Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Course Catalog
2020 Edition—United States and Canada
Agilent University—a Complete
Curriculum of Flexible Learning Solutions
Welcome to Agilent University! Develop skills and improve laboratory workflows with
a wide range of learning options—from beginner to advanced, from on-site to on-
demand. Enhance your lab technicians’ and researchers’ productivity and confidence
with your new or existing Agilent equipment.
Choose the learning environment, delivery method, and level of content that matches
your preferred learning style—and your lab’s budget.
— Classroom training
— On-site training
— Online, on-demand training
2
Agilent University—2020 Edition
Investments in education improve laboratory staff productivity by enhancing skills necessary for
routine procedures. Education leads to utilizing the full potential of instruments, as staff members
gain knowledge and insights into the latest techniques. Well-educated staff members—taught by
subject matter experts and certified trainers—are more dedicated to your organization and feel
more confident in their accomplishments.
Proper training quickly leads to greater productivity and increases the value of your investment.
Table of Contents
Education Courses Page
Vacuum Courses 37
█
4
Atomic Gas Liquid Mass Software and General Training
TOC Vacuum
Spectroscopy Chromatography Chromatography Spectrometry Informatics Information
ICPMS-7700-2100c 7700 Series ICP-MS Techniques & Operation To request a quote, email
The course is designed as a beginner to intermediate level training for Agilent agilent_university@agilent.com
customers and is aimed at providing a comprehensive overview of the Agilent 7700
Series ICP-MS technique and Agilent’s MassHunter software. Some advanced topics
(e.g., laser ablation, direct organic solvent sampling, and chromatography sample
introduction) are introduced, but not covered in depth.
On-Site Only | 4 Days
ICPMS-8800-2100c 8800 Series ICP-MS Techniques & Operation To request a quote, email
The course is designed as a beginner to intermediate level class for Agilent agilent_university@agilent.com
customers and is aimed at providing a comprehensive overview of the Agilent 8800
Series ICP Triple Quad and Agilent’s MassHunter software. Some advanced topics
(e.g., laser ablation, direct organic solvent sampling, and chromatography sample
introduction) are introduced.
On-Site Only | 4 Days
ICPMS-8900-2100c Agilent 8900 ICP-MS Techniques & Operation 03/17/20 Wood Dale IL
The course offers a comprehensive overview of the Agilent 8900 Triple Quad 07/07/20 Wood Dale IL
ICP-MS and Agilent MassHunter software. 11/10/20 Wood Dale IL
6
Atomic Gas Liquid Mass Software and General Training
TOC Vacuum
Spectroscopy Chromatography Chromatography Spectrometry Informatics Information
8
Atomic Gas Liquid Mass Software and General Training
TOC Vacuum
Spectroscopy Chromatography Chromatography Spectrometry Informatics Information
10
Atomic Gas Liquid Mass Software and General Training
TOC Vacuum
Spectroscopy Chromatography Chromatography Spectrometry Informatics Information
GC-7890-2104c Agilent 7890 GC & OpenLab EZChrom Operation To request a quote, email
This course is designed for those who want to enhance their skills in the techniques agilent_university@agilent.com
and software operation of the Agilent 7890 with OpenLab CDS EZChrom Edition.
The course utilizes a lecture format with instrument laboratories. Topics include
creating qualitative and quantitative methods, sequencing, GC instrument operating
principles, OpenLab basic administration and hardware maintenance.
On-Site Only | 3 Days
GC-8890-2100cV2 Agilent 8890 GC Operation with OpenLab CDS To request a quote, email
ChemStation Edition agilent_university@agilent.com
Are you curious about how an Agilent gas chromatograph (GC) operates, what you
need to do to keep your GC system running efficiently, or how it works with OpenLab
CDS ChemStation Edition C.01.10? Improve your efficiency with Agilent’s innovative
gas chromatography systems. Use the tools in OpenLab CDS ChemStation Edition
to save time in the analysis, interpretation, and reporting workflows so you can
identify key information and solve problems faster.
–– Discuss theory and operation of the Agilent 8890 GC.
–– Construct a new method to acquire data, run single samples and automate the
sample acquisition by using the OpenLab CDS ChemStation Edition Sequence in
hands-on lab exercises.
–– Develop a new method used to process data, analyze the data and then optimize
the data analysis method using a targeted approach.
