ● ● ● ● 96×48
LCD PD7777-2SK4 ● ● ● ● ● ● ● ● ● ● ● ● 72×72
PD7777-23T ● ● ● ● ● ● ● ● ● ● ● 72×72 PD7777-3S4 ● ● ● ● ● ● ● ● ● ● ● 96×96
display PD7777-3SK4 ● ● ● ● ● ● ● ● ● ● ● ● 96×96
PD7777-33T ● ● ● ● ● ● ● ● ● ● ● 96×96
PD7777-3SB4 ● ● ● ● ● ● ● ● ● ● ● 96×96
PD7777-6S4 ● ● ● ● ● ● ● ● ● ● ● ● 80×80
3 line 4 digit
PD7777-6SK4 ● ● ● ● ● ● ● ● ● ● ● ● 80×80
LED display
PD7777-8S4 ● ● ● ● ● ● ● ● ● ● ● 120×120
PD7777-8SK4 ● ● ● ● ● ● ● ● ● ● ● ● 120×120
PD7777-8SB4 ● ● ● ● ● ● ● ● ● ● ● ● 120×120
Technical
index
parameters
Technical
Connection index
Single phase parameters
mode
Connection
AC220V, AC450V, the other special specifications can Three phase three wire or three phase four wire optional
Rated value mode
be custom-made.
Rated value AC100V, 220V, 450V
Voltage Overload Continuous: 1.2 times, instant: 2 times/5s
Overload Continuous: 1.2 times, instant: 2 times/5s
Consumption ≤2VA Voltage
Consumption ≤2VA(each phase)
Resistance >500kΩ
Input Resistance >500kΩ
Rated value AC5A
Input Rated value AC1A, 5A
Overload Continuous: 1.2 times, instant: 10 times/5s
Current Overload Continuous: 1.2 times, instant: 10 times/5s
Consumption ≤1VA Current
Consumption ≤1VA(each phase)
Resistance <20mΩ
Measuring rang of the frequency 45Hz-65Hz Resistance <20mΩ(each phase)
Voltage Class 0.5 Resolution 0.1V 3 line 4 digit LED or LCD display
Current Class 0.5 Resolution 0.001A Voltage Class 0.5 Resolution 0.1V
Active power Class 0.5 Resolution 1W Current Class 0.5 Resolution 0.001A
Reactive power Class 1.0 Resolution 1var Active power Class 0.5 Resolution 1W
Display mode Reactive power Class 1.0 Resolution 1var
Power factor Class 0.5 Resolution 0.001 Display mode
Measuring accuracy Power factor Class 0.5 Resolution 0.001
Frequency Class 0.5 Resolution 0.01Hz Measuring accuracy
Active energy Class 0.5 Resolution 0.01kWh Frequency Class 0.5 Resolution 0.01Hz
Reactive energy Class 2.0 Resolution 0.01kvarh Active energy Class 0.5 Resolution 0.01kWh
The unit can switch automatically, the decimals shift Reactive energy Class 2.0 Resolution 0.01kvarh
automatically The unit can switch automatically, the decimals shift
Energy Support positive/negative measurement active energy, automatically
measurement four-quadrant measurement reactive energy. Energy Support positive/negative measurement active energy,
Pulse Active power: 10000imp/kWh, Reactive power: measurement four-quadrant measurement reactive energy.
