FCV7-10 - Flow Restrictor Valve

Needle
Up to 45 L/min (12 USgpm) • 210 bar (3000 psi)

Operation Features
This needle valve is a variable to completely closed and anti- Hardened and ground working
1 2 orifice used to create a pressure clockwise increases the orifice. components. Cartridge
drop when flow passes from The setting can be locked using construction for maximum
port 1 to 2 or port 2 to 1. the lock nut on the adjust screw mounting flexibility.
Clockwise rotation of the adjust
screw de-creases the orifice size

1 2
Performance Data

Ratings and Specifications


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Sectional View Typical application pressure (all ports) 210 bar (3000 psi)
Rated flow 45 L/min (12 USgpm)
Temperature range -40° to 120°C (-40° to 248°F)
Cavity C–10–2
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration ISO 4406, class 18/16/13 or cleaner
Standard housing materials Aluminum
Weight cartridge only 0,11 kg (0.25 lbs.)
Flow - L/min (21,8 cSt oil @ 49°C)
Seal kits 565806 Buna N
2 2 4,8 14,4 24,0 33,6 889627
43,2 Viton®
9,6 19,2 28,8 38,4 48,0
Viton is a registered trademark of E.I. DuPont
3000 200
"FF" 1 "10,20,40" 1 "NV" A B C D E
Pressure drop - psi

Pressure drop - bar


2400 160
"NVF" 1800
F
120
Pressure Drop
H Cartridge only
1200
G
80
600 40
0 0
Description
Flow - L/min (21,8 cSt oil @ 49°C)
This is a manually adjusted 4,8 14,4 24,0 33,6 43,2 300 20
cartridge type needle valve. With 9,6 19,2 28,8 38,4 48,0 H
Pressure drop - psi

Pressure drop - bar


fine control it is ideal for none 3000 200 240 16
A B C D E I
Pressure drop - psi

compensated speed control of


Pressure drop - bar

2400 160 180 12


actuators or as a control orifice 1800
F
120 120 J
8
in conjunction with a pressure
compensator Total shut off can 1200 80 60 4
G
be achieved allowing the valve to 600 40 0 0
be used as a shut of valve. 0 0
0 2 4 6 8 10 12
Flow - USgpm (105 SUS oil @ 120°F)

300 20
Typical
240 Flow Regulation (full open)
H
Pressure drop - psi

Pressure drop - bar

16
I
180 Flow 12 Flow
Code Direction J Valve Code Direction Valve
120 Option*
Curve Port: 8
Condition Curve Option Port Condition

60 4
A
0 10 2 to 1 Open F 20 1 to 2 Open
0 2 4 1 to 6 2 8 10 Closed 0
12
B Flow
20 - USgpm 2(105
to 1 Open
SUS oil @ 120°F) G 40 1 to 2 Open
1 to 2 Closed
C 10 1 to 2 Open H FF 2 to 1 Open
D 40 2 to 1 Open I FF 1 to 2 Open &
1 to 2 Closed Closed
E NVF Both directions Open J NV Both directions Open
*See controlled flow option in model code.

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-380.A EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009 An Eaton Brand
FCV7-10 - Flow Restrictor Valve
Needle
Up to 45 L/min (12 USgpm) • 210 bar (3000 psi)

Model Code FCV7 – 10 (V) – * – ** – *** – 00

1 2 3 4 5 6 7

1 Function 5 Port Size 7 Special Features


FCV7 – Flow regulator Code Port Size Housing Number 00 - None
Aluminium Aluminium (Only required if valve has special
2 Size Light duty Fatigue rated features, omit if ("00")
10 - 10 size 3B 3/8” BSPP 02–175462 –
6T SAE 6 566151 –
3 Seal Material 2G 1/4” BSPP – 876702
3G 3/8” BSPP – 876703
Blank - Buna-N
V- Viton® 6H SAE 6 – 8767008H
8H SAE 8 – 876701
4 Style See section J for housing details.
C - Cap
K - Knob 6 Controlled Flow Option
Maximum Flow Range (nominal)
S - Screw
NV Needle valve 0-45 L/min (0-12 USgpm)
NVF Needle valve, fine 0-38 L/min (0-10 USgpm)
FF Needle valve with free reverse flow 0-45 L/min (0-12 USgpm)
10 Flow range, type 10, with free reverse flow 0-6,6 L/min (0-1.75 USgpm)
20 Flow range, type 20, with free reverse flow 0-14 L/min (0-3.75 USgpm)
40 Flow range, type 40, with free reverse flow 0-27 L/min (0-7.25 USgpm)

Dimensions Torque cartridge in H


mm (inch) aluminum housing to
47–54 Nm (35–40 ft.lbs)
Cartridge Only
Basic Code FCV7-10

"K" Adjustment "C" Adjustment


Ø38,1
(1.50)

5,1 (0.20) max. travel 44


(1.73) "S" Adjustment
4,8 (0.18) hex
30,2 19,1 (0.75) hex
(1.18)
25,4 (1.00) hex

0.875"-14 Thd.
31,7
(1.25)
2

1
Ø15,82 (0.623)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

An Eaton Brand EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009 H-381.A