Sei sulla pagina 1di 5

2

SikaGrout
®
-114
2/4
Technical Data
Chemical Base
Mixture of cement, graded fine aggregates and additives
Density
(at +25˚C)

~ 2.20 kg/lt (mixed material)


Pot Life (at +25°C)
Approximately 4

5 hours after mixing.
Thickness
Minimum: 10 mm per pourMaximum: 75 mm per pour
Yield
Approximately 13 lt/25 kg bag
Mechanical StrengthsN/mm
2
(at 25°C)(w/p=0.15)
1 day 3 days 28 daysCompressive Strength (ASTM C109) ~ 30 ~ 45 ~ 65Flexural stren
gth (BS4551) ~14Bond strength (Pull off) >1.2
Expansion
+ 0.08% at 28 days (CRD C621)
Modulus of Elasticity
Approximately 35
’000 N/mm
2
(Static)
Initial Surface Absorption
10 min = 0.01 ml / (m
2
.sec) (BS1881 Part 208)30 min < 0.01 ml / (m
2
.sec)
Coefficient of ThermalExpansion
11x10
-6
m/m per °C
Application Details

Substrate Preparation
Concrete surfaces should be clean, sound and free from oil, grease, cementlaitance
and all loosely adhering particles. Absorbent surfaces should be saturatedthoroughly.
Metal surfaces (iron and steel) should be free from scale, rust, oil andgrease.
Mixing RatioConsistencyLt Water per 25 kgbagWater/Powder Ratio
Dry-pack / Trowelable 3.0 0.12Plastic consistency 3.25 - 3.75 0.13

0.15Flowable (max. strength) 3.75 - 4.00 0.15

0.16Highly flowable (max. flow) 4.00 - 4.25 0.16

0.17
Mixing
Add clean cold water into a suitable mixing container according to
the desiredconsistency. For a flowable mix 3.75 - 4.25 lt. per 25 kg bag will be
required. Add the
SikaGrout
®
-114
powder slowly and mix mechanically using a slow speeddrill and paddle (maximum.
500 rpm) for at least 3 minutes and until a smooth, evenconsistency, is achieved. Take
care that air is not entrapped during mixing.Scrape sides and corners of the mixing
container to ensure all the powder isthoroughly mixed and no lumps occur in the mix.
Application
After mixing let the mixed grout stand for approximately 5 minutes to allowentrapped air
to escape.Pour into the prepared area such that the grout has the shortest distance to
travel.Ensure that air displaced by the grout is allowed to escape.When carrying out
base plate grouting, ensure a sufficient head of pressure ismaintained to keep the
mortar flowing. All exposed areas of the mortar surface should be kept as small as
possible.
Curing
Treat exposed surfaces with Antisol
®
-E Curing compound or use other approvedcuring methods such as polyethylene
sheeting or wet hessian.

3
SikaGrout
®
-114
3/4
Cleaning
Clean mixing and application equipment with water immediately after use.Hardened
material can only be removed mechanically.
Notes on Application /Limitations
Use
SikaGrout
®
-114
for grouting only.Ensure formwork is secure and watertight to prevent movement and
leaking duringplacing and curing.Where maximum thickness exceeds 75mm, consider
the use of Sikacrete
®
-114. At high temperatures, use chilled water for mixing to keep the grout
temperaturebelow 30°C.In hot weather, base plates and foundations must be shaded
from direct sunlight.Condition bags of grout in a cooled environment prior to
use.Depending on requirements and site condition, the addition of up to 100% of
drysingle size and clean aggregates is possible. Trials are recommended to confirmthe
suitability and added quantity of the aggregates to be employed.For additional
information on
SikaGrout
®
-114
or other grouting materials contactour Technical Services Department.
4
SikaGrout
®
-114
4/4
Value Base
All technical data stated in this Product Data Sheet are based on laboratory
tests. Actual measured data may vary due to circumstances beyond our control
Local Restrictions
Please note that as a result of specific local regulations the performance of thisproduct
may vary from country to country. Please consult the local Product DataSheet for the
exact description of the product uses.
Health and SafetyInformation
For information and advice on the safe handling, storage and disposal of
chemicalproducts, users shall refer to the most recent Material Safety Data Sheet
containingphysical, ecological, toxicological and other safety-related data
Legal Notes
The information, and, in particular, the recommendations relating to the applicationand
end-use of Sika products, are given in good faith based on Sika's currentknowledge and
experience of the products when properly stored, handled andapplied under normal
conditions
in accordance with Sika’s recommendations. In
practice, the differences in materials, substrates and actual site conditions are suchthat
no warranty in respect of merchantability or of fitness for a particular purpose,nor any
liability arising out of any legal relationship whatsoever, can be inferredeither from this
information, or from any written recommendations, or from any other
advice offered. The user of the product must test the product’s suitability for the
intended application and purpose. Sika reserves the right to change the propertiesof its
products. The proprietary rights of third parties must be observed. All ordersare
accepted subject to our current terms of sale and delivery. Users must alwaysrefer to
the most recent issue of the local Product Data Sheet for the productconcerned, copies
of which will be supplied on reques

Potrebbero piacerti anche