Output
Electric energy constant 10000imp/kvarh Pulse Active power: 10000imp/kWh, Reactive power:
Output
Provide 1 set(active/reactive energy) of optical signal Electric energy constant 10000imp/kvarh
Pulse signal Provide 2 sets(active/reactive energy) of optical signal
and optocoupler isolated open collector electrical signal Pulse signal
output and optocoupler isolated open collector electrical signal
pulse output, pulse length:80ms±16ms output
Mode RS-485 pulse output, pulse length:80ms±16ms
Protocol MODBUS-RTU Mode RS-485
Communication Protocol MODBUS-RTU
1200bps, 2400bps, 4800bps, 9600bps, 19200bps, Communication
Baud rate 1200bps, 2400bps, 4800bps, 9600bps, 19200bps,
assumed to be 9600bps Baud rate
Upper/lower-limit alarm with the same relay output, assumed to be 9600bps
Switch quantity output(*) Support 4-way relay-state output, relay contact
contact capacity:AC250V/5A, DC30V/2A Switch quantity output(*)
Current output: DC0mA~20mA, DC4mA~20mA, Class capacity:AC250V/2A, DC30V/2A(-2,-6 only has 2-way)
Analog quantity output(*) Current output: DC0mA~20mA, DC0mA~20mA,
0.5 Analog quantity output(*)
Switch quantity input 2-way passive dry node input mode DC4mA~20mA, Class 0.5(-2, -6 without this function)
Working power Range AC/DC85V~264V, 50Hz/60Hz 4-way passive dry node input mode(-2,-6 can only be
Switch quantity input
supply Consumption ≤15VA configured 2-way)
Working power Range AC/DC85V~264V
supply Consumption ≤15VA
Measurement display Energy
PD7777-2S3 ● ● ● ● ● ● ● ● ● ● ● 72×72
PD7777-2SK3 ● ● ● ● ● ● ● ● ● ● ● ● 72×72
PD7777-3S3 ● ● ● ● ● ● ● ● ● ● ● 96×96
PD7777-3SK3 ● ● ● ● ● ● ● ● ● ● ● ● 96×96
PD7777-3SB3 ● ● ● ● ● ● ● ● ● ● ● 96×96
PD7777-6S3 ● ● ● ● ● ● ● ● ● ● ● ● 80×80
PD7777-6SK3 ● ● ● ● ● ● ● ● ● ● ● ● 80×80 LCD display
PD7777-8S3 ● ● ● ● ● ● ● ● ● ● ● 120×120
PD7777-8SK3 ● ● ● ● ● ● ● ● ● ● ● ● 120×120
PD7777-8SB3 ● ● ● ● ● ● ● ● ● ● ● ● 120×120
E n e rgy S u pp o rt p o sitive /n e ga tive m e a su re m e n t a ctive e ne rg y, Display mode Reactive power Class 0.5 Resolution 1var
m e a su re m e n t fo u r-q u a d ra n t m e a su re m en t re a ctive en e rg y. Measuring accuracy Power factor Class 0.5 Resolution 0.001
M u lti-ra te Frequency Class 0.2 Resolution 0.01Hz
S u pp o rt m u lti-ra te m e a su re m e n t fu n ctio n , m a x. 4 ra te s
e n e rg y(*) Active energy Class 0.2 Resolution 0.01kWh
M a x. d e m a nd S u pp o rt p o sitive , ne g a tive to ta l a ctive /rea ctive m a x. Reactive energy Class 2.0 Resolution 0.01kvarh
E le ctric e ne rg y re co rd (*) d e m a nd re co rd , d em a nd cycle an d slip tim e ca n be se t The unit can switch automatically, the decimals shift automatically
A ctive p ow e r: 1 0 00 0im p /kW h , R ea ctive p ow e r:
O u tp u t P ulse con sta n t
1 0 0 00 im p /kva rh Energy measurement Support positive/negative measurement active(reactive) energy
P ro vid e 2 se ts(a ctive /re a ctive e ne rg y) o f o p tica l sig na l
P ulse sig na l Pulse constant Active power: 10000imp/kWh, Reactive power: 10000imp/kvarh
a n d o p toco up le r isola te d o p e n co lle cto r ele ctrical sig n al
