Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Bus Number Bus Name Id Area Num Area Name Zone Num Zone Name Code In Service
101 NUC-A 21.600 1 1 FLAPCO 77 PLANT 2 1
102 NUC-B 21.600 1 1 FLAPCO 77 PLANT 2 1
201 HYDRO 500.00 1 2 LIGHTCO 2 SECOND -2 1
206 URBGEN 18.000 1 2 LIGHTCO 2 SECOND -2 1
3001 MINE 230.00 1 5 WORLD 5 FIFTH 3 1
3008 CATDOG 230.00 1 5 WORLD 5 FIFTH -2 1
1
OPTIMIZED LF CASE
Bus Number Bus Name Id Area Num Area Name Zone Num Zone Name Code In Service
101 NUC-A 21.600 1 1 FLAPCO 77 PLANT 2 1
102 NUC-B 21.600 1 1 FLAPCO 77 PLANT 2 1
201 HYDRO 500.00 1 2 LIGHTCO 2 SECOND 2 1
206 URBGEN 18.000 1 2 LIGHTCO 2 SECOND 2 1
3001 MINE 230.00 1 5 WORLD 5 FIFTH 3 1
3008 CATDOG 230.00 1 5 WORLD 5 FIFTH 2 1
1
F CASE
PGen (MW) QMax (Mvar) QMin (Mvar) QGen (Mvar)
750 600 -100 151.1125
750 600 -100 151.1125
600 400 -100 400
800 600 0 600
247.7071 600 -100 187.2455
100 80 0 80
LF CASE
PGen (MW) QMax (Mvar) QMin (Mvar) QGen (Mvar)
750 600 -100 228.0047
750 600 -100 228.0047
600 400 -100 181.6299
800 600 0 325.517
244.0162 600 -100 218.9386
100 80 0 43.7169
ORIGINAL LF CASE
Bus NumbBus NameId Area Num Area NamZone NumZone Nam Code In Service PGen (MW
101 NUC-A 1 1 FLAPCO 77 PLANT 2 1 750
102 NUC-B 1 1 FLAPCO 77 PLANT 2 1 750
201 HYDRO 1 2 LIGHTCO 2 SECOND -2 1 600
206 URBGEN 1 2 LIGHTCO 2 SECOND -2 1 800
3001 MINE 1 5 WORLD 5 FIFTH 3 1 248.8805
3008 CATDOG 1 5 WORLD 5 FIFTH -2 1 100
1
OPTIMIZED LF CASE
Bus NumbBus NameId Area Num Area NamZone NumZone Nam Code In Service PGen (MW
101 NUC-A 1 1 FLAPCO 77 PLANT 2 1 750
102 NUC-B 1 1 FLAPCO 77 PLANT 2 1 750
201 HYDRO 1 2 LIGHTCO 2 SECOND 2 1 600
206 URBGEN 1 2 LIGHTCO 2 SECOND 2 1 800
3001 MINE 1 5 WORLD 5 FIFTH 3 1 226.0769
3008 CATDOG 1 5 WORLD 5 FIFTH 2 1 100
1
QMax (MvaQMin (MvaVSched (puQGen (Mvar)
600 -100 1.02 151.1125
600 -100 1.02 151.1125
400 -100 1.05 400
600 0 0.98 600
600 -100 1.05 187.2455
80 0 1.02 80
OPTIMIZED LF CASE
Bus NumbBus NameId Area Num Area NamZone NumZone Nam Code In Service PGen (MW
101 NUC-A 1 1 FLAPCO 77 PLANT 2 1 750
102 NUC-B 1 1 FLAPCO 77 PLANT 2 1 750
201 HYDRO 1 2 LIGHTCO 2 SECOND 2 1 600
206 URBGEN 1 2 LIGHTCO 2 SECOND 2 1 800
3001 MINE 1 5 WORLD 5 FIFTH 3 1 242.9699
3008 CATDOG 1 5 WORLD 5 FIFTH 2 1 100
1
QMax (MvaQMin (MvaVSched (puQGen (Mvar)
600 -100 1.02 151.1125
600 -100 1.02 151.1125
400 -100 1.05 400
600 0 0.98 600
600 -100 1.05 187.2455
80 0 1.02 80
XAMPLE 4