–– Produce reports and modify existing OpenLab CDS ChemStation Edition report
templates to create one that is customized for your unique data.
–– Locate inlet and detector components that require maintenance to keep your
system running optimally and practice replacing them in the hands-on lab.
On-Site Only | 4 Days
12
Atomic Gas Liquid Mass Software and General Training
TOC Vacuum
Spectroscopy Chromatography Chromatography Spectrometry Informatics Information
GC-8890-2101c Agilent 8890 GC Operation with OpenLab CDS To request a quote, email
Are you curious about how an Agilent gas chromatograph (GC) operates, what agilent_university@agilent.com
you need to do to keep your GC system running efficiently, or how it works with
OpenLab CDS Version 2.4? Improve your efficiency with Agilent’s innovative gas
chromatography systems. Use the tools in OpenLab CDS Version 2.4 to save time
in the analysis, interpretation, and reporting workflows so you can identify key
information and solve problems faster.
–– Discuss theory and operation of the Agilent 8890 GC.
–– Construct a new method to acquire data, run single samples and automate the
sample acquisition by using the OpenLab CDS Version 2.4 Sequence in hands-on
lab exercises.
–– Develop a new method used to process data, analyze the data and then optimize
the data analysis method using a targeted approach.
–– Produce reports and modify existing OpenLab CDS Version 2.4 report templates
to create one that is customized for your unique data.
–– Locate inlet and detector components that require maintenance to keep your
system running optimally and practice replacing them in the hands-on lab
On-Site Only | 4 Days
14
Atomic Gas Liquid Mass Software and General Training
TOC Vacuum
Spectroscopy Chromatography Chromatography Spectrometry Informatics Information
HPLC-1200-2100c Agilent 1200 Series HPLC (3D) ChemStation B To request a quote, email
Operation agilent_university@agilent.com
This course provides the user with laboratory exercises on the operation and
maintenance of the Agilent 1100/1200 Series Liquid Chromatograph equipped with
a Diode Array controlled by the HPLC (3D) ChemStation.
On-Site Only | 4 Days
16
Atomic Gas Liquid Mass Software and General Training
TOC Vacuum
Spectroscopy Chromatography Chromatography Spectrometry Informatics Information
HPLC-INF-2106c Agilent Infinity Series HPLC (3D) EZChrom Operation To request a quote, email
This course is designed for those who want to enhance their skills in the techniques agilent_university@agilent.com
and software operation of the Agilent Infinity Series HPLC 3(D) with OpenLab
EZChrom. The course utilizes a lecture format with instrument laboratories. Topics
include creating qualitative and quantitative methods, sequencing, diode array
optimization, OpenLab basic administration and hardware maintenance.
On-Site Only | 3 Days
18
Atomic Gas Liquid Mass Software and General Training
TOC Vacuum
Spectroscopy Chromatography Chromatography Spectrometry Informatics Information
20
Atomic Gas Liquid Mass Software and General Training
TOC Vacuum
Spectroscopy Chromatography Chromatography Spectrometry Informatics Information
GCMS-5977-2100cV5
Agilent 5977 GC/MS Techniques & Operation with 02/11/20 Alpharetta GA
MassHunter Data Analysis 04/21/20 Alpharetta GA
06/23/20 Alpharetta GA
Ensuring that a GC/MS system is turning out accurate results is a huge 08/25/20 Alpharetta GA
responsibility. Your job is very important and having the skills to fully utilize your 11/03/20 Alpharetta GA
GC/MS system is paramount to your success. 02/02/21 Alpharetta GA
GCMS-5977-2109cV3 Agilent 5977 GC/MS Techniques & Operation with 05/05/20 Alpharetta GA
OpenLab CDS 10/27/20 Alpharetta GA
This course is designed for those operators who desire to learn both essential and
advanced features to run samples and sequences, review data, set up methods that
include calibration, and perform routine maintenance.
Hands On | TC 2800 | 4 Days
22
Atomic Gas Liquid Mass Software and General Training
TOC Vacuum
Spectroscopy Chromatography Chromatography Spectrometry Informatics Information
24
Atomic Gas Liquid Mass Software and General Training
TOC Vacuum
Spectroscopy Chromatography Chromatography Spectrometry Informatics Information
GCMS-CS-2100c GC/MSD ChemStation Data Analysis & Reporting To request a quote, email
This course is designed for those operators who want to enhance their skill in the agilent_university@agilent.com
use of the Agilent GC/MSD ChemStation. If you require instruction in tuning and
data acquisition, please see GCMS-5975-2100c.
