Sei sulla pagina 1di 1

Roof Nozzle Reinforcement API 620 section 5.

16 - cold

Roof Nozzle cold

INPUT DATA

Nozzle mark IN-2/ IN-3 IN-4 IN-5 / ON-2 A/B IN-6 A-D
Nominal diameter DN in 16 14 8 20

Thermal Distance piece wall sd mm 9,53 9,53 8,18 9,52


Outside dia distance piece D mm 406,4 355,6 219,1 508

Drawing no xxx xxx xxx xxx

Roof plate thickness selected tr mm 7 7 7 7


Required roof plate thickness (new) t reqrd mm 6,79 6,79 6,79 6,79
Corrosion allowance roof c mm 1,5 1,5 1,5 1,5
Repad thickness tp mm 10 12 12 12
Repad Diameter Dp1 mm 750 700 450 950
Limit of reinforcement (API 620) D lim mm 907 790 480 1142
Max ( (2*(De-2*(tn-c))) ; (2*(De/2+tr-c)) )

Outside roof radius R 36800 36800 36800 36800

OUTPUT DATA
Rh mm 18450 18450 18450 18450
arcsin (Rh / R) b degree 30,1 30,1 30,1 30,1

D/cos b De mm 470 411 253 587

Reinforcements API 620 5.16.5


Required: (De-2*sd +2*c) * (t reqd-c) Ar mm2 2400 2089 1269 3021

Provided:
Roof: (Dlim - De) * (tr - treq) A1 mm2 92 80 48 117
Pad: (Dp1 -De) * tp A4 mm2 2803 3468 2361 4355
Provided: A1 + A4 Ap mm2 2895 3548 2409 4471

Is provided area greater than


required area? Ap >= Ar ? Yes,Ok Yes,Ok Yes,Ok Yes,Ok

note: excess neck area A2 neglected