PISTON PUMP

FAILURE ANALYSIS
A Guide to Analyzing Axial
Piston Pump Failures

1 2 Power
Innovative Fluid

CONTAMINATION
TYPICAL FAILURE MODES
l PISTON SEIZED IN BORE, PULLS SHOE OFF.

l PISTONS SHOW FINE SCRATCHES,DULL FINISH.


• Contamination
l EXCESSIVE WEAR ON SWASHBLOCK FACE,
• Fluid Issue SHOE FACE AND VALVE PLATE FACE.
• Over Pressurization
l EXCESSIVE WEAR ON SADDLE BEARINGS.
• Improper Inlet Condition
l HYDRO-DYNAMIC BEARING WORN.
• Case To Inlet Differential
• Miscellaneous l CONTROL UNSTABLE: PISTON STICKING,
COMPENSATOR SPOOL STUCK OR WORN,
ORIFICE IN CONTROL PISTON PLUGGED.
3 Power
Innovative Fluid 4 Power
Innovative Fluid

1
CONTAMINATION EXAMPLES A Clear Indication of Contamination

Vertical scratches on the


piston barrel.

Note Metal Transfer

5 Power
Innovative Fluid 6 Power
Innovative Fluid

SHOE WEAR PLATE SHOWING


Dull and scratchy finish SIGNS OF WEAR DUE TO DIRT

Normal Appearance:
A Mirror Finish
Scratchy Uneven
Wear
Abnormal Appearance:
A Steel Wool Look

7 Power
Innovative Fluid 8 Power
Innovative Fluid

2
VALVE PLATE RUN ON A BAD
FLUID ISSUE
FLUID
Viscosity too Low, Operating Temperature too High,
Not a Hydraulic Fluid, Fluid Breaking Down

l PISTON SEIZED IN BORE, PULLS PISTON SHOE


l SHOE FACES AND OR VALVE PLATE FACE
SMEARED Note the
l BALL WORN THROUGH SHOE RETAINER Smeared
l SHAFT SEAL LEAKS Running
l CAVITATION, AIR ENTRAINMENT Surface
l EXCESSIVE SADDLE BEARING WEAR

9 Power
Innovative Fluid 10 Power
Innovative Fluid

WORN FULCRUM BALL WORN SADDLE BEARING


Typical Failure on
Low Lubricity
Fluid
The fulcrum ball
is between the
rotating group and
the shoe retainer
plate. Note the material has delaminated

11 Power
Innovative Fluid 12 Power
Innovative Fluid

3
OVER PRESSURIZATION/SPIKES EXCESSIVEWEAR ON CYLINDER
Spike Relief Always Recommended FACE
l Excessive swashblock face, cylinder to valve plate wear
l Pistons broken at necks
l Broken shaft where cylinder rides
l Broken tail shaft (dual)
l Control pin broken Cracks
l Cylinder cracked between kidneys Would
Appear
l Control O-ring, gasket failure (PVW) Between
Kidneys
13 Power
Innovative Fluid 14 Power
Innovative Fluid

TORSIONAL FATIGUE: BENDING FATIGUE FAILURE


Note Cone Shaped Failure Note Straight Break

15 Power
Innovative Fluid 16 Power
Innovative Fluid

4
CAVITATION ON COMPRESSION
IMPROPER INLET CONDITIONS BRIDGE

What are the improper inlet conditions for piston pumps?

l CAVITATION ON VALVE PLATE FACE


l NOISE (MARBLE SOUND)

17 Power
Innovative Fluid 18 Power
Innovative Fluid

DIFFERENTIAL CANNOT
CASE TO INLET DIFFERENTIAL EXCEED 10 PSI
Case to inlet differential refers to the pressure difference
between the inlet pressure (vacuum) and the case drain Examples of high case pressure differential:
pressure.
l SHOE EDGES ROUNDED
The pressure in the case has to be vented back to the reservoir
l SHOES LOOSE ON BALLS
below fluid level. As the pump creates flow the inefficiencies
are drained into the case. If the case drain line or fittings are l SWASHBLOCK WEAR, HALF MOON SHAPE
undersized this will cause the case pressure to increase.
l EXCESSIVE WEAR ON BACK OF SHOE
FLANGES
l SEAL RETAINER BENT

19 Power
Innovative Fluid 20 Power
Innovative Fluid

5
STAGES OF DAMAGE DUE TO
SHOE LOOSE ON BALL SHOE LIFT

This is an example of a
shoe that became loose
on the ball and with
repeated high case
pressure fatigued the
slipper and finally
cracked . This is called
Shoe Lift, the sound 3rd Stage
associated with it would 2nd Stage
be constant machine gun 1st Stage
noise typically worse at
full stroke.
21 Power
Innovative Fluid 22 Power
Innovative Fluid

THE FINAL STAGE OF SHOE LIFT HALF MOON SHAPED MARKS

A sure sign of shoe


lift

23 Power
Innovative Fluid 24 Power
Innovative Fluid

6
WEAR ON SHOE RETAINER FROM
ROLLED SHOES: THE TELL
SHOE FLANGES
TALE OF SHOE LIFT

25 Power
Innovative Fluid 26 Power
Innovative Fluid

BENT SEAL RETAINER SEAL RETAINER

As can be seen in the picture the retainer is clearly bent, that After removal of the shaft assembly, the seal retainer is
is from the case pressure pushing the seal against retainer. accessible. The seal retainer is placed between the outboard
The surface on the shaft where the seal rides will have a side of the pump and behind the bearing.
groove cut in it making unusable again. 27 28 Power
Innovative Fluid Power Innovative Fluid

7
SEAL RETAINER SEAL RETAINER REMOVED

Seal retainer in position


on the pump shaft.

Once the seal retainer has been removed the shaft seal is
exposed for removal. Investigate the seal closely and you
probably notice that it has been pushed out of the pump
29 Power
housing a little distance. 30
Innovative Fluid Innovative Fluid Power

MISCELLANEOUS FRETTED DRIVESHAFT

l INPUT SHAFT BROKEN


MISALIGNMENT

l CONTROL INSTABILITY
AIR
62 ©1998 Commercial Intertech Corp.

l PUMP VIBRATES
MISALIGNMENT 62. This splined drive shaft has been worn by fretting
corrosion. To prevent this damage the drive coupling should be
cleaned regularly followed with the application of a light coat of
synthetic grease.
31 Power
Innovative Fluid Innovative Fluid Power

8
HELPFUL HINTS FOR
ANALYZING BASKET CASES KEYS TO FAILURE ANALYSIS
l The last piece to fail will have the least amount of damage.
l Try to piece together the broken parts. This may seem like a l Don’t go into a problem with a preconceived
waste of time but many times you will observe things which idea about the cause.
can help you determine the original cause of failure. l Don’t assume anything, verify everything.
l Get the history of events:
l Don’t overlook the obvious.
What recently changed ?
What was going on just prior to failure ?
How long was pump running for?
Talk to the operators.
33 Power
Innovative Fluid 34 Power
Innovative Fluid