On-Site Only | 3 Days
LCMS-6100-2100cV2
Agilent 6100 Series SQ LC/MSD Techniques and 03/24/20 Cedar Creek TX
Operation with OpenLab CDS ChemStation C.01.09 09/15/20 Cedar Creek TX
Do you need more hands-on experience operating and developing acquisition
methods for your single quadrupole LC/MS applications? Do you want to improve
your analytical workflow?
Gain confidence in operating and troubleshooting your Agilent Single Quadrupole
LC/MS instrument. Improve your productivity by automating data acquisition, data
processing and reporting using the tools provided in OpenLAB CDS Chemstation.
–– Execute a routine maintenance schedule to minimize instrument downtime.
–– Optimize your mass spectrometry settings and select appropriate source
conditions for your application to acquire higher quality data.
–– Automate your data acquisition and data processing to increase your
productivity.
–– Create data processing and reporting workflows tailored to your application.
Hands On | TC 3200 | 4 Days
26
Atomic Gas Liquid Mass Software and General Training
TOC Vacuum
Spectroscopy Chromatography Chromatography Spectrometry Informatics Information
LCMS-6200-2100cV4
Agilent 6200 Series TOF LC/MS Techniques and 03/10/20 Lexington MA
Operation with MassHunter 06/16/20 Lexington MA
Have you recently become an operator of an Agilent LC/TOF system but are 09/22/20 Lexington MA
overwhelmed by its complexity? Do you need more experience on how to create 12/15/20 Lexington MA
acquisition and data processing methods for your small or large molecule projects?
Produce the best quality high resolution accurate mass data from your Agilent
LC/TOF by maintaining optimal performance of your MS. Extract the most
information from your accurate mass data using the data processing power of
MassHunter software.
–– Acquire high quality accurate mass data by tuning, calibrating, and optimizing
your LC/ TOF for your application.
–– Execute a routine maintenance schedule to minimize instrument downtime.
–– Mine your accurate mass data for unknown and known compounds using
specific workflows and feature-finding algorithms.
–– Create and manage your own compound database and use it for screening
and identification of compounds specific to your samples.
–– Readily set up quantification methods to quantify your target compounds
using calibration curves and flag any out-of-range results, then generate a
report for the analysis.
–– Create a quantification and confirmation data processing method using the
all ion fragmentation (AIF) approach.
–– Obtain rapid results for your protein digests and characterize your intact
proteins quickly using workflows specifically designed for these tasks.
Hands On | TC 4000 | 4 Days
LCMS-6400-2105cV2
Agilent LC/QQQ MassHunter Data Analysis To request a quote, email
with B.08.00 agilent_university@agilent.com
This course is designed for those who want to enhance their skills using MassHunter
Qualitative Analysis B.08.00 and MassHunter Quantitative Analysis B.08.00. These
programs are used to process and generate reports for data acquired with the Agilent
6400 Series QQQ LC/MS systems. The course utilizes a lecture format with laptop
laboratories. Topics include general principles of LC/MS/MS, MassHunter Qualitative
and Quantitative Analysis software, and reporting.
On-Site Only | 2 Days
28
Atomic Gas Liquid Mass Software and General Training
TOC Vacuum
Spectroscopy Chromatography Chromatography Spectrometry Informatics Information
LCMS-6500-2105cV3 Agilent Q-TOF LC/MS Data Analysis & Reporting To request a quote, email
Do you need more experience on how to create data processing methods for agilent_university@agilent.com
your small molecule projects?
Extract the most information from your accurate mass data using the data
processing power of MassHunter software.
–– Mine your accurate mass data for unknown and known compounds using
specific feature-finding algorithms.
–– Screen and identify found compounds using your personal compound database
library and flag data that is outside the specified match score.
–– Quantitate target compounds by generating calibration curves and flag data
outside specified ranges.
–– Create custom reports for your applications.
On-Site Only | 2 Days
30
Atomic Gas Liquid Mass Software and General Training
TOC Vacuum
Spectroscopy Chromatography Chromatography Spectrometry Informatics Information
LCMS-ULTV-2100cV2 Agilent Ultivo LC/TQ Techniques and Operation with 03/10/20 Lexington MA
MassHunter 06/09/20 Lexington MA
Do you need more hands-on experience operating and building acquisition methods 09/01/20 Lexington MA
for your Agilent Ultivo LC/Triple Quadrupole applications? Do you find quantitative 12/08/20 Lexington MA
analysis a challenge to set up?