o u tp u t Electric energy Provide 2 sets(active/reactive energy) of optical signal and
p u lse o u tp u t, p u lse le n g th :8 0 m s± 1 6 m s
Pulse signal output
H a rm on ic U h ≥ 3 % U N 5 % U h ; U h < 3 % U N 0 .1 5 % U N Output optocoupler isolated open collector electrical signal pulse output
vo lta ge (T H D u ) Ih ≥ 1 0 % IN ± 5 % Ih ; Ih < 1 0 % IN 0 .1 5 % IN
H a rm on ic(× ) Mode RS-485
H a rm on ic U N is th e n om ina l vo ltag e , IN is th e n o m in al cu rren t, U h
cu rre n t(T H D i) is th e h a rm on ic vo ltag e , Ih is th e h a rm on ic cu rre n t. Communication Protocol MODBUS-RTU
M ode R S -4 8 5
1200bps, 2400bps, 4800bps, 9600bps, 19200bps, assumed to be
P ro to col M O D B U S -R T U Baud rate
C o m m u nica tio n 9600bps
1 2 0 0b p s, 2 40 0 bp s, 4 8 00 bp s, 9 6 0 0b p s, 1 92 0 0b p s,
B a ud ra te Switch quantity input 4-way passive dry node input mode
a ssu m e d to b e 9 60 0 bp s
Support 4-way relay-state output, relay contact capacity:AC250V/2A,
S u pp o rt 4 -w a y re la y-sta te o u tp u t, re la y co n ta ct Switch quantity output
S w itch qu a n tity o u tp u t(*) DC30V/2A(-3H only has 2-way)
ca p a city:A C 25 0V /2 A , D C 3 0 V /2A (-2 ,-6 o nly h as 2 -w a y)
C u rren t o u tp u t: D C 0 m A ~ 10 m A , D C 0 m A ~ 20 m A , Current output: DC0mA~10mA, DC0mA~20mA, DC4mA~20mA,
A n alog q u an tity o u tp u t(*) Analog quantity output
D C 4 m A ~ 2 0 m A , C la ss 0 .5(-2 , -6 w ith o u t th is fu n ction ) Class 0.5(-3H without this function)
4 -w ay p a ssive d ry n o de inp u t m o d e (-2 ,-6 can o nly be Switch quantity input 4-way passive dry node input mode
S w itch qu a n tity in pu t
co n figu re d 2 -w ay) Harmonic 2nd ~31st harmonic of voltage/current
B a tte ry ca pa city o f th e clock ≥200m Ah Calendar clock Clock error: 0.5s/d (reference temperature: 23℃)
C lo ck(× )
A ccu ra cy o f th e clo ck (d aily e rro r) ≤ 0 .5 s/d (2 0℃ ) USB interface Host mode(-3H without this function)
Working power Range AC/DC85V~264V
supply Consumption ≤15VA
Measurement display Energy
PD7777-2S3 ● ● ● ● ● ● ● ● ● ● ● 72×72
PD7777-2SK3 ● ● ● ● ● ● ● ● ● ● ● ● 72×72
PD7777-3S3 ● ● ● ● ● ● ● ● ● ● ● 96×96
PD7777-3SK3 ● ● ● ● ● ● ● ● ● ● ● ● 96×96
PD7777-3SB3 ● ● ● ● ● ● ● ● ● ● ● 96×96
PD7777-6S3 ● ● ● ● ● ● ● ● ● ● ● ● 80×80
PD7777-6SK3 ● ● ● ● ● ● ● ● ● ● ● ● 80×80 LCD display
PD7777-8S3 ● ● ● ● ● ● ● ● ● ● ● 120×120
PD7777-8SK3 ● ● ● ● ● ● ● ● ● ● ● ● 120×120
PD7777-8SB3 ● ● ● ● ● ● ● ● ● ● ● ● 120×120
E n e rgy S u pp o rt p o sitive /n e ga tive m e a su re m e n t a ctive e ne rg y, Display mode Reactive power Class 0.5 Resolution 1var
m e a su re m e n t fo u r-q u a d ra n t m e a su re m en t re a ctive en e rg y. Measuring accuracy Power factor Class 0.5 Resolution 0.001
M u lti-ra te Frequency Class 0.2 Resolution 0.01Hz
S u pp o rt m u lti-ra te m e a su re m e n t fu n ctio n , m a x. 4 ra te s
e n e rg y(*) Active energy Class 0.2 Resolution 0.01kWh
M a x. d e m a nd S u pp o rt p o sitive , ne g a tive to ta l a ctive /rea ctive m a x. Reactive energy Class 2.0 Resolution 0.01kvarh
E le ctric e ne rg y re co rd (*) d e m a nd re co rd , d em a nd cycle an d slip tim e ca n be se t The unit can switch automatically, the decimals shift automatically