QMax (MvaQMin (MvaVSched (pu) QGen (Mvar) VSched (pu) QGen (Mvar) Voltage (pu) - regualted BUS
600 -100 1.02 151.1125 1.02 126.0585 1.0369
600 -100 1.02 151.1125 1.02 126.0585 1.0369
400 -100 1.05 400 1.05 398.5725 1.0381
600 0 0.98 600 0.9612 599.391 0.9612
600 -100 1.05 187.2455 1.05 112.2812 1.0498
80 0 1.02 80 1.02 78.8911 0.9753
egualted BUS
OPTIMIZED LF CASE - EXAMPLE 4
Bus NumbBus NameId Area Num Area NamZone NumZone Nam Code In Service PGen (MW
101 NUC-A 1 1 FLAPCO 77 PLANT 2 1 750
102 NUC-B 1 1 FLAPCO 77 PLANT 2 1 750
201 HYDRO 1 2 LIGHTCO 2 SECOND -2 1 600
206 URBGEN 1 2 LIGHTCO 2 SECOND -2 1 800
3001 MINE 1 5 WORLD 5 FIFTH 3 1 248.8805
3008 CATDOG 1 5 WORLD 5 FIFTH -2 1 100
1
5 (CLAMP)
OPTIMIZED LF CASE - EXAMPLE 7B (dual convergence criteria)
Bus NumbBus NameId Area Num Area NamZone NumZone Nam Code In Service PGen (MW
101 NUC-A 1 1 FLAPCO 77 PLANT 2 1 750
102 NUC-B 1 1 FLAPCO 77 PLANT 2 1 750
201 HYDRO 1 2 LIGHTCO 2 SECOND 2 1 600
206 URBGEN 1 2 LIGHTCO 2 SECOND 2 1 800
3001 MINE 1 5 WORLD 5 FIFTH 3 1 245.72
3008 CATDOG 1 5 WORLD 5 FIFTH 2 1 100
1
OPTIMIZED LF CASE - EXAMPLE 8A (High Cost)
MPLE 8
A (High Cost)
ORIGINAL LF CASE - EXAMPLE 9
PLE 9
Adjustment change)
Bus NumbBus NameId Area Num Area NamZone NumZone Nam Code In Service PGen (MW)
1 SWING 1 1 1 3 1 50.0016
2 GEN 2 1 1 1 2 1 87.8859
3 GEN 3 1 1 1 2 1 78.7906
1
th Flow Constraint)
Original LF CASE - EXAMPLE 11A
OPTIMIZED LF CASE - EXAMPLE 11B (Constrained FLOW AREA 5-1 w/o Loss O
OPTIMIZED LF CASE - EXAMPLE 11C (Constrained FLOW AREA 5-1 with Loss O
OPTIMIZED LF CASE - EXAMPLE 11D (Constrained FLOW (-cost) AREA 5-1 with Lo
11A
Bus NumbBus NameId Area Num Area NamZone NumZone Nam Code In Service PGen (MW
101 NUC-A 1 1 FLAPCO 77 PLANT 2 1 750
102 NUC-B 1 1 FLAPCO 77 PLANT 2 1 750
201 HYDRO 1 2 LIGHTCO 2 SECOND 2 1 600
206 URBGEN 1 2 LIGHTCO 2 SECOND 2 1 800
3001 MINE 1 5 WORLD 5 FIFTH 3 1 226.4033
3008 CATDOG 1 5 WORLD 5 FIFTH 2 1 100
1
OPTIMIZED LF CASE - EXAMPLE 12A (Vlimit 1.05-0.95)
Bus NumbBus NameId Area Num Area NamZone NumZone Nam Code In Service PGen (MW
101 NUC-A 1 1 FLAPCO 77 PLANT 2 1 750
102 NUC-B 1 1 FLAPCO 77 PLANT 2 1 750
201 HYDRO 1 2 LIGHTCO 2 SECOND 2 1 600
206 URBGEN 1 2 LIGHTCO 2 SECOND 2 1 800
3001 MINE 1 5 WORLD 5 FIFTH 3 1 243.2998
3008 CATDOG 1 5 WORLD 5 FIFTH 2 1 100
1
OPTIMIZED LF CASE - EXAMPLE 12B (shunt VS Gen limit)
EXAMPLE 12
OPT 391
delta 1178
if add 791 capacitor
ORIG 1569
OPTIMIZED LF CASE - EXAMPLE 13
PLE 13