TESTS OF BRICK FOR MASONRY

Name of Project : Alpla India Pvt .Ltd


Name of Contractor : Rohan Builders India Pvt.Ltd
Supplier Name : Jalaram Enterprises
Sample No : 01 Date of Sampling 19-Dec-19
Location : Near Office Area Date of Testing 20-Dec-19
Quantity : 05 Sampling ID DMC
Water Absorption Test Compressive Strength
Size in cm.
Sr. No.
W2 Dry Weight in W1 Weight of W2-W1 X100 Water Absorption Average Water Compressive Strength Average Compressive
Ultimate Load In kN
gm. Water W1 % Absorption % kg/cm2 Strength kg/cm2
(LxBxH)

1 230X100X75 2.632 2.798 0.166 16.60 110 4.78

2 230X100X75 2.708 2.874 0.166 16.60 130 5.65


16.00 5.1
3 230X100X75 2.654 2.811 0.157 15.70 140 6.09

4 230X100X75 2.744 2.895 0.151 15.10 90 3.91

For Bricks minimum one test per 50,000 nos.


Once for each 5 specimen and subsequently when warranted due to chang in quality.