A ctive p ow e r: 1 0 00 0im p /kW h , R ea ctive p ow e r:
O u tp u t P ulse con sta n t
1 0 0 00 im p /kva rh Energy measurement Support positive/negative measurement active(reactive) energy
P ro vid e 2 se ts(a ctive /re a ctive e ne rg y) o f o p tica l sig na l
P ulse sig na l Pulse constant Active power: 10000imp/kWh, Reactive power: 10000imp/kvarh
a n d o p toco up le r isola te d o p e n co lle cto r ele ctrical sig n al
o u tp u t Electric energy Provide 2 sets(active/reactive energy) of optical signal and
p u lse o u tp u t, p u lse le n g th :8 0 m s± 1 6 m s
Pulse signal output
H a rm on ic U h ≥ 3 % U N 5 % U h ; U h < 3 % U N 0 .1 5 % U N Output optocoupler isolated open collector electrical signal pulse output
vo lta ge (T H D u ) Ih ≥ 1 0 % IN ± 5 % Ih ; Ih < 1 0 % IN 0 .1 5 % IN
H a rm on ic(× ) Mode RS-485
H a rm on ic U N is th e n om ina l vo ltag e , IN is th e n o m in al cu rren t, U h
cu rre n t(T H D i) is th e h a rm on ic vo ltag e , Ih is th e h a rm on ic cu rre n t. Communication Protocol MODBUS-RTU
M ode R S -4 8 5
1200bps, 2400bps, 4800bps, 9600bps, 19200bps, assumed to be
P ro to col M O D B U S -R T U Baud rate
C o m m u nica tio n 9600bps
1 2 0 0b p s, 2 40 0 bp s, 4 8 00 bp s, 9 6 0 0b p s, 1 92 0 0b p s,
B a ud ra te Switch quantity input 4-way passive dry node input mode
a ssu m e d to b e 9 60 0 bp s
Support 4-way relay-state output, relay contact capacity:AC250V/2A,
S u pp o rt 4 -w a y re la y-sta te o u tp u t, re la y co n ta ct Switch quantity output
S w itch qu a n tity o u tp u t(*) DC30V/2A(-3H only has 2-way)
ca p a city:A C 25 0V /2 A , D C 3 0 V /2A (-2 ,-6 o nly h as 2 -w a y)
C u rren t o u tp u t: D C 0 m A ~ 10 m A , D C 0 m A ~ 20 m A , Current output: DC0mA~10mA, DC0mA~20mA, DC4mA~20mA,
A n alog q u an tity o u tp u t(*) Analog quantity output
D C 4 m A ~ 2 0 m A , C la ss 0 .5(-2 , -6 w ith o u t th is fu n ction ) Class 0.5(-3H without this function)
4 -w ay p a ssive d ry n o de inp u t m o d e (-2 ,-6 can o nly be Switch quantity input 4-way passive dry node input mode
S w itch qu a n tity in pu t
co n figu re d 2 -w ay) Harmonic 2nd ~31st harmonic of voltage/current
B a tte ry ca pa city o f th e clock ≥200m Ah Calendar clock Clock error: 0.5s/d (reference temperature: 23℃)
C lo ck(× )
A ccu ra cy o f th e clo ck (d aily e rro r) ≤ 0 .5 s/d (2 0℃ ) USB interface Host mode(-3H without this function)
Working power Range AC/DC85V~264V
supply Consumption ≤15VA
Measurement display K
T(communication) B analog Measurement display
Model Single phase Three phase three Three phase four
RS485 interface
Switch quantity
quantity output
External size Display mode K B
active power wire active power wire active power output Single
PS7777-1 ● @ @ @ 96×48
3 phase T(communication) Switch analog External Display
Model phase
PS7777-1Y ● @ @ @ 96×48 power RS485 interface quantity quantity size mode
PS7777-1S ● @ @ @ 96×48 power
PS7777-2 ● @ @ @ 72×72
factor output output
factor
PS7777-2S ● @ @ @ 72×72
PS7777-3 ● @ @ @ 96×96 PH7777-1 ● @ @ @ 96×48
PS7777-3Y ● @ @ @ 96×96
PH7777-1S ● @ @ @ 96×48
