Qty. Description
1 SLV.25.A25.30.2.60J.C
Non-self-priming, single-stage, centrifugal pump designed for handling wastewater, process water and unscreened
raw sewage.
The pump is designed for intermittent and continous operations in submerged installation. The efficient
SuperVortex impeller provides passage of long fibres and solids up to 65 mm and is suitable for wastewater with a
dry matter content of up to 5 %.
A unique stainless-steel clamp assembling system enables quick and easy disassembly of the pump from the
motor unit for service and inspection. No special tools are required. Pipework connection is via a ANSI flange.
Controls:
Moisture sensor: with moisture sensors
Water-in-oil sensor: without water-in-oil sensor
Liquid:
Pumped liquid: Any Newtonian liquid
Maximum liquid temperature: 40 °C
Density at selected liquid temperature: 998.2 kg/m³
Technical:
Actual calculated flow: 20.11 m³/h
Resulting head of the pump: 2.182 m
Type of impeller: SUPER VORTEX
Maximum particle size: 65 mm
Primary shaft seal: SIC/SIC
Secondary shaft seal: CARBON/CERAMICS
Approvals on nameplate: CSA
Curve tolerance: ANSI/HI11.6:2012 3B2
Materials:
Pump housing: Cast iron
EN 5.1301 EN-GJL-250
ASTM A48-250B
Impeller: Cast iron
EN 5.1301 EN-GJL-250
ASTM A48-250B
Motor: EN-GJL-250
Installation:
Maximum ambient temperature: 40 °C
Flange standard: ANSI
Pump inlet: 80
Pump outlet: 65
Date: 23/09/2019
Qty. Description
Pressure rating: PN 10
Maximum installation depth: 20 m
Frame range: B
Electrical data:
Power input - P1: 3 kW
Rated power - P2: 2.2 kW
Mains frequency: 60 Hz
Rated voltage: 3 x 208-230 V
Voltage tolerance: +10/-10 %
Max starts per. hour: 20
Rated current: 9.5-8.9 A
Starting current: 68.3 A
Cos phi - power factor: 0.89
Cos phi - p.f. at 3/4 load: 0.85
Cos phi - p.f. at 1/2 load: 0.78
Rated speed: 3481 rpm
Motor efficiency at full load: 85.0 %
Motor efficiency at 3/4 load: 85.8 %
Motor efficiency at 1/2 load: 83.8 %
Number of poles: 2
Start. method: direct-on-line
Enclosure class (IEC 34-5): IP68
Insulation class (IEC 85): H
Explosion proof: no
Length of cable: 15 m
Cable type: SEOOW 600V
Others:
Net weight: 65 kg
Date: 23/09/2019
99034748 SLV.25.A25.30.2.60J.C 60 Hz
H SLV.25.A25.30.2.60J.C, 60Hz eta
[m] [%]
Q = 20.11 m³/h
H = 2.182 m
n = 60 % (35.9Hz) 50
18 45
100 %
16 40
14 35
12 30
10 25
8 20
6 60 % 15
4 10
2 5
3.0 12
P1 (motor+freq.converter)
2.5 10
P2
2.0 8
1.5 6
1.0 4
0.5 2
P1 (motor+freq.converter) = 0.645 kW
P2 = 0.461 kW
NPSH = 1.34 m
0.0 0
Date: 23/09/2019
H SLV.25.A25.30.2.60J.C, 60Hz eta
Description Value [m] [%]
Q = 20.11 m³/h 50
General information: H = 2.182 m
Product name: SLV.25.A25.30.2.60J.C n = 60 % (35.9Hz)
18 45
Product No: 99034748
100 %
EAN number: 5712605504757 16 40
5712605504757
Technical: 14 35
Actual calculated flow: 20.11 m³/h
12 30
Max flow: 50 m³/h
Resulting head of the pump: 2.182 m 10 25
Head max: 17.2 m
Type of impeller: SUPER VORTEX 8 20
Maximum particle size: 65 mm
Primary shaft seal: SIC/SIC 6 60 % 15
DN65
19.1
x
M16
8
x
396
246
139.7
102
684
152.4
321
171
Pump outlet: 65
Pressure rating: PN 10
Maximum installation depth: 20 m
171
Inst dry/wet: SUBMERGED 321
Installation: Vertical
Frame range: B 152.4
Liquid: 8 x M16
Date: 23/09/2019
Description Value
Insulation class (IEC 85): H
Explosion proof: no
Motor protec: THERMAL SWITCH
Length of cable: 15 m
Cable type: SEOOW 600V
Controls:
Control box: not included
Moisture sensor: with moisture sensors
Water-in-oil sensor: without water-in-oil sensor
Others:
Net weight: 65 kg
Date: 23/09/2019
99034748 SLV.25.A25.30.2.60J.C 60 Hz
171
321
152.4
8 x M16
684
DN65
102
139.7
246
396 4 x 19.1 DN80
Date: 23/09/2019
99034748 SLV.25.A25.30.2.60J.C 60 Hz
544
394
81
1.5
175
65
748
559
479
64
266
4XM16 1
210
95
140
730
Date: 23/09/2019
99034748 SLV.25.A25.30.2.60J.C 60 Hz
508.5
280
18
65
812
389
128
330