Gain confidence in operating and troubleshooting your Agilent Ultivo LC/TQ system.
Improve your productivity by automating data acquisition and data processing.
–– Optimize your mass spectrometry and source conditions for your application
to acquire higher quality data.
–– Build the acquisition method and select the data processing applicable to
your type of analysis.
–– Automate your acquisition using worklists, incorporate data processing into
the workflow increasing your productivity.
–– Create quantitative and reporting methods tailored to your application.
–– Execute a routine maintenance schedule to minimize instrument downtime.
Hands On | TC 4000 | 4 Days
32
Atomic Gas Liquid Mass Software and General Training
TOC Vacuum
Spectroscopy Chromatography Chromatography Spectrometry Informatics Information
34
Atomic Gas Liquid Mass Software and General Training
TOC Vacuum
Spectroscopy Chromatography Chromatography Spectrometry Informatics Information
SW-OLII-2800cV5 OpenLab CDS Administration for Client/Server and To request a quote, email
Workstation Plus agilent_university@agilent.com
Have you purchased a new instrument or recently upgraded to OpenLab CDS
with Client/Server or Workstation Plus? Do you want to make sure your system
is configured properly for your enterprise lab, with the appropriate privileges and
audit trails to ensure you are in compliance with your SOPs? Walk through the
system setup process step-by-step. Identify the features that will apply to your lab
and workflows. Customize the software to make the most of all the built-in features
for security, audit trails, and lab management.
–– Create users, groups, and roles, with tailored privileges.
–– Restrict privileges to projects and instruments.
–– Discover all of your audit trails and activity logs throughout the OpenLab CDS
system, including Control Panel, Acquisition, and Data Analysis.
–– Learn to navigate your Content Management user interface.
–– Determine the best backup and restore options and server maintenance
for your lab.
On-Site Only | 1 Day
SW-OLII-3170c OpenLab 2.1 CDS Custom Reporting and To request a quote, email
Custom Calculations agilent_university@agilent.com
This classroom training will provide the skills necessary to design and create
custom OpenLab 2.1 Intelligent Reports. Topics follow a typical report creation
lifecycle, integrating report requirements definition and design with the skills
needed to build a report that satisfies those requirements.
On-Site Only | 2 Days
36
Atomic Gas Liquid Mass Software and General Training
TOC Vacuum
Spectroscopy Chromatography Chromatography Spectrometry Informatics Information
Vacuum Courses
Course No. Course Name Date City State/Prov
VAC-0GEN-1210c Vaccum Leak Rate Test and Measurement 01/31/20 Santa Clara CA
This course is a companion to the Basic Vacuum Practice course, building 03/13/20 Lexington MA
on the vacuum and helium mass spectrometer leak detector (HMSLD) 04/17/20 Santa Clara CA
fundamentals learned in BVP. 06/19/20 Lexington MA
07/24/20 Santa Clara CA
Lecture Only | TC 500 | 1 Day 09/18/20 Lexington MA
10/09/20 Santa Clara CA
10/16/20 Oak Ridge TN
10/23/20 Albuquerque NM
Cancellation or rescheduling must be made within 10 Agilent training courses are also priced in Agilent
business days prior to the start of the course to avoid a University Training Credits. These prepaid credits can be
50% billing fee to the attendee. A one-day cancellation or applied to any Agilent training course within 24 months
non-attendance will result in full billing. of purchase. For more information on Agilent University
Training Credits visit:
Agilent reserves the right to cancel any course 10 www.agilent.com/chem/trainingunits
business days prior, if minimum enrollment is not met.
The purchase of non-refundable airline tickets is not
On-demand courses
recommended due to possible course cancellations.
Some courses are offered on an “On-Demand” basis.
Agilent training classes are intended solely for Agilent If you are interested in a course that is not currently
instrumentation end-users and Agilent-approved service scheduled or not offered in your area, call our registrar
providers. and place your name on a wait list.
Class times
38
Notes
Learn more:
www.agilent.com/crosslab/university
Contact us:
1-800-227-9770, Option 1, 3
agilent_university@agilent.com