PS7777-3S ● @ @ @ 96×96
PS7777-5 ● @ @ @ 120×60 PH7777-2 ● @ @ @ 72×72
PS7777-5S ● @ @ @ 120×60
PH7777-2S ● @ @ @ 72×72
PS7777-6 ● @ @ @ 80×80
PS7777-6S ● @ @ @ 80×80 PH7777-3 ● @ @ @ 96×96
PS7777-7 ● @ @ @ 160×80 LED display
PH7777-3S ● @ @ @ 96×96
PS7777-7Y ● @ @ @ 160×80
PS7777-7S ● @ @ @ 160×80 PH7777-5 ● @ @ @ 120×60
PS7777-8 ● @ @ @ 120×120
PH7777-5S ● @ @ @ 120×60
PS7777-8Y ● @ @ @ 120×120
PS7777-8S ● @ @ @ 120×120 PH7777-6 ● @ @ @ 80×80
PH7777-6S ● @ @ @ 80×80
LED
PH7777-7 ● @ @ @ 160×80
display
PH7777-7S ● @ @ @ 160×80
PH7777-8 ● @ @ @ 120×120
PH7777-8S ● @ @ @ 120×120
Technical
index
parameters
Wiring mode Single phase, three phase three wire, three phase four wire
Technical
Rated value AC100V, 220V, 380V index
parameters
Overload Continuous: 1.2 times, instant: 2 times/1s
Accuracy Class 0.5
Voltage Consumption ≤1VA(each phase)
Connection
100V(about 120K), 220V(about 400K), 380V(about Single phase, 3 phase 3 wire, 3 phase 4 wire
Resistance mode
600K)
Input Rated value AC100V±20%, 220V±20%, 380V±20%
Rated value AC1A, 5A
Voltage Overload Continuous: 1.2 times, instant: 2 times/1s
Overload Continuous: 1.2 times, instant: 10 times/5s Input
Current Consumption <1VA
Consumption ≤0.5VA (each phase)
Rated value AC(0~ 5)A
Resistance <20mΩ(each phase)
Current Overload Continuous: 1.2 times, instant: 10 times/5s
Measuring rang of the frequency 45Hz-65Hz
5-digit LED display, reactive power displays “-“ Consumption <0.5VA
Voltage Class 0.5 Resolution 0.1V 4-digit LED display, capacitive(C), inductive(L) can
Display mode
Current Class 0.5 Resolution 0.001A automatically switch through the indicator light.
Display mode Input indication when there is no
Active power Class 0.5 Resolution 1W Input displays the character”----“ when there is no signal.
Measuring accuracy signal
Reactive power Class 1.0 Resolution 1var
The unit can switch automatically, the decimals shift Measuring display range of the
0.000C~0.500C~1.000~0.500L~0.000L
automatically power factor
0~9999MV(Mvar), display “----“ when out of the display
Display range Phase measurement display range 0°~359.9°
range
Technical
index
parameters
Wiring mode Single phase, three phase three wire, three phase four wire
Technical
Rated value AC100V, 220V, 380V index
parameters
Overload Continuous: 1.2 times, instant: 2 times/1s
Accuracy Class 0.5
Voltage Consumption ≤1VA(each phase)
Connection
100V(about 120K), 220V(about 400K), 380V(about Single phase, 3 phase 3 wire, 3 phase 4 wire
Resistance mode
600K)
Input Rated value AC100V±20%, 220V±20%, 380V±20%
Rated value AC1A, 5A
Voltage Overload Continuous: 1.2 times, instant: 2 times/1s
Overload Continuous: 1.2 times, instant: 10 times/5s Input
Current Consumption <1VA
Consumption ≤0.5VA (each phase)
Rated value AC(0~ 5)A
Resistance <20mΩ(each phase)
Current Overload Continuous: 1.2 times, instant: 10 times/5s
Measuring rang of the frequency 45Hz-65Hz
5-digit LED display, reactive power displays “-“ Consumption <0.5VA
Voltage Class 0.5 Resolution 0.1V 4-digit LED display, capacitive(C), inductive(L) can
Display mode
Current Class 0.5 Resolution 0.001A automatically switch through the indicator light.
