Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
David Chan
Senior Product Specialist
Shimadzu Asia Pacific
David Chan
Senior Product Specialist
Shimadzu Asia Pacific
Next-Era (Nexera) of Digital Technology in a Laboratory
Automation Investment
Automation workflow Effective asset
requires less human management to ensure
operation return of investment
Machine learning makes Flexible design to allow
machines smarter easy expansion
Better standards of Maximized uptime
operation and results allows greatest
productivity
First AI Enabled & IoT-driven Analytical LC
9
Routine Workflow
Start-
up
Mobile
Shut- Phase
down
Set-up
Post-run
Column
System
Equil.
monitoring
Start
Analysis
System
Check
Mobile
Phase
Check
A New Benchmark of Intelligence
Auto
Start-
up
Checking
Mobile mobile phase level
Auto
Shut- Phase
down Set-up Alerts the mobile
phase running out
Post-run
Column Mobile
Remote
Equil. phase
monitoring monitor
Start
Analysis
System
Check
Mobile
Phase
Check
Advanced Real-Time Mobile Phase Monitoring
The gravimetry of the mobile phase is observed through smart devices
Automatically calculate mobile phase reservoir volume
An alert is sent in case of shortage
MPMChecker LabSolutions
Auto
Start-
up
Checking
Mobile mobile phase level
Auto
Shut- Phase
down Set-up Alerts the mobile
phase running out
Post-run
Column Mobile
Remote
Equil. FlowPilot phase
monitoring monitor
Start
Analysis
System
Check
Mobile
Phase
Check
FlowPilot Protects Column
FlowPilot ramps the mobile phase flowrate gradually to the set point automatically
Avoid sudden surge of excessive pressure applied on the column, to protect the column
in the automated start-up.
Prevent extra
pressure
1mL/min
1mL/min
③
0.5 ②
mL/min
①
Auto
Start-
up
Checking
Mobile mobile phase level
Auto
Shut- Phase
down Set-up Alerts the mobile
phase running out
Post-run
Column Mobile
Remote
Equil. FlowPilot phase
monitoring monitor
AI SAKit
Start
Analysis
System
Check Checking
Auto-
mobile phase level
Mobile
diagnostics Phase
& recovery Check
Alerts the mobile
phase running out
Auto-Diagnostics and Auto-Recovery
Detect the
fluctuation
Chemist does not need to be physical present when abnormal condition appears
Nexera Series can perform auto-correction; ensure maximum system up-time
Intelligent Workflow
Auto
Preventive Start-
maintenance up
Checking
Mobile mobile phase level
Auto
Shut- Phase
Smart
Service
down Set-up Alerts the mobile
Net phase running out
Lab
Management
Post-run
Column Mobile
Remote
Equil. FlowPilot phase
monitoring monitor
Easy
Access
from all
locations AI SAKit
Start
Analysis
System
Check Checking
Auto-
mobile phase level
Mobile
diagnostics Phase
& recovery Check
Alerts the mobile
phase running out
Smart Service Net
Gives the appropriate maintenance timing by predicting from the use history
Good Laboratory Management practice
The maintenance
Predicted date date is predicted.
History
Prediction curve
2018/09/01 2019/05/01
2020/01/01
Email about the
maintenance
The use history of consumable part is shown.
Auto
Preventive Start-
maintenance up
Checking
Mobile mobile phase level
Auto
Shut- Phase
Smart
Service
down Set-up Alerts the mobile
Net phase running out
Lab
Management
Post-run
Column Mobile
Remote
Equil. FlowPilot phase
monitoring monitor
Easy
Access
from all
locations AI SAKit
Start
Analysis
System
Check Checking
Auto-
mobile phase level
Mobile
diagnostics Phase
& recovery Check
Alerts the mobile
phase running out
EFFICIENCY
20
A New Benchmark of Efficiency
(x10,000,000) (x10,000)
1.5
2.0 Carry over:
0.0002%
1.0 (MS/MS detection)
0.5 1.0
400mg/L x 1uL
Caffeine in water
Blank
0.0
= 43 h saved/ year
Minimizing the temp change Temp-
10 unit
contorolling minAmbient
fasterairthan other instruments
Dry & cool air
255Dry
days
& cool X
air 10 min
Add more samples.
X 5 times/ day = 10 min faster than other autosamplers
256 h saved/ year
Radiatior
Fan
A bump to change the direction of airflow
26
Photodiode Array Detector
20 ℃
mAU Area RSD:
2.5 SPD-M40 0.62% Heat
discharger
0
-2.5
spectrom
-5.0 Lamp eter
Area RSD:
-7.5
1.87% Flow
cell Advanced
-10.0
Other vendor’s TC-Optics
-12.5 PDA
3.0
Ketoprofen 2.5
(mAU)
R2 = 0.9998
Ketoprofen
2.5
Impurity A
5.0
2.0
0.245 mg/L (lowest conc)
4.0
2.0 Bias of QC: Δ -2.1%
Impurity B
RSD: 0.72 %(n=6) 1.5 3.0
(Ketoprofen)
Impurity C
1.5
0.04 2.0
1.0
1.0 1.0
0.02
0.5 0.0
0.5
2.00 2.50 3.00 (min)
0 5 10 0.0
0.0
Excellent
0 250
dynamic
500
range
750
Conc.(mg/L) linearity
0.0 ensures
1.0 excellent2.0precision,3.0
and
(min)
(mg/L) (n=6)
With
UV-cut-off Flow cell (magnification)
Path 1 Time-saving
New Nexera
Patj 2
Integrated two analytical systems into the single platform; enables analysis of
two independent samples through independent flow channels resulting in twice
the amount of samples processed in the same time
A New Benchmark of Design
The futuristic & sleek design of Nexera Series promises no compromise on performance
Entries
more than 5,500
Red Dot awards granted 1,549
The Red Dot Design Award is one of the 3 major design awards in the world,
alongside the German iF Design Award and the US IDEA Award.
• New Nexera Series was award Frost & Sullivan 2019 Global High
Performance Liquid Chromatograph New Product Innovation
Award
• Award was presented by Dr. Satish Lele Senior Vice President,
Frost & Sullivan Asia Pacific
Brand statement “Excellence in Science”
We in the Shimadzu Group have delivered products and services to enable our customers around the world to develop a diverse range of
new products, to protect and improve the environment, and to improve the health and lives of mankind. This brand statement represents our
sense of pride in this endeavor. It is our commitment to society and ourselves that Shimadzu remains dedicated in our pursuit of technology
and accumulation of knowledge, so that we can offer even more outstanding technologies, products, and services, so as to be recognised
for excellence in the field of science.