Sei sulla pagina 1di 2

INNOVATIVE TECHNOLOGIES.

RELIABLE SOLUTIONS

Axiom II vsd
Induction Motors and Permanent Magnet Motors with one drive to optimize field operating expense
The Axiom II is the universal variable speed DRIVEWORKSEZ SOFTWARE
APPLICATIONS drive (VSD) that efficiently and safely operates DriveWorksEZ is powerful programming
• Unconventional wells a variety of systems including conventional software that is built-in to the AXIOM II
• Unstable flow ESP, induction motors, high efficiency and provides ‘‘PLC’’ capabilities. It allows
• High GOR permanent magnet motors (PMM), the wide implementing complex and application tailored
range wear resistant (WR2) ESP system and VSD functionality.
ENHANCED SAFETY FEATURES the progressing cavity pump (PCP) systems.
DriveWorksEZ allows the end user to
The Axiom II advanced software features customize and adapt the AXIOM II to their
• touchsafe components in drive enclosure
include but are not limited to gas lock application needs in fast and intuitive manner.
• Disconnect switch inside input junction box detection, hard to start/stuck pumps and
• Pre-wired controls junction box scale build up prevention. Custom programing
• External grounding stud is available for specific/challenging projects. SOFTWARE FEATURES
• Door & circuit breaker locking provision
The AXIOM II has an integrated enhanced sine Pump Unfreeze Function
wave filter which reduces rig time and footprint. The Pump Unfreeze is designed for hard
FEATURES & BENEFITS It also provides a near sinusoidal electrical to start or stuck pumps; it uses the latest
• Adaptable universal drive for conventional waveform to the downhole equipment and software features and enhancement of the
induction motors or permanent magnet delivers one of highest efficiency electrical proven technology to free the majority of stuck
motors: VSD systems. pumps.
- Optimizes VSD inventory Safety is a prime focus; all internal parts are Pump Shaking Algorithm
• Effectively and safely operates: touchsafe (IP20 equivalent), the disconnect The Pump Shaking algorithm alternates the
- Conventional ESPs switch is mounted inside the input junction motor speed with adjustable frequency limits,
- High efficiency systems box, hence no power will be present in acceleration and deceleration to prevent or
- Wide flow/wide range pumping systems the drive cabinet when the switch is off. free scale deposits from the pump stages.
- PCP systems An integral control box mounted to the Gas Lock Ride Thru
side allows SCADA, Analog and Digital I/O The Gas Lock Ride Thru is a custom control
• Advanced ESP software interconnections easy access without having
- Pump Unfreeze function for hard-to start algorithm specific for breaking gas lock
to open the drive cabinet door where high conditions.
or stucked pumps volatage is present.
When the Gas Lock condition is detected, the
• Custom programing DriveWorksEZ: Drive ratings range from 112 A to 937 A and AXIOM II will follow the specific algorithm
- Application-specific algorithms will be offered initially in 6, 12, or 18 pulse for several attempts, or until the Gas Lock
• Integrated enhanced output filter: for harmonic mitigation with 380 V AC or 480 condition is no longer present.
- Minimizes installation time V AC ratings.
- Reduces overall footprint
- Reduces electrical stresses on downhole
equipment
- Increases reliability & drive efficiency Control Algorithms:
• External USB port: - V/f Control for Induction motors
- Safe data download - V/f Control with PG Speed Feedback
• External 110 V outlet: - Open & Closed Loop Vector Control
- Added convenience - Open & Closed Loop Vector Control
• Advanced HMI: for PMM
- Graphical touch screen display - Advanced Open Loop Vector Control
- Enhanced data logging for PMM
- Ease of navigation
• HOA (hand-off auto) switch:
- Selectable mode of operation
• Configurable Inputs/Outputs (digital & analog)
The AXIOM II is fully UL and CSA
certified VSD in a NEMA 3R cabinet.
AXIOM II OPERATOR MENU

Parameters Specifications
480 V AC -25 % / +10 %
Input voltage
380 V AC -15 % / +15 %
Input frequency 47-63 Hz
Power factor > 0.95 across all speeds
Output frequency 10-240 Hz (0.1Hz resolution)
Output distortion <5 % after PWM filter
Intermittent overload 150 % for 1 min
Maximum operating ambient temperature 55 0C / 131 0F

Minimum storage and operating temperature


-40 0C / -40 0F
(has internal heaters)

Noise <75 bd at 1 m

- RS485 (115 kbps) MODBUS Slave SCADA


- interface for monitoring and control
- 5 digital inputs (24 V DC)
SCADA/ I/O built in (i.e. more options
- 3 analog inputs (0-10 V DC/ 4-20 mA)
available with additional cards)
- 1 fault relay (Form C)
- 3 relay outputs (Form A)
- 2 analog outputs (0-10 V DC/ 4-20 mA)

Fault & event logging Incorporated in the AHMI with SD card

International Headquarters
Office 22 The Gate Building, Level 15
Dubai International Financial Centre
P.O. Box 121208, Dubai UAE
Tel: +971 4 401 95 11
e-mail: global@borets.com

Potrebbero piacerti anche