Display mode Input indication when there is no
Active power Class 0.5 Resolution 1W Input displays the character”----“ when there is no signal.
Measuring accuracy signal
Reactive power Class 1.0 Resolution 1var
The unit can switch automatically, the decimals shift Measuring display range of the
0.000C~0.500C~1.000~0.500L~0.000L
automatically power factor
0~9999MV(Mvar), display “----“ when out of the display
Display range Phase measurement display range 0°~359.9°
range
PP7777-1 ● @ @ @ 96×48
PP7777-2 ● @ @ @ 72×72
PP7777-3 ● @ @ @ 96×96 Technical
index
parameters
PP7777-4 ● @ @ @ 48×48
Input range 0~1500V
PP7777-5 ● @ @ @ 120×60 DC voltage
LED Input resistance >5MΩ
PP7777-6 ● @ @ @ 80×80
display 0~9999A (external shunts or hall devices are needed; the
PP7777-7 ● @ @ @ 160×80 Input range
range can be programmable set.
PP7777-8 ● @ @ @ 120×120 Shunt Supporting output is 0~75mV
DC current Hall device Supporting output is 0~20mA, 4~20mA, 0~4V, 0~5V, etc.
Number of
Max. 12 ways(iDE2000 is 16 ways
Input ways
Consumption ≤1mW
Measuring rang of the
-40℃~120℃
temperature(×)
Measuring range of the
0%~100%
humidity(×)
Technical Continuously normal work for 1.2 times, continue 1s for
Index Overload
1.5 times
parameters
Accuracy Class 0.5 Display mode 3.5 inch color liquid crystal
Connection
Single phase
mode Voltage Class 0.2
Input Rated value AC100V~AC500V Current Class 0.2
Voltage Overload Continuous: 1.2 times, instant: 2 times/1s Power Class 0.5
Measuring accuracy
Consumption <1VA Energy Class 0.5
Temperature 0.2℃
4-digit LED display
Display mode Humidity 3%
Input displays the character”----“when there is no signal.
Measuring display range of the Current fluctuation unbalance protection fixed value error:
30.00Hz~70.00Hz ±2%
frequency Protection action error
Higher harmonic containing rate fixed value error: ±2%
(only for iDE3000)
Mode RS-485 Reverse current protection fixed value error: ±0.5%
Motion time error: ±0.1s
Communication Protocol MODBUS-RTU
Output Mode RS-485
1200bps, 2400bps, 4800bps, 9600bps, 19200bps,
Baud rate Output
assumed to be 9600bps
Communication Protocol MODBUS-RTU
Upper/lower limit alarm with the same one relay output, 1200bps, 2400bps, 4800bps, 9600bps, 19200bps,
Switch quantity output Baud rate
contact capacity:AC250V/2A, DC30V/2A assumed to be 9600bps
DC0mA~10mA, DC0mA~20mA, DC4mA~20mA, Class 13-way passive dry node input(iDE2000 is configured
Input(DI)
16-way)
Analog quantity output 0.5, output overload≤500Ω, the voltage output can be Switch quantity
14-way relay output, AC277V/5A or DC30V/5A(iDE2000 is
custom-made Output(DO)
configured 2-way)
Working Range AC/DC85V~264V
Can save and display one month voltage, current,
power supply Consumption <5VA humidity, temperature, degree of unbalancedness of
current, max. value、min. value、average value of the
History curve
higher harmonic, history curve of 95% max. probability
value(Ide2000 without degree of unbalancedness of
current, higher harmonic)
Can view on site or communication read recent switch
SOE quantity input, switch quantity output each 4000 SOE
records.
