INSTALLATION MANUAL
Model #TR3
TM
2/25/05
MECHANICAL INSTALLATION CAUTION: Turn-off all power before performing
any work on the wiring system.
Use only Listed or IEC rated wiring
RATINGS: devices and accessories.
Maximum voltage: 300 volts, 50/60 Hz
Wire using only #12 AWG or 2.5mm maximum, 90º C minimum
Use stranded wire only, 8 conductors maximum per conduit
Maximum amps per circuit:
20 (#12AWG) US & Canada, 16 (2.5mm) IEC
Maximum weight load: 2,500lbs. (1,134kg) 60"
(Safety factor of 3) [1524mm]
Conforms to UL 1573, CSA/CAN C22.2
No. 166-M1983, EN60598-2-17/A2:1991
AV / FIBER OPTICS
or
ELECTRICAL POWER AV / FIBER OPTICS
or
ELECTRICAL POWER
MOUNTING SLOTS
2
Litelab Corp. 251 Elm Street Buffalo, NY 14203 (716) 856-4491 fax: (716) 856-0156 www.litelab.com
CAUTION: Turn-off all power before performing
ELECTRICAL INSTALLATION any work on the wiring system.
Use only Listed or IEC rated wiring
devices and accessories.
Step One –
To lower BusPortTM into useable position, move
latch and lower unit carefully with manual support.
Do Not stand directly under unit.
Step Two –
Bring power wires (or AV/communication) to unit in
suitable flexible conduit, make sure the actual wires
extend beyond the flexible conduit connector point
at least 2.5 meters or 7.5 feet.
Step Three –
Feed exposed wires from step one in to the flexible
conduit on the BusPortTM and down into the junction
cavity. Then join feed conduit to BusPort conduit.
Step Four –
Wire all connections on BusPortTM.
3
Litelab Corp. 251 Elm Street Buffalo, NY 14203 (716) 856-4491 fax: (716) 856-0156 www.litelab.com
CAUTION: Turn-off all power before performing
RAISING & LOWERING UNIT any work on the wiring system.
Use only Listed or IEC rated wiring
devices and accessories.
Step Five –
To raise unit, depress catch with latch and manually push unit up into storage
position then release latch.
Pull down gently on coverplate to be sure the catch is engaged. Never stand directly
under unit and always be sure nothing is placed into BusPortTM when retracting.
4
Litelab Corp. 251 Elm Street Buffalo, NY 14203 (716) 856-4491 fax: (716) 856-0156 www.litelab.com
PROPRIETARY AND CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF LITELAB CORP. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF LITELAB CORP. IS PROHIBITED. REVISIONS
ECO# REV DESCRIPTION DATE APRVD
--- 000 --- 00/00/00 ---
FRONT VIEW
POWER PANEL
3/4" TRADE-SIZE COUPLING SIDE VIEW
[ 25mm FOR IEC VERSION] RETRACTED
CLEARANCE NEEDED: APPROX 60"[1524] FOR CONNECTION TO
SIDE VIEW - ATTENTION -
EXTENDED CONDUIT SYSTEM - BY OTHERS
ALLOW CLEARANCE 10 3/4"
FOR MOVING PARTS 272 16"
- ATTENTION -
4 11/16" ALLOW CLEARANCE 406
16" 119 FOR MOVING PARTS
406
COUNTER
BALANCE
SPRING(2)
3/4" FLEXIBLE
MOUNTING CONDUIT
FLANGE (2) TYPE: FMC MOUNTING
FLANGE (2)
24 1/8"
613
1/2" [12] DRYWALL
17 3/4"
4" ADD 1/8" [3] SHIM
450
102
32 9/16"
5/8" MOUNTING 5"
827 FLANGE (2) 127
16
8 3/4"
STAGEPIN / EDISON
222
TRIM-RING NOTES
BELOW
5 1/2"
MOVE LATCH TO RELEASE
381
15"
140
TWO REMOVABLE BLANK PANELS PROVIDED (#40400) 4" HOLE CUT-OUT
DRYWALL- ~ ONE WIRING CHAMBER IS FOR ELECTRICAL ONLY 102 2"
RING ~ THE OTHER IS FOR EITHER AV OR ELECTRICAL 51
9/16"
-----------------------------------------------------------------------------
14
ARM
CONSULT LITELAB REP FOR OTHER FACTORY OPTIONS: 1"
TRIM-RING ~ PANEL WITH 2 TWISTLOCKS & 1 EDISON (#40401) 25
2 7/16" ~ PANEL WITH 2 STAGEPINS & 1 EDISON (#40402)
62 ~ BLANK PANEL FOR AV APPLICATIONS (#40403)
~ REQUESTED CUSTOM PANEL (40403-MOD)
HOLES FOR 1-1/2" SCHEDULE-40 BLACK PIPE OR ROUND BUSRUN (2);
SECURE WITH 1/4" x 4"CLEVIS-PINS (2-PROVIDED) LATCH FOR SECURING ARM
WHEN IN STOWED POSITION
7 3/4"
196
MAXIMUM LOAD: 2500 LBS (1132 KG)