TEST REPORT

CT F : 27
CUSTOMER INFORMATION REPORT AND SAMPLE INFORMATION
Palsani Green Power LLP ULR No : TC76952000000001F
87/110 Dr. Radha Krishnan Road Mylapore Test Report No : R191200414.001 Test Report Date : 02-1-2020
Date Sampled : 26-12-2019 Received Date : 30-12-2019
Chennai-600004, Date Analysed : 31-12-2019
TAMIL NADU, India Sample Type : Ad Blue
Kind Atn :Dhairya Palsani Conditon : Sample received in plastc container
Reference No.: Sample Desc : Batch No-1912201227
Reference Date: 31-12-2019

SrNo TEST DESCRIPTION LIMITS RESULTS TEST METHOD


1 Insoluble Mater ppm Max 20 4.0 ISO 22241-2 2019 Annex G
2 Urea Content % 31.8 - 33.2 32.4 ISO 22241-2 2019 Annex. C
3 Density at 20 °C kg/m3 1087.0 - 1093.0 1087 ISO 3675 1998
4 Refractve Index - 1.3814 - 1.3843 1.3828 ISO 22241-2 2019 Annex C
5 Alkalinity % Max 0.2 0.01 ISO 22241-2 2019 Annex. D
6 Biuret Content % Max 0.3 0.26 ISO 22241-2 2019 Annex. E
7 Phosphate ppm Max 0.5 < 0.05 ISO 22241-2 2019 Annex. I
8 FTIR Analysis - Max Identcal to Yes ISO 22241-2 2019 Annex. J
reference
9 Trace Elements ppm - - ISO 22241-2 2006 Annex I
Calcium Content ppm 0.1

Iron Content ppm < 0.1

Copper Content ppm < 0.1

Zinc Content ppm < 0.1

Chromium Content ppm 0.1

Nickel Content ppm < 0.1

Aluminium Content ppm < 0.1

Magnesium Content ppm < 0.1

Sodium Content ppm 0.1

Potassium Content ppm < 0.1

Comment Sample meets the requirement as per standard ISO 22241.

Note : 1. Sampling is done by the party. The Test Result pertain to the sample(s) received for testng ithout preeudice of its lot, batches, source or process.
2. Comments given in the report are advisory only & shall not be used in case of legal maters. Test Reports shall not be reproduced ithout riten consent of Chem-Tech.
3. Sample ill be retained for one month from the date of testng unless other ise specifed by the customer.
4. The Laboratory is accredited under ISO/IEC 17025.#Indicates that the analyte is not mentoned in the published method scope. § Indicates that the method is not in Scope of
Accreditaton of the laboratory.

S – 22, Parvat Industrial Estate, Pune – Satara Road, Pune - 411009, Maharashtra.
Tel No.: +91 20 24228820, +91 20 24229020, Telefax: +91 20 24228020 Email: info@chemtechlabs.co.in, .chemtechlabs.com
PAGE 1 OF 2
TEST REPORT
CT F : 27
CUSTOMER INFORMATION REPORT AND SAMPLE INFORMATION
Palsani Green Power LLP ULR No : TC76952000000001F
87/110 Dr. Radha Krishnan Road Mylapore Test Report No : R191200414.001 Test Report Date : 02-1-2020
Date Sampled : 26-12-2019 Received Date : 30-12-2019
Chennai-600004, Date Analysed : 31-12-2019
TAMIL NADU, India Sample Type : Ad Blue
Kind Atn :Dhairya Palsani Conditon : Sample received in plastc container
Reference No.: Sample Desc : Batch No-1912201227
Reference Date: 31-12-2019

Authorized By

Saneay Da are
Senior Laboratory Manager

Note : 1. Sampling is done by the party. The Test Result pertain to the sample(s) received for testng ithout preeudice of its lot, batches, source or process.
2. Comments given in the report are advisory only & shall not be used in case of legal maters. Test Reports shall not be reproduced ithout riten consent of Chem-Tech.
3. Sample ill be retained for one month from the date of testng unless other ise specifed by the customer.
4. The Laboratory is accredited under ISO/IEC 17025.#Indicates that the analyte is not mentoned in the published method scope. § Indicates that the method is not in Scope of
Accreditaton of the laboratory.

S – 22, Parvat Industrial Estate, Pune – Satara Road, Pune - 411009, Maharashtra.
Tel No.: +91 20 24228820, +91 20 24229020, Telefax: +91 20 24228020 Email: info@chemtechlabs.co.in, .chemtechlabs.com
PAGE 2 OF 2