Clock Battery capacity ≤200mAh
iDE - □
PP7777-1 ● @ @ @ 96×48
PP7777-2 ● @ @ @ 72×72
PP7777-3 ● @ @ @ 96×96 Technical
index
parameters
PP7777-4 ● @ @ @ 48×48
Input range 0~1500V
PP7777-5 ● @ @ @ 120×60 DC voltage
LED Input resistance >5MΩ
PP7777-6 ● @ @ @ 80×80
display 0~9999A (external shunts or hall devices are needed; the
PP7777-7 ● @ @ @ 160×80 Input range
range can be programmable set.
PP7777-8 ● @ @ @ 120×120 Shunt Supporting output is 0~75mV
DC current Hall device Supporting output is 0~20mA, 4~20mA, 0~4V, 0~5V, etc.
Number of
Max. 12 ways(iDE2000 is 16 ways
Input ways
Consumption ≤1mW
Measuring rang of the
-40℃~120℃
temperature(×)
Measuring range of the
0%~100%
humidity(×)
Technical Continuously normal work for 1.2 times, continue 1s for
Index Overload
1.5 times
parameters
Accuracy Class 0.5 Display mode 3.5 inch color liquid crystal
Connection
Single phase
mode Voltage Class 0.2
Input Rated value AC100V~AC500V Current Class 0.2
Voltage Overload Continuous: 1.2 times, instant: 2 times/1s Power Class 0.5
Measuring accuracy
Consumption <1VA Energy Class 0.5
Temperature 0.2℃
4-digit LED display
Display mode Humidity 3%
Input displays the character”----“when there is no signal.
Measuring display range of the Current fluctuation unbalance protection fixed value error:
30.00Hz~70.00Hz ±2%
frequency Protection action error
Higher harmonic containing rate fixed value error: ±2%
(only for iDE3000)
Mode RS-485 Reverse current protection fixed value error: ±0.5%
Motion time error: ±0.1s
Communication Protocol MODBUS-RTU
Output Mode RS-485
1200bps, 2400bps, 4800bps, 9600bps, 19200bps,
Baud rate Output
assumed to be 9600bps
Communication Protocol MODBUS-RTU
Upper/lower limit alarm with the same one relay output, 1200bps, 2400bps, 4800bps, 9600bps, 19200bps,
Switch quantity output Baud rate
contact capacity:AC250V/2A, DC30V/2A assumed to be 9600bps
DC0mA~10mA, DC0mA~20mA, DC4mA~20mA, Class 13-way passive dry node input(iDE2000 is configured
Input(DI)
16-way)
Analog quantity output 0.5, output overload≤500Ω, the voltage output can be Switch quantity
14-way relay output, AC277V/5A or DC30V/5A(iDE2000 is
custom-made Output(DO)
configured 2-way)
Working Range AC/DC85V~264V
Can save and display one month voltage, current,
power supply Consumption <5VA humidity, temperature, degree of unbalancedness of
current, max. value、min. value、average value of the
History curve
higher harmonic, history curve of 95% max. probability
value(Ide2000 without degree of unbalancedness of
current, higher harmonic)
Can view on site or communication read recent switch
SOE quantity input, switch quantity output each 4000 SOE
records.
Clock Battery capacity ≤200mAh
T □ □–2□0□ □
E 0~+800℃
Cu50 0~50℃, 0~100℃, 0~150℃
Hot resistance (RTD) K 0~+1300℃
Pt100 0~200℃, 0~300℃, 0~400℃ Thermocouple (TC)
J 0~+1000℃
S 0~+1750℃
Cu50 -50~+150℃
Hot resistance (RTD)
Pt100 -200~+800℃
Item Type index
Basic error ≤±2.5%F·S
Set point error ≤±1.5%F·S
Switch difference ≤0.75%F·S
Cold end compensation The error is less than 2℃ within the range 0℃~40℃ Item Type index
Time scale adjustment Proportional band 4%, null cycle 30s±10s Display mode LED display
Output relay contact capacity AC240V, 5A (resistance) Basic error ≤±1.0%F·S±1 word
Work power supply 220V±10%, 50Hz, consumption<3VA Resolution 1℃ or 0.1℃
Work environment Temperature 0℃~50℃, the relative humidity no more than 85% Control sensitivity ≤±0.75%F·S
non-corrosiveness places Cold end compensation The error is less than 2℃ within the range 0℃~40℃
weight ≤0.8kg Sampling cycle of the meter 3 times/s
Output relay contact capacity Relay contact 220V resistance load≤3A;
relay contact 220V conductive load≤1A
Work environment Temperature 0℃~50℃, the relative humidity no more than 85%
non-corrosiveness places
Model Panel size Shell size Cutting size
weight ≤0.8kg
E 0~+800℃
Cu50 0~50℃, 0~100℃, 0~150℃
Hot resistance (RTD) K 0~+1300℃
Pt100 0~200℃, 0~300℃, 0~400℃ Thermocouple (TC)
J 0~+1000℃
S 0~+1750℃
Cu50 -50~+150℃
Hot resistance (RTD)
Pt100 -200~+800℃
Item Type index
Basic error ≤±2.5%F·S
Set point error ≤±1.5%F·S
Switch difference ≤0.75%F·S
Cold end compensation The error is less than 2℃ within the range 0℃~40℃ Item Type index
Time scale adjustment Proportional band 4%, null cycle 30s±10s Display mode LED display
Output relay contact capacity AC240V, 5A (resistance) Basic error ≤±1.0%F·S±1 word
Work power supply 220V±10%, 50Hz, consumption<3VA Resolution 1℃ or 0.1℃
Work environment Temperature 0℃~50℃, the relative humidity no more than 85% Control sensitivity ≤±0.75%F·S
non-corrosiveness places Cold end compensation The error is less than 2℃ within the range 0℃~40℃
weight ≤0.8kg Sampling cycle of the meter 3 times/s
Output relay contact capacity Relay contact 220V resistance load≤3A;
relay contact 220V conductive load≤1A
Work environment Temperature 0℃~50℃, the relative humidity no more than 85%
non-corrosiveness places
Model Panel size Shell size Cutting size
weight ≤0.8kg
Input type Graduation Measuring range Input type Graduation Measuring range
K -50℃~+1350℃ 0~20mV
S -50℃~+1750℃ 0~60mV
R -50℃~+1750℃ 0~100mV
DC voltage(U)
T -200℃~+400℃ 0~1V
Thermocouple (TC)
E -50℃~+800℃ 0~5V Name Model Graduation
-1999~+9999
J -50℃~+1000℃ 1~5V
User-defined Compression spring type WRET-01 E(EA-2)
B 0℃~+1800℃ 0~10mA
Thermocouple WRKT-01 K(Eu-2)
N -50℃~+1300℃ DC current(I) 0~20mA
WRe3-WRe25 0℃~+2300℃ 4~20mA Screw type WRET-02 E(EA-2)
Cu50 -50℃~+150℃ Thermocouple WRKT-02 K(Eu-2)
Hot resistance (RTD) Resistance(R) 30~350Ω
Pt100 -200℃~+850℃
Probe type WRET-03 E(EA-2)
Thermocouple WRKT-03 K(Eu-2)
Input type Graduation Measuring range Input type Graduation Measuring range
K -50℃~+1350℃ 0~20mV
S -50℃~+1750℃ 0~60mV
R -50℃~+1750℃ 0~100mV
DC voltage(U)
T -200℃~+400℃ 0~1V
Thermocouple (TC)
E -50℃~+800℃ 0~5V Name Model Graduation
-1999~+9999
J -50℃~+1000℃ 1~5V
User-defined Compression spring type WRET-01 E(EA-2)
B 0℃~+1800℃ 0~10mA
Thermocouple WRKT-01 K(Eu-2)
N -50℃~+1300℃ DC current(I) 0~20mA
WRe3-WRe25 0℃~+2300℃ 4~20mA Screw type WRET-02 E(EA-2)
Cu50 -50℃~+150℃ Thermocouple WRKT-02 K(Eu-2)
Hot resistance (RTD) Resistance(R) 30~350Ω
Pt100 -200℃~+850℃
Probe type WRET-03 E(EA-2)
Thermocouple WRKT-03 K(Eu-2)